Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

Similar documents
Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

Adapter Plates for continuous Part-Turn Actuators (Contrac)

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

ControlMaster CM15, CM30 and CM50 Universal process indicator and controllers Customizing the operator page displays

ABB MEASUREMENT & ANALYTICS DATA SHEET. DAT200 Asset Vision Basic and DTM Device Typ Manager

Electromagnetic Flowmeter FXT4000 (COPA-XT) HART-Protocol

AW Flow Meters HART Summary for RT-Ex15

ControlMaster CMF160 Universal process indicator, fieldmount

ControlMaster CMF160 Universal process indicator, fieldmount

ControlMaster controllers and indicators ConfigPilot

ScreenMaster series Paperless recorders

SM2000 Videographic recorder Spare parts and upgrade kits

TEPI11 P/I signal converter

ControlMaster PC Configuration

ControlMaster CM10, CM30, CM50 and CM15 Universal process controllers and indicator Spare parts

SM1000 Videographic recorder Spare parts and upgrade kits

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller

C160 Wall-/Pipe Mounted Universal Process Indicator

Digital Indicator DS 48/24 E

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

Introduction. Additional Information

FICHA TÉCNICA DE PRODUTO

LME620-AI/-AN (Contrac) Electrical Linear Actuator

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

Crane-Boy / Crane-BoyP Load limitation electronics

SIL-Safety Instructions SM/261/SIL-EN Rev. 05. Models 261GS/GC/GG/GJ/GM/GN/GR Models 261AS/AC/AG/AJ/AM/AN/AR Pressure Transmitter

CoriolisMaster mass flowmeter Automation solution for mixing applications

INDI BOY DSP Load limitation electronics

FICHA TÉCNICA DE PRODUTO

Indicomp 4 Bargraph Indicator

Mettler-Toledo Smart Communications Protocol Revison 1.0: June 9, 2004 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

Transmitter Cond 7100 e /2 (X)H

HART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers

Oldham OLCT 200 Revision 1

HART Protocol User Manual Rev. 1.0 December, 2014

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

INFORMATION. SM Series Videographic Recorders PC Emulator Quick Start Guide. 1 Emulation Tips. Manual IM/SM500F, IM/SM1000, IM/SM2000, IM/SM3000

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

INFORMATION. SR100A Memory Card Driver Option. 1 Availability

LineMaster 100 Continuous-line Recorder

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

SwirlMaster The new generation of swirl flowmeters

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

/8 DIN Motorized Valve Controller

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

User Guide SS4-A HART

ABB i-bus KNX BCI/S Boiler/Chiller Interface

Device Type Manager for Contrac. Graphical User Interface for digital Communication with Contrac Actuators SW Release Manual EN Rev.

2600T Series Pressure Transmitters How to replace Profibus PA pressure transmitters with the 266 PA

Pressure-Transmitter 2600T Models 261Gx, 261Ax

DELTA CONTROLS CORPORATION

HART 7.x Field Device Specification for Honeywell SLG 700 SmartLine Level Transmitter 34-SL Rev 6.0 December 2017

DELTA CONTROLS CORPORATION

ABB i-bus KNX HCC/S Heating/cooling circuit controller

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

FICHA TÉCNICA DE PRODUTO

Write Primary Variable Range Values Data written using command 35 will update the 4mA and 20mA settings in the menu.

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

VeriMaster. Software tools. Measurement made easy. Overview

/8 DIN Universal Process Indicator

Bus Connection Unit 560BCU04

HART 7.x Field Device Specification for STT700 SmartLine Temperature Transmitters Document Number: 34-TT Revision: 1.0 Release: June 2017

Model DHH805 Handheld communicator. HART fieldbus tools Handheld configuration devices

Model Ultima OPIR-5. Infrared Open Path Gas Detector HART Field Device Specification. Instruction Manual

FICHA TÉCNICA DE PRODUTO

How to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

DTM - HART SERIES 2000 and 2000-SAN

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

MagMaster Electromagnetic flowmeter. MagMaster to WaterMaster electronics upgrade. Introduction

Accessories for pluggable interface relays CR-U Pluggable function modules

Wall-/Pipe Mounted Universal Process Indicator

HART. Actuator Control. Redefining Flow Control

The Omega product you have just received is of the highest quality available, offering superior performance, reliability and value to the user.

