Supplementary Components Network transitions

Similar documents
IE/PB LINK PN IO. PROFINET applications

SIMATIC S Central processing units

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

CP ADVANCED. Function

CP BACNET Function

Supplementary Components WirelessHART products

SIMOTION P PC-based SIMOTION P350-3

Product type designation

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Application on Communication

SIMATIC ET 200SP Product information on documentation of the ET 200SP distributed I/O system Product Information

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

S7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK

PAS 300, PROFIBUS Slave Interface Module

TIM 3V- IE ADVANCED. Function

SIMATIC NET. SCALANCE Industrial Ethernet SCALANCE X- 100 and SCALANCE X-200 Product Line. Preface. Introduction. Network Topologies

Short Description. Version

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Operator Control and Monitoring Devices

Unmanaged Industrial Ethernet Switches

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

SIMATIC NET. Industrial Ethernet / PROFIBUS IE/PB LINK PN IO. Preface. Application and properties. LEDs, connectors, buttons 2

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Data sheet CPU 015PN (015-CEFPR01)

General information. Supply voltage. Input current

Service & Support. Replacing the Parent Hardware Module with the Successor Hardware Module (Migration) CP443-1 (Advanced) FAQ July 2012

SIPLUS S7-200TD 200. Overview

SIMATIC. ET 200SP BusAdapter. Preface 1. Guide. Product overview. BusAdapter BA 2xRJ45 4. BusAdapter BA 2xFC 5. BusAdapter BA 2xSCRJ 6.

CPU module for zone 2 Series 9442/35

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

WinAC RTX 2010 Getting Started. Getting-started. Edition ( )

Laboratory automation

ET 200S Motor Starters and Safety Motor Starters

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

The SIMATIC ET 200SP Open Controller: The compact PC-based controller from the S series siemens.com/open-controller

Data sheet VIPA CPU M13C (M13-CCF0000)

Parametrization, Configuration and Visualization with SIRIUS

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

Application for Process Automation

TIM DNP3 SIMATIC NET. Industrial Remote Communication - Telecontrol TIM DNP3. Preface. Uses and properties of the TIM

Industrial Communication. Short Catalog SIMATIC NET 10/2009 SIMATIC NET. Answers for industry.

Application for Process Automation

Notes on Installation and Use

PROFINET The leading communication system

Data sheet CPU 015PN (015-CEFPR00)

HARTING econ 3000 Introduction and features

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

General information. Supply voltage

Siemens AG Industrial Communication. SINEMA Server. Making your network transparent. Edition 09/2017. Brochure. siemens.

Data sheet CPU 013C (013-CCF0R00)

Product type designation. General information. Supply voltage

SCALANCE XB-000 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction. Network topologies. Description of the device 3.

Automation meets IT. SCALANCE X-500 central interface between Industrial Ethernet and IT networks SIMATIC NET. siemens.

Communication Bus System

SIMATIC. Bus links PN/PN coupler. Preface. Documentation guide. Product overview. Assembling 3. Connecting 4. Configuring, parameter assignment and

Multi Panel options. SIMATIC WinAC MP 2/169

Data sheet VIPA CPU 214PG (214-2BE03)

CPU 412H. Function. Parameterizable properties

Data sheet VIPA CPU 214NET PG (214-2BT13)


The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

PROFIBUS and Integrated Safety architectures in Ex areas

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Preface. Documentation guide. Product overview.

PROFIBUS. Connectors Repeaters FO Wireless system Communication

SIMATIC ET 200SP and ET 200MP

Cover. IP Address Assignment Using Primary Setup Tool (PST) Electrical Lean Switch. FAQ June Service & Support. Answers for industry.

Ha-VIS mcon 3000 Next Generation Introduction and features

Control Circuit Components

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

CAN 300 PRO, Communication Module

SIMATIC PCS 7 Standard Architectures

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

SIMATIC S plus TIA Portal

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved.

Product information on the documentation of the. ET 200SP distributed I/O system SIMATIC ET 200SP. ET 200SP distributed I/O system.

Siemens AG Industrial Communication. SINEMA Server. Making your network transparent. Edition 06/2018. Brochure. siemens.

