Operating instructions. Monitor FS-1 / FS-1N / / 2013

Similar documents
Operating instructions. Monitor FD / / 2013

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions. Speed monitor D / / 2014

Operating instructions Monitor FD-2 DR2005 DR / / 2007

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Standstill monitor A / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions Evaluation system for flow sensors VS / / 2013

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Operating instructions Optical distance sensor O1D / / 2008

Installation instructions Inclination sensor EC2019 EC / / 2013

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

Installation instructions Ethernet switch EC / / 2011

Operating instructions Control monitor for temperature sensors TR7439

Operating instructions Optical distance sensor. OID20x / / 2014

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating instructions Optical distance sensor. OID25x / / 2014

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions Photoelectric distance sensor OGD592 OGD593

Operating instructions Electronic pressure sensor PN7xxx

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

Operating instructions Optical distance sensor. O5D15x / / 2014

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions Electronic temperature sensor TN7511

Operating instructions Memory plug E /02 11/2011

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015

Original operating instructions Fail-safe inductive sensor GG711S

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

Original operating instructions Fail-safe inductive sensor GI712S

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Electronic digital pressure sensor EPS25-XXXX-1001

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Operating instructions AC010S Compact AS-i E-STOP safety module

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

02/11/2015

Operating Instructions

Operating instructions Electronic temperature sensor TN /00 04/2011

Quick reference guide 3D sensor O3D3xx

System manual AS-i safety monitor AC041S /00 05/2013

Geräte-Handbuch Device manual Notice pour utilisateurs

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Industrial motor controller for brushed DC motors 24 VDC

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Operating instructions Vortex flow meter. SVxxx / / 2015

Industrial motor controller for brushed DC motors 24 VDC

7415 x. Made in Germany. fluid sensors and diagnostic systems. position sensors and object recognition bus, identification and control systems

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Contact protection relay

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Operating instructions Pressure sensor. PN70xx / / 2012

AS-i Safety Relay Output Module with Diagnostic Slave

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Assembly and Operating Instructions. M2 module for BDC-i440 control units

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Operating Instructions Differential Pressure Transducer PS27

Operating instructions Programming and display unit PP / / 2010

Solid State Remote Power Controller E /627

OPERATING INSTRUCTIONS

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Operating Manual FPGA-based High-Speed Micro-PLC

Operating instructions Pressure sensor. PE30xx / / 2010

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

QUINT-BUFFER/24DC/24DC/40

Operating Instructions

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

DALI Professional Controller-4. Control unit Operating instructions

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Operating instructions Pressure sensor. PN70xx / / 2010

OPT2011. High-performance distance sensor. Operating Instructions

Transcription:

Operating instructions Monitor FS-1 / FS-1N UK 7390958 / 00 01 / 2013

Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5 2.3 Electrical connection...5 2.4 Operation...5 2.5 Installation location...6 2.6 Housing temperature...6 2.7 Tampering with the device...6 3 Functions and features...6 4 Operating and display elements...9 4.1 Display stand-by mode...10 5 Installation...10 5.1 Installation of the device...10 5.2 Installation of the sensors... 11 6 Electrical connection... 11 6.1 Terminal connection... 11 6.2 Voltage supply (power)... 11 6.2.1 AC supplies... 11 6.2.2 DC supplies...12 6.3 Inputs...12 6.3.1 Connection of the sensors (In1, 2)...12 6.3.2 Reset inputs (reset 1 and 2)...12 6.3.3 Typical input circuit F...-x...13 6.4 Outputs...14 6.4.1 Relay outputs (Out1, 2)...14 6.4.2 Transistor outputs (Out1, 2)...14 6.5 Additional outputs for NAMUR devices (F...-xN)...14 6.5.1 Fault outputs...14 7 Navigation and parameter overview...15 7.1 System parameters...16 2

