G.SHDSL NTU with Fixed Serial Interfaces

Similar documents
G.SHDSL NTU DECEMBER 2006 LB510A

SmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide

G.SHDSL IAD. iprocketlink Model Quick Start Guide

Multiport Analog VoIP Router

Enterprise Session Border Router, IAD

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

T1/E1 Channelized Gigabit Router

SIP 3CX Based Private Branch Exchange

VPN Routers. OnSite 2800 Series. Quick Start Guide

Ethernet Extender. Quick Start Guide

Leased-Line Extenders over IP

Serial G.SHDSL Bridge/Router

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

Metro-Optical Transport Access Nodes

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

Enterprise Session Border Router

Multi-Port T1/E1/PRI VoIP Enterprise Gateway Router

Optical Multiplexer. Quick Start Guide

Multi-Port T1/E1/PRI Enterprise VoIP Media Gateway

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

UT3620 Triple NT1 Installation Guide

WS must be used in a temperature controlled place. It is compliant to ETS Class T

Single/Dual-Port ISDN BRI VoIP Terminal Adapter

Wiring and Cables You May Need (not supplied)

Multi-Port T1/E1/PRI VoIP Enterprise Session Border Router

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Open Applications Interface (OAI) Installation and Setup

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

SuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions

Owner s Manual. Models: ECO650LCD, ECO850LCD. Not suitable for mobile applications

Owner s Instruction Manual

SmartNode 1000 and 2000 Series

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

Tone Generator and Probe

USER MANUAL MODEL CopperLINK Ethernet Extender. This is a Class A device and is not intended for use in a residential environment.

DS-1H05 Ethernet-over-Coax Extender. User Manual

Installing the Cisco ATA

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

IC+ 56k External Data Fax Voice Modem IP568x User s Guide

RS-232/RS-422 Optical Isolator

LVN5200A-R2, rev. 1, Hardware Installation Guide

SANnet II Family Safety, Regulatory, and Compliance Manual

EX-UBT AVB/USB EXPANDER OPERATION MANUAL

Audio Cable (For CD Players Only) Sensor Board Cable

USB USB Data Transfer

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300

Telephone Line Monitor USER GUIDE

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Industrial SFP/SFP Multi-Power Mode Converter

ShoreTel IP Phone 655. Quick Install Guide & Warranty

Hotwire 5216 RTU Customer Premises Installation Instructions. Before You Begin. Wiring and Cables Needed. Document Number 5216-A2-GN10-20 June 1999

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

QH2 BLUETOOTH PHONE HUB SYSTEM USER'S GUIDE QH2 BLUETOOTH PHONE HUB SYSTEM USER'S GUIDE

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

345 Encinal Street Santa Cruz, CA

Relay Tool CUSTOMER SUPPORT INFORMATION MARCH 1997 LT037

User Manual. C Type Power Filter. Model C3 and C3BLK

FZ-VEBG11x. Cradle. Model No. FZ-VEBG11 1. Model No. U Universal R China 1: Area U: Universal R: China

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

Wa r n i n g-wa r n i n g-wa r n i n g

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Product Documentation

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

2GI. Touch Screen Wireless Keypad

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Converts any fiber optics type interface to any other fiber optics type interface.

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone

ULTRALINE HOME DSL ROUTER (MODEL 7401) ULTRALINE HOME DSL ROUTER WITH USB (MODEL 7400) USER GUIDE

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Installing the Cisco AS5400XM Universal Gateway

These tiny media converters are perfect for bringing fiber to the desktop.

Channel Switch CS. General Operating, Maintenance and Installation Manual

iconverter 2-Module Power Chassis

SleepMinder TM Non Contact Sleep Monitoring

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Overview of the Cisco 2524 and Cisco 2525 Routers

Register your product and get support at. SPP3038A. User manual

Don t plug me in just yet.

PAGEPAC 6 V INSTALLATION There are several ways to connect PagePac 6 to your telephone system.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Transcription:

DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 INFORMATION Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

WARNING The G.SHDSL NTU contains no user serviceable parts. The equipment shall be returned to Black Box for repairs, or repaired by qualified service personnel. The external power adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. The mains outlet shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker. For AC powered units, ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground. Hazardous network voltages are present in WAN ports, regardless of whether power to the G.SHDSL NTU is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the G.SHDSL NTU first. Do not work on the system or connect or disconnect cables during periods of lightning activity. For DC units, the interconnecting cables shall be rated for the proper voltage, current, anticipated temperature, flammability, and mechanical serviceability TRADEMARKS USED IN THIS MANUAL All applied-for and registered trademarks are the property of their respective owners. 2

