IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

Similar documents
IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

IPmux-1E TDM Pseudowire Access Gateway

IPmux-1E. TDMoIP Gateway FEATURES

IPmux-16 TDM Pseudowire Access Gateway

IPmux-14. TDM Pseudowire Access Gateway FEATURES

IPmux-24 TDM Pseudowire Access Gateway

IPmux-4LGE TDM Pseudowire Gateway

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

PSEUDOWIRE PERFORMANCE

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

FCD-E1E Managed E1 and Fractional E1 Access Device

Gmux Modular TDMoIP Gateway FEATURES

Optimux-34, Optimux-25

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Optimux-108, Optimux-106

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

IPmux-2L, IPmux-4L. IPmux-2L, IPmux-4L are a TDM pseudowire. also serves as an Ethernet-based access device.

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

Optimux-1032, Optimux-1025

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

ASMi-54 SHDSL.bis Modem

Optimux-34 Fiber Optic Multiplexer

Multiservice Network Termination Unit

Where to buy > Product page >

Optimux-4T1 Four-Channel T1 Multiplexer

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Vmux-210 Analog Voice Trunking Gateway

ASMi-54L SHDSL.bis Modem

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

ETX-102 Carrier Ethernet Demarcation Device

2/4-wire SHDSL Modem/Multiplexer

Vmux-110. Voice Trunking Gateway FEATURES

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Vmux-400 GSM A-bis/A-ter Optimization Gateway

Product page > Link-layer OAM according to IEEE 802.3ah is used for fault indication and loopback activation response.

ASMi-54L. Data Sheet. SHDSL.bis Modem

IPmux-216 TDM Pseudowire Access Gateway

FCD-155 STM-1/OC-3 Terminal Multiplexer

ASMi-54 SHDSL.bis Modem

Vmux-2120 Voice Trunking Gateway

MARKET SEGMENTS AND APPLICATION

Optimux-108, Optimux-106

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

LA-140. Advanced ATM IAD FEATURES

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

FOMi-40 Fiber Optic Modem with Remote Management

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

IPmux-24 TDM Pseudowire Access Gateway

Optimux-108, Optimux-106

Vmux-110 Voice Trunking Gateway for Remote Sites

RICi-16 Ethernet over Bonded PDH Network Termination Unit

IPmux-216 TDM Pseudowire Access Gateway

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

FCD-155 STM-1/OC-3 Terminal Multiplexer

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

RICi-16 Ethernet over Bonded PDH Network Termination Unit

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

ACE-3000 Family ACE-3100 Cell-Site Gateway

ACE-3000 Family ACE-3105 Cell-Site Gateway. 2G, 3G and HSDPA cellular traffic over packet-switched networks (PSNs) and ATM, using DSL uplinks

Note: IPmux-155L equipped with the AC or 48 power supply modules supports up to 16 MiRICi-E3T3 units.

SFP Transceivers Small Form-Factor Pluggable Transceivers

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

ETX-201A Carrier Ethernet Demarcation Device

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules

SFP Transceivers Small Form-Factor Pluggable Transceivers

ACE-3000 Family ACE-3200 Cell-Site Gateway

ATM OVER PACKET CAPABILITIES

BROAD RANGE OF INTERFACES

ACE-3000 Family ACE-3400 Aggregation Site Gateway

LA-110 Advanced Integrated Access Device

ACE-3000 Family ACE-3105 Mobile Backhauling Cell-Site Gateway

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

TDM over IP. International Department

ETX-203AX Carrier Ethernet Demarcation Device

Loop-IP6700 TDMoEthernet

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

OPERATION MANUAL INSTALLATION AND MPW-1. TDM Pseudowire Access Gateway. MP-4100 Version 2.0. The Access Company

ETX-204A Carrier Ethernet Demarcation Device

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

OPERATION MANUAL INSTALLATION AND ML-8E1, ML-8T1. 8-Port Main Link E1 and T1 Modules. Megaplex-2100/2104 Version 12. The Access Company