7.1.1 FOx...16 7.1.2 SOx...16 7.1.3 FWx...17 7.1.4 NCx...17 7.1.5 EF1...18 7.1.6 MF1...18 7.1.7 DF1...18 7.1.8 DIM...19 7.1.9 VER...19 7.2 Application parameters...20uk 7.2.1 SPx...20 7.2.2 HYx...20 7.2.3 STx...21 7.2.4 DTx...21 7.2.5 FTx...21 8 Programming...22 8.1 Programming example DT1 (Delay Time, output 1)...22 8.2 Notes on programming...23 8.2.1 RUN mode...23 8.2.2 Time Out Function...23 8.2.3 Numerical entries...23 8.2.4 Factory Reset...24 8.2.5 KEY function (locking)...24 9 Test mode...25 9.1 Activate the test mode...25 9.2 Terminate the test mode...25 9.3 Test parameters...26 10 Scale drawing...27 11 Technical data...27 11.1 Overview...27 11.2 Approvals/standards...28 12 Maintenance, repair, disposal...28 This document is the original instructions. 3

1 Preliminary note This document is part of the device and contains information about the correct handling of the product. This document is intended for specialists. These specialists are people who are qualified by their training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device. Read this document before use to familiarise yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. Adhere to the warning notes and safety instructions. 1.1 Symbols used Instruction > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. 1.2 Warning signs used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. CAUTION Warning of personal injury. Slight reversible injuries may result. NOTE Warning of damage to property. 4

2 Safety instructions 2.1 General Follow the operating instructions. Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can affect the safety of operators and machinery. The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the device. 2.2 Target group The device must only be installed, connected and put into operation by a qualified electrician. UK 2.3 Electrical connection Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. Make sure that the external voltage is generated and supplied according to the requirements for safe extra-low voltage (SELV) since this voltage is supplied without further measures near the operating elements and at the terminals for the supply of connected sensors. The wiring of all signals in connection with the SELV circuit of the device must also comply with the SELV criteria (safety extra-low voltage, safe electrical isolation from other electric circuits). If the externally supplied or internally generated SELV voltage is externally grounded, the responsibility lies with the user in accordance with the applicable national installation regulations. All statements in this manual refer to the unit the SELV voltage of which is not grounded. It is not allowed to supply external voltage to the terminals for the pulse pick-up supply. The consumption of current which exceeds the value given in the technical data is not allowed. An external main switch must be installed for the unit which can switch off the unit and all related circuits. This main switch must be clearly assigned to the unit. 2.4 Operation Be careful when handling the unit once power is applied. This is only allowed by qualified personnel due to the protection rating IP 20. 5

The design of the unit corresponds to the protection class II except for the terminal blocks. Protection against accidental contact (finger protection to IP 20) for qualified personnel is only guaranteed if the terminal screw has been completely screwed in. 2.5 Installation location For the correct operation the unit must be mounted in a housing (protection rating IP 40 or higher) which can only be opened using a tool or in a locked control cabinet. The device has been tested for an impact energy of 1 joule according to EN61010. 2.6 Housing temperature As described in the technical specifications below the device can be operated in a wide ambient temperature range. Because of the additional internal heating the operating elements and the housing walls can have high perceptible temperatures when touched in hot environments. 2.7 Tampering with the device In case of malfunction of the unit or queries please contact the manufacturer. Any tampering with the device can seriously affect the safety of operators and machinery. This is not permitted and leads to the exclusion of any liability and warranty claims. 3 Functions and features The monitor FS-1 / FS-1N is a programmable pulse evaluation system for slip/ synchronous monitoring. It monitors the rotational speed ratio between drive (master) and power take-off (slave). It receives the pulses from 2 external sensors on 2 separate input channels, measures the pulse interval and calculates the input frequency. The device determines for example the deviation in percent between the input frequencies, compares them with the set switch point [slip in %] and switches output 1 according to the selected switching function. slip = (f IN2 - f IN1 ) f IN2 x 100 [%] 6

IN 2 IN 1 Master Slave 2 1 In 1 In 2 IN 1 IN 2 IN 2 MONITOR FS-1 UK Out 1 Out 2 3 4 Example 1: Slip/synchronous monitoring of a conveyor system 1: Pulse pick-up power take-off (slave) 2: Pulse pick-up drive (master) 3: Switching output 1, message slip or synchronous movement (IN 1 IN 2) 4: Switching output 2, message rotational speed not reached/exceeded or acceptable range (IN 2) In addition to the speed monitor function for the drive the device also provides monitoring of rotational speed exceeded/not reached, blocking, overload or jam, maximum or minimum rotational speeds, defined slip, synchronous movement and frequency ranges. The assignment of the pulses to the input channels is predetermined. IN 1 = power take-off (slave) IN 2 = drive (master) The frequency ratio IN 1 IN 2 is evaluated. The frequency ratio IN 1 > IN 2 cannot be evaluated. 7