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

DTM Bundle & DAT200 Asset Vision Basic for intelligent field devices

FICHA TÉCNICA DE PRODUTO

ABB MEASUREMENT & ANALYTICS DATA SHEET. Wellhead control application Flow computers & remote controllers

PrimaX IR. HART Specification

CEM-DAS Digital interface Data acquisition and handling system for continuous emission monitoring Software version 1.2.4

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) Process Device Manager (PDM) Device Type Manager(DTM) M10

Universal Process Controller

USER INSTRUCTIONS. MX/QX HART Field Unit. Installation Operation Maintenance. Experience In Motion FCD LMENIM /16

ABB MEASUREMENT & ANALYTICS DATA SHEET. Testomat AW101 Water hardness monitor

HART 7.x Field Device Specification for Honeywell ST 800 Smart Pressure Transmitters Document Number: 34-ST Revision: 1.

Advanced Test Equipment Rentals ATEC (2832)

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. RSD50 (Contrac) Electrical linear actuator

Accessories for pluggable interface relays CR-P Sockets

Device Management Protocols Protocoles de gestion des appareils Gerätezugangsprotokolle. The HART Protocol

Project implementation services Totalflow products & services

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. RSDE10 / RSDE20 (Contrac) Electrical linear actuator

Device Type Manager DTM for TF12, TF212

Transcription:

ABB MEASUREMENT & ANALYTICS INTERFACE DESCRIPTION TZIDC Digital Positioner HART Protocol 7.0 Valid for software levels from 05.00 Introduction The TZIDC represents the digital, intelligent positioner for communication via HART within the positioner family. For more information Additional documentation on PositionMaster TZIDC is available to download free of charge at www.abb.com/positioners. Alternatively simply scan this code:

2 TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A Table of contents 1 HART commands overview... 3 Universal commands... 3 Command 0 Read Transmitter Unique Identifier... 3 Command 1 Read Primary Variable... 3 Command 2 Read Current and Percent of Range... 4 Command 3 Read all dynamic Variables and Current... 4 Command 6 Write Polling Address... 4 Command 11 Read Unique Identifier Associated With Tag... 5 Command 12 Read Message... 5 Command 13 Read Tag, Descriptor, Date... 5 Command 14 Read Primary Variable Sensor Information... 6 Command 15 Read Primary Variable Output Information... 6 Command 16 Read Final Assembly Number... 6 Command 17 Write Message... 7 Command 18 Write Tag, Descriptor, Date... 7 Command 19 Write Final Assembly Number... 7 Command 20 Write Final Assembly Number... 7 Command 22 Write Final Assembly Number... 7 Common Practice Commands... 8 Command 33 Read Transmitter Variables... 8 Command 38 Reset Configuration Changed Flag... 8 Command 48 Read Additional Transmitter Status... 9

Change from one to two columns Change from two to one column TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A 3 1 HART commands overview This overview lists all HART commands which can be used by customers. It includes universal and common practice commands, as well as special ones such as slot commands, among others. Universal commands Command 0 Read Transmitter Unique Identifier Command 0 Mnemonic Offset Size Datatype Request Data Bytes None - - - Response Data Bytes Device Type Code for Expansion = 254 #0 1 USIGN8 Manufacturer Identification Code = 22 #1 1 USIGN8 Manufacturer Device Type = 65 #2 1 USIGN8 Number of Request Preambles = 5 #3 1 USIGN8 Revision Level of Universal Command = 7 #4 1 USIGN8 Device Revision Level = X #5 1 USIGN8 Software Revision Level = XX #6 1 USIGN8 Hardware Revision Level = XX #7 1 USIGN8 Flags, none defined at this time = 0 #8 1 USIGN8 Device Identification Number #9 1 USIGN8 Device Identification Number #10 1 USIGN8 Device Identification Number #11 1 USIGN8 Number of Response preamble = 5 #12 1 USIGN8 Maximum number of device variables #13 1 USIGN8 Configuration change counter #14 to 15 2 USIGN16 Extended field device status #16 1 USIGN8 Manufacturer identification code #17 to 18 2 USIGN16 Private label distributor code #19 to 20 2 USIGN16 Device profile #21 1 USIGN8 Command 1 Read Primary Variable Command 1 Mnemonic Offset Size Datatype Request Data Bytes None - - - Response Data Bytes Primary Variable Unit Code #0 1 USIGN8 Primary Variable #1 to 4 4 FLOAT

4 TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A... 1 HART commands overview... Universal commands Command 2 Read Current and Percent of Range Command 2 Mnemonic Offset Size Datatype Request Data Bytes None - - - Response Data Bytes Analog Output Current ma #0 to 3 4 FLOAT Analog Output Percent #4 to 7 4 FLOAT Command 3 Read all dynamic Variables and Current Command 3 Mnemonic Offset Size Datatype Request Data Bytes None - - - Response Data Bytes Analog Output Current #0 to 3 4 FLOAT Primary Variable Unit Code #4 5 USIGN8 Primary Variable [ Position ] #5 to 8 FLOAT Secondary Variable Unit Code #9 5 USIGN8 Secondary Variable [Setpoint] #10 to 13 FLOAT Tertiary Variable Unit Code #14 5 USIGN8 Tertiary Variable [Electr. Temperature] #15 to 18 FLOAT 4th Variable Unit Code #19 5 USIGN8 4th Variable [Control Deviation] #20 to 23 USIGN8 Command 6 Write Polling Address Command 6 Mnemonic Offset Size Datatype Request Data Bytes Polling Address of Device #0 1 USIGN8 Response Data Bytes Polling Address of Device #0 1 USIGN8 2 Invalid Selection

TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A 5 Command 11 Read Unique Identifier Associated With Tag Command 11 Mnemonic Offset Size Datatype Request Data Bytes Tag #0 6 PACKED ASCII Response Data Bytes Device Type Code for Expansion = 254 #0 1 USIGN8 Manufacturer Identification Code = 22 #1 1 USIGN8 Manufacturer Device Type = 65 #2 1 USIGN8 Number of Request Preambles = 8 #3 1 USIGN8 Revision Level of Universal Command = 7 #4 1 USIGN8 Revision Level of Transmitter Document = X #5 1 USIGN8 Software Revision Level = XX #6 1 USIGN8 Hardware Revision Level = XX #7 1 USIGN8 Flags, none defined at this time = 0 #8 1 USIGN8 Device Identification Number #9 1 USIGN8 Device Identification Number #10 1 USIGN8 Device Identification Number #11 1 USIGN8 Command 12 Read Message Command 12 Mnemonic Offset Size Datatype Request Data Bytes None - - - Response Data Bytes HART Message #0 to 23 24 PACKED ASCII Command 13 Read Tag, Descriptor, Date Command 13 Mnemonic Offset Size Datatype Request Data Bytes None Response Data Bytes HART Tag #0 to 5 6 PACKED ASCII HART Descriptor #6 to 17 12 PACKED ASCII HART Day #18 1 USIGN8 HART Month #19 1 USIGN8 HART Year #20 1 USIGN8

6 TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A... 1 HART commands overview... Universal commands Command 14 Read Primary Variable Sensor Information Command 14 Mnemonic Offset Size Datatype Request Data Bytes None Response Data Bytes Sensor Serial Number = 0 #0 to 2 3 USIGN16 Sensor Limits / Min Span Units = Unit #1 1 USIGN8 Upper Sensor Limit #3 to 7 5 FLOAT Lower Sensor Limit #8 to 11 4 FLOAT Minimum Span #12 to 15 4 FLOAT Command 15 Read Primary Variable Output Information Command 15 Mnemonic Offset Size Datatype Request Data Bytes None Response Data Bytes Alarm Select Code Low = 0, High = 1 #0 1 USIGN8 Primary Variable Transfer Function = HART Pv Transfer Function = 0 #1 1 USIGN8 Primary Variable Range Values Units #2 1 USIGN8 Primary Variable Upper Range Value #3 to 6 4 FLOAT Primary Variable Lower Range Value HART Pv Lower Range Value = 0 #7 to 10 4 FLOAT Primary Variable Damping Value = Damping #11 to 14 4 FLOAT Write Protect Code = HART Write Protect = 251 #15 1 USIGN8 Private Label Distributor Code = HART Private Label Distributor = 26 #16 1 USIGN8 Command 16 Read Final Assembly Number Command 16 Mnemonic Offset Size Datatype Request Data Bytes None Response Data Bytes HART Final Assembly Number #0 to 2 3 STRINGV

TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A 7 Command 17 Write Message Command 17 Mnemonic Offset Size Datatype Request Data Bytes HART Message #0 to 23 24 PC ASCII Response Data Bytes HART Message #0 to 23 24 PC ASCII Command 18 Write Tag, Descriptor, Date Command 18 Mnemonic Offset Size Datatype Request Data Bytes Tag = HART Tag #0 to 5 6 PC ASCII Descriptor = HART Descriptor #6 to 17 12 PC ASCII Day = HART Date Day #18 1 USIGN8 Month = HART Date Month #19 1 USIGN8 Year = HART Date Year #20 1 USIGN8 Response Data Bytes Tag = HART Tag #8 to 5 6 PC ASCII Descriptor = HART Descriptor #6 to 17 12 PC ASCII Day = HART Date Day #18 1 USIGN8 Month = HART Date Month #19 1 USIGN8 Year = HART Date Year #20 1 USIGN8 Command 19 Write Final Assembly Number Command 19 Mnemonic Offset Size Datatype Request Data Bytes Final Assembly Number #0 to 2 3 STRINGV Response Data Bytes Final Assembly Number #0 to 2 3 STRINGV Command 20 Write Final Assembly Number Command 20 Mnemonic Offset Size Datatype Request Data Bytes None #0 3 STRINGV Response Data Bytes Long tag #0 to 31 3 STRINGV Command 22 Write Final Assembly Number Command 22 Mnemonic Offset Size Datatype Request Data Bytes Long tag #0 to 31 3 STRINGV Response Data Bytes Long tag #0 to 31 3 STRINGV