Megaplex-2100/2104 Modular Integrated Access Multiplexers

Installation and Operation Manual ML-IP. TDMoIP Main Link Module. MP-2100 Version 11 MEGAPLEX-2100 MODULE

Airmux-400, Airmux-5000 Optional Accessories

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

ISO 9001:2000 Certified Company

ETX-204A Carrier Ethernet Demarcation Device

16 x E1 G x Ethernet optical multiplexer

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

Transcription:

IPmux-11 DESCRIPTION FEATURES TDMoIP CPE (Customer Premises Equipment) for the small and medium-sized enterprise sites, offering TDM leased line extension over a packet switched network and controlled Ethernet access TDMoIP technology, implementing the emerging IETF, MPLS/FR Alliance, ITU-T and MEF standards for Pseudo-Wire Emulation Edge-to-Edge (PWE3): E1/T1 communication over IP and Ethernet networks Support for both framed (full or fractional) and unframed E1/T1 Minimal processing delay Configurable jitter buffer to compensate for network packet delay variation Dedicated external clock port QoS support by labeling IP level priority Type of Service (ToS) and VLAN tagging/priority labeling according to IEEE 802.1p&Q Three Ethernet ports, two for user side and one for network access The user Ethernet ports offer: Transparent Ethernet bridging User data bandwidth and access control through rate limiting and VLAN filtering VLAN classification through double VLAN tagging (stacking) Management via ASCII terminal, Telnet host, Web terminal or SNMP-based network management station Provisioning and monitoring of TDMoIP services using the RADview Service Center for TDMoIP applications Compact, 1U high enclosure IPmux-11 is a TDMoIP gateway optimized for small and medium-sized enterprise sites. It offers Ethernet-based access, as well as extension of TDM-based legacy services over packet switched networks. ETHERNET CAPABILITIES IPmux-11 s internal Layer-2 Ethernet switch supports three Ethernet ports. One port serves as a network interface and the other two serve for user Ethernet traffic. Each Ethernet port supports: Configurable port-based rate limiting for bandwidth control Configurable port-based VLAN membership for ingress traffic restriction Configurable port-based VLAN tagging; a VLAN tag is added resulting in a double tagging (VLAN stacking) when an already tagged frame is switched. The device supports standard IP features, such as ICMP (ping), ARP, next hop and default gateway.

IPmux-11 TDMoIP PERFORMANCE IPmux-11 provides a legacy over Ethernet/IP solution supporting transmission of E1/T1 streams over IP and Ethernet-based networks. IPmux-11 converts the data stream from its user E1/T1 port into packets for transmission over the network. The addressing scheme of these packets is IP or MPLS. These packets are transmitted via the IPmux-11 Ethernet link port to the network. A remote IPmux converts the packets back to TDM traffic. High-performance buffering and forwarding techniques are used to achieve end-to-end processing delay as low as 3 msec. Packet size is configurable. A greater packet length results in greater processing delay, yet smaller bandwidth overhead is achieved. An enhanced buffering mechanism compensates for packet delay variation (jitter) of up to 300 msec in the network. Assigned, IANA-registered UDP socket number for TDMoIP simplifies flow classification through switches and routers. TDMoIP QoS SUPPORT IPmux-11 supports VLAN tagging and priority labeling according to 802.1p&Q. TDMoIP frames are assigned (tagged) a dedicated VLAN ID. The ToS or Diffserv of the outgoing TDMoIP frames are user-configurable. This allows the TDMoIP packets to be given a higher priority by the network switches and routers. TDMoIP TIMING Synchronization between TDM devices is maintained, by deploying advanced clock distribution mechanisms. The clocking options are: Internal the master clock source for the TDM circuit is provided by the IPmux-11 internal clock oscillator Loopback the transmit clock is derived from the E1/T1 port s receive clock Adaptive the clock is recovered from the Ethernet network interface External an external clock source to synchronize the device via its station clock port. ETHERNET INTERFACE IPmux-11 supports the following Ethernet ports: One network port (UTP or fiber optic) Two user ports (both UTP or UTP and fiber optic). The network and user ports provide autonegotiation, VLAN tagging and rate limiting. TDM INTERFACE One standard E1 or T1 port provides connectivity to any standard E1 or T1 device. E1 and T1 interfaces support the following: Integral LTU/CSU for long haul applications E1 balanced and unbalanced or T1 options G.703 unframed and G.704 framed modes CAS and CRC-4 bit generation (E1) D4/SF and ESF framing (T1). APPLICATIONS Figure 1. LAN and TDM Services over a Fiber Optic Ethernet Link