Data sheet CPU 315SN/PN ECO (315-4PN33)

Product type designation. General information. Supply voltage. Input current

Notes on Installation and Use

EasyConnect PROFIBUS-Connector, 90

Panels 270 series SIMATIC TP 277 6" 2/131. Overview

IM PN HF interface module (6ES7155-6AU00-0CN0) SIMATIC. ET 200SP IM PN HF interface module (6ES7155-6AU00-0CN0) Preface

SIMATIC PCS 7 27 th September 2018 Stefan Goldhammer. Unrestricted Siemens AG 2018 SIEMENS AG/ PD PA AE SUP SPS

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

Transcription:

Siemens AG 201 Overview Benefits PROFINET applications Protection of investment due to simple connection of PROFI- BUS DP slaves to PROFINET IO controller Also enables use in plants with PROFIsafe applications Independence from individual vendors through support of the PROFINET standard for distributed field devices Easy engineering and extensive diagnostics options due to optimum TIA integration Applications with vertical integration Worldwide access to data of the stations via Industrial Ethernet and Internet for vertical integration Access to process data from all enterprise levels Loading of STEP programs from a central location PN DP-M DP-S ASi-M Compact network transition between PROFINET and - Connection to via integrated 2-port realtime switch with 100 Mbps full duplex connection with autosensing for automatic switchover - In case of replacement part: Connection to PROFINET also with 10 Mbps half duplex - Connection to with 9.6 Kbps to 12 Mbps PROFINET IO proxy; connection of DP slaves to PROFINET IO controller in accordance with PROFINET standard: From the viewpoint of the IO controller, all DP slaves are handled like I/O devices with Ethernet interface, i.e. the IE/PB LINK PN IO is their proxy Cross-network PG/OP communication by means of S routing Cross-network access to data of S stations for visualization by means of S OPC server and S routing; via the IE/PB LINK PN IO, access can be made from the (e.g. for HMI applications with OPC client interface) to data of the S stations on the by means of the S OPC server. High plant availability thanks to support of the Media Redundancy Protocol (MRP) Module replacement without the need for a programming device, using the C-PLUG swap media for backing up the configuration data Use in networks that support an exchange of devices without PG on the basis of the Link Layer Discovery Protocol (LLDP) ET200 SP design: use of the BusAdapter (BA) of the SIMATIC ET 200SP system for freely selecting the connection technology and physical characteristics for the PROFINET side G_IK10_XX_10191 Application As an autonomous component, the provides a seamless transition between and PROFI- BUS. Using the as a proxy, you can continue to use existing nodes (even with PROFIsafe functionality V2.0 or higher) and integrate them into a PROFINET application. The also offers cross-network PG/OP communication by means of S routing. In addition, data record routing ( DP) is supported. This means it is possible, for example, to use SIMATIC PDM (on the PC) on to parameterize and diagnose a field device via the. Design The has all the advantages of the SIMATIC ET200 SP design: Compact design; the front of the rugged plastic casing features: - Two RJ45 ports for connecting to ; the connection is made via the IE FC RJ45 Plug 90 with 90 cable outlet or via a standard patch cable - A 9-pin sub-d socket for connection to - A 4-pin terminal strip for connecting the external redundant supply voltage of 24 V DC (two infeeds) - Diagnostics LEDs Optional connection possibility for via Bus- Adapter (BA) of the SIMATIC ET 200SP system at the front Simple installation; the is mounted on a DIN rail Can be operated without a fan Fast device replacement in the event of a fault by using the optional C-PLUG swap medium (not included in scope of supply) Siemens FI 01 201 /43

Siemens AG 201 Function PROFINET PROFINET IO proxy; connection of DP slaves to PROFINET IO controller with real-time property, according to PROFINET standard SIMATIC HMI SIMATIC S-400 with CP 443-1 Advanced PROFINET IE/PB LINK PN IO ET 200SP ET 200SP ET 200SP ET 200S SINAMICS Migration for devices MICRO- MASTER ET 200M G_IK10_XX_30036 Example configuration: Seamless integration of nodes into PROFINET via the as proxy /44 Siemens FI 01 201

