AB Axis Industries. Use

Similar documents
AEW Pulse Adapter. Building Technologies

AEW36.2. Pulse Adapter. Siemeca AMR

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

MID approval no. DE-08-MI004-PTB004 Date of release

ULTRASONIC WATER METER HYDROSONIS

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Blue ID Communication module RS485 SC44

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

M-Bus Central Unit. Use

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Communication module RS485 SC44

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Energy Management BUS Adapter Type VMU-B

Solenvis SL80 Pulse to M-Bus Converters

Faults on the system Proximity switch connection technology:

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

ABB i-bus KNX HCC/S Heating/cooling circuit controller

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

PI-EX-ME-2NAM/COC-24VDC

TM3TI4 module TM3-4 inputs temperature

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TM3AI4 module TM3-4 analog inputs

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

DM 161 S-DIAS Digital Mixed Module

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

AMBUS IS M-Bus pulse collector

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

TM3DI16G module TM3-16 inputs spring

XPSMCMDI Input expansion module with screw term

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

EY-EM : Remote I/O module, ecolink

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

PHOENIX CONTACT Features

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM3TI8T module TM3-8 inputs temperature

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

General information. Display. Supply voltage. Input current

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Compact Universal Controllers

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

02/11/2015

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Technical Information Fieldgate SFG500

Operating instructions. Standstill monitor A / / 2011

PHOENIX CONTACT - 12/2007

PADPULS2 M-BUS Pulse Input Modules

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Energy Management BUS Adapter Type VMU-B 01

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

PI-EX-ME-2NAM/COC-120VAC

Bluetooth to Serial Converter TOP FRONT. Click 421

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

TM3TI4 module TM3-4 inputs temperature

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

XPSMCMDO Digital output pairs expansion modules with screw term

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Operating and mounting instructions

Pneumatic Control Unit for the integrated mounting on process valves

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

TM3DI16 module TM3-16 inputs

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

SonoSelect and SonoSafe energy meters

ISE 021 S-DIAS Interface Module RS232 / RS485

Operating instructions. Switching amplifier DN0210 DN / / 2015

I/O module, universal, digital, S0 inputs, modu533

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TM238LFDC24DT compact base M I/O - 24 V DC supply - CANOpen - internal RAM 1000 kb

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Network nodes with gateway

Non-communicating room controllers

HOBO State Data Logger (UX90-001x) Manual

I/O module, digital and universal inputs, modu530

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TEPI11 P/I signal converter

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SonoSelect 10 and SonoSafe 10 energy meters

Transcription:

AB Axis Industries PULSE ADAPTER ENCO PULSE The ENCO PULSE pulse adapter acquires and handles the pulses from consumption meters with pulse output and transmits the data to a network of AMR system. Use The pulse adapter is a component of the AMR system. It is used when data of pulse output meters shall be collected by AMR system. Such devices can be meters for hot water, cold water, gas, electricity, etc. Functions Acquisition of the pulses delivered by the connected consumption meters 2015.04.21 AB Axis Industries Pulse adapter PA-1 1 (5)

Monitoring the connecting cable in the case of metering devices with NAMUR circuit Handling of pulses and storage of consumption data and set day values Transmission of data telegrams to the AMR system Ordering ENCO PULSE-MBus - Pulse adapter with integrated M-bus interface (Standard version). ENCO PULSE-RS - Pulse adapter with integrated 3V RxTx interface (special order). ENCO PULSE-RF - Pulse adapter with integrated RF 866MHz interface (special order). Technical data The pulse adapter handles only pulses from potential-free pulse sources, according with the following specification (depending on the programmed pulse source type): Pulse source Limit values (if parameters are appropriately set) Electronic outputs residual voltage when switched <0,7V (Open Collector, max. frequency <16Hz Open Drain) min. pulse width 30ms Mechanical bounce time <1ms switches max. frequency <2Hz min. pulse width 260ms Mechanical bounce time <1ms switches with max. frequency <2Hz NAMUR circuits min. pulse width 260ms Resistance R1 2,2 kώ Resistance R2 5,6 kώ Length of Total length of the connecting cable may not exceed 10 m. connecting cable Power supply Data transmission The pulse adapter is powered by a lithium battery 3,6V, which has a service life of 12 + 1 years. During the replacement of the battery, the adapter must be connected to the communication network. Data are transmitted inside M-Bus network (or3v RxTx network) to the central unit on demand 2015.04.21 AB Axis Industries Pulse adapter PA-1 2 (5)

CE conformity 2004/108/EB (EMC Directive) LST EN 55024:2000/A2:2003 LST EN 61000-4-3:2006/A1:2008 LST EN 61000-4-4:2005/P:2007 LST EN 61000-4 -5:2007. LST EN 61000-4 -11:2004/P:2007 Safety class III by EN60950 Degree of protection IP65 by EN 60 529 Ambient temperature: Operation 0...55ºC Transport and storage -25...60ºC Weight not more 0,3 kg Mounting Pulse adapter can be mounted on standard DIN-rail, in electrical cabinet or on vertical wall, using three screws. It must be installed at the nearest possible distance from the meters. It is forbidden to wire pulse cable and network cable nearby (less than 5 cm) with power cables or cables of other devices. Important: It is forbidden to attach the pulse adapter directly to a wall if there is a risk that on walls can be condensed humidity or temperature of a surface of a wall can fall lower than 5. In this case, it is recommended to attach the calculator so that between it and wall surfaces there were an air gap not less than 5 cm. Mounting on the wall: Mounting on standard DIN-rail in electrical cabinet: 2015.04.21 AB Axis Industries Pulse adapter PA-1 3 (5)

Turn down the fixers and remove the cover. According to the connection diagram connect up the adapter to the meter and to the communications network. Two-wire cable with cross-section 0,14 0,25 mm 2 should be used for connection. Cables should be run through rubber seal caps and anchored with clamps. Commissioning notes The pulse adapter must be programmed during installation. Only properly trained service personnel can set up the parameters of pulse adapter. The parameters can be set via M-bus (or 3V RxTx), using a PC with special software. Enter the following data: Connection diagrams Type of medium (gas, water, etc.) Physical variable (kwh, m3, etc.) Pulse value Type of pulse source (Electronic key, Mechanical switch, Mechanical switch with NAMUR) Set day Meter reading Meter number (identification number) 2015.04.21 AB Axis Industries Pulse adapter PA-1 4 (5)

Dimensions 2015.04.21 AB Axis Industries Pulse adapter PA-1 5 (5)