FLAP indicator. Installation manual Version 1.10

Similar documents
PDA-CAN Bridge. Version 1.0. LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel fax

LXNAV RS485 to RS232 Bridge

V8/V80. Installation manual. Version 5.0

Flarm LED indicator. Version 1.1

FES BMS CONTROL MANUAL

PowerMouse Version 1.00 November PowerMouse. The FlarmMouse successor. Version 1.00

PowerMouse Version 1.05 March PowerMouse. The FlarmMouse successor. Version 1.05

FES LCD Display Version 1.1

FES BMS CONTROL MANUAL

The Smallest flarm with integrated GPS antenna. Version 1.01

FES SYSTEM MANUAL. Version 1.22

FlarmView and FlarmView57

NANO. Flight recorder (including NanoConfig configuration program) Version 1.0

Craggy Aero Ultimate Le 5.7

FlarmView and FlarmView57

Trimble S6 and SPS700 Total Station Firmware

Woolich Racing. USB ECU Interface User Guide

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

TB-24P/24R/16P8R. Relay Outputs or Isolated Inputs Terminal Board Series

Instruction Manual. CT-4 High-Current Transformer

Piccola Smart Box Member of Modul MAS family

USB Server User Manual

FlarmView 2. Version LXNAV d.o.o. Kidričeva 24a, 3000 Celje, Slovenia tel fax

ACLD Channel Opto-isolated Digital Input Board

PCMCIA Flash Card User Guide

Chore-Tronics Mobile Server

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

HDF-2 High Depth-of-Field Macroscope

Instruction Sheet. PCS Series. Fiber\Cable Management Spool

Compact USB Digital Speakers. Quick Start User Guide

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

CIKA DEVKIT35P Quick Start Guide

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

Instructions. RM3000 Rackmount Kit for TDS3000 Series Oscilloscopes

Sensoray Model 627 CompactPCI to PCI Adapter

Wall. No opening (Example: LA-030-W)

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

TB-100 ControLynx Terminal Block

Shanghai Naxing Electronics Co., Ltd. NBD02 BeagleBone Companion Board. Data Sheet Rev. 0.1

FNet Repeater Installation & Operator s Instruction Manual

User Manual TLS HDMI Switch Splitter 3/2

F2MC MB90385 series Evaluation Board Documentation. Revision Date Comment V New document

10 Digital Photo Frame Instructional Manual

TDM-170 TIMER DISPLAY

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

Trimble R/5000 Series GPS Receivers Release Notes

14 Digital Photo Frame Instructional Manual

SKM 04. User Manual. 4-Port Keyboard, Mouse and Audio Switch with USB 2.0 Sharing

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

TDM-150 TIMER DISPLAY

Instruction Guide. 2 Firewire 4 USB 3.5 Bay Front Panel Hub 35BAYFWUSB. The Professionals Source For Hard-to-Find Computer Parts

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Instruction Sheet ICLS-COOL TM. Quiet-Cool Series Closet Cooler ICLS-COOL1 ICLS-COOL2

Networking. with Druid Energizers and Smartcards

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

Data Reporter. Installation-Operation E rev.f

ASCL1 / ASCL2 CarLink Guide for Android Users

LX Sim. Version 1.2. LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel fax

Pit Transition with 24" Fan Installation and Operators Instruction Manual

F²MC-8L FAMILY MB89201 SERIES FLASH PROGRAMMING 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

12 Digital Photo Frame Instructional Manual

CM Mpixel CMOS Imaging Camera

OCEANIC SYSTEMS MULTIPLE ENGINE DISPLAY Part Numbers: 4161 USER MANUAL

INTMOD485-LH Protocol Converter

Grundfos MAGNA, GENI Module

MPE5 Scouting Camera Instruction Manual.

10 Slim Digital Photo Frame Instructional Manual

Wasp Embedded Controller

User Guide. Control Box. RoscoLED TM.

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

raspais A21100 receiver - multimedia Manual english Vers.: 1.2 Page 1

Proliphix EPA-60 Installation Guide

TD 600 Thermo-Fastprinter

High Speed Shutter. Owner s Manual. Revision 1.0. Copyright 2012 Cognisys, Inc.

Illuminate 25 Light Starter Kit What s included Light String Control Box Spare Fuses Safety Instructions Quick Start Guide

User Manual. Spectrum Pro

IRRIGANDER 4 SPLITTER SWITCH

WARRANTY & LIMITATION OF LIABILITY

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

1:4 DVI Splitter EXT-DVI-144N

Transport Pro FireWire and USB Portable Hard Drive

PingStation User and Installation Guide

WARRANTY & LIMITATION OF LIABILITY

OPERATIONS MANUAL PCM-DOC

FastForward TM User Guide

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Instruction Guide. External 3.5" IEEE-1394b FireWire 800 and USB 2.0 Combination IDE Hard Drive Enclosure IDECASEU2FB

Advanced 4/8 Port Secure KM Switch

FastForward User Guide

OPERATIONS MANUAL PCM-I/O48

62532 (EN649) Ethernet Adapter

General Notice Introduction Functional Description Product Troubleshooting Driver Setup...