8 TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A... 1 HART commands overview Common Practice Commands Command 33 Read Transmitter Variables With this command, it is possible to initiate a request using one, two, three or four of the four available slot numbers. The request can be initiated using the same slot number four times or using different slot numbers. If a requested device variable is not supported in the field device, then the corresponding value must be set to 0x7F, 0xA0, 0x00, 0x00 and the unit code must be set to 250 (= not set). Command 33 Slot Mnemonic Offset Size Datatype Request Data Bytes 0 Transmitter Variable - 1-0, 1 Transmitter Variable - 2 0, 1, 2 Transmitter Variable - 3 0, 1, 2, 3 Transmitter Variable - 4 Response Data Bytes 0 Slot Number = 0 1 USIGN8 Unit Code = Percentage 1 USIGN8 Slot #0 Variable = Position 4 FLOAT 1 Slot Number = 1 1 USIGN8 Unit Code = ma 1 USIGN8 Slot #0 Variable = Current IN 4 FLOAT 2 Slot Number = 2 1 USIGN8 Unit Code 1 USIGN8 Slot #0 Variable = Electr. Temperature 4 FLOAT 3 Slot Number = 3 1 USIGN8 Unit Code = Percentage 4 USIGN8 Slot #0 Variable = Control Deviation 1 FLOAT 4 Slot Number = 4 1 USIGN8 Unit Code = ma 1 USIGN8 Slot #0 Variable = Analog Out (With option ) 4 FLOAT 5 Slot Number = 5 1 USIGN8 Unit Code = Percent 1 USIGN8 Slot #0 Variable = Analog Out (With option ) 4 FLOAT 244 Slot Number = 244 1 USIGN8 Unit Code = ma 1 USIGN8 Slot #0 Variable = Current in 4 FLOAT Command 38 Reset Configuration Changed Flag Command 38 Mnemonic Offset Size Datatype Request Data Bytes None VOID Response Data Bytes None VOID

TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A 9 Command 48 Read Additional Transmitter Status Command 48 Slot Mnemonic Offset Size Datatype Request Data Bytes None - Byte 5 0x01 Leakage detected #5 1 USIGN8 0x02 0x04 0x08 0x10 0x20 0x40 0x80 Setpoint out of range Position out of range Not following current Positioning time out Movement counter limit exceeded Travel counter limit exceeded Device error Byte 6 Reserved 0 #6 1 USIGN8 Byte 7 Reserved 1 #7 1 USIGN8 Byte 8 Reserved 2 #8 1 USIGN8 Byte 9 Reserved 3 #9 1 USIGN8 Byte 10 reserved 4 #10 1 USIGN8 Byte 11 reserved 5 #11 1 USIGN8 Byte 12 reserved 6 #12 1 USIGN8 Byte 13 reserved 7 #13 1 USIGN8 Byte 14 reserved 7 #14 1 USIGN8 Byte 15 reserved 7 #15 1 USIGN8 Byte 16 reserved 7 #16 1 USIGN8 Byte 17 reserved 7 #17 1 USIGN8 Byte 18 reserved 7 #18 1 USIGN8 Byte 19 reserved 7 #19 1 USIGN8 Byte 20 reserved 7 #20 1 USIGN8 Byte 21 reserved 7 #21 1 USIGN8 Byte 22 reserved 7 #22 1 USIGN8 Byte 23 reserved 7 #23 1 USIGN8 Byte 24 0x01 Switch point 1 exceeded #24 1 USIGN8 0x02 0x04 0x08 0x10 0x20 0x40 0x80 Switch point 2 exceeded Set Point out of range Not following current Configuration failure Digital IN is active Simulation active Fail safe active

10 TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A Notes

Notes TZIDC DIGITAL POSITIONER COM/TZIDC/HART-EN REV. A 11

ABB Limited Measurement & Analytics Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Tel: +44 (0)870 600 6122 Fax: +44 (0)1480 213 339 Mail: enquiries.mp.uk@gb.abb.com ABB Automation Products GmbH Measurement & Analytics Schillerstr. 72 32425 Minden Germany Tel: +49 571 830-0 Fax: +49 571 830-1806 ABB Inc. Measurement & Analytics 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/positioners We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB All rights reserved 3KXE341201R4001 COM/TZIDC/HART-EN Rev. A 03.2018