Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Similar documents
Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Messaging module CP-C MM

Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-AHD.22

Electronic timer CT-ERS.21

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Three-phase monitoring relay

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Thermistor motor protection relay CM-MSS.41

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Thermistor motor protection relay CM-MSS.21

Redundancy unit CP-A RU

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Thermistor motor protection relay CM-MSS.11

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.31

Power supply CP-E 48/1.25 Primary switch mode power supply

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Contact protection relay

Power supply CP-E 24/10.0 Primary switch mode power supply

Pluggable interface relays CR-P Pcb relays

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Accessories for pluggable interface relays CR-P Sockets

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Pluggable interface relays CR-M Miniature relays

Power supply CP-C 24/5.0

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

Power supply CP-C 24/5.0

Accessories for pluggable interface relays CR-U Pluggable function modules

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Electronic timers CT range

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ABB i-bus KNX HCC/S Heating/cooling circuit controller

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

TU531, TU532 Terminal Unit

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ABB i-bus KNX BCI/S Boiler/Chiller Interface

AO523 Analog Input Module

Binary output and supervision 520CSD01 Data sheet

TF501, TF521 Terminal Bases

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DI572 Digital Input Module

AI561 Analog Input Module

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

DC561, digital input/output module,

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

DI561 Digital Input Module

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

DC562, digital input/output module,

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

DX561 Digital Input/Output Module

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Transcription:

Data sheet Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact The CT-ARE is an electronic time relay with OFF-delay. It is from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance ratio for OEM users. This is achieved by simplified functionality and results in the simplest of setup procedures. The CT-E range is ideally suited for repeat applications. 1SVR 550 127 F4100 Characteristics 4 versions: 2 different single time ranges (0.1-10 and 0.3-30 s) and 2 different rated control supply voltage ranges (24 V AC/DC / 220-240 V AC and 110-130 V AC) Single-function OFF-delay timer 1 c/o (SPDT) contact 22.5 mm (0.89 in) width 1 LED for the indication of operational states Approvals A UL 508, CAN/CSA C22.2 No.14 C GL D GOST K CB scheme E CCC RMRS L Marks a CE b C-Tick Order data Type Rated control supply voltage Time range Order code CT-ARE 24 V AC/DC, 220-240 V AC 0.1-10 s 1SVR 550 127 R1100 0.3-30 s 1SVR 550 127 R4100 110-130 V AC 0.1-10 s 1SVR 550 120 R1100 0.3-30 s 1SVR 550 120 R4100

Functions Operating controls 1 Indication of operational states U: green LED Control supply voltage applied 2 Thumbwheel for the fine adjustment of the time delay 1 1SVR 550 127 F4100 2 Application Their conception makes the CT-E range timers ideal for repeat applications. Operating mode The fine adjustment of the time delay is made via the front-face thumbwheel. 2 - Electronic timer CT-ARE Data sheet

Function diagram B OFF-delay without auxiliary voltage (True delay on break) The OFF-delay function without auxiliary voltage does not require continuous control supply voltage for timing. Applying control supply voltage, energizes the output relay. If control supply voltage is interrupted, the OFF-delay starts. When timing is complete, the output relay de-energizes. If control supply voltage is re-applied before the time delay is complete, the time delay is reset and the output relay remains energized. Control supply voltage must be applied for the minimum energizing time (200 ms), for proper operation. A1-A2/B1 15-18 15-16 green LED t 2CDC 252 133 F0205 t = adjusted delay time Electrical connection A1 15 B1 A1 B1 15 A1-A2 Rated control supply voltage U s : 220-240 V AC A1-B1 Rated control supply voltage U s : 24 V AC/DC 15-16/18 1 c/o (SPDT) contact A2 16 18 16 18 A2 2CDC 252 155 F0005 Connection diagram 1SVR 550 127 R1100, 1SVR 550 127 R4100 A1 15 A1-A2 15-16/18 1 c/o (SPDT) contact Rated control supply voltage U s : 110-130 V AC A1 15 A2 16 18 16 18 A2 2CDC 252 291 F0005 Anschlussdiagramm 1SVR 550 120 R1100, 1SVR 550 120 R4100 Data sheet Electronic timer CT-ARE - 3

