Configuring and Using Redundant Disks with Cisco MCS

Similar documents
CallManager Configuration Requirements for IPCC

Fixing Issues with Corporate Directory Lookup from the Cisco IP Phone

Reestablishing a Broken CallManager Cluster SQL Subscription with Cisco CallManager

Cisco MCS-78XX Boot Error Codes

Reestablishing a Broken Cisco CallManager Cluster SQL Subscription with CallManager 3.0, 3.1 and 3.2

Hotdial on IP Phones with CallManager Configuration Example

MeetingPlace for Outlook Onsite Installation or Upgrade

CallManager MoH uses G.711 Codec while Voice Calls use G.729 Codec Configuration Example

Cisco Aironet Client Adapter Installation Tips for Windows NT v4.0

Low Profile SATA RAID 2 Port PCI Host

The term "physical drive" refers to a single hard disk module. Figure 1. Physical Drive

UTC3100 and 3170 POS RAID Information

Sharing a Cisco Unity Voice Mail Box between Two or More IP Phones

IP Phone 7940/7960 Fails to BootProtocol Application Invalid

AMD RAID Installation Guide

Install Windows 2000 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters

CDR Database Copy or Migration to Another Server

Storage Profiles. Storage Profiles. Storage Profiles, page 12

QuickSpecs. Compaq Smart Array 431 Controller M ODELS

RAID SATA II 3Gbps 4 Ports PCI-X Host

Setting up Inter Cluster Trunks with Three or More Cisco CallManagers

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Active Directory 2000 Plugin Installation for Cisco CallManager

Physical Memory Recommendations for Cisco CallManager Version 4.0 and later

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller.

Troubleshooting Server Disk Drive Detection and Monitoring

Server Systems and Motherboards

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1

CTC Fails to Start on Windows XP with Cisco Security Agent

Guide to SATA Hard Disks Installation and RAID Configuration

Configuring Cisco CallManager IP Phones to Work With IP Phone Agent

RAID5 SATA II Host Adapter

Configuring Storage Profiles

Expanding an ICM SQL Database

Securing LDAP Directory Integration with Cisco Unified CallManager 4.x

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

QuickSpecs. Models. Overview

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

RAID Levels Table RAID LEVEL DESCRIPTION EXAMPLE

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

QuickSpecs. Models. Overview

RAID Native SATA Ports PCI Host

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

If the WD Security icon was not chosen to be placed on the desktop, please follow the steps below, to open from the Program Files List.

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

The system is temporarily unable to complete your call. Event Type: Error Event Source: CiscoUnity_ConvMsg Event Category: Network Event ID: 10045

NVIDIA RAID Installation Guide

HP Smart Array P700m Controller for HP ProLiant Servers User Guide

Cisco Unified IP Phone 7942/7945/7962/7965/7975 Firmware Upgrade from pre 8.3(3) to 9.3(1)

Dell PowerEdge RAID Controller S140 - PERC S140. User s Guide

Guide to SATA Hard Disks Installation and RAID Configuration

RocketU 1144CM Host Controller

Tune the CTC HEAP Variables on the PC to Improve CTC Performance

Dell PowerVault DL Backup to Disk Appliance and. Storage Provisioning Option

DocSTAR Mini RAID Internal Subsystem Technical Documentation

HP Supporting the HP ProLiant Storage Server Product Family.

VG248 Port Configuration to Light the Caller ID MWI

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2

CMD Medley ATA RAID SOFTWARE User s Manual June 10, 2001 Revision 1.0

NVIDIA / JMicron RAID Installation Guide

Compaq ProLiant ML330 Generation 2. Service Overview. White Paper

RAID User Guide. Edition. Trademarks V1.0 P/N: U25-A2-0E

Controller PCI Card MODEL MAN UM

Taurus Super-S Combo

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

NEC Express5800 Series

Data rate - The data rate is the number of bytes per second that the drive can deliver to the CPU.