Slave IN 1 IN 2 Master 1 2 In 1 In 2 IN 1 IN 2 IN 2 MONITOR FS-1 Out 1 Out 2 3 4 Example 2: Slip/synchronous monitoring of a slipping clutch 1: Pulse pick-up power take-off (slave) 2: Pulse pick-up drive (master) 3: Switching output 1, message slip or synchronous movement (IN 1 IN 2) 4: Switching output 2, message rotational speed not reached/exceeded or acceptable range (IN 2) WARNING The device is not approved for safety-related tasks in the field of operator protection. Using an electrical connection of the outputs from two or more units to achieve a redundant circuit, they can also be used for safety-related tasks. All applicable technical standards must be followed. 8

4 Operating and display elements 6 TST CH1 CH2 CH3 RUN PRG KEY 0.0.0.0.0 RPM 1 1a 1b 1c 1d 4 5 In1 In2 Out1 Out2 Enter 2 3 F...-xN (NAMUR) UK 1e 1f 1 OLED display 1a Indicators for input channels and operating modes CH... Input channels RUN Run mode (normal operating mode) TST Test mode (check of the switching characteristics without pulse pick-up connected) PRG Programming mode (setting of the parameter values) KEY Locking 1b Actual values and parameter values (5-digit, numerical) Slip 0.1...99.9 % Rotational speed 0...60,000 RPM Pulses 0.1...1,000.0 Hz Outside the value ranges the display shows "----". 1c Parameter abbreviation and units (3-digit, alphanumeric) 1d Display is in stand-by mode, no values visible ( 4.1) 1e Display in display mode Symbol for wire break/ short circuit on the cable of the pulse pick-up (only F...-xN) 1f Display in standby mode Symbol for wire break/ short circuit on the cable of the pulse pick-up (only F...-xN) 9

2 [ ] and [ ] buttons Selection of the actual value display, parameter selection, setting of the parameter values 3 [Enter/ ] button Selection of the operating mode, acknowledgement of the parameter value, front reset 4 LEDs In1/2 (yellow) Input pulse 5 LEDs Out1/2 (green) Switching status of the outputs 1 and 2 Off Output is not switched. (Relay de-energised, transistor blocked) On Output is switched.(relay energised, transistor switched) Flashing quickly Output is kept latched.(parameter SOx, Store Output) Flashing slowly 6 Panel for labelling F...-xN = device with NAMUR input The delay time has an effect on the output. The output switches when the delay time has elapsed and the trigger event is still present (parameter DTx, Delay Time). 4.1 Display stand-by mode If no button is pressed for more than 10 minutes, the device changes to the standby mode. and units are no longer visible. The stand-by mode can be identified by a flashing rectangle. Even if no values and units are visible, the device continues its monitoring function on the basis of the set parameters and switches the relay and transistor outputs accordingly. Press any button to switch the display on again. 5 Installation 5.1 Installation of the device Install the device on a 35 mm DIN rail. Leave enough space between the unit and the top and bottom of the control cabinet to enable air circulation and to avoid excessive heating. Take into account the internal heating of all units when mounting several units side by side. The environmental conditions must be observed for every unit. 10

5.2 Installation of the sensors Follow the manufacturer s installation instructions. 6 Electrical connection 6.1 Terminal connection Monitor FS-1 Monitor FS-1N Power AC or DC Power AC or DC 7 8 1 2 7 8 1 2 L N L N 5 Sensor 5 Sensor 3 supply 6 supply 16 I<0,1mA In 1 4 pnp Out 1 In 1 I>6,0mA 15 10 npn 13 6 Sensor 11 pnp supply 14 In 2 12 npn 11 Sensor supply 24 21 Out 2 I<0,1mA In 2 I>6,0mA 19 20 12 Sensor supply Reset 1 Reset 2 17 pnp 18 pnp Reset 1 Reset 2 17 pnp 18 pnp 3 4 16 15 13 14 10 24 21 19 20 Out 1 Out 2 UK Terminal connection WARNING Do not use unconnected terminals such as terminal 9 as support point terminal. 6.2 Voltage supply (power) Voltage supply see type label. The device may only be operated using one of the possible voltage connections, i.e. either terminals 7/8 (AC) or terminals 1/2 (24 V DC). All supply and signal cables must be laid separately. Use a screened cable if required in the application. 6.2.1 AC supplies The AC supply cable must be protected according to the cross-section used (max. 16 A). If the unit is supplied on AC, the low voltage provided for the sensor supply meets the SELV criteria according to EN 61010, overvoltage category II, soiling degree 2. 11

