Zonal LED Indicators.

Similar documents
Internal Printer. Features.

The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Exp-007 unit connects directly to Remote Status Indicator units to provide 2 programmable 1-Amp rated, volt free, clean contact outputs.

16-Way Input 48-Way Output Card

Flasher PC Application

Product Data Sheet. Hochiki 8 Way I/O Card. Features

Ad-NeT Networking.

Product Data Sheet. BMS/Graphics Interface. Features

Ad-NeT Network. Product Data Sheet

Ad-NeT Networking. Product Data Sheet. Analogue Addressable Fire Peripheral. Features at a glance

LifeLine Series. User Guide Px-100 Lifeline Paging Control Panel

ipgateway The operation and functions described in this manual are available from Software Version Mx onwards.

Spare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders

SM2000 Videographic recorder Spare parts and upgrade kits

SM1000 Videographic recorder Spare parts and upgrade kits

The Single Dimmer Board

WARNING: Remove all power sources to the panel before installation. Leave the external and main power OFF until installation is complete.

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

Sirius 24 and 48 DMX Output Kit Installation and Operation Instructions

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

CPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief

REGARD mA output module. Installation, operation and maintenance

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

Spare Parts Catalog. EasyCoder F2, F4, and F4 Compact Industrial Printers

Digital Keypad Introduction

Wireless LAN board. EB069

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Web Site: Forums: forums.parallax.com Sales: Technical:

Networking. This application note describes how install and configure Mx-5000 Networks REV 01

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

V-9939C MICROPHONE ADAPTER

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Installation Manual for D244X Series 24-volt Power Supplies

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

MINERVA MX MX-Net Inter-Controller Network

9. Settings and Adjustments Switch Setting Chart Speech Levels Trades Clock Parts List 13

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

MX-Net Inter-Controller Network

Installation & User Manual V2.08

TTP-384M THERMAL TRANSFER / DIRECT THERMAL BAR CODE PRINTER

INSTALLATION INSTRUCTIONS

Smart Battery Box Owner s Manual & Safety Instructions

RFID Ready Option Rev.C

Opto-isolator board. EB035

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

TECHNICAL MANUAL. 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1

ARM programmer and daughter board

MINERVA MX MX-Net Inter-Controller Network

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

MAINSLINK MAINSLINK. Applications: Switched Live Cable Replacement. Thermostat Cable Replacement

Installation Instructions Model PSC-17C

Spare Parts List A4+M. Label Printer. Made in Germany

Conveyor Belt Alignment Switches from IDEM

Serial Interface Module

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

Royal RVV-500 (B) Retrofit Kit

FC724 Fire control panel

Sigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

Installation & User Manual

Installation Instructions

PowerFlex DC Stand-Alone Regulator (SAR) Power Interface Circuit Board

Coded Non-Contact Safety Sensor Eden OSSD

Basketball Shot Clock Set LX2180 Manual

Interfacing BU-70 Display Units and BU-100/BU-101 Panels

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

2-Way Wireless I/O Expander Installation Guide

Installation Instructions Model PSX-12

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

chipdisk/1000-ide KTD-S0050-C

User Guide. ICP 300 In-Cab Printer. Operation

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K )

V-9939B MICROPHONE ADAPTER

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

RF Wireless LED Remote Dimmer Controller Model: DIM Two Colors Dimmer / 6 Zones / 6 Options to save

FT724. Fire terminal. Cerberus PRO. FS720 series, IP6

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

ACTsmart2 Product Range Operating and Installation Instructions

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

SPMS SmartPage Messaging System

The Power Generation Display Unit is available in two sizes as described in the following table:

7409 K570. Generic Pinpad Mount. Kit Instructions. Issue B

eyeheight EM-4 AES audio option for playout user manual

PSM-2 POWER SUPPLY MODULE INSTRUCTIONS

MAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved

Sigma XT Ancillary Board (K588)

E2460GS Oscilloscope Upgrade Kit

IECEx Certificate of Conformity Annexe

660/960 Installation Guide

Guide for installers. METTLER TOLEDO MultiRange Explosion-protected weighing system with the ID7sx weighing terminal