CASPER SECURE SERVER EDITION 3.0 USER GUIDE

Guide to SATA Hard Disks Installation and RAID Configuration

Managing Blade Servers

INDeX Technical Tip. Tip No: 234 Release Date: 20 August 2004 Region: EMEA & APAC. EVM Raid Information. Overview. RAID 5 Stripe Set with Parity

MSA Event Descriptions Reference Guide

ReadyNAS OS 6 Desktop Storage Systems

NVIDIA RAID Installation Guide

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

FASTTRAK S150 TX4 USER MANUAL. Version 1.5M

Marvell SATA3 RAID Installation Guide

UCS Uplink Ethernet Connection Configuration Example

RAID Configuration. Workstation W60 Rev5

Taurus S2. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English )

Lab - Manage Virtual Memory in Windows 7 and Vista

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Dell Storage MD1400 Enclosures Hardware Owner's Manual

AMD RAID Installation Guide

AssuredSAN Event Descriptions Reference Guide

BizNAS D400/R400 series Online User Guide

AssuredSAN Pro 5000 Series Events Reference Guide

Technical Guide Network Video Recorder Enterprise Edition Maintenance Guide

Product Release Notes

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

QuickSpecs. What's New. Models. Overview

Troubleshoot Missing Speed Dials Issue in IPMA

SATARaid Serial ATA RAID Management Software

NEC PowerMate VT 300 Series Release Notes

Check Password Synchronization with the Admin Utility in the Cisco CallManager Cluster

HP HP/Windows 2000 Integration and Performance. Download Full Version :

Taurus Mini Super-S LCM

Transcription:

Configuring and Using Redundant Disks with Cisco MCS Document ID: 9229 Contents Introduction Prerequisites Requirements Components Used Conventions Drive Mirroring (RAID 1) Recognize a Drive Failure Recover from Drive Failure Replace a Failed Drive Recover from Upgrade Failure on Cisco CallManager Related Information Introduction This document answers some of the primary questions about disk redundancy on the Cisco Media Convergence Server (MCS). In addition, the document describes how to get the most out of the redundant disk technology (Redundant Array of Independent Disks [RAID]) that comes with the MCS. Prerequisites Requirements Cisco recommends that you have basic hardware knowledge. Components Used The information in this document is based on these software and hardware versions: MCS 7830 MCS 7835 Note: The Cisco CallManager OS images have been created for specific fixed hardware configurations on specific platforms. If you need to increase the hard disk space or performance, you must take a backup. Complete these steps: 1. Upgrade the server platform. 2. Reinstall Cisco CallManager. 3. Use the Backup and Restore System (BARS) in order to restore. You must perform these steps in order to use the same platform/server and increase the hard disk space. For more information about Cisco CallManager hardware, refer to Cisco 7800 Series Media Convergence Servers Product Brochures.

The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command. Conventions Refer to Cisco Technical Tips Conventions for more information on document conventions. Drive Mirroring (RAID 1) The default Cisco CallManager OS image install installs the MCS with a RAID 1 configuration. Drive mirroring, which is also called RAID 1, is the highest performance and highest fault tolerance RAID method. RAID 1 is the only option that offers fault tolerance protection if only two drives are installed or selected for an array. In order to create fault tolerance, drive mirroring stores two sets of duplicate data on a pair of disk drives. RAID 1 is the most expensive fault tolerance method because 50 percent of the drive capacity is used to store the redundant data. RAID 1 always requires an even number of disks. The data is striped across the drives, and then mirrored. If a drive fails, the mirror drive provides a backup copy of the files, and there is no interruption of normal system operations. The mirroring feature requires a minimum of two drives. By default, the MCS 7830 and MCS 7835 are delivered with two disks that are configured with RAID 1. Therefore, recovery from a single drive failure is possible. This diagram shows the stripe of the data in chunks in order to provide a mirror. Data chunk A on one disk is mirrored to A on another disk, data chunk B is mirrored to B on another disk, and so on. In other words, the data is striped in chunks and then copied (mirrored) to the second disk. If the first disk that holds data A fails, you can still read/write from the other disk that contains data A: In order to find out how your disks have been configured, perform one of these two procedures: 1. Use the Array Configuration Utility from the SmartStart and Support Software CD. a. Insert the SmartStart and Support Software CD in the CD drive and power up the server. A menu displays. b. Choose Array Configuration Utility. c. After completion, remove the CD and restart the server. 2. Use the Compaq Array Configuration Tool. a. Choose Start > Programs > Compaq System Tools > Compaq Array Configuration Tool. This window pops up:

b. This disk has one logical disk space area of 8673 MB. Click the Physical disk image. You can see that there are two physical disks present, each of 9.1 GB. Because these disks are mirrored, you only see one logical drive of 8673 MB on the logical tab. Recognize a Drive Failure A system operator can recognize a drive failure in one of several ways: The amber LED is illuminated on failed drives in a hot pluggable tray. However, the illumination only occurs if the storage system is turned on and the Small Computer System Interface (SCSI) cable works. Note: The amber LED can be illuminated briefly when you insert a hot pluggable drive. This behavior is normal. A power on self test (POST) message lists failed drives whenever you restart the system. But the message displays only if the controller detects one or more "good" drives.