6.2.2 DC supplies The SELV criteria (safety extra-low voltage) must be met for the DC supply. The DC supply cable L+ (terminal 2) must be protected externally with a 315 ma T fuse (5 x 20 mm or similar). The DC supply terminals are directly connected to the sensor supply terminals. 6.3 Inputs 6.3.1 Connection of the sensors (In1, 2) DC PNP to FS-1 DC NPN to FS-1 AC/DC to FS-1 BN BK BU 5 BN 5 4/ 11 BK 10/ 12 6 BU 6 BN BU 5 4/ 11 DC quadronorm to FS-1 NAMUR up to 25 V to FS-1 NAMUR 8.2 V to FS-1 N WH 5 BN 10 BN 6 / 12 / 12 BK 4/ 11 BU 6 BU 5/ 11 Connection of the sensors The connection of mechanical switch contacts is not recommended since they tend to bounce and produce faulty pulses. The terminals 5/6 can be used for the sensor supply or for the reset inputs (only F...-x). 6.3.2 Reset inputs (reset 1 and 2) The start-up delay can be started or a saved error can be reset via the reset inputs (terminals 17/18). The internal +24 V DC voltage (terminal 5) or an external +24 V DC voltage is connected with terminal 17 or 18 via a closing contact. Reset for output 1 = terminal 17 Reset for output 2 = terminal 18 If an external voltage is used, the negative reference point of this voltage must be connected to terminal 1 of the monitor. When the contact is opened (+24 V DC no longer applied), the start-up delay or the memory reset starts. 12

A +24 V DC continuous signal leads to a permanent bridging of the monitoring, i.e. the same state as during the start-up delay is indicated. When the voltage is no longer applied and the set start-up delay has elapsed, monitoring starts. Note on F...-xN: The +24 V DC signal voltage required for the reset inputs is not available to the F...-xN. This must be taken from an external voltage source. The reference point (GND) of the external power supply must be connected to terminal 1 of the monitor; otherwise no switching operation is possible. 6.3.3 Typical input circuit F...-x UK + sensor supply 70E U BB (24 V) ϑ 47n 2K2 npn 270E 4K7 10K 1n0 4K7 10n0 pnp 270E 10K 1n0 2K2 4n7 - sensor supply 13

6.4 Outputs 6.4.1 Relay outputs (Out1, 2) To prevent excessive wear and to comply with the EMC standards, interference suppression of the contacts is required for switching inductive loads. WARNING If the device is operated on an AC supply (terminals 7/8) this must use the same supply cable as the voltage supply to switch an AC voltage via the relay outputs. If the relay outputs are used for switching very small currents (e.g. PLC inputs), considerable contact resistance can arise. In this case use the transistor outputs. 6.4.2 Transistor outputs (Out1, 2) The transistor outputs need an external voltage of +24 V DC on terminal 3. Connect the reference point (GND) of the external power supply to terminal 1 of the monitor. Otherwise no switching operation is possible. The SELV criteria (safety extra-low voltage) must be met for the DC supply of the transistor outputs. The DC supply cable L+ (terminal 3) must be protected externally with a 315 ma T fuse (5 x 20 mm or similar). 6.5 Additional outputs for NAMUR devices (F...-xN) 6.5.1 Fault outputs The fault outputs (terminals 4/10) indicate a wire fault between the monitor and the respective pulse pick-up (wire break/short circuit). In case of a fault the respective output is blocked. Wire fault input 1 = terminal 4 Wire fault input 2 = terminal 10 14

7 Navigation and parameter overview The pushbuttons [ ] / [ ] and [Enter/ ] are used for the navigation, entry of values and acknowledgement within the parameters arranged in columns. RUN mode Parameter range and PRG mode VER DIM DF1 UK 1 Input 1 [RPM/Hz] MF1 EF1 NC1 NC2 2 Input 2 [RPM/Hz] FW1* SO1 FO1 FW2* SO2 FO2 A 4 3 SP1 SP2 IN1 IN2 [%] HY1 ST1 HY2 ST2 B DT1 DT2 FT1 FT2 1: Indication: actual value input 1 (slave) 2: Indication: actual value input 2 (master) A: System parameters B: Application parameters *) only F...-xN 3: Indication: slip 4: Back to the RUN mode 15

