Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Similar documents
Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Products Portfolio. Pole mounted Vacuum Recloser

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Elastimold Molded Vacuum Recloser - MVR

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Reyrolle Protection Devices. 7SR210 & 7SR220 Argus Overcurrent Protection Relay. Answers for energy

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

A low-cost, economical solution for distribution feeder protection

Bus Bar Protection Relay B-PRO 4000

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

(1) Description of Operation 7SR224 Recloser Controller

Reyrolle Catalogue Answers for Energy

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

Lightweight and flexible recloser control for single-phase applications

7SR11 and 7SR12 Description of Operation

NU-LEC. Loop Automation. Reclosers & Sectionalizers

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

7SR11 and 7SR12 Argus Overcurrent Relays Answers for infrastructure & cities.

Firmware. Control Cable Interface

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Siprotec 7ST61 / 7ST63

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

Content REF615 Technical Presentation

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Perfect protection smallest space

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Advanced distribution feeder solution with integrated protection, monitoring, and control

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Reyrolle Protection Devices. 7SR242 Duobias Transformer Protection Relay. Energy Management. Unrestricted

7SR21 & 7SR22 Argus Overcurrent Relay Energy Management

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

VisoVac padmount fault interrupter

7SR210 & 7SR220 Argus Overcurrent Protection Relay Energy Management

High-speed transformer differential protection for up to five terminals

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SACE Emax 2 Specification guide

S&C 6801M Automatic Switch Operator

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

7SR210 & 7SR220 Argus Overcurrent Protection Relay Energy Management.

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

Reyrolle Protection Devices. 7SR10 Argus Overcurrent and Earth Fault Relay

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

7SR11 and 7SR12 Argus Overcurrent Relays Energy Management

MiCOM P521. Fast feeder differential protection

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

DRTS 33. The new generation of advanced three phase relay test set

Feeder/ Motor Protection Relay VAMP 40

Protection relays.

Effective May 2018 Supersedes October 2017

GE Multilin 350 Feeder Protection Relay Specifications

SIEBREAK-VCB 5-15 kv metal-enclosed interrupter switchgear usa.siemens.com/siebreak

MiCOM P122C Time-Overcurrent Protection

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

2 ms arc-flash protection and feeder relay in one platform

7SR18 Solkor Line Differential Protection Energy Management

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Protect induction and synchronous motors with one relay.

MiCOM P521. Fast Feeder Differential Protection

7SR242 Duobias Transformer Protection Relay Answers for energy.

Reyrolle Protection Devices. 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection with integrated Overcurrent Guard. Answers for energy

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

MiCOM P14x AREVA T&D. Feeder Management Relays

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

PRODUCT GUIDE. RER620 Advanced recloser protection & control

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

Substation Automation Products. Line differential protection RED670 Relion 670 series

Instruction manual. Type SDR 15.5 kv to 27 kv single-phase distribution recloser. Answers for infrastructure.

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

DRTS 66 can test all the following relays

Protection relay for secondary distribution

Maximize process uptime with the SEL-patented motor thermal model.

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Trident and Trident X2 Digital Process and Temperature Panel Meter

Transcription:

Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Overhead switching products Brochure Your outdoor overhead distribution solution provider 2

Brochure Overhead switching products Table of contents Type SDR distribution recloser 04 05 Type SDR distribution recloser controller options 06 08 Type B-2 recloser bypass assembly 09 10 3

Overhead switching products Brochure Type SDR distribution recloser Siemens, a leader in digital protection technology, with 30+ years of experience in vacuum switching technology, has combined cuttingedge technology with quality engineering in relay protection schemes to create our type SDR recloser offering. Features and benefits 15.5 kv, 27 kv, and 38 kv ratings Factory engineered, pre-installed, and wired accessories available for ease of onsite installation Advanced vacuum interruption technology Fully integrated current transformers (CTs) and resistive voltage sensors Self-monitoring Dual-coil, low-energy magnetic actuator USB communications port Three-phase recloser Single-phase recloser Triple-single operation modes Three-phase trip/three-phase lockout One-phase trip/three-phase lockout One-phase trip/one-phase lockout Advanced Siemens controller Fully withdrawable controller Customized and intuitive Human Machine Interface (HMI) with programmable buttons, indicators, and logic Extended warranty available. Type SDR single-phase recloser Type SDR three-phase recloser Type SDR triple-single recloser 4

Brochure Overhead switching products Technical data Item Description Rated continuous current 630 A; 800 A Rated voltage according to ANSI/IEEE C37.60 15.5 kv; 27 kv; 38 kv Recloser sequence O-T-CO-T-CO-T-CO lockout T individually settable 0.2-14,400 s Opening time 30 ms Closing time 60 ms Number of switching cycles 10,000 Number of short-circuit operations Up to 200; 116 according to ANSI/IEEE C37.60 duty cycle Number of phases Three-phase, single-phase, triple-single Ratings Rated voltages kv Interrupting current ka sym Lightning-impulse withstand voltage kv Continuous current 630 A 800 A 15.5 12.5 110 15.5 16 110 27 12.5 125 27 12.5 150 27 16 150 38 12.5 170 38 16 170 5

