Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

Similar documents
Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

RXTP ROOM TEMPERATURE

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

EE160 - Humidity and Temperature Transmitter for HVAC Applications

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Carbon Monoxide Sensor - ModBus

RTD-W Installation Instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature

Operating Instructions Differential Pressure Transducer PS27

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

RТTH DUAL ROOM SWITCH

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Immersion Temperature Sensors

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Product data sheet accessories control and regulation Accessories AIRWIN

Control Head for the integrated mounting on process valves

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

CMC III Temperature/Humidity Sensor

Non-communicating room controllers

RTD-NET Installation Instructions

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

MU110-6U. Analog output module 6 channel. User guide

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Multi-range pressure and differential pressure transmitter

Operating instructions. Speed monitor D / / 2014

Temperature controller Ducted systems

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature General data

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

RS-FS-N01 Wind speed transmitter user's Guide (485type)

Temperature Controller

BMF400 Input/output module

CMC III Universal Sensor

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

lindab we simplify construction UltraLink Technical information

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

EE870 Modular CO 2 Transmitter

Operating instructions. Switching amplifier DN0210 DN / / 2015

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Digital electropneumatic Positioner for the integrated mounting on process control valves

EE671 - Miniature Air Flow Transmitter

Operating instructions. Standstill monitor A / / 2011

Electrical Actuators

About this Document 2 Symbols and Typographic Conventions... 2 Figures... 2 Downloading Manuals... 2

Neon pr. ph/ ORP measurement. Applications. Description

Installation manual plugs and connectors with screw connection (16/32 A)

Electrical Actuators

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Digital electropneumatic Positioner for the integrated mounting on process control valves

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

Level monitoring system NT 3500 Technical information / Instruction manual

Industrial motor controller for brushed DC motors 24 VDC

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Products. World Edition

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

Operation Manual SRZ Helical Flow Meters

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

TPM 80. Dew Point Transmitter. Manual. BA_TPM80_e // V1.0 // technical data are subject to change

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Room unit with PPS2 interface

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

InBin-P Pressure switches from 5 Pa Pa

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Digital electropneumatic positioner

Digital electropneumatic Positioner for the integrated mounting on process control valves

RS-FX-N01 wind transmitter user's Guide (485type)

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Transcription:

FTK RS485 Modbus Duct sensor for relative humidity and temperature Data Sheet Subject to technical alteration Issue date: 18052015 Application Duct humidity and temperature sensor for all HVAC duct applications Designed for control and monitoring applications Types Available FTK xxx RS485 Modbus Duct sensor xxx=140/270/400 mm with RS485 Modbus Interface Security Advice Caution The installation and assembly of the device should only be performed by authorized personnel The product should only be used for the intended application Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets Ensure all power is disconnected before installing Do not connect to live/operating equipment Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual Notes on Disposal As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable However, most Thermokon products contain valuable materials that should be recycled rather than disposed as domestic waste Please note the relevant regulations for local disposal Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 6960-0 fax: -400 wwwthermokoncom email@thermokonde