DIAGNOSTICS IPmux-11 supports remote and local loopback testing. Alarm detection and insertion are supported together with error statistics. These include SES/UAS statistics, LOS/AIS physical layer alarms, and remote/local loopback test modes. Standard E1 or T1 alarms are transmitted end-to-end. The following physical layer alarms are supported: E1/T1 port LOS, AIS, LOF, LCV. IPmux-11 performs an internal built-in test (BIT) after power up. The results of the test are visible via the local terminal. IPmux-11 monitors LAN and IP layer network condition statistics, such as packet loss and packet delay variation (jitter). The events are stored in log files. Fault isolation, statistics and event logging are available. The minor and major alarms can be relayed to a remote alarm device via dedicated pins of the external clock RJ-45 connector. MANAGEMENT IPmux-11 can be configured and monitored locally via an ASCII terminal, or remotely via Telnet, Web browser or RADview. Management traffic can run over a dedicated VLAN. The RADview Service Center and Element Manager packages control and monitor TDM over IP (TDMoIP) devices and circuits. The Service Center s intuitive GUI, point-and-click functionality and easy-to-follow wizards increase the efficiency and accuracy of the service provisioning process. Software download is supported via the local terminal, using XMODEM, or remotely, using TFTP. After downloading a new software version, IPmux-11 automatically saves the previous version in non-volatile memory for backup purposes. Similarly, copies of the configuration file may be downloaded and uploaded to a remote workstation for backup and restore purposes. SPECIFICATIONS E1 INTERFACE ITU-T Rec. G.703, G.704, G.706, G.732, G.823 2.048 Mbps Line Code HDB3 Framing Unframed, CRC-4 MF, CAS MF Signaling CAS, CCS (transparent) Line Impedance Balanced: 120Ω Unbalanced: 75Ω Signal Levels Receive: 0 to -36 db with LTU 0 to -10 db without LTU Transmit balanced: ±3V ±10% Transmit unbalanced: ±2.37V ±10% Jitter Performance Per ITU-T G.823 Balanced: RJ-45 Unbalanced: RJ-45 (RJ-45 to BNC adapter cable is supplied) Figure 2. LAN and TDM Services over a Wireless Ethernet Link