Overhead switching products Brochure Controller options For the type SDR distribution recloser The SDR controller constitutes the brains of the recloser. It comprises indicators and control elements, communication interfaces and a USB port for convenient connection of a laptop computer. Access to the user level menus and data is protected by multi-level password authentication. Type 7SR224 control and protection relay (three-phase and single-phase) Along with overcurrent time protection (up to 49 preset curves and multiple user-configurable curves), it is equipped for ground fault and sensitive ground fault detection. Inrush restraint and load shedding are further protection functions that help prevent nuisance outages. Convenience: Fully withdrawable type 7SR control and protection relay Ease of maintenance Complete system monitoring Tri-color programmable LEDs USB port (front of controller) 48-hour battery UPS Loop automation Integrated current transformers (CTs) and optional resistive voltage sensors in recloser switch unit Single-phase, three-phase and triple-single reclosers available Fully programmable from front panel Customizable and intuitive Human Machine Interface (HMI) with programmable buttons, indicators and logic Optional docking station for remote programming. Type 7SR224 control and protection relay (triple-single) Type 7SC80 feederautomation controller Operation: Relay protection Local/remote control Monitoring/SCADA of various protocols Power metering Event log Multiple communication protocols Input and output logic bits. Siemens SIPROTEC type 7SC80 feeder-automation controller Providing exceptional flexibility and responsiveness, the SIPROTEC 7SC80 feeder-automation controller offers so much more than a standard recloser controller. With GOOSE messaging and native IEC 61850, the 7SC80 is capable of coordinating a distribution network reconfiguration in less than 100 milliseconds. When coupled with the Siemens SDR recloser, Siemens SIPROTEC 7SC80 delivers the ultimate in feeder automation. 6

Brochure Overhead switching products Optional Schweitzer Engineering Laboratories, Inc. control relays The SDR controller is available with optional SEL control relays for use with type SDR reclosers. The type SEL-351R option utilizes the relay outputs to signal the type SDR controller 48 Vdc switch unit driver (PCB2) electronics and capacitors (PCB3) to control the three-phase type SDR recloser. The four 12 Vdc batteries are charged and monitored by the uninterruptible power supply (UPS) charge controller. Two additional 12 Vdc batteries provide the 24 Vdc control power for the type SEL-351R relay. Both the SEL-351RS Kestrel and SEL-651R options are equipped with internal power supply modules. These modules utilize their own internal electronics and capacitors which directly control the type SDR recloser operation. Two 12 Vdc batteries provide the control power for each of these options. All SDR controllers are available with customized accessories and device-mounting provisions upon request. Type SEL-351RS Kestrel: Single-phase trip and reclose operation Vertical relay orientation Secondary voltage input 300 Vac maximum Painted ANSI 61 steel control enclosure standard, 304 brushed stainless steel optional Three-point latch standard GFCI duplex outlet provided for laptop power. Type SEL-351R: Three-phase trip and reclose operation Vertical relay orientation One or four secondary voltage inputs 300 Vac maximum Painted ANSI 61 steel control enclosure standard, 304 brushed stainless steel optional Three-point latch standard Ground fault circuit interrupter (GFCI) duplex outlet provided for laptop power. Type SDR distribution recloser controller with optional SEL control relay (horizontally oriented) Type SEL-651R: Three-phase or triple-single trip and reclose operation Vertical relay orientation standard; horizontal relay orientation optional Available secondary voltage input options: Six 300 Vac maximum Three 1M Lindsey SVMI LEA and three Siemens type SDR recloser LEA Three 300 Vac maximum and three Siemens type SDR recloser LEA Three 300 Vac maximum and three 1M Lindsey SVMI LEA. Painted ANSI 61 steel control enclosure standard, 304 brushed stainless steel optional Three-point latch standard GFCI duplex outlet provided for laptop power. Type SDR distribution recloser controller with optional SEL control relay (vertically oriented) 7