HDTVMT User Manual

PMDX-170 Slotted Optical Sensor

Table Contents. Introduction Key Features...2. Getting Started Package Contents...3. Minimum System Requirements...3

Transcription:

FLAP indicator Installation manual Version 1.10 LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel +386 592 33 400 fax +386 599 33 522 info@lxnav.com www.lxnav.com

1 Important Notices... 3 1.1 Limited Warranty... 4 2 Installations... 5 2.1 Packing Lists... 5 2.2 Basics... 5 2.3 Electrical specifications... 5 2.3.1 Absolute maximum ratings with respect to GND... 5 2.3.2 Recommended electrical and mechanical characteristics... 5 2.4 Installation... 6 2.5 Wirings... 6 2.5.1 Slave mode wiring... 6 2.5.2 Standalone mode wiring... 7 2.6 Setting flap positions... 7 2.6.1 LX80xx, LX90xx... 7 2.6.2 PC via mini USB... 8 2.7 Updating firmware of Flap Indicator... 9 2.7.1 LX80xx, LX90xx... 9 2.7.2 PC via mini USB... 9 2.8 Dimmensions... 11 3 Revision History... 12 Page 2 of 12

1 Important Notices Information in this document is subject to change without notice. LXNAV reserves the right to change or improve their products and to make changes in the content of this material without obligation to notify any person or organisation of such changes or improvements. A Yellow triangle is shown for parts of the manual which should be read very carefully and are important for operating the system. Notes with a red triangle describe procedures which are critical and may result in loss of data or any other critical situation. A bulb icon is shown when a useful hint is provided to the reader. Page 3 of 12

1.1 Limited Warranty This LXNAV product is warranted to be free from defects in materials or workmanship for two years from the date of purchase. Within this period, LXNAV will, at its sole discretion, repair or replace any components that fail in normal use. Such repairs or replacement will be made at no charge to the customer for parts and labor, provided that the customer shall be responsible for any transportation cost. This warranty does not cover failures due to abuse, misuse, accident, or unauthorized alterations or repairs. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. IN NO EVENT SHALL LXNAV BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE, OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. Some states do not allow the exclusion of incidental or consequential damages, so the above limitations may not apply to you. LXNAV retains the exclusive right to repair or replace the unit or software, or to offer a full refund of the purchase price, at its sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. To obtain warranty service, contact your local LXNAV dealer or contact LXNAV directly. August 2018 2018 LXNAV. All rights reserved. Page 4 of 12

2 Installations 2.1 Packing Lists Flap Indicator unit 2.2 Basics The LXNAV FLAP indicator is a small display unit with a red 10x7 LED matrix display (sup for) indicating preconfigured flap positions. It can be used as a part of main instrument or as stand-alone unit connected only to a LXNAV FLAP sensor. The indicator has no buttons or any other user interactives. All settings and firmware upgrades on the device are made over the main instrument, or a PC via mini a USB cable. At startup indicator will roll its name over the display as FLIND, (sup when follows) followed by the app or rec and at the end, version of firmware for example v1.00. app (application) means that Flap indicator is in the operation mode, and waiting either for settings from the main unit, PC or data from the FLAP sensor to show its position. If the indicator is in the rec mode (recovery), then it will not show any data. The reason could be in errors while upgrading the firmware such as a cable disconnection, low voltage, etc. In case the FLAP indicator is going to be used in a standalone operation, it has to be purchased with: FLAP sensor RS485 splitter Power cable with termination 2.3 Electrical specifications 2.3.1 Absolute maximum ratings with respect to GND Parameter Symbol Rating Units Power Supply Vmax 40.0 V Power Consumption at 12V Imax 200 ma 2.3.2 Recommended electrical and mechanical characteristics Parameter Symbol Min Typ Max Units Power Supply Vin 8.0 12.0 28.0 V Operation temperature range T wr -20 - +60 C Storage temperature T st -40 - +80 C Page 5 of 12

