DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

Similar documents
DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

PROTECT Electronics Co. Ltd

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

High impedance protection relay

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

Residual overvoltage relay

Communication with EuroProt-IED Multifunctional intelligent devices

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Arc protection relay. Features Three-phase overcurrent function. Application

Synchro-check relay. Application

Arc protection relay. Features Three-phase overcurrent function. Application

MiCOM P220, P225 and P226C

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Feeder protection relay SPAA 341 C. Product Guide

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

Feeder protection relay

NPI800 NPI800R. First Handling Guide. Phase and earth overcurrent relay

Siprotec 7ST61 / 7ST63

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Protection Relays PHASE & RESIDUAL OVERCURRENT

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

TWO-WINDING TRANSFORMER DIFFERENTIAL

For Transmission, Distribution and Machinery protection.

TM221ME32TK controller M IO transistor PNP Ethernet

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

MiCOM P111. Three phase and earth fault overcurrent relays

TM241C40U controller M IO transistor NPN

TM221M16TG controller M IO transistor PNP spring

TM241C24T controller M IO transistor PNP

TM221M16R controller M IO relay

TM221M32TK controller M IO transistor PNP

TM241C40R controller M IO relay

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

MiCOM P122C Time-Overcurrent Protection

TM241CE24T controller M IO transistor PNP Ethernet

EARTH-FAULT AND SHORT-CIRCUIT INDICATOR TYPE EKL8001 / EKL8002 surface mounted

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

VIP 40/45 VIP 400/410

NPIH800 NPIH800R. First Handling Guide Earth overcurrent relay

TM241CE40R controller M IO relay Ethernet

This data sheet is only valid in association with the IL SYS INST UM E user manual.

RT4F-110V/25A RECTIFIER

RT4B-110V/12A RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

Bus Bar Protection Relay B-PRO 4000

TM221ME16T controller M IO transistor PNP Ethernet

UNITROL F Excitation systems for synchronous machines with and without rotating exciter

TM221CE40T controller M IO transistor PNP Ethernet

GRD130 - FEATURES APPLICATION

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

MID approval no. DE-08-MI004-PTB004 Date of release

02/11/2015

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

TM241CE24U controller M IO transistor NPN Ethernet

Feeder Protection Relay REF 610. Product Guide

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy

TU531, TU532 Terminal Unit

TM221ME16T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

TM241CEC24R controller M IO relay Ethernet CAN master

DC561, digital input/output module,

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New)

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL

Data communication and reporting unit

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

TM241CE24T controller M IO transistor PNP Ethernet

IC693PWR331 High Capacity Power Supply, 24 VDC Input

SPAA 341 C Feeder protection relay

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

RT12-240V/2.4kW Rectifier Specification

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

DSP-BASED MOTOR CONTROLLER FOR THREE-PHASE BRUSHLESS DC MOTORS

Relion 611 series. 611 series Type Test Certificate

ES Energy Saver Product Ranges 90Amp 6000Amp

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Overcurrent and Earth-Fault Relay REJ 525. Technical Reference Manual

DI561 Digital Input Module

TM221CE24R controller M IO relay Ethernet

Transcription:

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION Field of application The devices of the EuroProt complex protection family are modular devices. The modules are selected, assembled and configured according to the tasks to be performed. This information sheet describes one of the several possibilities: the DGBV-EP factory configuration. The general description concerning the EuroProt devices can be found in the document EuroProt complex protection, hardware and software description and user s manual, (further EuroProt manual ). The DGBV-EP factory configuration produced by PROTECTA Electronics Co. Ltd. is assembled to perform generator and generator-transformer unit protection. The experts of Protecta compile the complex system individually, fulfilling the special request of the users. The design is based on planning and designing experiences of several decades..

The main considerations of developing the DGBV-EP digital generator and generator-transformer unit protection are: Covering all protection and automation tasks in connection with the objects to be protected, Optimal assignment of protection function to the measuring transformers, Providing the necessary back-up protection functions, Fulfilling the individual and special requests of the user, Cost-optimised solution. Main characteristics Configuration of the complex protection: Independent racks in cabinet or cabinets, powered by independent power supply units, Individual EuroProt protection units in each racks, with dedicated connections to measuring transformers, Optimal functional assignment, Fully numerical signal processing in each functions, The individual functional units send commands and signals to the trip matrix located in independent unit, where, according to the setting, each signal of protection functions is directed to the appropriate interfering unit. The individual interactions can be disabled or enabled here, to support the commissioning, Signals and information can be received from auxiliary protective devices (gas protection, temperature protection), Continuous monitoring of CB circuits, Communication with each units in racks, LED signalling, display of numeric values and text messages, The individual racks are connected to fibre-optic loops, polled by monitoring and relay setting program, Digital event recorder, for monitoring the starting and trip commands of individual protection functions with 1 ms time resolution and for recording the measured analogous signals. The usual protection and automation functions are: Differential protection for the generator, for the transformer, for the auxiliary transformer and for the whole unit, Overcurrent protection, Field failure protection, Under-impedance protections, Definite time or IDMT overload and overcurrent protection, Unbalanced load (negative phase sequence) protection, over voltage protection, Reverse power protection, Stator earth fault protection, Rotor earth fault protection, Multi-stage under/over frequency protection, Automatic synchroniser.