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

ROBOT LINE TRACKING MOUSE KIT C-9801

Transcription:

Zonal LED Indicators The zonal LED indicator cards are a range of panel mounted peripheral modules that can be added to the MxPro 4 series of control panels. The cards are available in numerous configurations and provide individual indication of the zone(s) in fire. The units fully support the MxPro 4 systems DynamiX zoning facilities on networked or larger stand-alone systems and can be used to provide individual zonal LED indication at one location. The Mxp-024F and Mxp-025F are 20 zone units, which are fitted to the front display plate on an MxPro 4 series control panel. The Mxp-013-050F, Mxp-013-100F and Mxp-200F incorporate 50, 100 or 200 LED indicators respectively and are compatible with all of the MxPro 4 series multi-loop panels. The zone range on the 100 way card can be assigned using an on board DIL switch and multiple cards can be placed in banks to allow indication of up to 1000 zones using standard units. The cards are capable of simultaneously displaying all zones in a fire condition and incorporate a unique power saving feature to minimise the power drawn from the control panel in the event of a major fire. Several other options are also available within the MxPro 4 range for an application where indication of fire signals from zones in addition to the panels graphical display is required. These options include Advanced Mimic Units, graphics systems and printers. The operation and functions described in this manual are available from Software Version 4000-016-00 onwards.

Specifications & Ordering: Models, Sales Order Parts: Part No: Mxp-024F: Mxp-025F: Mxp-013-050: Mxp-013-100: Mxp-013-200: Spares: Mxs-024: Mxs-009-050: Mxs-009-100: 20 Zone LED Card and label fitted to a Mx-4100 control panel 20 Zone LED Card and label fitted to an Mx-4200, Mx-4400 or Mx-4800 50 Zone LED Card and label fitted to an Mx-4200, Mx-4400 or Mx-4800. 100 Zone LED Card and label fitted to an Mx-4200, Mx-4400 or Mx-4800 2x 100 Zone LED Cards and label fitted to an Mx-4200, Mx-4400 or Mx-4800 Replacement 20 Zone LED Card (PCB only) Replacement 50 Zone LED Card (PCB only). Replacement 100 Zone LED Card (PCB only). Applications / Limitations: The zone indicator card can be fitted to an MxPro 4 control panel to provide indication of the zone(s) in fire in addition to the panels graphical display. The LED will illuminate when the corresponding zone enters a fire condition. The 100 Zone LED card incorporates a DIL switch to set the zone range to be indicated from 1 to 1000. (E.g. 1 100, 101 200 901 1000). The 20 and 50 zone cards display zones 1 20 and zones 1 50 respectively. In the event of more than 50 zones entering a fire condition, the LED s will change from continuous to flashing in order to minimise the power drawn from the control panel. If an Mxp-012 on-board printer is fitted to a panel, and a zone indicator card is also required, use the Mxp-013-050, Mxp-013-100 or Mxp-013-200 modules. The Mxp-025 20 zone LED card cannot also be used. Compatibility: The Mxp-024F can be fitted to an Mx-4100 control panel. The Mxp-025F, Mxp-013-050F, Mxp-013-100F and Mxp-013-200F can be fitted to an Mx-4200, Mx-4400 or Mx-4800 control panel. All Zone Indicator cards are supported from panel software revision 16 onwards. Item Panel loading in Quiescent state Panel loading, all LEDS on Maximum Working Temperature Specification Details 3mA Mxp-024F / Mxp-025F Mxp-013-50F / Mxp-013-100F Mxp-013-200F 12mA 27mA 54mA 50 C As our policy is one of constant product improvement the right is therefore reserved to modify product specifications without prior notice

Table of Contents Page 1 INSTALLATION... 4 1.1 MXP-024F... 4 1.2 MXP-025F... 4 1.3 MXP-013-XXXF... 5 1.3.1 Mxp-013-050 / Mxp-013-100... 5 1.3.2 Mxp-013-200... 5 2 CONFIGURATION... 6 3 OPERATION:... 6 3.1 TESTING THE ZONAL LED INDICATORS... 6 3

