Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

Similar documents
Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

Typical Efficiency (2) 0 ~ 12.5 A 150 W 90.0% EUV-150S012DTA(STA) 0 ~ 6.25 A 150 W 90.5% EUV-150S024DTA(STA) (4)

Typical Efficiency (2) 500 ma 90 ~ 305 Vac 32~64 Vdc 32 W 87.0% EUC-035S070SVM0004

Output Voltage Range. Max. Output Power

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~250 Vdc. Leakage Current ma IEC ; 240Vac/ 60Hz

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~250 Vdc

Typical Efficiency (2) Max. Output Power. 700 ma 160~305 Vac 30~60 Vdc 42 W 88% 0.95 EBC-042S105DV(SV)-0007

Typical Efficiency (2) Max. Output Power. 700 ma 140 ~ 305 Vac 107 ~ 214 Vdc 150 W 92.0% 0.96 EDC-150S105SV-0007

Typical Efficiency (2) Max. Output Power ma 176 ~ 305 Vac 260~400Vdc 420 W 94.0% 0.95 EBC-420S105DV(SV)

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 97~214 Vdc 150 W 93.0% 0.98 EBD-150S105DVA

Output Voltage Range. Max. Output Power ma ma 700 ma 176~305 Vac 43~107 Vdc 75 W 90.5% 0.98 EBD-075S105DV

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 155~343 Vdc 240 W 94.0% 0.98 EBD-240S105DV

Max. Output Power. Typical Efficiency (1) 12 Vdc 249~ 528 Vac 0~10 A 120 W 91.5% ESV-150S012ST

Output Voltage Range. Parameter Min. Typ. Max. Notes. Leakage Current ma IEC ; 240Vac/ 60Hz

Max. Output Power. Typical Efficiency (2) 143~286Vdc 200 W 93.5% EUD-200S070GV. 95~190Vdc 200 W 93.5%

Output Voltage Range. Max. Output Power

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST) (3 ) Parameter Min. Typ. Max. Notes

Output Voltage Range. Max. Output Power

Feature Ultra High Efficiency (Up to 94%)

Output Voltage Range. Max. Output Power. (4) 90~305 Vac 127~300 Vdc 8 ~54 Vdc 40 W 89.5% LUD-040S150BSF

HEC-100RTN-48QSCA Rev A1.0

Output Voltage Range. Max. Output Power. (4) 90~305 Vac 127~300 Vdc 16~78 Vdc 60 W 90% LUD-060S110BS2

H HOLUX Kft. H-1135 Budapest, Béke u Tel: (06 1) Fax: (06 1)

240W Six-channel Constant Current IP67 Driver

Power Factor Model Number Voltage Voltage

Max. Output Power. Typical Efficiency (1) 350 ma 90 ~ 305 Vac 107~214Vdc 75 W 92% EUC-075S035DT(3)

Efficiency (1) 110Vac 220Vac

Efficiency (1) 110Vac 220Vac

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

Constant Voltage Mode

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Safety Standards. Model Number: Unit Weight:

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS

Safety Standards. Model Number:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Safety Standards. Model Number:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Output Voltage in Constant Voltage Mode. Model Number

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

IEC/EN/UL60950 & CE certified, EN55032 Class B

Safety Standards. Model Number:

Features. Applications and Benefits TRC ELECTRONICS, INC

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

SAMSUNG ELECTRO-MECHANICS CO., LTD

Safety Standards. Model Number:

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Universal input VAC <150mW No load power consumption

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Safety Standards. Model Number:

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Safety Standards. Model Number:

Gelo LED Driver 100W, Single output RGLD100-24

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

LNE. LED Driver LNE-185W Series / LNE- V185W. Highlights & Features. Safety Standards. Model Number: General Description

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Safety Standards. Model Number:

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Inventronics LED Driver 0 10V DMX RDM

60 Watt Medical (MWLT)

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

030AAC Highlights & Features

Universal Power Supplies

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

LNV. Safety Standards. Model Number:

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

OLU750P701N1A PSOV750701*(N)