SPECIFICATIONS E1 INTERFACE Number of Ports One ITU-T Rec. G.703, G.704, G.706, G.732, G.823 2.048 Mbps Line Code HDB3 Framing Unframed, framed, multiframe; with or without CRC-4 Signaling CAS, CCS (transparent) Line Impedance 120Ω, balanced 75Ω, unbalanced Signal Levels Receive: 0 to -36 db with LTU (long haul) 0 to -10 db without LTU (short haul) Transmit balanced: ±3V ±10% Transmit unbalanced: ±2.37V ±10% Jitter Performance Per ITU-T G.823 Balanced: RJ-45 Unbalanced: RJ-45 (RJ-45 to BNC adapter cable is supplied) Wavelength [nm] Fiber Type [µm] 1310 62.5/125 multimode 1310 9/125 single mode T1 INTERFACE Number of Ports One ANSI T1.403, ITU-T Rec. G.703, G.704 1.544 Mbps Line Code B8ZS, B7ZS, AMI Framing Unframed, SF, ESF Signaling CAS (bit robbing), CCS (transparent) Line Impedance 100Ω, balanced Signal Levels Receive: 0 to -36 db Transmit pulse amplitude: ±3V ±20%; 0 db, -7.5 db, -15 db, 22.5 db (CSU), user-selectable ±2.7V ±10%, 0 to 655 feet, (DSU), user-selectable Jitter Performance Per AT&T TR-62411, ITU-T G.824 RJ-45 Table 1. Fiber Optic Interface Characteristics Transmitter Type Power [dbm] Receiver Sensitivity [dbm] Loss [db/km] Min Max Min Max IPmux-11 ETHERNET INTERFACE IEEE 802.3, 802.3u, 802.1p&Q Number of Ports Network: one, UTP or fiber User: up to two, UTP only UTP: 10 Mbps or 100 Mbps, full or half duplex Fiber: 100 Mbps full-duplex Budget [dbm] LED -19-14 -32 1 4 10* LC Laser -15-8 -34 0.5 0.8 13* LC * Permitted fiber optic cable length differs according to fiber characteristics, splices, and connectors. Optical Budget Calculation: Optical Budget [db] = Receive Sensitivity Optical Power 3 (Aging) Connectors & Patch Panels Loss Distance Calculation: Min Distance = Optical Budget/Maximum Loss Max Distance = Optical Budget/Minimum Loss Connector Type

IPmux-11 Figure 3. Corporate Multisite Communication over a Packet-Switched Network Figure 4. IPmux-11 Providing Ethernet in the First Mile

IPmux-11 BUNDLES Number of TDM Bytes 48 1440 TDM bytes per Ethernet frame Destination IP Address User-configurable Jitter Buffer Size Up to 300 msec MANAGEMENT PORT Interface V.24 (RS-232), DCE 9.6, 19.2, 38.4, 57.6, or 115.2 kbps 9-pin, D-type, female GENERAL Timing Internal External (E1 or T1, via dedicated port) Loopback Adaptive Loopbacks E1/T1 local loopback E1/T1 remote loopback Statistics E1/T1 (per G.826 and RFC 2495) Ethernet (per RFC 2819) Receive buffer indication (overflow, underflow, sequence error) Alarm Relay Port Dry contact via pin 6, pin 7 and pin 8 of the EXT CLK RJ-45 connector. Operates as Normally Open and Normally Closed, using different pins. Indicators PWR (green) Power ALM (red) Alarm TST (red) Test is in progress E1/T1 SYNC (green) E1/T1 synchronization LINK/ACT (green) Ethernet link/activity status Power AC/DC: 100 240 VAC or -40 to -72 VDC Power Consumption 10W max Physical Height: 43.7 mm / 1.7 in Width: 240.0 mm / 9.4 in Depth: 170.0 mm / 6.7 in Weight 0.5 kg / 1.1 lb Environment Temperature: 0 50 C/32 122 F Humidity: Up to 90%, non-condensing ORDERING IPmux-11/*/&/% TDMoIP gateway * Specify TDM interface type: E1 for balanced E1 interface E1CX for unbalanced E1 interface (via supplied adapter cable) T1 for T1 interface & Specify network Ethernet interface type: UTP for 10/100BaseT interface, RJ-45 connector MM13LC for multimode 1310 nm 100BaseFx interface, LC connector SM13LC for single mode 1310 nm 100BaseFx interface, LC connector % Specify UTP for 10/100BaseT user interface, RJ-45 connector RM-33 Hardware kit for mounting one IPmux-11 unit into a 19-inch rack data communications www.rad.com International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: (972) 3-6458181 Fax: (972) 3-6498250, 6474436 Email: market@rad.com U.S. Headquarters 900 Corporate Drive Mahwah, NJ 07430 Tel: (201) 529-1100 Toll free: 1-800-444-7234 Fax: (201) 529-5777 Email: market@radusa.com 352-100-11/04 1988 2004 RAD Data Communications Ltd. Specifications are subject to change without prior notice. The RAD name, logo and logotype, the terms TDMoIP and TDMoIP Driven are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.