Page 2 / 5 Issue date: 18052015 Build-up of Self-Heating by Electrical Dissipative Power Temperature sensors with electronic components always have a dissipative power, which affects the temperature measurement of the ambient air The dissipation in active temperature sensors shows a linear increase with rising operating voltage This dissipative power has to be considered when measuring temperature In case of a fixed operating voltage (±0,2 V) this is normally done by adding or reducing a constant offset value As Thermokon transducers work with a variable operating voltage, only one operating voltage can be taken into consideration, for reasons of production engineering Transducers 010 V / 420 ma have a standard setting at an operating voltage of 24 V = That means, that at this voltage, the expected measuring error of the output signal will be the least For other operating voltages, the offset error will be increased or lowered by a changing power loss of the sensor electronics If a re-calibration should become necessary later directly on the sensor, this can be done by means of a trimming potentiometer on the sensor board Remark: Occurring draft leads to a better carrying-off of dissipative power at the sensor Thus temporally limited fluctuations might occur upon temperature measurement Application Notice for Humidity Sensors Refrain from touching the sensitive humidity sensor Any touch of it will result in an expiration of warranty Under normal environmental conditions we recommend a recalibration interval of about 1 year to maintain the indicated accuracy At high ambient temperatures and high humidity or when using the sensor in aggressive gases, an earlier recalibration or a change of the humidity sensor can become necessary Such recalibrations or a probable sensor change are not part of the general warranty Technical Data Measuring values Temperature, humidity Network technology RS485 Modbus (slave), Mode: RTU or ASCII, Baud rate: 9600, 19200 38400 or 57600, parity: no, even, odd, max 32 devices per bus segment, connection via twisted pair cable (120 Ohm), eg Li2YCY(TP) 2x2x022 or similar Power supply 1524 V = (±10%) or 24 V~ (±10%) Power consumption typ 0,7 W (24 V =) 1,8 VA (24 V ~) Measuring range temp -20+80 C (active) Scale range humidity 0100% rh non condensed Measuring range humidity 1090% rh Accuracy temperature ±1 C at 25 C Accuracy humidity typ ±2% at range 1090% rh (typ at 21 C) Enclosure PA6, pure white Protection IP65 (mounted) according to EN 60529 Cable entry Single entry M16 for cable max Ø=8 mm Connection electrical Terminal block max 15 mm² Pipe PA6, black, Ø=19 mm, mounting length 140, 270 or 400 mm Filter Stainless steel Ambient condition -20+70 C, max 85% rh non-condensed Weight: approx 170 g Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 6960-0 fax: -400 wwwthermokoncom email@thermokonde

Issue date: 18052015 Page 3 / 5 Terminal Connection Plan A1 Modbus B A2 Modbus A A3 GND A4 + 24 V = / 24 V ~ Device Address (binary coded) DIP 11 DIP 12 DIP 13 DIP 14 DIP 15 DIP 16 DIP 17 DIP 18 Address 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 Significance ON OFF OFF OFF OFF OFF OFF OFF 1 default OFF ON OFF OFF OFF OFF OFF OFF 2 ON ON OFF OFF OFF OFF OFF OFF 3 ON ON ON ON OFF OFF OFF OFF 15 ON ON ON OFF ON ON ON ON 247 Options DIP 21 Modus DIP 22 DIP 21 Baud DIP 24 DIP 2,5 Parity DIP 26 not used OFF RTU OFF OFF 9600 ON OFF even OFF ON ASCII ON OFF 19200 OFF ON Odd ON OFF ON 38400 OFF OFF No ON ON 57600 ON ON Not used When using ASCII mode, parity must be set to EVEN or ODD No Parity (no) is not available in ASCII mode RS485 Modbus Register Data adress Input register Function code Description Type 585dec 0x249hex 4 Relative humidity [1/10] % SIGNED 16 Bit 587dec 0x24Bhex 4 Temperature [1/100] C SIGNED 16 Bit Sample: rh = 01E2hex = 0482dec = 48,2% temp = 0B21hex = 2849dec = 28,49 C Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 6960-0 fax: -400 wwwthermokoncom email@thermokonde

Page 4 / 5 Issue date: 18052015 Mounting Advices The sensor can be mounted to the ventilation duct using a mounting flange (recommended) or directly Maximum air speed is 10 m/s Mounting without mounting flange (screwing sensor directly to the duct) Mounting with mounting flange (screwing mounting flange to the duct, fixing sensor to mounting flange) Dismounting Advices Unfix sensor and pull out vertically Do not tilt the sensor when pulling it out! Application Notice Due to air circulations, dirt and dust particles can be piled up in the course of time on the sintered filter, which is protecting the sensor Thus, the function of the sensor can be affected After having dismounted the filter, it can be air-cleaned with oil-free and filtered compressed air, super-clean air or nitrogen or by washing it out with distilled water If the filter is too dirty, it should be replaced Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 6960-0 fax: -400 wwwthermokoncom email@thermokonde

Issue date: 18052015 Page 5 / 5 Dimensions (mm) FTK 140 FTK 270 FTK 400 RS485 Modbus Length over all L1 185,5 / 315,5 / 445,5 mm Length sensor tube L2 140 / 270 / 400 mm Accessories (optional) Rawlplugs and screws (2 pcs Each) ArtNo 102209 Filter stainless steel, wire mesh (spare part) ArtNo 231169 Mounting flange MF19 (TPO) ArtNo 527705 Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 6960-0 fax: -400 wwwthermokoncom email@thermokonde