7.1 System parameters 7.1.1 FOx Function Output (switching function of the outputs 1/2) 1 Relay energised (transistor switched) when the current value is below the switch point SPx (= signalled state OUT1 "synchronous movement"; OUT2 "drive below preset value") 2 Relay de-energised (transistor blocked) when the current value is below the switch point SPx (= error message OUT2 "drive underspeed"; not useful for OUT1) 3 Relay energised (transistor switched) when the current value is above the switch point SPx (= signalled state OUT2 "drive speed reached"; not useful for OUT1) 4 Relay de-energised (transistor blocked) when the current value is above the switch point SPx (= error message OUT1 "slip"; OUT2 "drive overspeed") 5 Relay is energised (transistor switched) within a frequency range (acceptable range) 6 Relay is de-energised (transistor output blocked) within a frequency range. With the functions 5 and 6 a frequency range above and below the switch point SPx is defined in connection with the parameter HYx (hysteresis). Functions 5 and 6 are not useful for output 1 (FO1)! 1...6 Default settings FO1 = 4 (output 1; error message "slip"; recommended) FO2 = 2 (output 2; error message "drive underspeed") 7.1.2 SOx Store Output (latching function outputs 1/2) When this parameter is active, the respective output does not switch back automatically but must be reset. 0 = inactive 1 = front reset ([Enter/ ] > 3 s) 2 = front reset and external reset Default settings 0 (inactive) 16

7.1.3 FWx Function Wire Break Monitoring (only F...-xN) Relay characteristics for wire fault or short circuit, i.e. input frequency = 0 Output 1 (slip/synchronous monitoring) if FW1 = inactive (0) FW1 = active (1) slip > switch point SPx for switching functions 1 and 4 relay de-energised relay remains de-energised slip < switch point SPx for switching functions 1 and 4 relay remains energised relay de-energised UK Output 2 (drive: frequency, rotational speed) if FW2 = inactive (0) FW2 = active (1) frequency > switch point SPx for switching functions 1 and 4 relay energised relay remains de-energised for switching functions 2 and 3 relay de-energised relay de-energised frequency < switch point SPx for switching functions 1 and 4 relay remains energised relay de-energised for switching functions 2 and 3 relay de-energised relay remains de-energised frequency in the window range for switching function 5 relay de-energised relay de-energised for switching function 6 relay energised relay de-energised 0 = inactive 1 = active Default settings 0 7.1.4 NCx Number of Cams (on inputs 1/2) Number of cams detected per revolution. On the basis of this value the monitor calculates the rotational speed (measured frequency NCx = displayed speed in RPM). For frequency measurements NCx = 1 should remain set. 1...999 Default settings 1 17

7.1.5 EF1 Enable Frequency (slip monitoring becomes active above EF1) This function is used as time-independent start-up delay (cf. STx). For applications where the driven side could become jammed during start-up (e.g. grinding gear). Output 1 (slip monitoring) is maintained in the "good" state until the drive has reached the set value EF1. 0.1...1000.0 Hz or 1...60,000 RPM (Note parameter DIM!) Default value 1 (RPM) 7.1.6 MF1 Multiplication Factor (multiplier) By means of the parametres MF1 and DF1 the transmission ratio or the gear reduction ratio is calculated. They enable a conversion of the power take-off side to the rotational speed level of the drive. 1...10,000 (only whole numbers) Default value 1 Rotational speed power take-off x (MF1 DF1) = rotational speed drive Example transmission by means of V-belt: 1: Power take-off 2: Drive 1800 RPM 1500 RPM DF1 = 1800 MF1 = 1500 Example gear reduction: 1: Power take-off 2: Drive 800 RPM 1000 RPM DF1 = 800 MF1 = 1000 7.1.7 DF1 Division Factor (divisor) see MF1 1...10,000 (only whole numbers) Default value 1 18

7.1.8 DIM Dimension (display format) Indication in Hz or RPM (revolutions per minute). When a new unit is selected the monitor converts all existing values into the new unit! 0 = RPM 1 = Hz Default value 0 = RPM 7.1.9 VER Software version UK The installed software version is displayed (5-digit number with abbreviation VCO). 19