Siemens AG 201 Additional functionality for vertical integration S routing - Permits cross-network PG communication, i.e. all S stations on or can be programmed remotely using the programming device. - Access can be made to visualization data of S stations on the from HMI stations on the. Data record routing ( DP) - Using this option, the can be used as a router for data records that are forwarded to field devices (DP slaves). SIMATIC PDM (Process Device Manager) is a tool that creates data sets of this type for parameterizing and diagnosing field devices. The configuration of the IE/PB LINK PN IO is possible not only via the STEP / TIA Portal but also via the PST (Primary Setup Tool). The additional functions for vertical integration can also be used in an existing application without PROFINET for connection to a higher-level. In this case, the is used as an additional DP- Master Class 2 on a segment for linking to Industrial Ethernet and offers the above functions. Maintenance Station Engineering Station Operator Station PROFINET SIMATIC S-400 IE/PB LINK PN IO Sensors HART SINAMICS MICRO- MASTER ET 200M SITRANS P DP/PA Coupler PA G_IK10_XX_4000 Example configuration: Use of the as a default gateway without TIA Portal / STEP Media redundancy (MRP) Configuration Within a PROFINET network with a ring topology, the IE/PB LINK PN IO supports the media redundancy protocol MRP as an MRP client Diagnostics Extensive diagnostic options are available via STEP or SNMP, including: Diagnosis of the assigned field devices; using the as a proxy, the connected DP slaves can be diagnosed in the same manner as PROFINET IO devices (even in the user program of the PROFINET IO controller) General diagnostics and statistics functions Connection diagnostics Diagnostic buffer Integration into network management systems through the support of SNMP V1 MIB-II STEP V5.5 SP4 or higher or STEP Professional (TIA Portal) V14 Update 1 with an HSP is required for configuring the full functional scope of the. For the, STEP automatically generates the necessary parameters, e.g. the addresses and all necessary routing information. The configuration data for PROFINET IO created with STEP is saved on the IO controller. Attention must however be paid to the memory capacity. The initialization data for the interface is backed up on the C-PLUG (Configuration Plug) swap media. The can be swapped in the event of failure without a programming device because the relevant configuration data is saved on the IO controller or on the C- PLUG. SINEMA E (-free TIA Portal for network components) The IP and parameters, as well as the network settings, can also be assigned with SINEMA E (V14 or higher), if the is only to be used as a network transition and not as a PROFINET IO device. Primary Setup Tool (PST) The IP and parameters, as well as the network settings, can also be assigned without STEP / TIA Portal, but with the aid of PST (Version 4.3 or higher). Siemens FI 01 201 /45

Siemens AG 201 Technical specifications Order number 6GK1411-5AB10 Product type designation Transmission rate Transfer rate for 10... 100 Mbit/s 9.6 kbit/s... 12 Mbit/s Interfaces Number of interfaces acc. to Industrial 1 Ethernet Number of electrical connections 2 1 for power supply 2 Type of electrical connection 9-pin Sub-D socket (RS485) RJ45 port for power supply 4-pole terminal block Design of the removable storage C-PLUG Supply voltage, current consumption, power loss Type of voltage of the supply voltage DC Supply voltage external 24 V Supply voltage external at DC Rated 24 V value Relative positive tolerance at DC at 20 % 24 V Relative negative tolerance at DC at 15 % 24 V Consumed current from external supply voltage at DC at 0.2 A 24 V typical from external supply voltage at DC at 0.3 A 24 V maximum Power loss [W] 4.8 W Permitted ambient conditions Ambient temperature for vertical installation 0... 40 C during operation for horizontally arranged busbars 0... 60 C during operation during storage -40...+0 C during transport -40...+0 C Relative humidity at 25 C without 95 % condensation during operation maximum Protection class IP IP20 Design, dimensions and weight Width 100 mm Height 11 mm Depth 4 mm Net weight 0.6 kg Mounting type 35 mm DIN rail mounting Performance data DP Service as DP master DPV1 Number of DP slaves on DP master 65 usable Amount of data of the address area of the inputs as 2048byte DP master total of the address area of the outputs as 2048byte DP master total of the address area of the inputs per 244 byte DP slave of the address area of the outputs 244 byte per DP slave Performance data S communication Number of possible connections for S communication maximum 32 Performance data multi-protocol mode Number of active connections with 48 multi-protocol mode Performance data PROFINET communication as PN IO-Device Product function PROFINET IO device Performance data telecontrol Protocol is supported TCP/IP Product function MIB support Protocol is supported SNMP v1 DCP LLDP Identification & maintenance function I&M0 - device-specific information I&M1 higher-level designation/location designation I&M3 - comment Product functions switch Product feature Switch Product function Configuration with STEP Product functions Routing Service as dataset routing Number of possible connections at 32 data record routing maximum Product functions Redundancy Product function Ring redundancy Protocol is supported Media Redundancy Protocol (MRP) Product functions Time Product function SICLOCK support Product function pass on time synchronization Protocol is supported NTP /46 Siemens FI 01 201

