Omega TM 4K / UHD Three-Input Switcher for HDMI and USB-C with HDBaseT and HDMI Outputs Application Programming Interface AT-OME-ST31 API
Version Information Version Release Date Notes 1 12/2018 Release AT-OME-SW32 2
The following tables provide an alphabetical list of commands available on the AT-OME-SW32. Commands can be sent using RS-232 or Telnet. There should be a 0.5 second delay between each command sent to the unit. Default port for Telnet is 23. Each command is case sensitive, do not change: capitalization, spacing, or lettering. Each command is terminated with a carriage return. If the command fails or is incorrect the feedback should be Command FAILED: followed by the sent command. IMPORTANT: Each command is terminated with a carriage-return (0x0d) and the feedback is terminated with a carriage-return and line-feed (0x0a). Command Blink CommaWait DispBtn InputStatus IPCFG IPDHCP IPStatic Lock Mreset PWOFF PWSTA RS232zone Status Type Unlock Version VOUTMute x?$ x?avx1 Description Enable/Disable blinking of the front panel POWER LED Enable/Disable a comma adding a 5 second delay between commands Sets what command (set in the webgui) the front panel display button sends Displays the status for each input Displays IP address configuration Turns DHCP on / off Sets a static IP address Locks the buttons on the front panel Sets the unit back to default settings Execute this command to power-off the unit Execute this command to power-on the unit Displays the power state of the unit Use to trigger the ST31 to send the RS-232 command to the display connected to the HDBaseT receiver s RS-232 port. Displays the routing state of the unit Displays the model of the unit Unlocks the buttons on the front panel Displays the current firmware version of the unit Mutes/Unmutes audio output volume Mutes/Unmutes AV signals for the specified output channel Switch a specific input to the outputs AT-OME-SW32 3
Blink Enable/Disable blinking of the front panel POWER LED. Blink X X Value on, off, sta Blink on CommaWait Blink on Enable/Disable a comma adding a 5 second delay between commands. Default is on. CommaWait X X Value on, off, sta CommaWait on DispBtn CommaWait on Triggers the Display on/off command (set in the webgui) to be sent. Toggle will send the on or off depending on the last command sent. DispBtn X X Setting on, off, tog, sta DispBtn on InputStatus Displays the status for each input. DispBtn on InputStatus s InputStatus InputStatus 011 NOTE: The feedback will display channel status: 0 is no signal detected and 1 is signal detected. AT-OME-SW32 4
IPCFG Displays the current network settings for the unit. IPCFG IPCFG IPDHCP Turns DHCP on / off. Default is on. IP Addr 192.168.11.196 Netmask 255.255.255.0 Gateway 192.168.11.254 IP Port 23 IPDHCP X X Value on, off, sta IPDHCP on IPDHCP on IPStatic Sets a static IP address. IPStatic X Y Z X IP address 0 to 255 (per byte) Y Subnet mask 0 to 255 (per byte) Z Gateway (router) 0 to 255 (per byte) IPStatic 192.168.1.112 255.255.255.0 192.168.1.1 IPStatic 192.168.1.112 255.255.255.0 192.168.1.1 Lock Locks the front panel of the matrix so no buttons are active. Lock Lock Lock AT-OME-SW32 5
Mreset Sets matrix back to the default settings. MReset Mreset Mreset PWOFF Turns the unit off. Front panel LED will illuminate red when off. PWOFF PWOFF PWOFF Turns the unit on. Front panel LED will illuminate blue when on. PWSTA Displays the power status of the matrix. PWSTA PWSTA AT-OME-SW32 6
RS232zone Use to trigger the ST31 to send the RS-232 command to the display connected to the HDBaseT receiver s RS-232 port. RS232zone[X] X Command String RS232zone[VOL23] RS232zone[VOL23] Status Displays the current route status. Status X Status x3vx1, x1vx2 Type Brings up the model information. Type Type AT-OME-ST31 Unlock Unlocks the front panel of the matrix, enabling the buttons again. Unlock Unlock Unlock AT-OME-SW32 7
Version Brings up the current firmware version. Version Version 1.0.00 VOUTMute Mutes/unmutes the output audio channels. VOUTMuteX Y X Channel 1-2 Y Value on, off, sta VOUTMute1 sta VOUTMute1 on x?$ Mutes/Unmutes AV signals for the specified output channel. x?$ Y X Output 1-2 Y Variable on, off, sta x2$ sta x2$ on AT-OME-SW32 8
x?avx1 Switch audio and video input to output. x?avx1? Input 1-3 x1avx3 x1avx3 AT-OME-SW32 9
atlona.com 408.962.0515 877.536.3976 2018 Atlona Inc. All rights reserved. Atlona and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered trademarks are the property of their respective owners. Pricing, specifications and availability subject to change without notice. Actual products, product images, and online product images may vary from images shown here.