Arista 7050X, 7050X2, 7250X and 7300 Series Performance Validation

Similar documents
Switching Architectures for Cloud Network Designs

Investment Protection with the Arista 7500 Series

Creating High Performance Best-In-Breed Scale- Out Network Attached Storage Solutions

Arista 7500 Series Interface Flexibility

Big Data Big Data Becoming a Common Problem

Arista FlexRoute TM Engine

The benefits Arista s LANZ functionality will provide to network administrators: Real time visibility of congestion hotspots at the microbursts level

Arista Networks and F5 Solution Integration

ARISTA WHITE PAPER Arista FlexRouteTM Engine

Arista Cognitive WiFi

Architecting Low Latency Cloud Networks

Leveraging EOS and sflow for Advanced Network Visibility

CloudVision Macro-Segmentation Service

TAP Aggregation with DANZ

An Overview of Arista Ethernet Capture Timestamps

Rapid Automated Indication of Link-Loss

Five ways to optimise exchange connectivity latency

Networking in the Hadoop Cluster

Why Big Data Needs Big Buffer Switches

NEP UK selects Arista as foundation for SMPTE ST 2110 modular OB trucks to deliver UHD content from world s largest events

The zettabyte era is here. Is your datacenter ready? Move to 25GbE/50GbE with confidence

Latency Analyzer (LANZ)

The Impact of Virtualization on Cloud Networking

Arista 7060X & 7260X Performance

Introduction: PURPOSE BUILT HARDWARE. ARISTA WHITE PAPER HPC Deployment Scenarios

Virtual Extensible LAN (VXLAN) Overview

CHANGING DYNAMICS OF IP PEERING Arista Solution Guide

Traffic Visualization with Arista sflow and Splunk

10Gb Ethernet: The Foundation for Low-Latency, Real-Time Financial Services Applications and Other, Latency-Sensitive Applications

Arista 7160 Series Switch Architecture

Cloudifying Datacenter Monitoring with DANZ

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility

Arista 7050X3 Series Switch Architecture

Arista AgilePorts INTRODUCTION

Arista Telemetry. White Paper. arista.com

Cloud Interconnect: DWDM Integrated Solution For Secure Long Haul Transmission

Bioscience. Solution Brief. arista.com

Powering Next Generation Video Delivery

Four key trends in the networked use of FPGAs

Arista 7170 Multi-function Programmable Networking

Arista 7050X & 7050X2 Switch Architecture ( A day in the life of a packet )

The Arista Universal transceiver is the first of its kind 40G transceiver that aims at addressing several challenges faced by today s data centers.

Arista 7500E DWDM Solution and Use Cases

Simplifying Network Operations through Data Center Automation

Cisco Nexus 6004 Switch Performance Validation

Deploying IP Storage Infrastructures

Arista 7060X, 7060X2, 7260X and 7260X3 series: Q&A

World Class, High Performance Cloud Scale Storage Solutions Arista and EMC ScaleIO

Solving the Virtualization Conundrum

Arista Cognitive Campus Network

Exploring the Arista 7010T - An Overview

Routing Architecture Transformations

Arista EOS Precision Data Analysis with DANZ

Huawei Technologies requested Miercom evaluate the

Broadcast Transition from SDI to Ethernet

Spanning Tree Protocol Interoperability With Cisco PVST+/PVRST+/MSTP

Migration from Silo Security to Secure Holistic Cloud Networking

Software Driven Cloud Networking

Table 1: Arista 7250X and 7300 Series overview. Maximum System Density 10GbE ports. Maximum System Density 40GbE ports

Arista 7300X and 7250X Series: Q&A

High Speed Networking for Digital Media Creation, Post Production, and Centralized Content Management

Arista 7050X Switch Architecture ( A day in the life of a packet )

Arista CloudVision : Cloud Automation for Everyone

Exploring the 7150S Family

Cisco Nexus 9508 Switch Power and Performance

Deploying Data Center Switching Solutions

Mellanox Virtual Modular Switch

Arista 7050X Series: Q&A

Cisco Nexus 3548 Switch Performance Validation December 2012

100G MACsec Solution: 7500R platform

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture

Hyper-Converged Rack-Level Solutions

Arista 7050X Series: Q&A

ARISTA AND LEVITON Technology in the Data Center

White Paper. OCP Enabled Switching. SDN Solutions Guide

Arista 7160 series: Q&A

Arista 7320X: Q&A. Product Overview. 7320X: Q&A Document What are the 7320X series?