Features. LED Driver. RCOB Constant Current Active PFC Single Output. AC/DC Converter

Enclosed Power Supplies

LNE. LED Driver LNE-100W Series / LNE- V100W. Highlights & Features. Safety Standards. Model Number: General Description

Transcription:

Features High Efficiency (up to 93.5%) Constant Voltage Output Input Surge Protection: 4kV lineline, 6kV lineearth AllAround Protection: OCP, OVP, SCP, OTP Waterproof (IP67) SELV Output Independent Design 5 Years Warranty Description The EBV250SxxxSV series is a 250W, constantvoltage IP67 LED driver that operates from 176305 Vac input with excellent power factor. It is created for many lighting applications including architectural, decorative and signage. The high efficiency of the driver and compact metal case enables them to run cooler, significantly improving reliability and extending product life. To ensure troublefree operation, protection is provided against input surge, over current, output over voltage, short circuit, and over temperature. Models Output Voltage 12 V 24 V 36 V 48 V Input Voltage Range(1) 176 ~ 305 Vac 190 ~ 250 Vdc 176 ~ 305 Vac 190 ~ 250 Vdc 176 ~ 305 Vac 190 ~ 250 Vdc 176 ~ 305 Vac 190 ~ 250 Vdc Output Current Range Max. Output Power(2) Typical Efficiency (3) Power Factor 220Vac Model Number(4)(5) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV250S024SV 0 ~ 7.0 A 250 W 92.5% 0.96 EBV250S036SV 0 ~ 5.3 A 250 W 93.5% 0.96 EBV250S048SV Notes: (1) CCC certified input voltage range: 220/230/240 Vac; other certified input voltage range except CCC: 200240 Vac or 190250Vdc (except KS and BIS). (2) Operating input voltage range: 90305Vac, and 90176Vac is for safety operation (see below Derating curve for details) (3) Measured at 100% load and 220Vac input (see below General Specifications for details). (4) SELV output. (5) For BIS models add suffix 3000. Input Specifications Parameter Min. Typ. Max. Notes Input Voltage 176 Vac 305 Vac 190250 Vdc Input Frequency 47 Hz 63 Hz Leakage Current 0.70 ma IEC605981; 240Vac/60Hz Input AC Current 1.38 A Measured at 100% load and 220Vac input. 1 / 10

Input Specifications (Continued) Parameter Min. Typ. Max. Notes Inrush Current(I 2 t) 2.22 A 2 s PF 0.9 THD 20% THD 10% At 220Vac input, 25 C cold start, duration=808 μs, 10%Ipk10%Ipk. See Inrush Current Waveform for the details. At 220240Vac, 5060Hz, 60% 100%load(150250W) At 220240Vac, 5060Hz, 75% 100%load(187.5~250W) Output Specifications Parameter Min. Typ. Max. Notes Output Voltage Tolerance 2.5% 2.5% At 100% load condition Total Output Voltage Ripple (pkpk) Startup Overshoot/ Undershoot 2%Vo Measured at 220240Vac input, 0% 100% load condition. Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 μf ceramic capacitor and a 10 μf electrolytic capacitor. 5%Vo At 100% load condition Line Regulation ±0.5% Measured at 100% load Load Regulation ±1% Turnon Delay Time 0.5 s Measured at 220Vac input, 100% load Load Dynamic Response Output Deviation 5%VO Settling Time 10 ms R/S: 1 A/μs Load: 25% ~ 100% load. Temperature Coefficient of Vo 0.03%/ C Case temperature = 0 C ~Tc max Note: All specifications are typical at 25 C unless otherwise stated. General Specifications Parameter Min. Typ. Max. Notes Efficiency at 220Vac input: EBV250S012SV EBV250S024SV EBV250S036SV EBV250S048SV 89.5% 91.0% 90.5% 91.5% MTBF Lifetime Operating Case Temperature for Safety Tc_s 91.5% 93.0% 92.5% 93.5% 389,000 Hours 96,000 Hours 40 C +90 C Measured at 100% load and steadystate temperature in 25 C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.) Measured at 220Vac input, 80%Load and 25 C ambient temperature (MILHDBK 217F) Measured at 220Vac input, 80%Load and 70 C case temperature; See lifetime vs. Tc curve for the details 2 / 10