2.4 Installation The flap indicator has a specific, non-standard enclosure that fixes to airplane panel with two M4 screws on 41 mm distance between them. Mount it horizontally with a mini USB connector on top. 2.5 Wirings Figure 1: Recommended panel cutout (hatched area) The LXNAV Flap indicator is connected to the RS485 bus through an RS485 splitter and a SUB D9 connector. The splitter is not part of the package. If you don`t have a spare port on it, you must order another 485 splitter. Along the flap indicator (supp should be mounted also) one should also mount a FLAP sensor from which the indicator receives data. 2.5.1 Slave mode wiring In the slave mode, connecting the FLAP indicator to an RS485 bus is the same as for any other LXNAV instrument. Connect it to any free port on the RS485 splitter. Figure 2: Example of slave wiring Page 6 of 12

2.5.2 Standalone mode wiring When the FLAP indicator is used in the standalone mode, connect it to an RS485 splitter along FLAP sensor. Two devices are powered from third connector on which is power cable and a built-in termination resistor. 2.6 Setting flap positions Figure 3: Wiring of FLAP indicator in standalone mode Putting the FLAP indicator in the working mode is selected automatically. When it receives a flap setting from the main unit, such as an LX9000, it goes into slave mode. This means, the indicator is just listening on the RS485 bus. The second option is, when there is no main unit. In that case, it goes in standalone mode and is constantly asking the FLAP sensor for the current position. The standalone mode is selected right after the user sends settings to the FLAP indicator over the USB. Setting the flap positions is described in following chapters. 2.6.1 LX80xx, LX90xx On the main unit, under the Setup menu, go to Hardware and Flaps. Put the flaps (sup to) in the upper position, move the cursor on the instrument to the first box, and click the SET button. This will save current angle set from the FLAPS sensor to the first box. Write the name for this state, and repeat the same action for the remaining positions. When this is finished, click the CLOSE button, and all data will be sent to the FLAP indicator. Figure 4: Example of saved flap positions on LX9000 main unit Page 7 of 12

If the positions are already saved, after a first startup with the FLAP indicator, wait for a minute, and the instrument is going to update the indicator automatically. When it receives data, it will save them to its internal memory, and show them next time right after the system startup. 2.6.2 PC via mini USB This option is available only for the standalone mode of the FLAP indicator. Settings made over the Flap configurator tool will not be sent to the main unit, instead they will be rewritten by LX80/90xx. Connect the mini USB connector to the FLAP indicator after powering up. On your computer you should see a new serial communication port. Under Settings, in Flap configurator, select it, and then press the Connect button just next to Settings. Now you are able to see the current flap angle. Put the flaps in the upper position, write its name in the Pos1 name text box, and press the Set button to determine the angle. Repeat the same process for the remaining flap positions. When it is done, click the Save (sup button) and Disconnect buttons. Now you are ready to use the FLAP indicator with the FLAP sensor. Figure 5: Flap configurator with FLAP indicator settings Page 8 of 12

2.7 Updating firmware of Flap Indicator Latest firmware for LXNAV instruments can be found on: http://www.lxnav.com/download/firmware Update is possible with one of the following two examples: 2.7.1 LX80xx, LX90xx Firmware updates can be done via a main unit such as the LX 80/90xx. 1.) Start the main unit with the connected FLAP indicator. 2.) Go to: Setup->Password and type in 89891 3.) If there is only one update file, it will automatically update the indicator. Otherwise it should be selected manually. The update filename name is App_FIND_x.yy.lxfw, where x.yy is the firmware version. 4.) When the update is done, the FLAP indicator will restart with the new firmware and the previously saved settings. 2.7.2 PC via mini USB Figure 6: Select update file for FLAP indicator The second option for firmware updating is via a PC, and is the only way when the FLAP indicator is used without the main unit. 1.) Download FlashLoader485App (PC update tool) from the LXNAV website under the section for S7 instruments: www.lxnav.com/download/firmware 2.) Connect the mini USB connector to the FLAP indicator, and on the other side, to your PC. 3.) Power up the indicator over the SUB D9 connector. In this case, when the USB is connected before powering up the instrument, it goes in recovery mode, which can be seen from the welcome text FLIND rec vx.yy on the screen. From this moment on, the firmware can be updated. Page 9 of 12

4.) Choose the correct serial port. Baudrate has no function leave it as it is. 5.) Chose the firmware file App_FIND_x.yy.lxfw, where x.yy is the version. 6.) Press the Flash button, and the update will start. After a successful update, the indicator will restart and go back in recovery mode; thus the USB has to be disconnected and the indicator repowered. If the update procedure is interrupted (supp of any case) for any cause, the FLAP indicator will cycle in recovery mode and it has to be updated again following the process described above. Figure 7: Flash Loader update tool after a successful firmware update Page 10 of 12

2.8 Dimmensions Figure 8: FLAP indicator outer dimmensions Drawing is not to scale Page 11 of 12

3 Revision History September 2017 August 2018 Initial release English correction by JR. Page 12 of 12