Overhead switching products Brochure Controller functionality Protection functions Item Description 27/59 Under/overvoltage 37 Undercurrent 46BC Broken conductor/load unbalance 46NPS Negative phase-sequence overcurrent 47 Negative phase-sequence (NPS) voltage 49 Thermal overload 50 Instantaneous overcurrent 50BF Circuit breaker failure 50G/N Instantaneous ground fault 51 Time-delayed overcurrent 51c Cold-load pickup 51G/N Time-delayed measured ground fault/sef 51V Voltage-controlled overcurrent 59N Neutral-voltage displacement 60CTS CT supervision 60VTS VT supervision 64H High-impedence restricted-earth fault (REF) 67/50 Bi-directional instantaneous overcurrent 67/50/G/N Bi-directional instantaneous ground fault 67/51 Bi-directional time-delayed overcurrent 67/51/G/N Bi-directional time-delayed ground fault 67/51/SEF Directional time-delayed sensitive-ground fault 74TC Trip-circuit supervision 79 Auto-reclose 81HBL2 2 nd harmonic block/inrush restraint 81 Under/over frequency 86 Lockout User-programmable logic via HMI Eight settings groups with two levels of password access (four on single-phase model) Self-monitoring Measuring functions Description Primary current phase and ground Secondary current phase and ground Positive phase-sequence (PPS) current Negative phase-sequence (NPS) current Zero phase-sequence (ZPS) current Binary input/output status Trip circuit healthy/failure Time and date Fault records Event records Frequency Waveform records Recloser trip counter I 2 t summation for contact wear Direction Primary line and phase voltage Secondary voltage Apparent power and power factor Real and reactive power W Hr forward and reverse VA Hr forward and reverse Historical demand record Positive phase-sequence (PPS) voltage Negative phase-sequence (NPS) voltage Zero phase-sequence (ZPS) voltage Optional functions; three-phase and triple-single models only Item Description Supported protocols Item IEC 60870-5-103 Modbus RTU DNP 3.0 IEC 60870-5-101 (optional with Ethernet port) IEC 61850 (optional with Ethernet port) Description Front USB port Rear RS485 port Rear RS485 port Rear RS485 port Rear RS485 port Triple-single Fault locator 25 synchronism check Triple-single/singlephase auto-reclose Loop automation by loss of voltage uses an additional set of resistive voltage sensors and has the added functions: 27/59: Second under/overvoltage 60VTS Second VT supervision. Additional data communications ports (optional) Description; three-phase and single-phase models only Two rear standard fiber-optic ports and IRIG-B port Additional rear RS232 port and IRIG-B port Additional rear RS485 port and IRIG-B port Additional rear electrical Ethernet port RJ45 (quantity of two) Additional rear optical Ethernet duplex (quantity of two) 8

Brochure Overhead switching products Type B-2 recloser bypass assembly offers quick and easy installation. Maximize your up-time by adding a Siemens B-2 bypass assembly to your recloser installation. Our bypass assemblies give you the flexibility to take your recloser out of service without needing to take an outage or installing jumpers. Siemens type B-2 bypass assemblies safely bypass and isolate a recloser from the distribution system disrupting customers. Take control of choosing when you do maintenance, testing, or repair that minimizes disruption to your customers and eliminates any impact on system reliability. B-2 assembly - three-phase bypass Goals: Reduce downtime when maintenance is required Minimize installation time through pre-assembly. Benefits: Eliminate downtime for maintenance Ease of installation Lower installation costs Shorter installation time Reduced complexity of installation Single point lifting Pre-assembled Terminations oriented to cable angles Rapidly restore power in the event of equipment failure Easily ensure service continuity while doing maintenance or service work on the recloser. 9

Overhead switching products Brochure Three-phase bypass Series Maximum nominal voltage kv Basic insulation level kv 2913 15 110 600/900 2913 25 150 600/900 2913 38 200 600/900 B-2 switch- single-phase, three pull bypass Continuous current A Originating from the reliable B-2 singlephase Bridges Electric switch, all three-phase units ship pre-assembled on the crossarm for easy installation at the site, which reduces time and overall installation costs. A B-2 bypass assembly is customizable with porcelain or polymer insulators and galvanized or fiberglass bases. The assembly provides a means for bypassing and disconnecting pole-mounted reclosers. Proper sequence operation allows the recloser to be bypassed and isolated from the system. Features and benefits: 15.0 kv, 25.0 kv and 38.0 kv nominal voltage ratings Factory installed on galvanized or fiberglass arm Adjustable pole gain provides angling option per field conditions Single- or double-point lift bracket Arm length 8 (2.4 m), 10 (3.0 m) or 12 (3.7 m) (custom phase spacing available) Customer terminal pad options to simplify terminal connections Easy identification of bypass blades in open or closed position Three-pull design Square copper-tube blades High-pressure coin silver contacts Load-break hooks available Left- or right-hand bypass blade Custom configurations available Coastal environment options Quick installation Factory adjusted. 10

Brochure Overhead switching products 11

Published by Siemens Industry, Inc. 2018. Siemens Industry, Inc. 99 Bolton Sullivan Drive Heber Springs, Arkansas 72543 For more information, including service and parts, please contact our Customer Support Center. Phone: +1 (800) 333-7421 usa.siemens.com/mediumvoltage Order No.: EMMS-B40062-01-4AUS Printed in U.S.A. 2018 Siemens Industry, Inc. The technical data presented in this document is based on an actual case or on as designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects. Actual results are dependent on variable conditions. Accordingly, Siemens does not make representations, warranties, or assurances as to the accuracy, currency or completeness of the content contained herein. If requested, we will provide specific technical data or specifications with respect to any customer s particular applications. Our company is constantly involved in engineering and development. For that reason, we reserve the right to modify, at any time, the technology and product specifications contained herein.