Siemens AG 201 Selection and ordering data Article No. Article No. 6GK1411-5AB10 S-300 mounting rail 6ES390-1AB60-0AA0 Network transition between Industrial Ethernet and with PROFINET IO functionality, TCP/IP, S routing and data record routing, 10/100 Mbps Fast Ethernet, 9.6 to 12 Mbps ; including electronic manual on CD- ROM German, English, French, Spanish, Italian IE FC TP Standard Cable GP 2 x 2 (Type A) 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/IE FC RJ45 Plug; PROFINET-compliant; with UL approval; sold by the meter; max. length 1 000 m, minimum order 20 m IE FC RJ45 Plug 180 RJ45 plug connector for Industrial Ethernet with a rugged metal enclosure and integrated insulation displacement contacts for connecting FC installation cables; with 180 cable outlet; for network components and CPs/CPUs with interface 1 pack = 1 unit 1 pack = 10 units 1 pack = 50 units IE FC Stripping Tool Preadjusted stripping tool for fast stripping of the FC cables CSM 3 Compact Switch Module Unmanaged switch for connection of a SIMATIC S-300-CPU, ET 200M and up to three further nodes to operating at 10/100 Mbps; 4 x RJ45 ports; external 24 V DC power supply, LED diagnostics, S-300 module including electronic manual on CD-ROM C-PLUG Swap medium for simple replacement of devices in the event of a fault; for storing configuration or engineering and application data; can be used for SIMATIC NET products with C-PLUG slot FC Standard Cable GP Standard type with special design for fast mounting, 2-core, shielded, FastConnect bus connector RS 485 Plug 180 With insulation displacement terminals, with 180 cable outlet, for industrial PC, SIMATIC HMI OP, OLM; max. transmission rate 12 Mbps FastConnect Stripping Tool 6XV1840-2AH10 6GK1901-1BB10-2AA0 6GK1901-1BB10-2AB0 6GK1901-1BB10-2AE0 6GK1901-1GA00 6GK3-1AA00-0AA0 6GK1900-0AB00 6XV1830-0EH10 6GK1500-0FC10 6GK1905-6AA00 S-300 PS 30 load power supply 6ES30-1BA01-0AA0 24 V DC STEP Version 5.5 Target system: SIMATIC S-300/-400, SIMATIC C, SIMATIC WinAC Requirements: Windows XP Prof., Windows Professional/Ultimate Type of delivery: German, English, French, Spanish, Italian; including key on USB stick, with electronic documentation For CP 343-1 Lean, CP 343-1, CP 343-1 Advanced, CP 343-1 ERPC, CP 443-1, CP 443-1 Advanced, CP 443-1 RNA Floating on DVD 6ES810-4CC10-0YA5 Rental for 50 hours 6ES810-4CC10-0YA6 Software Update Service on DVD 6ES810-4BC01-0YX2 (requires current software version) Upgrade floating 6ES810-4CC10-0YE5 3.x/4.x/5.x to V5.5; on DVD Trial STEP V5.5; on DVD, 6ES810-4CC10-0YA 14 day trial STEP Professional V12 Engineering Software Target system: SIMATIC S-1200, S-1500, S- 300, S-400, WinAC Requirement: Windows XP Home SP3 (STEP Basic only), Windows XP Professional SP3 (32 bit), Windows Home Premium SP1 (STEP Basic only), Windows Professional SP1 (32/64 bit), Windows Enterprise SP1 (32/64 bit), Windows Ultimate SP1 (32/64 bit), Microsoft Server 2003 R2 Std. SP2 (32 bit), Microsoft Server 2008 Std. SP2 (32/64 bit) Form of delivery: German, English, Chinese, Italian, French, Spanish For CP 1543-1, CP 343-1 Lean, CP 343-1, CP 343-1 Advanced, CP 343-1 ERPC, CP 443-1, CP 443-1 Advanced STEP Professional V12, floating 6ES822-1AA02-0YA5 STEP Professional V12, trial 6ES822-1AA02-0YA Upgrade STEP Professional V11 6ES822-1AA02-0YE5 to STEP Professional V12, floating Upgrade STEP 6ES822-1AA02-0XE5 Professional 2006/2010 to STEP Professional V12, floating PowerPack & upgrade 6ES822-1AA02-0XC5 from STEP V5.4/V5.5 to STEP Professional V12, floating PowerPack STEP Basic V12 to 6ES822-1AA02-0YC5 STEP Professional V12, floating Preadjusted stripping tool for fast stripping of FastConnect bus cables Siemens FI 01 201 /4