7.2 Application parameters 7.2.1 SPx Switch Point (outputs 1/2) Value at which the output changes its switching status. SP1 = switch point output 1 (slip/synchronous monitoring) SP2 = switch point output 2 (monitoring of the rotational speed of the drive) The outputs switch independent of each other. SP1: 0.1...99.9% (slip) SP2: 1...1000.0 Hz or 1...60,000 RPM (Note parameter DIM!) Default settings SP1 = 5 [%] SP2 = 500 [RPM] 7.2.2 HYx Hysteresis (hysteresis for switching outputs 1/ 2) The hysteresis value determines the distance of the reset point to the switch point SPx and prevents a possible chattering of the corresponding switching output. In connection with switching functions 5 and 6 (FOx) an acceptable range or an error range can be defined for output 2. (Not useful for output 1.) The window range in which the hysteresis is effective in both directions is set by means of a "ficticious" switch point SP. SP = (SP max + SP min ) 2 HY = (SP - SP min ) SP) x 100 [%] f SP max SP SP min FOx = 5/6 HY HY t 0.0...1000.0 % of the value for SPx Default settings HY1 = 10.0 HY2 = 5.0 20

7.2.3 STx Start-Up Delay Time (for outputs 1/2) Enables the suppression of error messages when a plant is started. When the device is switched on or when the 24 V signal is removed from the reset input, the respective output for the time set here is in the "good" state (= no fault). 0.0...1000.0 s Default settings 0.0 (no start-up delay) 7.2.4 DTx Delay Time (for outputs 1/2) UK Enables a delayed switching of the outputs 1/2. The respective output switches only if the current value is above or below the switch point for more than the time set here. 0.0...1000.0 s Default settings 0.0 (no delay time) 7.2.5 FTx Fleeting Time (for outputs 1/2) If an event occurs, the output changes its state during the set time and then switches back to the initial state. 0.0...1000.0 s Default settings 0.0 (fleeting time not active) 21

8 Programming WARNING If programming takes place during operation, dangerous contact voltage may occur. Therefore ensure that programming is done by a qualified electrician. Parameter changes during operation, especially changes to the switching function and the switch points can lead to malfunction in the plant. Therefore disconnect it during the change and then check the function. Programming consists of 6 steps: 1. Change from the RUN mode to the parameter range 1 or 2 [Enter/ ] 2. Selection of the requested parameter (FOx, SOx, NCx, etc.) [ ] / [ ] 3. Change to the PRG mode [Enter/ ] 4. Setting or changing the parameter value [ ] / [ ] 5. Acknowledgement of the set parameter value [Enter/ ] > 3 s 6. Return to the RUN mode [Enter/ ] > 3 s 8.1 Programming example DT1 (Delay Time, output 1) Operation Change from the RUN mode to the parameter range (here 1) Briefly press [Enter/ ] once. > > The 1st parameter range is displayed. Selection of the requested parameter (here DT1) Press the [ ] button until the parameter DT1 is displayed with the currently set value (here default value 0.0). Change to the PRG mode Briefly press [Enter/ ] once. > > The unit is in the programming mode. > > PRG indicator visible, parameter abbreviation flashes. CH1 CH1 CH1 Display RUN 1 RUN 0.0 DT1 RUN PRG 0.0 DT1 22

Setting or changing the parameter value Press [ ] / [ ] until the requested parameter value is displayed ( 8.2.3 Numerical entries). CH1 RUN PRG 15.0 DT1 Acknowledgement of the set parameter value Press [Enter/ ] until the parameter abbreviation no longer flashes and the indicator PRG has disappeared. > > The new parameter value is indicated and effective. CH1 RUN 15.0 DT1 Return to the RUN mode Press [Enter/ ] for about 3 s or wait for the time-out function (approx. 15 s). > > The unit is again in the RUN mode, the current value is indicated. CH1 RUN 1665 RPM UK 8.2 Notes on programming 8.2.1 RUN mode During programming the unit internally remains in the RUN mode (RUN indicator visible). This means that until a new value is acknowledged with [Enter/ ], the unit carries out its monitoring function on the basis of the previously set parameters and switches the relay and transistor outputs accordingly. The monitoring function of the monitor is deactivated by continuously pressing [Enter/ ] in the RUN mode. The deactivation is effective as long as the button is pressed. 8.2.2 Time Out Function If during programming no pushbutton is pressed for approx. 15 s, this is seen as a cancellation. Parameter changes which are not acknowledged with [Enter/ ] are rejected. The previously set parameter value is restored and remains effective for the monitoring functions. 8.2.3 Numerical entries Press [ ] or [ ] and hold it. The smallest decade becomes active and is counted up or down depending on the selected pushbutton (e.g. 1, 2, 3,...0). Then comes the next decade, etc. 23