Highest Levels of Scalability Simplified Network Manageability Maximum System Productivity

Arista 7170 series: Q&A

High performance Ethernet networking MEW24. High performance Ethernet networking

Lab Test Report DR100401D. Cisco Nexus 5010 and Arista 7124S

Arista 7280R Switch Architecture ( A day in the life of a packet )

The Arista Advantage Cloud Networking Trends

ARISTA WHITE PAPER Arista 7500R Universal Spine Platform Architecture ( A day in the life of a packet )

Introduction. Executive Summary. Test Highlights

ARISTA: Improving Application Performance While Reducing Complexity

Arista 7010 Series: Q&A

LabTest Report. Cisco Nexus 3064

TOLLY. No November 2005 Nortel Ethernet Routing Switch 5510, 5520, 5530 Layer 2 Performance, Resiliency and Ease of Use

Arista Networks range of 1Gb, 10Gb, 40Gb and 100GbE Ethernet switches are the foundation for many of the worlds largest data centers.

Accelerate Your Digital Transformation

Cisco engaged Miercom to verify the performance and advanced

Dell Networking S6000

ARISTA WHITE PAPER Arista 7500 Switch Architecture ( A day in the life of a packet )

QLogic 10GbE High-Performance Adapters for Dell PowerEdge Servers

Arista 7020R Series: Q&A

reinventing data center switching

Lab Testing Summary Report

SWITCH OVERVIEW. ARISTA WHITE PAPER Arista 7500 Switch Architecture ( A day in the life of a packet )

Arista 7500R Switch Architecture ( A day in the life of a packet )

Transcription:

Arista 7050X, 7050X2, 7250X and 7300 Series Performance Validation Arista Networks was founded to deliver software driven cloud networking solutions for large datacenter and highperformance computing environments. The Arista 7050X, 7050X2, 7250X, and 7300X series of leaf, spine and spline switches are purpose built to deliver ultra high density 10 Gigabit Ethernet and 40GbE switching in compact form factors. To validate performance of modern high density switches requires having dedicated access to highly specialized and costly testing equipment, access to the devices being tested, knowledge of configuring the test suites and the expertize to obtain accurate and reliable testing results. While many customers will perform product testing, this whitepaper provides a series of detailed performance testing results achieved with the Arista 7050X, 7050X2, 7250X, and 7300 Series that reduces the need for customers and partners to dedicate their own testing time to validating the performance of these Arista Networks switches.

Introduction Increased adoption of 10 Gigabit Ethernet servers coupled with applications requiring higher bandwidth is accelerating the need for dense 10 and 40 Gigabit Ethernet switching. The Arista 7050X, 7050X2 and 7250X Series support a flexible combination of 10G and 40G in highly compact form factors which allows customers to design large leaf and spine networks to accommodate both east- west traffic patterns and a requirement for low latency and power efficiency. The Arista 7300 series are a purpose built range of modular chassis and a key component of the Arista datacenter product portfolio. When coupled with the 7300X series linecards the 7300 series add a new dimension of design flexibility and scalability in traditional MoR/EoR, Leaf and Spine and Spline deployments. It is the goal of this report to identify and evaluate analytical performance data regarding the 7050X, 7050X2, 7250X and 7300 series of switches from Arista Networks. Performance data will be evaluated over the two primary metrics critical to data center environments, latency and throughput. It is not the goal of this report to highlight the best of all possible worlds results, but rather to act as a guide for Arista customers as to what levels of performance can be expected in a real world deployment. Based on this requirement the tests do not adhere strictly to the RFC standard tests. However they do integrate the spirit of the RFCs with regards to avoiding specmanship and providing accurate and repeatable results. Platform Choices All three of the 7050X, 7050X2, 7250X and 7300X Series are designed with a common architecture specifically to meet the challenges of dense 10 Gigabit and 40 Gigabit Ethernet switching, offering low latency of 550ns in cut- through mode and a shared buffer architecture that is allocated dynamically to ports that are congested. With typical power consumption of less than 5 watts per 40GbE port (or 1.2W per 10GbE equivalent) the 7050X, 7050X2, 7250X and 7300 Series provide industry leading power efficiency. Built on top of the same industry defining EOS image that runs on the entire Arista product portfolio, the 7050X, 7050X2, 7250X and 7300X Series deliver advanced features for big data, cloud, virtualized and traditional designs in a vast choice of form factors. Figure 1: Arista 7050X, 7250X and 7300 Series portfolio of datacenter switches

With typical power consumption of less than 5 watts per 40GbE port (or 1.2W per 10GbE equivalent) the 7050X, 7050X2, 7250X and 7300 Series provide industry leading power efficiency. Built on top of the same industry defining EOS image that runs on the entire Arista product portfolio, the 7050X, 7050X2, 7250X and 7300X Series deliver advanced features for big data, cloud, virtualized and traditional designs in a vast choice of form factors. Table 1: Arista Portfolio Overview 7050QX / 7050QX2 7050TX / 7050TX2 7050SX / 7050SX2 Characteristic 32 32S 48 64 72 72Q 96 128 64 72 72Q 96 128 64 7304 7308 7316 Switch Height (RU) 1RU 1RU 1RU 1RU 1RU 1RU 1RU 2RU 1RU 1RU 1RU 1RU 2RU 2RU 8RU 12RU 21RU BaseT Ports -- -- 32 48 48 48 48 48 -- -- -- -- -- -- -- -- -- SFP+ Ports -- 4 -- -- -- -- -- -- 48 48 48 48 96 -- 192 384 768 QSFP+ Ports 32 32 4 4 -- 6 -- 8 4 -- 6 -- 8 64 128 256 512 MXP Ports -- -- -- -- 2 -- 4 -- -- 2 -- 4 -- -- -- -- -- 7250 QX 7300 Maximum Density 10GbE Maximum Density 40GbE 96 96 48 64 72 72 96 96 64 72 72 96 96 256 512 1024 2048 32 32 4 4 6 6 12 8 4 6 6 12 8 64 128 256 512 The Arista 7050X, 7050X2, 7250X and 7300 series switches combined with the Arista leaf-spine or SplineTM design methodologies provide flexible design solutions for network architects looking to deliver market-leading performance driven networks, which scale from several hundred hosts all the way up several hundred thousand hosts. Test Methodology To evaluate realistic performance data from the selected switching platforms a thorough set of tests were executed. The tests were designed to focus on the two key aspects of performance, latency and throughput. The design of the tests was such that any results gathered with the test plan are easily reproducible, not only in a lab environment, but a production one also. All tests used Ixia devices running IxNetwork 7.10 EA-SP1 to generate and account traffic, ensuring the results collected are both detailed and accurate. All 7050SX and 7050QX switches used in this testing are running EOS version 4.13.0, all 7050TX switches are running EOS version 4.14.1, all 7050X2 switches are running an internal EFT build based on the 4.15 train of EOS. The 7050X, 7050X2, 7250X and 7300 Series were developed to offer operational flexibility to network architects when developing large scale designs, due to that flexibility the exact details of the tests executed on each platform differ slightly, to ensure transparency the following section illustrates the exact test bed in each of the testing scenarios and highlights any per-platform differences. Latency This test is to validate realistic latency between a pair of ports when receiving traffic at line rate. The test provides an understanding of both the serialization and forwarding delays incurred by the switch when routing packets of various sizes, between interfaces of differing speeds. Test Explanation Packets are transmitted between a pair of physically remote ports, for a fixed duration at a fixed traffic rate, equal to the line rate of the slowest port in the pair. The traffic generator collects a timestamp on the transmitting port, and a second on the receiving port. The difference between these timestamps is the latency. All latency tests use first in first out (FIFO) testing, this method will account not only forwarding delay but also serialization delay. This ensures the results are taken from an end-to-end latency perspective rather than simply that

of the switch pipeline. It also enables the direct comparison between store-and-forward and cut-through tests. Figure 2: Latency - Test Bed The latency was measured for L3 routed traffic at packet sizes of 64, 128, 256, 512, 1024, 1280 1518, 2176 and 9216. In addition the test was repeated over all possible permutations of both ingress/egress interface speed and both store and forward and cut-through forwarding modes. Test Notes 7250QX-64 and 7300 Single chip latency uses ports on the same Packet Processor 7250QX-64 and 7300 Multi chip latency uses ports on different Packet Processors The 7050SX series share identical latency characteristics, therefore are merged into a single set of results for brevity. The 7050TX series share identical latency characteristics, therefore are merged into a single set of results for brevity. All DUTs are configured in 10G latency mode. Results are based on the average latency observed during a fixed duration test, not the minimum The following figures illustrate the accepted serialization delays at 10 and 40Gbps interface speeds, allowing more direct comparisons between results irrespective of the forwarding mode used in that test. Figure 3: 10Gbps & 40Gbps Serialization delays

Test Results 7050QX/7050QX2 Series Figure 4: Latency - 7050QX/7050QX2 Series - Packet Loss Data Figure 5: Latency - 7050QX/7050QX2 Series - Results all modes Figure 6: Latency - 7050QX/7050QX2-40G Cut-through Latency Range

Figure 7: Latency - 7050QX/7050QX2 - Jitter 7050SX/7050SX2 Series Figure 8: Latency - 7050SX/7050SX2 - Packet Loss Data Figure 9: Latency - 7050SX/7050SX2 - Results all modes

Figure 10: Latency - 7050SX/7050SX2-40G Cut-through Latency Range Figure 11: Latency - 7050SX/7050SX2 - Jitter 7050TX/7050TX2 Series Figure 12: Latency - 7050TX/7050TX2 - Packet Loss Data

Figure 13: Latency - 7050TX/7050TX2 - Results all modes Figure 14: Latency - 7050TX/7050TX2-10G Cut-through Latency Range Figure 15: Latency - 7050TX/7050TX2 - Jitter

7250QX Series Figure 16: Latency - 7250QX-64 - Packet Loss Data Figure 17: Latency - 7250QX-64 - Results all modes Figure 18: Latency - 7250QX-64 - MultiChip 40G Cut-through Latency Range

Figure 19: Latency - 7250QX-64 - SingleChip 40G Cut-through Latency Range Figure 20: Latency - 7250QX-64 - Jitter 7300 Series Figure 21: Latency - 7300X Series - Packet Loss Data

Figure 22: Latency - 7300X Series - Results all modes Figure 23: Latency - 7300X Series - MultiChip 40G Cut-through Latency Range Figure 24: Latency - 7300X Series - SingleChip 40G Cut-through Latency Range

Figure 25: Latency - 7300X Series - Jitter Throughput This test verifies the switch performance when line rate traffic is received on all ports simultaneously. Additionally it illustrates any performance differential between the volume of data which can be forwarded through the pipeline, and that can be received on the physical interfaces. Test Explanation The lowest and highest numbered ports on the DUT are connected to a pair of Ixia ports. Intermediate ports are looped in a snake configuration. Each Ixia generated packet must therefore pass through all intermediate interfaces before reaching the destination Ixia port ensuring that uniform line rate traffic is received on all interfaces. All platforms are benchmarked in two situations, all ports active and 75% of ports active. Each test will send packets over a set duration for multiple fixed packet sizes, confirming at which packet sizes the switch is truly line rate. Figure 26: Throughput - Test Bed Test Explanation All switches which offer a mix of 10GbE and 40GbE interfaces have two simultaneous traffic profiles. A 10G Flow is sent/ received and snaked between the SFP+ ports (Ethernet1 - Ethernet 96). A 40G Flow is sent/received and snaked between the QSFP+ ports (Ethernet 97 Ethernet 104). All 7050X tests use adjacent interface pairs for the snake. The 7250QX-64 and 7300 series use non-adjacent pairs for the snake, to ensure all packets traverse the switching fabric. All DUTs are configured in performance mode.

The 7050SX-64, 7050SX-72, 7050SX-72Q and 7050SX-96 offer identical performance, therefore are merged into a single set of results. The 7050TX-48, 7050TX-64, 7050TX-72, 7050TX-72Q and 7050TX-96 offer identical performance, therefore are merged into a single set of diagrams. 7050QX/7050QX2 Series Figure 27: Throughput - 7050QX/7050QX2 Series - 100% Active Ports Figure 28: Throughput - 7050QX/7050QX2 Series - 75% Active Ports

7050SX (-64/-72/-72Q/-96) Figure 29: Throughput - 7050SX(-64/-72/-96) - 100% Active Ports Figure 30: Throughput - 7050SX(-64/-72/-96) - 75% Active Ports

7050SX-128, 7050SX2-128 Figure 31: Throughput - 7050SX-128/7050SX2-128 - 100% Active Ports Figure 32: Throughput - 7050SX-128/7050SX2-128 - 75% Active Ports

7050TX (-48/-64/-72/-72Q/-96) Figure 33: Throughput - 7050TX (-48/-64/-72/-96) - 100% Active Ports Figure 34: Throughput - 7050TX (-48/-64/-72/-96) - 75% Active Ports

7050TX-128, 7050TX2-128 Figure 35: Throughput - 7050TX-128/7050TX2-128 - 100% Active Ports Figure 36: Throughput - 7050TX-128/7050TX2-128 - 75% Active Ports

7250QX-64 Figure 37: Throughput - 7250QX-64-100% Active Ports Figure 38: Throughput - 7250QX-64-75% Active Ports

7300X Series Figure 39: Throughput - 7300X Series- 100% Active Ports Figure 40: Throughput - 7300X Series - 75% Active Ports

Conclusion The Arista 7050X, 7050X2, 7250X and 7300X Series provide a high-performance, high-density, power efficient solution for modern datacenter environments. Combining advanced functionality with a variety of form factors to suit all possible deployments. The switches have proven to provide consistently low latency, with a very tight jitter band across all packet sizes. It has also been verified that the 7050X, 7050X2, 7250X and 7300X offer line rate forwarding and replication across all ports, in a real world deployment where the aggregate packet size is greater than 200B, or for all packet sizes when 6 out of every 8 40GbE ports are used. Santa Clara Corporate Headquarters 5453 Great America Parkway, Santa Clara, CA 95054 Phone: +1-408-547-5500 Fax: +1-408-538-8920 Email: info@ Ireland International Headquarters 3130 Atlantic Avenue Westpark Business Campus Shannon, Co. Clare Ireland Vancouver R&D Office 9200 Glenlyon Pkwy, Unit 300 Burnaby, British Columbia Canada V5J 5J8 San Francisco R&D and Sales Office 1390 Market Street, Suite 800 San Francisco, CA 94102 India R&D Office Global Tech Park, Tower A & B, 11th Floor Marathahalli Outer Ring Road Devarabeesanahalli Village, Varthur Hobli Bangalore, India 560103 Singapore APAC Administrative Office 9 Temasek Boulevard #29-01, Suntec Tower Two Singapore 038989 Nashua R&D Office 10 Tara Boulevard Nashua, NH 03062 Copyright 2017 Arista Networks, Inc. All rights reserved. CloudVision, and EOS are registered trademarks and Arista Networks is a trademark of Arista Networks, Inc. All other company names are trademarks of their respective holders. Information in this document is subject to change without notice. Certain features may not yet be available. Arista Networks, Inc. assumes no responsibility for any errors that may appear in this document. Apr 17, 2017 02-0045-02