Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Similar documents
Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.11

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ERS.21

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Electronic timer CT-ERD.12

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Electronic timer CT-AHD.22

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.21

Thermistor motor protection relay CM-MSS.11

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.31

Thermistor motor protection relay CM-MSS.41

Messaging module CP-C MM

Three-phase monitoring relay

Redundancy unit CP-A RU

Power supply CP-E 48/1.25 Primary switch mode power supply

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Power supply CP-E 24/10.0 Primary switch mode power supply

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Power supply CP-C 24/5.0

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Contact protection relay

Pluggable interface relays CR-P Pcb relays

Electronic timers CT range

Accessories for pluggable interface relays CR-P Sockets

Power supply CP-C 24/5.0

Pluggable interface relays CR-M Miniature relays

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Electronic timers CT range

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

TU531, TU532 Terminal Unit

Accessories for pluggable interface relays CR-U Pluggable function modules

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

DI572 Digital Input Module

ABB i-bus KNX HCC/S Heating/cooling circuit controller

AI561 Analog Input Module

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

TF501, TF521 Terminal Bases

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

AO523 Analog Input Module

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

DI561 Digital Input Module

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

DC561, digital input/output module,

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

DC562, digital input/output module,

MINI-PS AC/10-15DC/8

ABB i-bus KNX BCI/S Boiler/Chiller Interface

DX561 Digital Input/Output Module

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

RM4JA01F current measurement relay RM4-J - range ma V AC

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM35LM33MW liquid level control relay RM35-L V AC/DC

Output Voltage* (nom.)(adjustable)

TRIO-DIODE/12-24DC/2X10/1X20

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

Transcription:

Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges and a continuous rated control voltage that enables worldwide use regardless of the supply voltage. All electronic timers from the CT-S range are available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (Push-in terminals). 2CDC 251 034 V0011 Characteristics Rated control supply voltage 24 240 V AC/DC OFF delay timer without auxiliary voltage 7 time ranges (0.05 s 10 min) Precise adjustment by front-face operating elements Screw connection technology or Easy Connect Technology available Housing material for highest fire protection classification UL 94 V-0 Tool-free mounting on DIN rail as well as demounting 1 c/o (SPDT) contact 22.5 mm (0.89 in) width 1 LED for status indication Approvals A UL 508, CAN/CSA C22.2 No.14 C GL pending D GOST K CB scheme E CCC Marks a CE b C-Tick Order data Electronic timers Type Rated control supply voltage Connection technology Time ranges Order code CT-ARS.11P 24 240 V AC/DC Push-in terminals 0.05 s 10 min 1SVR 740 120 R3100 CT-ARS.11S 24-240 V AC/DC Screw type terminals 0.05 s 10 min 1SVR 730 120 R3100 Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SVR 430 029 R0100 MAR.01 Marker label 1SVR 366 017 R0100 COV.11 Sealable transparent cover 1SVR 730 005 R0100

Connection technology Maintenance free Easy Connect Technology with Push-in terminals Type designation CT-xxS.yyP Approved screw connection technology with double-chamber cage connection terminals Type designation CT-xxS.yyS 2CDC 253 026 F0011 2CDC 253 025 F0011 Push-in terminals Tool-free connection of rigid and flexible wires with wire end ferrule according to DIN 46228-1-A, DIN 46228-4-E Wire size: 2 x 0.5-1.5 mm², (2 x 20-16 AWG) Easy connection of flexible wires without wire end ferrule by opening the terminals No retightening necessary One operation lever for opening both connection terminals For triggering the lever and disconnecting of wires you can use the same tool (Screwdriver according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in)) Constant spring force on terminal point independent of the applied wire type, wire size or ambient conditions (e. g. vibrations or temperature changes) Opening for testing the electrical contacting Gas-tight Double-chamber cage connection terminals Terminal spaces for different wire sizes: fine strand with/without wire end ferrule: 1 x 0.5-2.5 mm² (2 x 20-14 AWG), 2 x 0.5-1.5 mm² (2 x 20-16 AWG) rigid: 1 x 0.5-4 mm² (1 x 20-12 AWG), 2 x 0.5-2.5 mm² (2 x 20-14 AWG) One screw for opening and closing of both cages Pozidrive screws for pan- or crosshead screwdrivers according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in) Both the Easy Connect Technology with Push-in terminals and screw connection technology with double-chamber cage connection terminals have the same connection geometry as well as terminal position. 2 - Electronic timer CT-ARS.11 Data sheet

Functions Operating controls 1 Rotary switch for the preselection of the time range 2 Fine adjustment of the time delay 2CDC 251 034 V0011 1 3 2 4 3 Indication of operational states U: green LED - control supply voltage 4 Marker label Application The CT S range timers are designed for use in industrial applications. They operate over an universal range of supply voltages and a large time delay range, within compact dimensions. The easy to set front face potentiometers, with direct reading scales, provide accurate time delay adjustment. Operating mode The CT ARS.11 with 1 c/o contact offers 7 time ranges, from 0.05 s to 10 min, for the adjustment of the time delay. The time delay range is rotary switch selectable. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. Function diagram OFF delay without auxiliary voltage The OFF delay function without auxiliary voltage does not require continuous control supply voltage for timing. Prior to first commissioning and after a six-month stop in operation, a formatting time of 5 minutes is necessary. Applying control supply voltage energizes the output relay immediately. Applied control supply voltage is displayed by the glowing green LED. If control supply voltage is interrupted, the OFF delay starts and the LED turns off. When timing is complete, the output relay de energizes. For correct operation of the unit, it is necessary to complete the minimum energizing time. A1-A2 15-18 15-16 green LED t = adjusted time delay t 2CDC 252 030 F0207 Electrical connection A1 15 15 16/18 1 c/o (SPDT) contact A1 15 A1 A2 Rated control supply voltage U S 24 240 V AC/DC A2 16 18 18 16 A2 2CDC 252 014 F0b06 Connection diagram Data sheet Electronic timer CT-ARS.11-3

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Supply circuit A1 A2 Rated control supply voltage U S 24 240 V AC/DC Rated control supply voltage U S tolerance 15...+10 % Rated frequency DC n/a AC 50/60 Hz Frequency range AC 47 63 Hz Typical current / power consumption 24 V DC 1 ma / - 115 V AC 2.5 ma / - 230 V AC 3.1 ma / - Formatting time (prior to 1st commissioning and after a six-month stop in operation) 5 min Minimum duty time 100 ms Timing circuit Kind of timer Single function timer OFF delay without auxiliary voltage Time ranges 0.05 s 10 min 0.05 1 s, 0.15 3 s, 0.5 10 s, 1.5 30 s, 5 100 s, 15 300 s, 0.5 10 min Recovery time < 50 ms Repeat accuracy (constant parameters) Δt <± 0.2 % Accuracy within the rated control supply voltage tolerance Δt < 0.004 %/V Accuracy within the temperature range Δt < 0.03 %/ C User interface Indication of operational states Control supply voltage U: green LED V: control supply voltage applied Output circuits Kind of output 15 16/18 Relay, 1 c/o (SPDT) contact Contact material Cd free Rated operational voltage U e 250 V Minimum switching voltage / Minimum switching current 12 V / 10 ma Maximum switching voltage / Minimum switching current see Load limit curves on page 6 Rated operational current I e (IEC/EN 60947 5 1) AC12 (resistive) at 230 V 4 A AC15 (inductive) at 230 V 3 A DC12 (resistive) at 24 V 4 A DC13 (inductive) at 24 V 1.5 A AC rating (UL 508) utilization category (Control B 300 Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal 5 A current at B 300 max. making / breaking 3600/360 VA apparent power at B 300 Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime AC12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit n/c contact 6 A fast acting protection (IEC/EN 60947 5 1) n/o contact 10 A fast acting 4 - Electronic timer CT-ARS.11 Data sheet

General data MTBF on request Duty time 100 % Dimensions (W x H x D) product dimensions 22.5 x 85.6 x 103.7 mm (0.89 x 3.37 x 4.08 in) Weight packaging dimensions 97 x 109 x 30 mm (3.82 x 4.29 x 1.18 in) Screw connection technology Easy Connect Technology (Push-in) net weight 0.106 kg (0.234 lb) 0.100 kg (0.220 lb) gross weight 0.128 kg (0.282 lb) 0.122 kg (0.269 lb) Mounting DIN rail (IEC/EN 60715), snap on mounting without any tool Mounting position any Minimum distance to other units vertical not necessary horizontal not necessary Material of housing UL 94 V-0 Degree of protection housing IP50 terminals IP20 Electrical connection Screw connection technology Easy Connect Technology (Push-in) Wire size fine strand with(out) wire end ferrule 1 x 0.5-2.5 mm² (1 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) - Environmental data Ambient temperature rangess operation 25...+60 C storage 40...+85 C Damp heat, cyclic (IEC/EN 60068 2 30) 6 x 24 h cycle, 55 C, 95 % RH Vibration, sinusoidal (IEC/EN 60068 2 6) functioning 40 m/s 2, 10-58/60-150 Hz resistance 60 m/s 2, 10-58/60-150 Hz, 20 cycles Vibration, seismic (IEC/EN 60068 3 3) functioning 20 m/s² Shock, half sine (IEC/EN 60068 2 27) functioning 100 m/s 2, 11 ms, 3 shocks/direction resistance 300 m/s 2, 11 ms, 3 shocks/direction Isolation data Rated insulation voltage U i input circuit / output circuit 500 V Rated impulse withstand voltage U imp between all 4 kv; 1.2/50 µs isolated circuits (IEC/EN 60664 1, VDE 0110) Power frequency withstand voltage test between all isolated circuits (test voltage) routine test: 2.0 kv; 50 Hz, 1 s type test: 2.5 kv; 50 Hz, 1 min Basic insulation (IEC/EN 61140) input circuit / output circuit 500 V Protective separation (IEC/EN 61140; IEC/EN 50178; input circuit / output circuit 250 V VDE 0106 part 101 and part 101/A1) Pollution degree 3 (IEC/EN 60664-1, VDE 0110) Overvoltage category (IEC/EN 60664-1, VDE 0110) III Data sheet Electronic timer CT-ARS.11-5

Standards Product standard IEC 61812 1, EN 61812 1 + A11, DIN VDE 0435 part 2021 Low Voltage Directive EMC Directive RoHS Directive 2006/95/EC 2004/108/EC 2002/95/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000 6 1, IEC/EN 61000 6 2 electrostatic discharge IEC/EN 61000 4 2 Level 3, 6 kv / 8 kv radiated, radio-frequency, electromagnetic field IEC/EN 61000 4 3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) electrical fast transient / burst IEC/EN 61000 4 4 Level 3, 2 kv / 5 khz surge IEC/EN 61000 4 5 Level 4, 2 kv A1 A2 conducted disturbances, induced by radiofrequency fields IEC/EN 61000 4 6 Level 3, 10 V harmonics and interharmonics IEC/EN 61000 4 13 Level 3 Interference emission IEC/EN 61000 6 3, IEC/EN 61000 6 4 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B Technical diagrams Load limit curves AC voltage [V] resistive load DC voltage [V] resistive load AC current [A] 2CDC 252 149 F0206 DC current [A] 2CDC 252 150 F0206 AC load (resistive) DC load (resistive) Derating factor F 1.0 0.9 0.8 Switching cycles 0.7 250 V resistive load 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ 2CDC 252 124 F0206 Switching current [A] 2CDC 252 148 F0206 Derating factor F for inductive AC load Contact lifetime 6 - Electronic timer CT-ARS.11 Data sheet

Dimensions in mm and inches 113.4 4.47 105.9 4.17 22.5 0.89 85.6 3.37 103.7 4.08 2CDC 252 009 F0011 Accessories in mm and inches 22.5 0.89 8 0.32 4.8 0.19 6.5 0.256 62.5 2.461 60 2.362 70 2.756 10 11.5 0.394 0.453 20 0.787 2CDC 252 008 F0010 3A11 20.787 8.315 2CDC 252 186 F0005 68 2.68 front to back 110.5 4.31 2CDC 252 010 F0011 ADP.01 Adapter for screw mounting MAR.01 Marker label COV.11 Sealable transparent cover Further documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x CT-AHS, CT-ARS, CT-MBS, CT-MFS Instruction manual 1SVC 730 010 M0000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products -> Electronic Relays and Controls -> Time Relays Data sheet Electronic timer CT-ARS.11-7

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 111 112 D0201 printed in Germany (07/2011) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2011 ABB All rights reserved