1 Installation The Zonal LED Indicator Cards are normally factory fitted options. These instructions cover the installation, replacement and configuration of spare assemblies. Isolate ALL sources of power before installing or removing printed circuit boards. 1.1 Mxp-024F The Mxp-024F is mounted on the chassis fascia plate using 4x M3 screws. To replace a card: a) Unplug the ribbon cable from the LED card. b) Remove the 4x nuts and remove the card. Be careful not to lose the spacers. c) Fit the replacement card (Mxs-024) and fix in place with the 4x nuts. d) Re-connect the ribbon cable to the LED card. e) Test the LED operation (refer to Operation Section). Mxs-024 Display Card Interconnecting Cable 4x M3 Nut NOTE: If a network interface card (Mxp-003 or Mxp-009) is required and fitted, this is installed on top of the LED card using spacers. 1.2 Mxp-025F To replace a card: a) Unplug the ribbon cable from the LED card. b) Remove the 4x nuts and remove the card. Be careful not to lose the spacers. c) Fit the replacement card (Mxs-024) and fix in place with the 4x nuts. d) Re-connect the ribbon cable to the LED card. e) Test the LED operation (refer to Operation Section). Interconnecting Cable Display Card Mxs-024 4x M3 Nut 4

1.3 Mxp-013-XXXF The Mxp-013-050, Mxp-013-100 and Mxp-200 are mounted onto a fascia plate on the door. The cards are attached to the fascia plate using 6 nuts. 1.3.1 Mxp-013-050 / Mxp-013-100 To replace a card: a) Unplug the ribbon cable from the LED card. b) Remove the 6x nuts and remove the card. Be careful not to lose the spacers. c) Fit the replacement card (Mxs-013-050 or Mxs-013-100 as appropriate) and fix in place with the 6x nuts. d) Re-connect the ribbon cable to PL1 position. e) Check the configuration of the Zone range (refer to Configuration Section). f) Test the LED operation (refer to Operation Section). 1.3.2 Mxp-013-200 The Mxp-013-200 consists of 2x 100 LED Indicator cards mounted on the fascia plate and connected together using an interconnecting ribbon cable. To replace a card: a) Unplug the appropriate ribbon cable(s) from the LED card. b) Remove the 6x nuts and remove the card. Be careful not to lose the spacers. c) Fit the replacement card (Mxs-013-100) and fix in place with the 6x nuts. d) Re-connect the ribbon cable to the appropriate positions. e) Check the configuration of the Zone range (refer to Configuration Section). f) Test the LED operation (refer to Operation Section). 5

2 Configuration The Mxp-024 and Mxp-025 are pre-configured to show zone numbers 1 20. The Mxp-013 can be configured from a DIL switch to any of the zone ranges in the table below. DIL switch (SW1) settings 4 3 2 1 Zone Range (Note 1) Off Off Off Off 1-100 Off Off Off On 101-200 Off Off On Off 201-300 Off Off On On 301-400 Off On Off Off 401-500 Off On Off On 501-600 Off On On Off 601-700 Off On On On 701-800 On Off Off Off 801-900 On Off Off On 901-1000 On On On On Test Mode Notes: 1. Mxp-013-050 indicates the first 50 zones in each of the ranges. 3 Operation: When a zone changes state to a fire condition, the corresponding zone LED will illuminate. The Zone LED Indicators will be turned off when the panel is manually reset. The Mxp-013 incorporates a power saving feature so that in the event of a major fire with more than 50 zones all in a fire condition occurring in the same zone range, the zone LED s will change from being continuously on to flashing in order to minimise power drawn from the standby battery. 3.1 Testing the Zonal LED Indicators Enter the TEST menu and select DISPLAY. All of the zonal LED s will then flash on and off for several seconds. 6

USER NOTES

Doc Number: 680-036 Revision: First Issued: 03A 2013-mm-dd Advanced Electronics Ltd Moorland Way, Cramlington, Northumberland, NE23 1WE UK Tel: +44 (0)1670 707 111 Fax: +44 (0)1670 707 222 Email: sales@advancedco.com Web: