Quick Start Guide. Unidrive M200/201. Frame sizes 5 to 6. Flexible machine integration through communications. Part Number: Issue: 6

Similar documents
Unidrive M Quick Start Guide. Frame sizes 1 to 4. Value drive with quality and performance for open loop applications

Quick Start Guide. Unidrive M200/201. Frame sizes 1 to 4. Flexible machine integration through communications. Part Number: Issue: 5

Quick Start Guide. Unidrive M300. Frame sizes 1 to 4. Enhance throughput with Machine Safety. Part Number: Issue: 5

Quick Start Guide. Unidrive M200/201. Frame sizes 1 to 4. Flexible machine integration through communications. Part Number: Issue: 6

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 2

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Control Quick Start Guide. Unidrive M300. Enhance throughput with machine safety. Part Number: Issue: 2

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 3

Control Quick Start Guide. Unidrive M200/ M201. Flexible machine integration through communications. Part Number: Issue: 4

Unidrive M Quick Start Guide. Frame sizes 1 to 4. Value drive with quality and performance for open loop applications

Unidrive M400. Control Quick Start Guide

Control User Guide. Unidrive M100/101. Variable Speed AC drive for induction motors. Part Number: Issue: 1

Control User Guide. Unidrive M100/101. Variable Speed AC drive for induction motors. Part Number: Issue: 3

Parameter Reference Guide. KBG2 Series. RFC-A Mode

Parameter Reference Guide. Unidrive M200. RFC-A Mode. Issue:

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

Parameter Reference Guide. Unidrive M701. Regeneration Mode. Issue:

SM-I/O Plus. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user. Réf en / a

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 7.5kW, 0.33hp to 10hp

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Commander SK. EF Getting Started Guide

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Unidrive M400. User Guide. Model size 1 to 8. Variable Speed AC drive for induction motors. Part Number: Issue: 6

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 7.5kW, 0.33hp to 10hp

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Control User Guide. Unidrive M200/M201. Variable Speed AC drive for induction motors. Part Number: Issue: 2

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Control User Guide. Unidrive M200/M201. Variable Speed AC drive for induction motors. Part Number: Issue: 1

Commander SK. Getting Started Guide. AC variable speed drive for 3 phase induction motors. Model sizes 2 to 6. Part Number: Issue: 8

Unidrive M600. User Guide. Model size 3 to 10. Universal Variable Speed AC drive for induction and permanent magnet motors

Unidrive M200/201. User Guide. Model size 1 to 6. Variable Speed AC drive for induction motors. Part Number: Issue: 4

UNIDRIVE M200. Manufacturing Automation drives. Flexible machine integration through communications

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

EF User Guide SM-I/O 120V. Solutions Module for: Unidrive SP Commander SK. Part Number: Issue Number: 2

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

SM-I/O Lite and SM-I/O Timer Solutions module for DIGIDRIVE SK and UNIDRIVE SP User guide

KBG2 Series. Control User Guide. Variable Speed AC drive for induction motors.

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

User Guide. Unidrive M700. Frame sizes 3 to 10. Low voltage DC operation in Elevator Applications. Issue: 1

MINI-PS AC/10-15DC/8

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

User Guide SM-I/O PELV. Solutions Module for: Unidrive SP Commander SK. Part Number: Issue: 3.

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

EF User Guide. SM-I/O Lite SM-I/O Timer. Solutions Module for: Unidrive SP Commander SK. Part Number: Issue: 4

Macro Guide. Affinity. Model sizes 1 to 6. Building Automation HVAC/R drive. Part Number: Issue: 1.

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

PowerFlex 40 Sample Specification

Optidrive Applications Support Library

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Getting Started Guide. Unidrive M700 Unidrive M701. Model sizes 3 to 10. Part Number: Issue: 7.

SM-RESOLVER. Solutions module for UNIDRIVE SP. User guide. This manual is to be given to the end user

Getting Started Guide. Powerdrive F300. Frame Sizes 3 to 10. Part Number: Issue: 1.

Unidrive M200 Integration through flexible communications

Unidrive M100. User Guide. Model size 1 to 4. Variable Speed AC drive for induction motors. Part Number: Issue: 1

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3

Control User Guide. Unidrive M400. Variable Speed AC drive for induction motors. Part Number: Issue: 3

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Firmware Manual - EC Series Drives

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

Frame 5 to 6 Power Installation Guide

SENSORLESS VECTOR CONTROL

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

SM-Encoder Plus SM-Encoder Output Plus

User Guide. SM-I/O 24V Protected. Solutions Module for: Unidrive SP Commander SK Commander GP20. Part Number: Issue: 3

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

Unidrive M700 Unidrive M701 Unidrive M702

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ETHERNET/IP & PROFINET MODULE

POWERDRIVE, PROXIDRIVE, VARMECA

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Optidrive Applications Support Library

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTE-B. Catalog. Edition 02/ / EN

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0.

Getting Started Guide. Unidrive M700 Unidrive M701. Part Number: Issue: 5.

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Commander SX Commander SX

SMVector Additional I/O Module Installation and Operation Manual

Transcription:

Quick Start Guide Unidrive M00/0 Frame sizes to 6 Flexible machine integration through communications Part Number: 08-008-06 Issue: 6

This guide is intended to provide basic information required in order to set-up a drive to run a motor. For more detailed installation information, please refer to the Unidrive M00/M0 User Guide which is available to download from: www.controltechniques.com/userguides or www.emersonindustrial.com/en-en/leroy-somer-motorsdrives/downloads/pages/manuals.aspx Warnings, Cautions and Notes A Warning contains information which is essential for avoiding a safety hazard. WARNING CAUTION NOTE A Caution contains information which is necessary for avoiding a risk of damage to the product or other equipment. A Note contains information, which helps to ensure correct operation of the product. WARNING This guide does not include safety information. Incorrect installation or operation of the drive, could cause personnel injury or equipment damage. For essential safety information, please refer to the Unidrive M00/M0 User Guide or the safety booklet supplied with the drive. Copyright July 0

Contents Product information...6. Ratings... 6 Options... 3 Mechanical installation...8 Electrical installation...0. AC supply requirements... 0. External braking resistor... 0.3 Ground leakage.... Control terminal configurations and wiring.... EMC... Keypad and display...3. Saving parameters.... Restoring parameter defaults... 6 Basic parameters (Menu 0)... 6. Menu 0: Basic parameters... Running the motor...30 8 NV Media Card Operation...3 UL listing information...3. General... 3. Mounting... 3.3 Environment... 3. Electrical ratings... 3. Opening of branch circuit... 3.6 Electrical installation... 3. Motor overload protection... 33.8 Motor overspeed protection... 33. Thermal memory retention... 33.0 Group installation... 33. UL listed accessories... 3 Unidrive M00-M0 Quick Start Guide

Control Techniques Ltd The Gro Newtown Powys UK SY6 3BE Declaration of Conformity Moteurs Leroy-Somer Usine des Agriers Boulevard Marcellin Leroy CS00 6 Angoulême Cedex France This declaration applies to Unidrive M variable speed drive products, comprising models numbers as shown below: Maaa-bbcddddd Valid characters: aaa 00, 0, 00, 0, 300, 00 bb 0, 0, 03, 0, 0, 06, 0, 08 c,,, or 6 000, 000, 00033, 000 0003, 0008, 0003, 000, 0003, 00033, 000, 000, 0006, 000 0006, 0003, 000, 0000 ddddd 0033, 003, 000, 006 00030, 0000, 0006, 000, 000, 00300 0000, 000, 000, 0030, 000, 00330, 0030, 000, 000, 000 000, 000, 000, 00380, 000, 000, 000, 0060, 00660, 000, 000, 00830, 0000 00630, 00860, 060, 030, 030, 00 The AC variable speed drive products listed above have been designed and manufactured in accordance with the following European harmonized standards: EN 6800--:00 EN 6800-3:00 EN 6000-6-:00 EN 6000-6-:00 EN 6000-3-:006 EN 6000-3-3:008 Adjustable speed electrical power drive systems - safety requirements - electrical, thermal and energy Adjustable speed electrical power drive systems. EMC product standard including specific test methods Electromagnetic compatibility (EMC). Generic standards. Immunity standard for industrial environments Electromagnetic compatibility (EMC). Generic standards. Emission standard for industrial environments Electromagnetic compatibility (EMC), Limits, Limits for harmonic current emissions (equipment input current <6 A per phase) Electromagnetic compatibility (EMC), Limits, Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current <6 A EN 6000-3-:006 Applicable where input current <6 A. No limits apply for professional equipment where input power > kw. Unidrive M00-M0 Quick Start Guide

These products comply with the Low Voltage Directive 006//EC, the Electromagnetic Compatibility Directive 00/08/EC. T. Alexander VP Technology Date: th May 0 Place: Newtown, Powys. UK These electronic drive products are intended to be used with appropriate motors, controllers, electrical protection components and other equipment to form complete end products or systems. Compliance with safety and EMC regulations depends upon installing and configuring drives correctly, including using the specified input filters. The drives must be installed only by professional assemblers who are familiar with requirements for safety and EMC. The assembler is responsible for ensuring that the end product or system complies with all the relevant laws in the country where it is to be used. Refer to the User Guide. An EMC Data Sheet is also available giving detailed EMC information. Unidrive M00-M0 Quick Start Guide

Product information. Ratings Model Input phases Max. cont input current Max input fuse rating Nominal cable size European USA Input Output Input Output Max. cont output current Output current Nominal power Motor power A A mm mm AWG AWG A kw hp 0000 3 0 0 0 8 8.. 0000 0 6 6 8 8 0 000300 30 0 6 6 8 8 30 0 3 000030 0 0. 0. 6 6 3. 00000 0. 3 00006 0.. 6. 0600330 8 63 6 6 33. 0 06000 6 63 3 3 060030 36 63 0 0 6 6 3 06000 6 63 6 6 8. 30 06000 60 63 3 3 30 060000 3 3 0.. 0.. 06000 0 0 0. 0 06000 0 6 6 0 0 060030 63 0 0 8 8 3 0 06000 3 63 0 0 6 6 8. 060030 63 6 0 6 6 3 30 NOTE Figure - The nominal cable sizes shown in the table above, are provided as a guide only. Ensure that the cables used conform to the local wiring regulations. Model number structure Derivative Electrical Specifications M00-03 0003 A Product line: Frame size: Voltage rating: - 00 V (00-0 ± 0 %) - 00 V (00-0 ± 0 %) - 00 V (380-80 ± 0 %) - V (00 - ± 0 %) 6-60 V (00-60 ± 0 %) Drive Format : A AC in AC out Current Rating : Heavy Duty current rating x0 6 Unidrive M00-M0 Quick Start Guide

Options Table - System Integration (SI) option module identification Type Option module Color Name Further details Purple SI-PROFIBUS Medium Grey SI-DeviceNet Fieldbus Light Grey SI-CANopen See relevant option module User Guide Beige SI-Ethernet Brown Red SI-EtherCAT Automation (I/O expansion) Orange SI-I/O Table - Adaptor Interface (AI) option module identification Type Option module Name Further Details Communications AI-8 Adaptor See Drive User Guide Backup AI-Backup Adaptor Unidrive M00-M0 Quick Start Guide

3 Mechanical installation The drives can be panel mounted with 0 mm space between the drives. For further information on mechanical installation refer to the Drive User Guide. A B A M mm (0.3 in) H M To remove the terminal cover, use a flat bladed screwdriver to rotate the terminal cover locating clip by approximately 30 in a counter clockwise direction, and then slide the cover down. Drive H W D M M A B Size mm in mm in mm in mm in mm in mm in mm in mm in 3. 3.6.6 3.8 06. 6. 0.3 0* 0 00 3. 6 3. 0 8.3 8. 38. 6. 0.3 0* 0 Table 3- B Tools required W M Tool Location Size 6 Small terminal screwdriver Control & relay terminals mm Flat-bladed screwdriver Control terminal cover Pozidrive screwdriver Power terminal covers mm Flat-bladed screwdriver AC & motor terminals mm nut driver DC and braking terminals 0 mm nut driver AC, motor, DC & braking terminals D 8 Unidrive M00-M0 Quick Start Guide

Table 3- Recommended torque settings Model size Terminal block description Torque settings All Control terminals 0. N m (0. lb ft) Relay terminals 0. N m (0. lb ft) AC, motor, DC & braking terminals. N m (. Ib ft) Ground terminals.0 N m (. Ib ft) 6 AC, motor, DC, braking & ground terminals 6.0 N m (. Ib ft) Figure 3- Feature diagram (size shown) 8 0 Key. Rating label. Relay connections 3. Option module slot. Motor connections. Ground connections 6. AC supply connections. Control connections 8. DC bus +. DC bus - 0. Braking terminal 3 6 U V W Detailed view of motor connections (), and AC supply connections (6), viewed from underside of drive Unidrive M00-M0 Quick Start Guide

Electrical installation An overlay of the electrical connections / terminals is included on the back page of this manual.. AC supply requirements Voltage: 00 V drive: 00 V to 0 V ±0 % 00 V drive: 00 V to 0 V ±0 % 00 V drive: 380 V to 80 V ±0 % V drive: 00 V to V ±0 % Number of phases: 3 Maximum supply imbalance: % negative phase sequence (equivalent to 3 % voltage imbalance between phases). Frequency range: 8 to 6 Hz For UL compliance only, the maximum supply symmetrical fault current must be limited to 00 ka.. External braking resistor WARNING Overload protection When an external braking resistor is used, it is essential that an overload protection device is incorporated in the braking resistor circuit; as shown in the electrical diagram on the back cover... Minimum resistance values and peak power rating for the braking resistor at 0 C (0 F) Table - Braking resistor resistance and power rating (00 V) Model Minimum resistance* Ω Instantaneous power rating kw Table - Braking resistor resistance and power rating (00 V) Continuous power rating kw 0000 6. 0.3 8.6 0600330.6 8.6. 06000 6. Model Minimum resistance* Ω Instantaneous power rating kw Continuous power rating kw 0000 3.. 6. 000300 8 3..6 060030.6 06000 3.8 06000 3. 0 Unidrive M00-M0 Quick Start Guide

Table -3 Braking resistor resistance and power rating ( V) Model * Resistor tolerance: ±0 % Minimum resistance* Ω.3 Ground leakage Instantaneous power rating kw Continuous power rating kw 000030.6 00000 80..6 00006 6. 060000 8. 06000.3 06000 6.3 3 060030. 06000. 060030 3. The ground leakage current depends upon whether the internal EMC filter is installed or not. The drive is supplied with the filter installed. Instructions for removing the internal filter are given in section.. Internal EMC filter on page. With internal filter installed: Size and 6: 8 ma* AC at 00 V 0 Hz 30μA DC with a 600 V DC bus (0 MΩ) *Proportional to the supply voltage and frequency. With internal filter removed: < ma NOTE WARNING WARNING The above leakage currents are just the leakage currents of the drive with the internal EMC filter connected and do not take into account any leakage currents of the motor or motor cable. When the internal filter is installed the leakage current is high. In this case a permanent fixed ground connection must be provided, or other suitable measures taken to prevent a safety hazard occurring if the connection is lost. When the leakage current exceeds 3. ma, a permanent fixed ground connection must be provided using two independent conductors each with a cross-section equal to or exceeding that of the supply conductors. The drive is provided with two ground connections to facilitate this. Both ground connections are necessary to meet EN 6800- -: 00. Unidrive M00-M0 Quick Start Guide

.3. Use of residual current device (RCD) There are three common types of ELCB / RCD:. AC - detects AC fault currents. A - detects AC and pulsating DC fault currents (provided the DC current reaches zero at least once every half cycle) 3. B - detects AC, pulsating DC and smooth DC fault currents Type AC should never be used with drives. Type A can only be used with single phase drives Type B must be used with three phase drives Only type B ELCB / RCD are suitable for use with 3 phase inverter drives. WARNING If an external EMC filter is used, a delay of at least 0 ms should be incorporated to ensure spurious trips are not seen. The leakage current is likely to exceed the trip level if all of the phases are not energized simultaneously.. Control terminal configurations and wiring 00.00 Drive Configuration RW Txt PT US OL RFC-A AV (0), AI (), AV.Pr (), AI.Pr (3), Preset (), Pad (), Pad.Ref (6), E.Pot (), torque (8), Pid () AV (0) Value Text Description 0 AV Analog input (voltage) Analog input (voltage) selected by terminal (Local/ Remote) AI Analog input (current) or Analog input (voltage) selected by terminal (Local/Remote) AV.Pr Analog input (voltage) or 3 presets selected by terminal 3 AI.Pr Analog input (current) or 3 presets selected by terminal Preset Four presets selected by terminal Pad Keypad reference 6 Pad.Ref Keypad reference with terminal control E.Pot Electronic Potentiometer 8 torque Torque mode, Analog input (current frequency reference) or Analog input (voltage torque reference) selected by terminal Pid Pid mode, Analog input (current feedback source) and Analog input (voltage reference source) This parameter is used to automatically setup the user programmable area in the level parameter set according to drive configurations. Other default values may also be changed by drive configuration. Parameters are stored in EEPROM automatically following a configuration change. Defaults are loaded before drive configuration changes are made. Defaults loaded are defined by Defaults Previously Loaded (.06). Action will only occur if the drive is inactive, not in UU state and no User Actions are running. Otherwise, the parameter will return to its pre altered value on exit from edit mode. All parameters are saved if this parameter changes. Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = AV (0 Hz) 0k 0k Voltage speed reference input (AI ) + 0 V output Voltage speed reference input (AI ) 0 Analog output (motor frequency) + V output (zero frequency) Drive enable 3 Run forward Run reverse Analog input / input select Figure - Pr 00.00 = AV (60 Hz) 0k 0k Voltage speed reference input (AI ) + 0 V output Voltage speed reference input (AI ) 0 Analog output (motor frequency) + V output (zero frequency) Not stop 3 Run Jog forward Analog input / input select Unidrive M00-M0 Quick Start Guide 3

Figure -3 Pr 00.00 = AI (0 Hz) Current speed reference input Current speed reference input (AI ) + 0 V output 0k Voltage speed reference input (AI ) 0 Analog output (motor frequency) + V output (zero frequency) Drive enable 3 Run forward Run reverse Analog input / input select Figure - Pr 00.00 = AI (60 Hz) Current speed reference input Current speed reference input (AI ) + 0 V output 0k Voltage speed reference input (AI ) 0 Analog output (motor frequency) + V output (zero frequency) Not stop 3 Run Jog forward Analog input / input select Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = AV.Pr (0 Hz) 0k Voltage speed reference input (AI ) + 0 V output Reference select Analog output (motor frequency) + V output 0 3 (zero frequency) Drive enable Run forward Run reverse Reference select Terminal Terminal Reference selected 0 0 Analog reference (0.036) 0 Preset speed (0.0) 0 Preset speed 3 (0.03) Preset speed (0.0) Figure -6 Pr 00.00 = AV.Pr (60 Hz) 0k Voltage speed reference input (AI ) + 0 V output Reference select Analog output (motor frequency) + V output 0 3 (zero frequency) Not stop Run Jog forward Reference select Terminal Terminal Reference selected 0 0 Analog reference (0.036) 0 Preset speed (0.0) 0 Preset speed 3 (0.03) Preset speed (0.0) Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = AI.Pr (0 Hz) Current speed reference input Current speed reference input (AI ) + 0 V output Reference select Analog output (motor frequency) + V output 0 3 (zero frequency) Drive enable Run forward Run reverse Reference select Terminal Terminal Reference selected 0 0 Analog reference (0.036) 0 Preset speed (0.0) 0 Preset speed 3 (0.03) Preset speed (0.0) Figure -8 Pr 00.00 = AI.Pr (60 Hz) Current speed reference input Current speed reference input (AI ) + 0 V output Reference select 0 Analog output (motor frequency) + V output (zero frequency) 3 Not stop Run Jog forward Reference select Terminal Terminal Reference selected 0 0 Analog reference (0.036) 0 Preset speed (0.0) 0 Preset speed 3 (0.03) Preset speed (0.0) 6 Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = Preset (0 Hz) 0k Voltage speed reference input (AI ) + 0 V output Reference select Analog output (motor frequency) + V output 0 3 (zero frequency) Drive enable Run forward Run reverse Reference select Terminal Terminal Reference selected 0 0 Preset speed (0.0) 0 Preset speed (0.0) 0 Preset speed 3 (0.03) Preset speed (0.0) Figure -0 Pr 00.00 = Preset (60 Hz) 0k Voltage speed reference input (AI ) + 0 V output Reference select Analog output (motor frequency) + V output 0 3 (zero frequency) Not stop Run Jog forward Reference select Terminal Terminal Reference selected 0 0 Preset speed (0.0) 0 Preset speed (0.0) 0 Preset speed 3 (0.03) Preset speed (0.0) Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = Pad (0 Hz & 60 Hz) 0k 0k Voltage speed reference input (AI ) + 0 V output Voltage speed reference input (AI ) 0 Analog output (motor frequency) + V output (zero frequency) Drive enable When Pr 00.00 is set to Pad, to run in reverse: Set Pr 00.0 to On The keypad reference can now be set to a negative frequency to run the motor in the reverse direction. 3 Run forward Run reverse Analog input / input select Figure - Pr 00.00 = Pad.Ref (0 Hz & 60 Hz) 0k 0k Voltage speed reference input (AI ) + 0 V output Voltage speed reference input (AI ) 0 Analog output (motor frequency) + V output (zero frequency) Drive enable 3 Run forward Run reverse Analog input / input select 8 Unidrive M00-M0 Quick Start Guide

Figure -3 Pr 00.00 = E.Pot (0 Hz) 0k Voltage speed reference input (AI ) + 0 V output DOWN 0 Analog output (motor frequency) + V output (zero frequency) Drive enable When Pr 00.00 is set to E.Pot, the following parameters may need to be adjusted: Pr 0.03: Motorized pot up/down rate (s/00 %) Pr 0.0: Motorized pot bipolar select (0 = unipolar, = bipolar) Pr 0.0: Motorized pot mode: 0 = zero at powerup, = last value at power-up, = zero at powerup and only change when the drive is running, 3 = last value at power-up and only change when drive is running, = zero at power-up and drive disabled, only change when the drive is running. 3 Run forward Run reverse UP Figure - Pr 00.00 = E.Pot (60 Hz) 0k Voltage speed reference input (AI ) + 0 V output DOWN 0 3 Analog output (motor frequency) + V output (zero frequency) Not stop Run Jog forward When Pr 00.00 is set to E.Pot, the following parameters may need to be adjusted: Pr 0.03: Motorized pot up/down rate (s/00 %) Pr 0.0: Motorized pot bipolar select (0 = unipolar, = bipolar) Pr 0.0: Motorized pot mode: 0 = zero at powerup, = last value at power-up, = zero at power-up and only change when the drive is running, 3 = last value at power-up and only change when drive is running, = zero at power-up and drive disabled, only change when the drive is running. UP Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = torque (0 Hz) Current speed reference input Current speed reference input (AI ) + 0 V output 0k Torque reference input (AI ) Analog output (motor frequency) WARNING When torque mode is selected and the drive is connected to an unloaded motor, the motor speed may increase rapidly to the maximum speed (Pr 00.00 +0 %) + V output 0 (zero frequency) Drive enable Run forward 3 Run reverse Torque mode select Figure -6 Pr 00.00 = torque (60 Hz) Current speed reference input Current speed reference input (AI ) + 0 V output 0k Torque reference input (AI ) WARNING When torque mode is selected and the drive is connected to an unloaded motor, the motor speed may increase rapidly to the maximum speed (Pr 00.00 +0 %) Analog output (motor frequency) + V output 0 (zero frequency) Not stop Run 3 Jog forward Torque mode select 0 Unidrive M00-M0 Quick Start Guide

Figure - Pr 00.00 = Pid (0 Hz) - 0 ma PID feedback input 0-0 V PID Reference input PID feedback input (AI ) + 0 V output PID reference input (AI ) When Pr 00.00 is set to Pid, the following parameters may need to be adjusted: Pr.00: PID proportional gain Pr.0: PID integral gain Pr.006: PID feedback invert Pr.03: PID output upper limit (%) Pr.0: PID output lower limit (%) 0 3 Analog output (motor frequency) + V output (zero frequency) Drive enable Run forward Run reverse PID enable Figure -8 Pr 00.00 = Pid (60 Hz) - 0 ma PID feedback input 0-0 V PID Reference input PID feedback input (AI ) + 0 V output PID reference input (AI ) When Pr 00.00 is set to Pid, the following parameters may need to be adjusted: Pr.00: PID proportional gain Pr.0: PID integral gain Pr.006: PID feedback invert Pr.03: PID output upper limit (%) Pr.0: PID output lower limit (%) Analog output (motor frequency) + V output 0 (zero frequency) Not stop Run 3 Jog forward PID enable Unidrive M00-M0 Quick Start Guide

. EMC.. Internal EMC filter It is recommended that the internal EMC filter be kept in place unless there is a specific reason for removing it. If the drive is used as a motoring drive as part of a regen system, then the internal EMC filter must be removed. The internal EMC filter reduces radio-frequency emission into the line power supply. For longer motor cables, the filter continues to provide a useful reduction in emission levels and when used with any length of shielded motor cable up to the limit for the drive, it is unlikely that nearby industrial equipment will be disturbed. It is recommended that the filter be used in all applications unless the instructions given above require it to be removed, or where the ground leakage current is unacceptable... Removing the internal EMC filter The supply must be disconnected before removing the internal EMC filter. WARNING Figure - Removal of the size internal EMC filter 3 Remove the three M terminal nuts (). Lift away the cover () to expose the M Torx internal EMC filter removal screw. Finally remove the M Torx internal EMC filter removal screw (3) to electrically disconnect the internal EMC filter. Unidrive M00-M0 Quick Start Guide

..3 Further EMC precautions Further EMC precautions are required if more stringent EMC emission requirements apply: Operation in the first environment of EN 6800-3: 00 Conformity to the generic emission standards Equipment which is sensitive to electrical interference operating nearby In this case it is necessary to use: The optional external EMC filter A shielded motor cable, with shield clamped to the grounded metal panel A shielded control cable, with shield clamped to the grounded metal panel Full instructions are given in the Drive User Guide. A full range of external EMC filters are also available for use with Unidrive M00/M0. Keypad and display The keypad and display provide information to the user regarding the operating status of the drive and trip codes, and provide the means for changing parameters, stopping and starting the drive, and the ability to perform a drive reset. Figure - Unidrive M00 keypad detail Figure - Unidrive M0 keypad detail V A Hz rpm % 6 6 3 () The Enter button is used to enter parameter view or edit mode, or to accept a parameter edit. ( / ) The Navigation keys can be used to select individual parameters or to edit parameter values. (3) The Stop / Reset key is used to stop and reset the drive in keypad mode. It can also be used to reset the drive in terminal mode. () The Start key is used to start the drive in keypad mode. (6) The Escape key is used to exit from the parameter edit / view mode. () The Speed ref pot is used to control the speed reference in keypad mode (only on Unidrive M0). Unidrive M00-M0 Quick Start Guide 3

Table - Status indications String inh rdy. Saving parameters Description The drive is inhibited and cannot be run. The Drive Enable signal is not applied to the drive enable terminal or Pr 06.0 is set to 0. The other conditions that can prevent the drive from enabling are shown as bits in Enable Conditions (06.00) The drive is ready to run. The drive enable is active, but the drive inverter is not active because the final drive run is not active Drive output stage Disabled Disabled Stop The drive is stopped / holding zero speed. Enabled S.Loss Supply loss condition has been detected Enabled dc inj The drive is applying dc injection braking Enabled Er UV The drive has tripped and no longer controlling the motor. The trip code appears on the display. The drive is in the under voltage state either in low voltage or high voltage mode. Disabled Disabled When changing a parameter in Menu 0, the new value is saved when pressing the Enter button to return to parameter view mode from parameter edit mode. If parameters have been changed in the advanced menus, then the change will not be saved automatically. A save function must be carried out. Procedure. Select Save'* in Pr mm.000 (alternatively enter a value of 000* in Pr mm.000). Either: Press the red reset button Carry out a drive reset through serial communications by setting Pr 0.038 to 00 * If the drive is in the under voltage state (i.e. when the AI-Backup adaptor terminals are being supplied from a + Vdc supply) a value of 00 must be entered into Pr mm.000 to perform a save function.. Restoring parameter defaults Restoring parameter defaults by this method saves the default values in the drives memory. User security status (00.00) and User security code (00.0) are not affected by this procedure). Procedure. Ensure the drive is not enabled, i.e. terminal is open or Pr 06.0 is OFF (0). Select 'Def.0 or 'Def.60' in Pr mm.000. (alternatively, enter 33 (0 Hz settings) or (60 Hz settings) in Pr mm.000). 3. Either: Press the red reset button Carry out a drive reset through serial communications by setting Pr 0.038 to 00 Unidrive M00-M0 Quick Start Guide

6 Basic parameters (Menu 0) Menu 0 is used to bring together various commonly used parameters for basic easy set up of the drive. All the parameters in Menu 0 appear in other menus in the drive (denoted by { }). Menus can be used to configure the parameters in Menu 0. 6. Menu 0: Basic parameters 00.00 Parameter Minimum Reference Clamp Range( ) Default( ) OL RFC-A OL RFC-A ±VM_NEGATIVE_REF_ CLAMP Hz Type 0.00 Hz RW Num US 00.00 Maximum Reference Clamp ±VM_POSITIVE_REF_ CLAMP Hz 0Hz default: 0.00 Hz 60Hz default: 60.00 Hz RW Num US 00.003 Acceleration Rate ±VM_ACCEL_RATE s.0 s RW Num US 00.00 Deceleration Rate ±VM_ACCEL_RATE s 0.0 s RW Num US 00.00 Drive Configuration AV (0), AI (), AV.Pr (), AI.Pr (3), Preset (), Pad (), Pad.Ref (6), E.Pot (), torque (8), Pid () 00.006 Motor Rated Current ±VM_RATED_CURRENT A 00.00 Motor Rated Speed 0.0 to 80000.0 rpm AV (0) RW Txt PT US Maximum Heavy Duty Rating (.03) A 0Hz default: 00.0 rpm 60Hz default: 800.0 rpm 0Hz default: 0.0 rpm 60Hz default: 0.0 rpm RW Num RA US RW Num US 00.008 Motor Rated Voltage ±VM_AC_VOLTAGE_SET V drive: 30 V 0 drive: 30 V 0 drive 0 Hz: 00 V 0 drive 60 Hz: 60 V V drive: V 6 drive: 60 V RW Num RA US 00.00 Motor Rated Power Factor 00.00 User Security Status 0.00 to.00 0.8 RW Num RA US LEVEL.0 (0), ALL (), r.only.0 (), r.only.a (3), Status (), no.acc() LEVEL.0 (0) RW Num ND NC PT 00.0 Jog Reference 0.00 to 300.00 Hz.0 Hz RW Num US 00.06 Analog Input Mode -0.S (-6), 0-.S (-), -0.L (-), 0-.L (-3), -0.H (-), 0-.H (-), 0-0 (0), 0-0 (), -0.tr (), 0-.tr (3), -0 (), 0- (), Volt (6) Volt (6) RW Txt US 00.0 Bipolar Reference Enable Off (0) or On () Off (0) RW Bit US 00.08 Preset Reference ±VM_SPEED_FREQ_ REF Hz 0.00 Hz RW Num US 00.0 User Security Code 0 to 0 RW Num ND NC PT US 00.0 Power-up Keypad Control Mode Reference Reset (0), Last (), Preset () Reset (0) RW Txt US Unidrive M00-M0 Quick Start Guide

Parameter 00.08 Ramp Mode Select 00.0 Ramp Enable 00.030 Parameter Cloning 00.03 Stop Mode 00.03 Dynamic V to F Select / Flux Optimization Select 00.033 Catch A Spinning Motor Range( ) Fast (0), Std (), Std.bst (), Fst.bst (3) Off (0) or On () None (0), read (), Prog (), Auto (3), boot () Coast (0), rp (), rp.dc I (), dc I (3), td.dc I (), dis (), No.rp (6) Std () RW Txt US On () RW Bit US None (0) RW Txt NC US rp () RW Txt US 0 to 0 RW Num US dis (0), Enable (), Fr.Only (), Rv.Only (3) Default( ) OL RFC-A OL RFC-A dis (0) RW Txt US 00.03 Digital Input Select Input (0), th.sct (), th (), th.notr (3), Fr () Input (0) RW Txt US 00.03 Digital Output Control 0 to 0 RW US 00.036 Analog Output Control 0 to 0 RW US Type 00.03 Maximum Switching Frequency 0.66 (0), (), (), 3 (3), (), 6 (), 8 (6), (), 6 (8) khz (), 3 (3), (), 6 (), 8 (6), (), 6 (8) khz 3 (3) khz RW Txt US 00.038 Auto-tune 0 to 0 to 3 0 RW Num NC US 00.03 Motor Rated Frequency 0.00 to VM_SPEED_FREQ_REF_ UNIPOLAR Hz 0Hz: 0.00 Hz 60Hz: 60.00 Hz RW Num RA US 00.00 Number of Motor Poles* Auto (0) to 3 (6) Auto 0 RW Num US 00.0 Control Mode 00.0 Low Frequency Voltage Boost 00.03 Serial Baud Rate Ur.S (0), Ur (), Fd (), Ur.Auto (3), Ur.I (), SrE () Ur.I () RW Txt US 0.0 to.0 % 3.0 % RW Num US 300 (0), 600 (), 00 (), 00 (3), 800 (), 600 (), 00 (6), 3800 (), 600 (8), 6800 (), 00 (0) 00 (6) RW Txt US 00.0 Serial Address to RW Num US 00.0 00.06 00.0 00.08 Reset Serial Communications Brake Release Current Threshold Brake Apply Current Threshold BC Brake Release Frequency Off (0) or On () Off (0) RW ND NC 0 to 00 % 0 % RW Num US 0 to 00 % 0 % RW US 0.00 to 0.00 Hz.00 Hz RW Num US 00.0 BC Brake Apply Frequency 0.00 to 0.00 Hz.00 Hz RW Num US 00.00 BC Brake Delay 0.0 to.0 s.00 s RW Num US 00.0 BC Post-brake Release Delay 0.0 to.0 s.00 s RW Num US 6 Unidrive M00-M0 Quick Start Guide

Parameter Range( ) Default( ) OL RFC-A OL RFC-A Type 00.03 BC Initial Direction Ref (0), For (), Rev () Ref (0) RW Txt US 00.0 BC Brake Apply Through Zero Threshold 00.0 BC Enable 00.06 00.066 Frequency Controller Proportional Gain Kp Frequency Controller Integral Gain Ki 00.06 Sensorless Mode Filter 0.00 to.00 Hz 0.00 Hz RW Num US dis (0), Relay (), dig IO (), User (3) 0.000 to 00.000 s/rad 0.00 to 6.3 s /rad (0), (), 6 (), 8 (3), (), 0 () ms dis (0) RW Txt US 0.00 s/rad RW Num US 0.0 s /rad RW Num US (0) ms RW Txt US 00.06 Spin Start Boost 0.0 to 0.0.0 RW US 00.06 Action on Trip Detection 0 to 3 0 RW US 00.0 Maximum Heavy Duty Current Rating 0.00 to. A RO Num ND NC PT 00.08 Software Version 0 to RO ND NC PT 00.0 User Drive Mode OPEn.LP (), RFC-A () OPEn.LP () RW Txt ND NC PT US 00.080 User Security Status LEVEL.0 (0), ALL (), r.only.0 (), r.only.a (3), Status (), no.acc() LEVEL.O. (0) RW Txt ND PT * If this parameter is read via serial communications, it will show pole pairs. RW Read / Write ND No default value RO NC Read only Not copied Num PT Number parameter Protected parameter Bit RA Bit parameter Rating dependent Txt Text string Bin Binary parameter US User save PS Power-down save FI DE Filtered Destination Unidrive M00-M0 Quick Start Guide

Figure 6- Menu 0 logic diagram Analog input / input select Analog reference Analog input 00.06 Analog input mode Analog input 0.0 Keypad reference 0.00 Preset frequency reference Preset 00.08 Reference Pr 0.00 set > AI.Pr Pr Pad Pad.Ref E. Pot tor Pid Drive Configuration 00.00 AV 0 3 AI AV.Pr 6 8 Bipolar Reference Enable 00.0 Key X X X X Input terminals Output terminals 00.XXX Read-write (RW) parameter 00.XXX Read-only (RO) parameter The parameters are all shown in their default settings 8 Unidrive M00-M0 Quick Start Guide

RUN FORWARD 3 RUN REVERSE OL, RFC-A> FREQUENCY AT ZERO FREQUENCY 0 Analog output Maximum Reference Clamp 00.00 Minimum Reference Clamp 00.00 Ramp Enable 00.0 0.0 Torque Mode Selector RFC-A mode only 00.033 Motor parameters Ramps 00.006 ~ 00.00 Power Factor 00.003 Acceleration Rate 00.00 Deceleration Rate 00.08 Ramp Mode Select RFC-A Frequency-loop PIDgains Frequency 00.06 Controller Proportional Gain Kp 03.0 00.066 Frequency Controller Integral Gain Ki Frequency Controller Differential Feedback Gain Kd Rated Voltage Rated Speed Rated Current OL>Motor-voltage control 0.00 Estimated Motor Speed 00.0 Control mode 00.0 Low Frequency Voltage Boost 00.03 RFC-A> L L L3 _ + Drive Motor Rpm DynamicV/f Select 0.00 Power stage 00.03 Maximum Switching Frequency 0.00 Output Frequency _ + RFC-A Torque Producing Current 0.00 0.00 Current Magnitude U V W _ + BR Magnetising Current Resistor optional Unidrive M00-M0 Quick Start Guide

Running the motor This section takes a new user through all the essential steps to running a motor for the first time. Table - Open Loop and RFC-A Action Before power up Power up the drive Enter minimum and maximum speeds Detail Ensure: The drive enable signal is not given, terminal is open The run signal is not given, terminal /3 is open The motor is connected to the drive The motor connection is correct for the drive Δ or Y The correct supply voltage is connected to the drive The default setting is Open Loop vector mode. For RFC-A mode set Pr 00.0 to RFC-A, then press the stop/reset button to save the parameters. Ensure: The drive displays: Inh Enter: Minimum speed Pr 00.00 (Hz) Maximum speed Pr 00.00 (Hz) Pr 0 Pr 0 t Enter accel and decel rates Enter motor nameplate details Ready to autotune Enter: Acceleration rate Pr 00.003 (s/00 Hz) Deceleration rate Pr 00.00 (s/00 Hz) Enter: Motor rated current in Pr 00.006 (A) Motor rated speed in Pr 00.00 (rpm) Motor rated voltage in Pr 00.008 (V) Motor rated power factor in Pr 00.00 If the motor is not a standard 0/60 Hz motor, set Pr 00.03 accordingly The drive is able to perform either a stationary or a rotating autotune. The motor must be at a standstill before an autotune is enabled. To perform an autotune: Set Pr 00.038 = for a stationary autotune or set Pr 00.038 = for a rotating autotune Close the drive enable signal (apply + V to terminal ). The Autotune drive will display Rdy. Close the run signal (apply + V to terminal or 3). The display will flash tuning while the drive is performing the autotune. Wait for the drive to display Inh and for the motor to come to a standstill. Remove the drive enable and run signal from the drive. Autotune complete When the autotune has been completed, Pr 00.038 will be set to 0 Tuning of frequency controller gains (RFC-A mode only) Save parameters Save parameters Ready to run Run Increasing and decreasing speed Stopping Depending on the application, the frequency controller gains (Pr 03.00, Pr 03.0 and Pr 03.0) may need to be adjusted. Select SAVE in Pr mm.000 (alternatively enter a value of 000) and press the Stop / Reset button to save parameters. The drive is now ready to run the motor. Turning the speed potentiometer will increase and decrease the speed of the motor. To stop the motor under ramp control, open either the run forward or run reverse terminal. If the enable terminal is opened while the motor is running, the motor will coast to a stop. 00Hz Pr 03 Pr 0 Mot X XXXXXXXXX No XXXXXXXXXX kg IP I.cl F C 0 s S V Hz min - kw cosφ A 30 0.0 0.80 8.0 00.0 CN =.Nm 0 0.0 0.6 8.0.0 CN =.Nm CTP- VEN PHASE =0,6A P=0W R.F 3MN R S σl S cos I.E.C 3 (8) t 30 Unidrive M00-M0 Quick Start Guide

8 NV Media Card Operation Figure 8- Installing the AI-Backup adaptor (SD Card) 3. Identify the two plastic fingers on the underside of the AI-Backup adaptor () - then insert the two fingers into the corresponding slots in the spring-loaded sliding cover on the top of the drive.. Hold the adaptor firmly and push the spring loaded protective cover towards the back of the drive to expose the connector block () below. Press the adaptor downwards (3) until the adaptor connector locates into the drive connection below. Figure 8- Basic NV Media Card operation Drive reads all parameters from the NV Media Card Pr 00.030 = read + Pr 00.030 = Prog + Programs all drive parameters to the NV Media Card NOTE Overwrites any data already in data block Drive automatically writes to the Media Card when a parameter save is performed Pr 00.030 = Auto + Pr 00.030 = boot + Drive boots from the NV Media Card on power up and automatically writes to the Media Card when a parameter save is performed The whole card may be protected from writing or erasing by setting the read-only flag, refer to the Drive User Guide for further information. The card should not be removed during data transfer, as the drive will produce a trip. If this occurs then either the transfer should be reattempted or in the case of a card to drive transfer, default parameters should be loaded. Unidrive M00-M0 Quick Start Guide 3

UL listing information. General Drive sizes to 6 have been assessed to meet both UL and cul requirements. UL listings can be viewed online at www.ul.com. The UL file number is E30.. Mounting Drives can be installed in the following configurations: Standard or surface mounted. Refer to the Drive User Guide for further information. Bookcase mounted. Drives are mounted side by side with no space between them. This configuration minimizes the overall width of the installation..3 Environment Drives are able to meet the following UL/NEMA environmental ratings: Type. The drive must either be installed with a UL Type kit or be installed in a Type enclosure. Type. The drive must be installed in a Type enclosure. The remote keypad is rated to both UL Type and UL Type. Drives must be installed in a pollution degree environment or better.. Electrical ratings Suitable for use on a circuit capable of delivering not more than 00,000 RMS symmetrical amperes, at the rated maximum AC voltage. For information on power and current ratings, see the Drive User Guide. Fuse and circuit breaker ratings are given in the Drive User Guide. Unless indicated otherwise in the Drive User Guide, fuses may be any UL listed Class J or CC with a voltage rating of at least 600 Vac. Unless indicated otherwise in the Drive User Guide, circuit breakers may be any UL listed type, category control number: DIVQ or DIVQ, with a voltage rating of at least 600 Vac.. Opening of branch circuit The opening of the branch-circuit protective device may be an indication that a fault has been interrupted. To reduce the risk of fire or electric shock, the equipment may be examined and replaced if damaged. If burnout of the current element of an overload relay occurs, the complete overload relay must be replaced. Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes, or the equivalent..6 Electrical installation The following precautions must be observed: Drives are rated for use at 0 C and 0 C surrounding air temperature. Field wiring terminals are suitable for copper wire only, which must have a temperature rating of at least C. If the drive control stage is powered from an external power supply (+ V), the power supply must be listed or recognized to UL class with appropriate fusing. Ground connections must use UL listed closed loop (ring) terminals. 3 Unidrive M00-M0 Quick Start Guide

. Motor overload protection All models incorporate internal overload protection for the motor load that does not require the use of an external or remote overload protection device. The protection level is adjustable and the method of adjustment is provided within instructions/manual for the product. Maximum current overload is dependent on the values entered into the current limit parameters (Motoring Current Limit (0.00), Regenerative Current Limit (0.006) and Symmetrical Current Limit (0.00) entered as percentage) and the Motor Rated Current (00.006) entered in amperes). The duration of the overload is dependent on Motor Thermal Time Constant (0.0) variable up to a maximum of 3000 seconds. The default overload protection is set such that the product is capable of 0 % of the current value entered into the motor rated current parameter for 60 seconds. The product can be connected to a motor thermistor to protect the motor, in the event of a motor cooling fan failure..8 Motor overspeed protection The drive is installed with solid state motor overspeed protection. However, this feature does not provide the level of protection provided by an independent, highintegrity overspeed protection device and should not be considered as a safety function.. Thermal memory retention Drives incorporate thermal memory retention that complies fully with the requirements of UL08C. The drive is provided with motor load and speed sensitive overload protection with thermal memory retention that complies with the US National Electrical Code (NFPA 0) clause 30.6 and Underwriters Laboratories Standard UL08C, clause 0.. (a). The purpose of this protection is to protect both drive and motor from dangerous overheating in the event of repeated overload or failure to start, even if the power to the drive is removed between overload events. For full explanation of the thermal protection system, refer to the Drive User Guide for further information. In order to comply with UL requirements for thermal memory retention, it is necessary to set the Thermal Protection Mode (0.06) to zero; and the Low Frequency Thermal Protection Mode (0.0) must be set to if the drive is operated in Heavy Duty mode. Alternatively, an external thermal sensor or switch may be used as a means of motor and drive overload protection that complies with the requirements of UL08C, clause 0.. (b). This protection method is particularly recommended where independent forced cooling of the motor is used, because of the risk of overheating if the cooling is lost. External thermal sensor The drive is provided with a means to accept and act upon a signal from a thermal sensor or switch imbedded in the motor or from an external protective relay. Refer to the Drive User Guide for further information..0 Group installation.0. Definition Group Installation Definition: A motor branch circuit for two or more motors, or one or more motors with other loads, protected by a circuit breaker or a single set of fuses..0. Limitations on use All motors rated less than hp The drives may be used in group installations where each of the motors is rated hp or less. The fullload current rating of each motor must not exceed 6 A. The motor drive provides individual overload protection in accordance with the NEC clause 30.3. Unidrive M00-M0 Quick Start Guide 33

Smallest motor protected The drives may be used in group installations where the smallest motor is protected by the branch fuses or circuit breaker. Limits on the current rating of branch circuit protective fuses and circuit breakers are given in the NEC Table: 30.. Other installations The motor drives described in this user guide are not UL listed for group installation.. UL listed accessories The following options are UL listed: AI-8 Adaptor AI-Backup Adaptor Remote Keypad UL Type kit NV Media card SI-PROFIBUS SI-DeviceNet SI-CANopen SI-I/O SI-Ethernet SI-EtherCAT 3 Unidrive M00-M0 Quick Start Guide

Zero frequency Drive enable Run forward Run reverse Analog input / Analog input select Digital I/O V user Digital I/O Digital Input Digital input 3 Digital input Digital input 0 3 Analog I/O Analog input + 0 V user Analog input Analog output Frequency reference Frequency reference Frequency output Drive ok Relay BR + _ DC bus/brake AC supply Motor 3ph AC power supply L L L3 U V W Optional Main contactor power supply Stop Start / Reset Thermal protection device Braking resistor 08-008-06