Installing the Cisco MDS 9020 Fabric Switch

Similar documents
Cisco MDS 9396S Multilayer Fabric Switch Hardware Installation Guide

Installing the Cisco UCS 6200 Series Fabric Interconnect

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Installing the Cisco SFS 3504 Server Switch

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco MDS 9132T 32-Gbps 32-Port Fibre Channel Switch Hardware Installation Guide

Installation and Maintenance

System Storage EXP3000 Rack Installation Instructions

Installing the IPS 4345 and IPS 4360

Rack Installation Instructions

Preparing to Install the VG248

N3240 Installation and Setup Instructions

Installation Job Aid for Ethernet Routing Switch 5900 Series

EXN4000 Storage Expansion Unit Installation and Setup Instructions

Installing and Managing the Switch

N3150 Installation and Setup Instructions

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Notes and Warnings for the Cisco UCS 5108 Server. The following notes and warnings apply to all installation tasks:

N3220 Installation and Setup Instructions

Power Supply and Fan Module Installation

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

LVN5200A-R2, rev. 1, Hardware Installation Guide

Installing the Cisco 2524 and Cisco 2525 Routers

Junos WebApp Secure 5.0 Hardware Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Dell SC7020 Storage Controller Getting Started Guide

Cisco ASR 1004 Router Overview and Installation

Installing Power Modules

Replacing the Power Supply

1 Getting Started Installing & Configuring

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

Installing the Cisco VG224 Voice Gateway

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

IBM Systems. Quick start guide for IBM System p5 505 ( )

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Arcserve UDP 8100 and UDP 8200

Power Supply Installation

Installing the Cisco AS5400XM Universal Gateway

Installing the Router

hp uninterruptible power system r12000 xr models installation instructions

Installing IDS Introducing IDS-4215 CHAPTER

Quantum DXi4700 Capacity Upgrade Guide

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

iconverter 2-Module Power Chassis

QFX10008 Switch Quick Start Guide

Switch Installation. Preparing. Safety Warnings CHAPTER

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide

System Storage DS3950 Quick Start Guide

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Dell OptiPlex All-in-One. Stand Installation Guide

120Ra-1 Pentium III Processor Installation Insert

IBM. Rack Installation Instructions

Dell Networking S4810 Open Networking (ON) Getting Started Guide

HARDWARE INSTALLATION GUIDE. Arcserve UDP 8100 and UDP 8200 Appliance Hardware Installation Guide

Rack Installation Instructions

Quick Installation Guide

Dell Networking S4100-ON Series. Set-Up Guide

E-Series Site Preparation Guide

Dell MD1280 Storage Enclosure Getting Started Guide

PIX 535. PIX 535 Product Overview CHAPTER

ProLiant ML350 Tower-to-Rack Conversion Guide. First Edition (September 2000) Part Number Compaq Computer Corporation

PIX 520. PIX 520 Product Overview CHAPTER

Installing the Cisco XR Router

N6000 Series Filer Installation and Setup Instructions

Managing Individual Components

S5048F-ON. Set-up Guide

actilib Library 2U Quick Start Guide

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Rack Installation Instructions

Installing and Removing SDRAM and DRAM

Installing the Cisco ASR 901 Mobile Wireless Router as a Satellite Shelf

Before you begin. Unpack & Prepare. Install Hardware. Connect Hardware. Apply Power. Choose Management Method. Install & Use SANtricity Software

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Rack Installation Instructions

InnoMedia Business VoIP ATA Models

Customer Replacement Procedure

Cisco UCS 6300 Series Fabric Interconnect Hardware Installation Guide

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Quick start guide for p5 520 ( )

Installing the ASA 5550

Installing a Network Module

Installing and Upgrading Memory and Virtual Private Network Modules

16Hi HARDWARE INSTALLATION GUIDE

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Dell Networking C9010 Getting Started Guide

Quick start guide for i5 520 ( or )

Customer Upgrade Procedure

1. Unpacking the System

S4112-ON Series. Setup Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell EMC Storage MD1280 Enclosure Owner's Manual

Switch Installation. Preparing for Installation. Safety Warnings

Transcription:

CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet or Rack, page 2-5 Grounding the Switch, page 2-9 Starting Up the Switch, page 2-9 Before you install, operate, or service the system, read the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family Switch for important safety information. Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 07 SAVE THESE INSTRUCTIONS Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 07 2-