Hardware characteristics of individual devices: Fully numerical type, with individual A/D converters, digital signal processors (DSP) and separate main processor, Optical-coupler inputs, Output contacts, type of output contacts (NC, NO) can be defined at design time, Design for 19" rack cabinets. Communication: Relay setting with 2x16 character LCD display, suitable also for text messages and for event log display, On-line screen of a connected PC to support of commissioning, Auxiliary communication connection selectable for RS 232 or fibre optic cable, Optional SCADA connection with IEC 870 protocol, Parameters can be saved and saved parameters can be downloaded again, Real-time clock with battery-fed RAM, (which can be synchronised via fibreoptic connection by auxiliary PC, by the SCADA system, or via opto-coupler digital input). Working principles The EuroProt devices are microprocessor-based systems, the functions and their versions are realised by software. The man-machine communication is performed by a six button-keypad on the front plate, the 2x 16 characters LCD display above them, with seven signal LED-s and with two SW pushbuttons. With external PC and with the handling software the device can be set, checked and monitored more easily. To display the rows and columns of the trip matrix and for other important signalling a large LCD display is provided, containing further LED-s. The analog current ad voltage inputs are connected to the multiplexer and further to the A/D converter via intermediate measuring transformers, where the sampling time is 0,5 ms for each current and voltage signal. The sampled digital values of the 16 bit A/D converter are transported to the CPU via high-speed serial bus by the CAN controller. The digital signal processor performs arithmetic operation with high speed. The output of the DSP is the evaluated result of the measurements; these signals are directed as "relay started" signals to the central processor. The central processor performs logic function and time delay measurements. The optocoupler inputs and relay outputs communicate with the central processor via parallel bus. The detailed information of the individual protection functions are described in different information sheets.

Basic technical data of individual devices Rated secondary current, I n 1A or 5 A Rated secondary voltage (line-to-line), U n 100 V or 200 V Rated frequency 50 Hz or 60 Hz Overload capacity, voltage circuit, thermal, continuous 2xU n / 3 current circuit, thermal, continuous 1 s 4xI n 100xI n (if I n = 1 A) 50xI n (if I n = 5 A) Dynamic current limit 100xI n Accuracy of digital impedance protection functions ± 5% (above 50% In) Accuracy of digital current protection functions (above ± 2% 50% In) Accuracy of timers, with 10 ms steps with 1 s steps ± 3 ms ± 12 ms Resetting ratio of current relays 95% Output relay contacts to be specified at projecting Type of output contacts (NO/NC): Output contacts, electrical data: rated switching voltage continuous load current making current DC breaking capability at 220 V, at pure conductive load at load of L/R = 40 ms Optionally, at load of L/R = 40 ms Auxiliary DC voltage (the same supply unit) voltage tolerance Permissible ambient temperature Insulation test (IEC 255) to be specified at projecting 250 V 8 A 16 A 0,25 A 0,14 A 4 A 220 V or 110 V 88...310 V 0...50 C 2 kv, 50 Hz 5 kv, 1,2/50 µs Disturbance test (IEC 255) 2,5 kv, 1 MHz Electrostatic discharge (ESD) 8 kv (IEC 801-2) Burst test 2 kv (IEC 801-4)

Design, size The DGBV-EP complex protection equipment is delivered in a steel-sheet cabinet with standard 19 hinged rack system and locked door, accessible from the front side. When selecting the cabinet type the manufacturer can consider the special requirements of the user. If not specified at ordering, the cabinet is of RITTAL PS type. Options As option the device can be fitted with the following units: Digital disturbance recorder (see separate information sheet), SCADA connection (see EuroProt system information sheet), Relay contacts with 4 A breaking capability, Output circuit supervision in each phases. Ordering information When ordering, the experts of PROTECTA are ready for consultation and for the necessary engineering activity.