1. Select configuration method Before powering up, you must select one of the following methods for configuring your G.SHDSL NTU: DIP Switch For deploying the G.SHDSL NTU in back-to-back applications. To use DIP-switch configuration you must first set the DIP switches to a position other than all OFF or all ON before powering-up the G.SHDSL NTU. To configure your NTU using the DIP switches, refer to the section entitled Hardware (DIP-switch) configuration in the G.SHDSL NTU Getting Started Guide. Software Configuration Allows you to modify configurable parameters by connecting a PC to the console port and issuing software commands. To use software configuration you must set all the DIP switches to the ON position before powering-up the G.SHDSL NTU. To configure your NTU via the console port, refer to section Software (CLI) configuration in the G.SHDSL NTU Getting Started Guide. 3

2. Power up the NTU Your G.SHDSL NTU comes with one of the following power supply options: External AC adaptor with detachable power cord External DC power supply with terminal block connector (model 48V-PSM) 2.1 Models with external AC adaptor 1. Connect female plug of the AC power cord to the AC adaptor provided. 2. Connect the barrel-type connector of the AC adaptor to the Power connector on the G.SHDSL NTU. 3. Insert the male plug of the AC power cord into an AC power outlet (100 240 VAC). 2.2 Models with external DC power supply 1. Strip insulation 1/4-inch from the electrical wires that will connect the DC power source to the 48VDC power supply terminal block (see Figure 1). Input: 36 60VDC, 0.13A (SELV) + N/C - ) Terminal block Input: 36 60VDC, 0.13A (SELV) ( + N/C - ) Output: 5V, 1A ( Ctr +) 48VDC Power Supply Module (-) Terminal (+) Terminal Figure 1. 48VDC power supply 2. Connect the negative (-) terminal from the power source to the negative (-) terminal on the power supply. 3. Connect the positive (+) terminal from the power source to the positive (+) terminal on the power supply 4. Connect the 48VDC output barrel-type plug to the power connector on the G.SHDSL NTU. 4

NTU Console TM / ERR Terminal DSL Power Figure 2. G.SHDSL NTU front panel 2.3 Power up indication Verify that the Power LED (see Figure 2) illuminates and remains lit. 5

3. Connect the G.SHDSL port 1. Obtain single-twisted-pair cable with an RJ-45 plug connector at each end. 2. Plug one end of the cable into the RJ-45 socket (labelled DSL) on the G.SHDSL NTU. If you are connecting to a DSL service, plug the other end of the cable into the RJ-45 wall socket that provides your G.SHDSL service. If connecting to another G.SHDSL NTU, verify the other end of the cable is connected to the DSL port on other G.SHDSL NTU and the DSL port is correctly configured. 3. When a DSL link is established, the front-panel DSL LED will turn on. 6

4. Connect the serial port Your G.SHDSL NTU comes with one of the following serial WAN ports for connection to an NTU: V.35 (DB-25F) Model ME233A X.21 (DB-15) Model ME232A T1/E1 (120-Ohm RJ-48C and dual 75-Ohm BNC connectors) Model ME231A Connect the serial cable to the G.SHDSL NTU serial port as follows: 1. Attach the male connector of the serial cable to the female serial connector on the G.SHDSL NTU. 2. Attach the other end of the cable to the serial connector on the local serial NTU. Note Note Note The V.35 interface is wired as a DCE. To connect the V.35 interface to third-party equipment wired as a DCE, you must use a tail-circuit cable. You can purchase a tail-circuit cable from a datacom-supply vendor. A tail-circuit cable will cross-over the necessary V.35 signals so that the two DCE interfaces can communicate. The X.21 interface is wired as a DCE. If you need to change the orientation to DTE, refer to section Connecting the Model ME232A (X.21) Serial Interface in the G.SHDSL NTU Series Getting Started Guide, The X.21 interface requires a cable with a male DB-15 connector. You can configure the T1/E1 interface to either recover the network clock from the T1/E1 line or supply the network clock for the T1/E1 line. 7

5. Additional information For detailed information about installing, configuring, operating, and troubleshooting, refer to the G.SHDSL NTU Series Getting Started Guide on the enclosed CD-ROM. A. Compliance Information A.1 Compliance EMC: FCC Part 15, Class A EN55022, Class A EN55024 Safety: UL 60950/CSA C22.2 N0. 60950 IEC/EN60950 PSTN Regulatory: FCC Part 68 CS03 TBR12, & TBR13 AS/ACIF S031 & S043 A.2 FCC Part 68 (ACTA) Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains among other information a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. 8

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. 5.4 Radio and TV Interference (FCC Part 15) This equipment generates and uses radio frequency energy, and if not installed and used properly that is, in strict accordance with the manufacturer's instructions may cause interference to radio and television reception. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). 5.5 Industry Canada Notice This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment. 9

This Declaration of Conformity means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas. 5.6 EC Declaration of Conformity Product Description: G.SHDSL NTU with Fixed Serial Interfaces This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity. The safety advice in the documentation accompanying the products shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device. In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling. 10

11

Copyright 2006. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746