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Supply circuit Rated control supply voltage U s A1-A2 220-240 V AC A1-A2 110-130 V AC A1-B1 24 V AC/DC Rated control supply voltage U s tolerance -15...+10 % Typical current / power consumption 24 V AC/DC approx. 1.0 VA/W 110-130 V AC approx. 2.0 VA 220-240 V AC approx. 2.0 VA Rated frequency AC/DC version DC or 50/60 Hz AC version 50/60 Hz Minimum energizing time 200 ms Timing circuit Time range Recovery time depending on device: 0.1-10 s or 0.3-30 s < 200 ms Repeat accuracy (constant parameters) Dt < 1 % Accuracy within the rated control supply voltage tolerance Dt < 0.5 % / V Accuracy within the temperature range Dt < 0.1 % / C User interface Indication of operational states Control supply voltage U: green LED V: control supply voltage applied Output circuit Kind of output 15-16/18 relay, 1 c/o (SPDT) contact Contact material AgCdO Rated operational voltage U e (IEC/EN 60947-1) 250 V Maximum switching voltage 250 V AC, 250 V DC Rated operational current I e AC12 (resistive) at 230 V 4 A (IEC/EN 60947-5-1) AC15 (inductive) at 230 V 3 A DC12 (resistive) at 24 V 4 A DC13 (inductive) at 24 V 2 A AC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC Maximum continuous thermal current at B300 5 A max. making/breaking apparent power at B300 3600 VA / 360 VA Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime AC12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve n/c contact 5 A short-circuit protection n/o contact 5 A 4 - Electronic timer CT-ARE Data sheet

General data MTBF on request Duty time 100 % Dimensions (W x H x D) product dimensions 22.5 x 78.0 x 78.5 mm (0.89 x 3.07 x 3.09 in) packaging dimensions 84.2 x 83.1 x 24.6 mm (3.31 x 3.27 x 0.97 in) Weight net weight 0.070 kg (0.154 lb) gross weight 0.081 kg (0.179 lb) Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Degree of protection housing IP50 terminals IP20 Electrical connection Wire size fine-strand with wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) fine-strand without wire end ferrule 2 x 1-1.5 mm 2 (2 x 18-16 AWG) rigid 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) Stripping length 10 mm (0.39 in) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) Environmental data Ambient temperature ranges operation -20...+60 C storage -40...+85 C Operational reliability IEC/EN 60068-2-6 6 g Mechanical resistance IEC/EN 60068-2-6 10 g Damp heat, cyclic IEC/EN 60068-2-30 24 h cycle, 55 C, 93 % rel., 96 h Isolation data Rated insulation voltage between supply, control and output circuit (IEC/EN 60947-1) Rated impulse withstand voltage U imp between all isolated circuits (IEC/EN 60664) Test voltage between all isolated circuits (routine test) Pollution degree (IEC/EN 60664, IEC/EN 60255-5) Overvoltage category (IEC/EN 60664, IEC/EN 60255-5) Control supply voltage up to 240 V: 300 V Control supply voltage up to 440 V: 500 V 4 kv / 1.2-50 μs 2.5 kv, 50 Hz, 1 min. III/C III/C Standards Product standard IEC 61812-1, EN 61812-1 +A11 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kv / 5 khz) surge IEC/EN 61000-4-5 Level 4 (2 kv L-L) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) radio-frequency fields Interference emission IEC/EN 61000-6-4 Data sheet Electronic timer CT-ARE - 5

Technical diagrams Load limit curves V V 300 200 V V 300 200 100 80 60 50 40 30 100 80 60 50 40 30 20 20 10 0.1 0.2 0.5 1 2 4 6 10 I A 2CDC 252 194 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A 2CDC 252 193 F0205 AC load (resistive) DC load (resistive) F 1.0 0.9 0.8 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ 2CDC 252 192 F0205 10 6 9 8 N 5 4 3 2 10 5 1 Contact lifetime /switching cycles N 220 V 50 Hz AC1, 360 cycles/h 2 3 4 5 6 7 8 I A 2CDC 252 034 F0208 2CDC 252 034 F0208 Derating factor F for inductive AC load 6 - Electronic timer CT-ARE Data sheet

Dimensions in mm and inches 88,5 3.48 81 3.19 22,5.886 78 3.07 78,5 3.09 2CDC 252 189 F0005 Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC 110 004 C02xx You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products -> Electronic Relays and Controls -> Time Relays. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/partcommunity/ Portal/abb-control-products -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls -> Time Relays -> CT-E - Time Relays. Data sheet Electronic timer CT-ARE - 7

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 111 138 D0201 (03.2013) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2013 ABB All rights reserved