Siemens AG 201 STEP Professional Engineering Software V12; software download incl. key 2 E-mail address required for the delivery STEP Professional V12, floating STEP Professional V12, trial ; Upgrade STEP Professional V11 to STEP Professional V12, floating Upgrade STEP Professional 2006/2010 to STEP Professional V12, floating PowerPack & upgrade from STEP V5.4/V5.5 to STEP Professional V12, floating PowerPack STEP Basic V12 to STEP Professional V12, floating STEP Professional V13 engineering software Target system: SIMATIC S-300/-400, SIMATIC S- 1200/1500, SIMATIC C, SIMATIC WinAC Requirement: Windows Professional (32 bit), Windows Enterprise (32 bit), Windows Ultimate (32 bit), Microsoft Server 2003 R2 Std. SP2 (32 bit), Microsoft Server 2008 Std. SP2 (32 bit) Form of delivery: German, English, Chinese, Italian, French, Spanish For CP 1243-1, CP 1543-1, CM 1542-1, CP 343-1 Lean, CP 343-1, CP 343-1 Advanced, CP 343-1 ERPC, CP 443-1, CP 443-1 Advanced STEP Professional V13, floating STEP Professional V13, trial Upgrade STEP Professional 2006/2010 to STEP Professional V13, floating PowerPack & upgrade STEP V5.4/V5.5 to STEP Professional V13, floating PowerPack STEP Basic V13 to STEP Professional V13, floating STEP Professional V13, Software Update Service, 1 year; current software version required STEP Professional V13, Software Update Service Compact, 1 year; current software version required STEP Professional Software Update Service; 1 year; for STEP Professional and STEP Professional in the TIA Portal, requires current software version STEP Professional Software Update Service Compact; 1 year; for STEP Professional and STEP Professional in the TIA Portal, requires current software version Article No. 6ES822-1AE02-0YA5 6ES822-1AE02-0YA 6ES822-1AE02-0YE5 6ES822-1AE02-0XE5 6ES822-1AE02-0XC5 6ES822-1AE02-0YC5 6ES810-6ES810- Accessories C-PLUG BusAdapter The BusAdapters offer a free selection of connection technology and physical characteristics for the PROFINET interface. Alternatively, they can be used for the interface on the device. The following bus adapter versions are supported by the IE/PB LINK PN IO: Versions with two PN copper interfaces (RJ45 or FastConnect (FC)) BA 2xRJ45 with 2 RJ45 connections BA 2xFC with 2 FastConnect connections: enables maximum system availability, even when subjected to shocks and high electromagnetic loads. This is because the FastConnect cables are fully shielded and laid directly in the BusAdapter. Versions with one or two PN fiber-optic cable (FOC) connections BA 2xSCRJ with 2 SCRJ FO connections with increased potential difference BA SCRJ / RJ45, each with one SCRJ FO and RJ45 connection (media converter) BA SCRJ / FC, each with one SCRJ FO and FastConnect connection (media converter) BA 2xLC with two glass fiber-optic connections (Lucent Connector) with increased potential difference BA SCRJ / RJ45, each with one glass fiber-optic and RJ45 connection (media converter) BA LC / FC with one glass fiber-optic and one FastConnect connection (media converter) The version for connecting IP6 modules of the SIMATIC ET 200AL (BA-SEND, BA 1xFC) is not supported. More information http://www.siemens.com/profinet /48 Siemens FI 01 201