Drive Array Advanced Diagnostics (DAAD) lists all failed drives. An online version of DAAD is also available in Microsoft Windows NT and Windows 2000 environments. Compaq Insight Manager can detect failed drives remotely across a network. A drive failure also shows up on the Array Configuration Utility. Assume, for example, that you pull disk 1 (ID 1) out of the array or that the disk is broken. The array controller discovers that one of the disks has failed or is missing. However, the system is still up and running. Logical drive 1 still operates because RAID 1 can survive a disk failure. But the drive operates with reduced performance.

The Physical Configuration View of the array shows that disk 1 (ID 1) has failed. A drive failure can also show this error message in the event log: Event Type: Error Event Source: cpqcissm Event Category: None Event ID: 9 Description: The device, \Device\Scsi\cpqcissm1, did not respond within the timeout period. Recover from Drive Failure The Smart Array 221 Controller with use of the MCS 7830 supports hot pluggable drives. You can install or remove these drives without the need to turn off the system power. You can remove and replace failed drives in hot pluggable trays while the host system and storage system power are both ON. If you insert the drive while the power is ON in fault tolerant configurations, the recovery of data on the replacement drive automatically begins. A blinking online LED indicates that this data recovery has begun.

In some situations, you remove disk 1 (ID 1) from the array, either because the disk has failed or because it was taken out before an upgrade. Then, you insert the disk back into the array. Or, you may insert a new disk because the previous disk was faulty. In these cases, the disk is automatically overwritten with the information on the original disk that was in the array. In this document example, that disk is disk 0, ID 0. In general, approximately 15 minutes per GB is necessary for a rebuild. However, the actual rebuild time depends on these factors: The Rebuild Priority set The amount of I/O activity that occurs during the rebuild operation The number of drives in the array The disk drive speed Caution: Never insert a disk if you do not want it to be overwritten by the original disk. Replace a Failed Drive These steps illustrate the automatic process that replaces a failed drive. 1. Disk 1, ID 1 is put back into the array and the process to rebuild the logical drive is underway. 2. In the Logical Configuration View, you can see that the array icon is no longer broken and the rebuild occurs.

3. In the Physical Configuration View, you can now see two disks again because disk 1, ID 1 reappears during the rebuild. 4. The array is now rebuilt and the Status appears as OK.

Recover from Upgrade Failure on Cisco CallManager You can also replace hot pluggable drives when the power is OFF. At the insertion of a hot pluggable drive, all disk activity on the controller temporarily pauses while the drive spins up. This process usually takes about 20 seconds. Assume, for example, that you are about to do an upgrade on your Cisco CallManager system. As a precaution, you take disk 1, ID 1 out of the array. You perform the upgrade on disk 0, ID 0. The upgrade fails. This procedure outlines the steps to take in order to go back to the original configuration (disk 1). 1. Bring the server down. 2. Take disk 0, ID 0 out of the server. 3. Insert disk 1, ID 1 with the good configuration into the array. 4. Boot the server with this disk. 5. At the bootup window, press F2: "Interim Recovery mode will be enabled if configured for fault tolerance". Note: Always place the disk in the slot from which you have removed the disk. These steps describe the process in detail: 1. After you boot with disk 1, ID 1, the system notices that the original drive (disk 0, ID 0) has failed.

2. In the Physical Configuration View, disk 0, ID 0 is no longer present and the array icon is broken. After you replace disk 0, ID 0, the array begins to rebuild. If the disk does not start to rebuild, remove the disk from the drive cage and insert it again.

3. In the Logical Configuration View, the array icon is no longer broken. 4. In the Physical Configuration View, the disk with the bad configuration (disk 0, ID 0) is now present again.

The capacity of replacement drives must be at least as large as the capacity of the other drives in the array. The controller immediately fails drives that have insufficient capacity and does not start the Automatic Data Recovery. If the Smart Array 221 Controller has a failed drive, replace the drive with a new or known good replacement drive. In some cases, a drive that the controller has previously failed can appear to be operational after the system is power cycled or after removal and reinsertion of a hot pluggable drive. Caution: This practice is highly discouraged because the use of such "marginal" drives can eventually result in data loss. Related Information Voice Technology Support Voice and Unified Communications Product Support Troubleshooting Cisco IP Telephony Technical Support & Documentation Cisco Systems Contacts & Feedback Help Site Map 2014 2015 Cisco Systems, Inc. All rights reserved. Terms & Conditions Privacy Statement Cookie Policy Trademarks of Cisco Systems, Inc. Updated: Jan 31, 2006 Document ID: 9229