Pre-Installation Chapter 2 Pre-Installation This section provides the following information: Installation Options, page 2-2 Installation Guidelines, page 2-2 Required Equipment, page 2-3 Unpacking and Inspecting the Switch, page 2-4 Installation Options The Cisco MDS 9020 Fabric can be installed using the following methods: In an open EIA rack, using: The rack-mount kit shipped with the switch The Telco and EIA Shelf Bracket Kit (an optional kit, purchased separately) in addition to the rack-mount kit shipped with the switch In a perforated or solid-walled EIA cabinet, using: The rack-mount kit shipped with the switch The Telco and EIA Shelf Bracket Kit (an optional kit, purchased separately) in addition to the rack-mount kit shipped with the switch In a two-post Telco rack, using: The Telco and EIA Shelf Bracket Kit (an optional kit, purchased separately) in addition to the front brackets shipped with the switch For instructions on installing the switch using the rack-mount kit shipped with the switch, see the Installing the Switch in a Cabinet or Rack section on page 2-5. For instructions on installing the switch using the optional, separately purchased rack-mount kit, see the Appendix A, Cabinet and Rack Installation. The rack-mount kit is optional and is not provided with the switch. To order the kit, contact your switch provider. Installation Guidelines Follow these guidelines when installing the Cisco MDS 9020 Fabric Switch: Plan your site configuration and prepare the site before installing the switch. Ensure there is adequate space around the switch to allow for servicing the switch and for adequate airflow (airflow requirements are listed in Appendix C, Technical Specifications ). Ensure the air-conditioning meets the heat dissipation requirements listed in Appendix C, Technical Specifications. Ensure the cabinet or rack meets the requirements listed in Appendix A, Cabinet and Rack Installation. 2-2

Chapter 2 Pre-Installation If the front cabinet mounting rails are not offset from the front door or bezel panel by a minimum of 3 inches (7.6 cm), and a minimum of 5 inches (2.7 cm) if cable management brackets are installed on the front of the chassis, the chassis should be mounted rear-facing to ensure the minimum bend radius for fiber optic cables. Jumper power cords are available for use in a cabinet. For more information, see the Jumper Power Cord section on page C-5. The switch is grounded through its power cord when connected to an AC power source. Furthermore, the switch is grounded to the rack through the rack-mount kit. No other grounding is required. Ensure the site power meets the power requirements listed in Appendix C, Technical Specifications. If available, you can use an uninterruptible power supply (UPS) to protect against power failures. Caution Avoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems such as the Cisco MDS 9020 Fabric, which can have substantial current draw fluctuations because of fluctuating data traffic patterns. Ensure that circuits are sized according to local and national codes. For North America, the 00 Watt power supplies require a 0A circuit. If you are using a 200/240 VAC power source in North America, the circuit must be protected by a two-pole circuit breaker. Caution To prevent loss of input power, ensure the total maximum loads on the circuits supplying power to the switch are within current ratings for wiring and breakers. Use the following screw torques when installing the switch: Captive screws: 4 in-lbs M3 screws: 4 in-lbs M4 screws: 2 in-lbs 0-32 screws: 20 in-lbs 2-24 screws: 30 in-lbs Required Equipment Gather the following tools before beginning the installation: No. Phillips screwdriver with torque capability 3/6-inch flat-blade screwdriver Tape measure and level ESD wrist strap or other grounding device Antistatic mat or antistatic foam 2-3

Pre-Installation Chapter 2 Unpacking and Inspecting the Switch Caution When handling switch components, wear an ESD strap and handle modules by the carrier edges only. An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be grounded either through the power cable, the chassis ground, or metal-to-metal contact with a grounded rack. Tip Keep the shipping container in case the chassis requires shipping in the future. If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/warp/public/687/directory/dirtac.shtm The switch is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, contact your customer representative immediately. To inspect the shipment, following these steps: Step Step 2 Compare the shipment to the equipment list provided by your customer service representative and verify that you have received all items, including the following: Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: Invoice number of shipper (see packing slip) Model and serial number of the damaged unit Description of damage Effect of damage on the installation 2-4