As soon as the pushbutton is released, the active decade flashes. It is set by pressing [ ] or [ ] several times. The preceding decade then flashes and can be set. 8.2.4 Factory Reset The factory default values can be restored by pressing [ ] and [ ] simultaneously during power on. All previously entered parameter values are lost. 8.2.5 KEY function (locking) The unit can be locked to prevent incorrect entries. After locking, only the actual value indication can be switched with the [ ] and [ ] buttons. Parameter range and PRG mode can no longer be selected. Locking Press [ ] and [ ] simultaneously and hold them pressed. > > The KEY indicator flashes. Release the pushbuttons when the KEY indicator is continuously indicated. Unlocking Press [ ] and [ ] simultaneously and hold them pressed. > > The KEY indicator flashes. Release the pushbuttons when the KEY indicator is no longer indicated. 9 Test mode In the test mode the switching behaviour of the monitor can be checked, set and stored without any connected pulse pick-up. The monitor runs through a freely definable frequency range and switches the outputs according to the selected switching function and switch points. 9.1 Activate the test mode Apply the operating voltage and press [Enter/ ] simultaneously. > > The display indicates the parameter range 11 and "TST". > > In addition to the system and application parameters, the parameters for the test frequency are available. 9.2 Terminate the test mode Switch off the unit. 24

9.3 Test parameters Test parameters Display mode System/application parameters 1 Input 1 [RPM/Hz] TS1 TP1 SW1 SW2 TS1 TS2 2 Input 2 [RPM/Hz] TS2 TP2 4 UK TP1 TP2 3 IN1 IN2 [%] 1: Test frequency input 1 (slave) 2: Test frequency input 2 (master) 3: Slip 4: Back to the test parameters SWx Sweep on input 1/2 Change of speed of the test frequency 1...5 (1 = fast, 5 = slow) Default settings 1 TSx Test Start on input 1/2 Initial value of the test frequency 1...60,000 RPM or 0.1...1000.0 Hz Default settings TS1 = 500 RPM TS2 = 1000 RPM TPx Test Stop on input 1/2 Final value of the test frequency 1...60,000 RPM or 0.1...1000.0 Hz Default settings TP1 = 1500 RPM TP2 = 1000 RPM 25

10 Scale drawing 45 124,7 1 2 3 4 5 6 7 8 9 10 11 12 78 35,5 13 14 15 16 17 18 19 20 21 22 23 24 11 Technical data 11.1 Overview Art. no. DS2503 DS2603 Monitor type FS-1 FS-1N Supply voltage Frequency range see type label Power consumption Sensor types PNP/NPN: NAMUR NAMUR (to EN 50227) Sensor supply 24 V DC 8.2 V DC Input frequency 5 khz 5 khz Relay outputs 2 changeover contacts; potential free Switching current 6 A 6 A Switching voltage 250 V AC; B300, R300 Transistor outputs PNP switched; externally supplied Switching current 15 ma; short-circuit proof Switching voltage 24 V DC (± 20%) Protection housing / terminals IP 50 / IP 20 Ambient temperature -40...60 C -40...60 C Storage temperature -40...85 C -40...85 C 26

Art. no. DS2503 DS2603 Max. relative air humidity Maximum operating altitude Connection culus test conditions 80 % (31 C) linearly decreasing to 50 % (40 C) 2000 m above sea level 21 dual-chamber terminals; 2 x 2.5 mm² (AWG 14) housing dimensions for temperature rise test: 200 x 200 x 150 mm Data sheets can be found at: www.ifm.com Data sheet search article number. UK 11.2 Approvals/standards EC declarations of conformity, approvals etc. can be downloaded at: www.ifm.com Data sheet search Article number More information 12 Maintenance, repair, disposal The device is maintenance-free. Do not open the housing as the device does not contain any components which can be repaired by the user. The device must only be repaired by the manufacturer. Dispose of the device in accordance with the national environmental regulations. 27