Chapter 2 Installing the Switch in a Cabinet or Rack Installing the Switch in a Cabinet or Rack This section describes how to install the Cisco MDS 9020 Fabric Switch. You can install the switch in a rack using the rack-mount brackets alone, or you can use the rack-mount kit. This rack-mount kit is optional and is not provided with the switch; to order the kit, contact your switch supplier. Required Equipment No. 2 Phillips screwdriver Tape measure and level (to ensure shelf brackets are level) Installing the Rack-Mount Brackets To mount the switch in a rack using just the rack-mount brackets, follow these steps: Step Step 2 Fasten the rack-mount brackets to the switch as shown in Figure 2-using two 0-32 screws on each bracket. Choose the bracket screw holes to produce the setback you want. Place the switch in the rack and fasten the bracket flanges to the rack with two 0-32 screws on each side. 2-5

Installing the Switch in a Cabinet or Rack Chapter 2 Figure 2- Installing the Rack-Mount Brackets 2 2 37644 Rack-mount brackets (2x) 2 0-32 screws (8x) Installing the Rack-Mount Kit Installing a switch in a rack or cabinet using the rack-mount kit involves installing switch slides on the switch and installing the shelf brackets in the rack or cabinet. Installing the Switch Slides Figure 2-2 shows the installation of the switch slides on the switch. The switch slides have several holes to allow you to mount the switch flush with the cabinet or with a setback. 2-6

Chapter 2 Installing the Switch in a Cabinet or Rack Figure 2-2 Installing the Switch Slides on the Switch 2 37655 Switch slides (2x), flush mount 2 0-32 screws (4x) To install the switch slides on the switch, follow these steps: Step Step 2 Position a switch slide on the switch to match the holes for a flush mount or a.25 inch setback. Attach with two 0-32 screws. Repeat with the other switch slide. 2-7

Installing the Switch in a Cabinet or Rack Chapter 2 Installing the Shelf Brackets Figure 2-3 shows the installation of the shelf brackets in a four-post EIA rack. Figure 2-3 Installing the Shelf Brackets in an EIA Rack 3 4 2 37653 Shelf brackets (2x) 3 0-32 screws (8x) 2 Slider brackets (2x) 4 Washers (8x) To install the shelf and slider bracket assemblies in the rack, follow these steps: Step Step 2 Extend the shelf bracket to fit the inner dimensions of the rack. The bracket flanges fit inside the rack. Be sure that the slider bracket is toward the front. Attach the flanges to the rack at each end with two screws through the upper and lower flange holes. If the rack holes are square, use a centering washer with each screw. 2-8

Chapter 2 Grounding the Switch Step 3 Step 4 Repeat steps and 2 with the other shelf bracket. Use a level to verify that the shelf brackets are at the same height. Grounding the Switch The switch is grounded through its power cord when connected to an AC power source. Furthermore, the switch is grounded to the rack through the rack-mount kit. No other grounding is required. Starting Up the Switch This section provides instructions for powering up the switch and verifying component installation. Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the switch. Do not connect the MGMT 0/00 Ethernet port to the LAN until the initial switch configuration has been performed. For instructions on configuring the switch, refer to the Cisco MDS 9020 Fabric Switch Configuration Guide and Command Reference. For instructions on connecting to this port, see the Connecting the Console Port section on page 3-2. To power up the switch and verify hardware operation, follow these steps: Step Plug the power cable into the switch and arrange the cable so that it cannot be accidentally pulled out. Depending on the outlet receptacle on your power distribution unit, you may need the optional jumper power cord to connect the Cisco MDS 9020 Fabric Switch to your outlet receptacle. See the Jumper Power Cord section on page C-5. Step 2 Step 3 Step 4 Step 5 Ensure that the power cables are connected to outlets that have the required AC power voltages (provided in the Power Specifications section on page C-2). Connect the other end of the power cables to an AC power source. The switch boots automatically. Listen for the fans; they should begin operating as soon as the switch is powered on. When the switch has finished booting, verify that the LED behavior is as follows: Input Power LED is green. Heartbeat LED is blinking once per second. If the Heartbeat LED is showing any other blink pattern, see Appendix B, Troubleshooting. The System Fault LED is off. The LEDs for the Fibre Channel ports remain off until the ports are connected to a device. 2-9

Starting Up the Switch Chapter 2 2-0