General Specifications (Continued) Parameter Min. Typ. Max. Notes Operating Case Temperature for Warranty Tc_w 40 C +75 C Case temperature for 5 years warranty. Humidity: 10% RH to 100% RH. Storage Temperature 40 C +85 C Humidity: 5%RH to 100%RH Dimensions Inches (L W H) Millimeters (L W H) 6.5 x 2.66 x 1.56 165 x 67.5 x 39.7 With mounting ear 7.48 2.66 x 1.56 190 67.5 x 39.7 Net Weight 900 g Note: All specifications are typical at 25 C unless otherwise stated. Safety & EMC Compliance Safety Category Standard CE & ENEC EN 613471, EN61347213 CB IEC 613471, IEC 61347213 CCC GB 19510.1, GB 19510.14 BIS IS 15885(PART2/SEC13) KS KS C 7655 EMI Standards EN 55015 (1) EN 6100032 EN 6100033 EMS Standards EN 6100042 EN 6100043 EN 6100044 EN 6100045 EN 6100046 EN 6100048 EN 61000411 EN 61547 Notes Conducted emission Test &Radiated emission Test Harmonic current emissions Voltage fluctuations & flicker Notes Electrostatic Discharge (ESD): 8 kv air discharge, 4 kv contact discharge RadioFrequency Electromagnetic Field Susceptibility TestRS Electrical Fast Transient / BurstEFT Surge Immunity Test: AC Power Line: line to line 4 kv, line to earth 6 kv Conducted Radio Frequency Disturbances TestCS Power Frequency Magnetic Field Test Voltage Dips Electromagnetic Immunity Requirements Applies To Lighting Equipment Note: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that contains it depends also on the other devices connected to the driver and on the fixture itself. 3 / 10

Derating Lifetime vs. Case Temperature 4 / 10

Inrush Current Waveform Efficiency vs. Load EBV250S012SV EBV250S024SV EBV250S036SV EBV250S048SV 5 / 10

Power Factor Total Harmonic Distortion Protection Functions Parameter Notes Over Current Protection Over Voltage Protection Short Circuit Protection Over Temperature Protection Auto Recovery. The driver shall be selfrecovery when the fault condition is removed. Limits output voltage at no load and in case the normal voltage limit fails. Auto Recovery. No damage will occur when any output is short circuited. The output shall return to normal when the fault condition is removed. Auto Recovery. Returning to normal after over temperature is removed. 6 / 10

Mechanical Outline EBV250S012SV INPUT VDE H05RNF 3C*1.0mm 2 7.2) OUTPUT (VDE H07RNF 2C*1.5mm 2 9.4) AC/L(BROWN) AC/N (BLUE) GND(YELLOW/GREEN) V+(BROWN) V (BLUE) V+(BROWN) V (BLUE) PROJ: Unspecified tolerance:±1 Note: The 2 DC output cables are connected in parallel internally because one 1.5mm 2 wire can only carry 14.5A. Please connect the 2 brown wires together and 2 blue wires together in application, or ensure each cable carries same current. 7 / 10

EBV250S024SV INPUT VDE H05RNF 3C*1.0mm 2 7.2) OUTPUT (VDE H07RNF 2C*1.5mm 2 9.4) AC/L(BROWN) AC/N (BLUE) GND(YELLOW/GREEN) V+(BROWN) V (BLUE) PROJ: Unspecified tolerance:±1 EBV250S036/048SV INPUT (VDE H05RNF 3C*1.0mm 2 7.2) OUTPUT (VDE H05RNF 2C*1.0mm 2 6.8) AC/L(BROWN) AC/N (BLUE) GND(YELLOW/GREEN) V+(BROWN) V (BLUE) PROJ: Unspecified tolerance:±1 8 / 10

RoHS Compliance Our products comply with the European Directive 2011/65/EU, calling for the elimination of lead and other hazardous substances from electronic products. 9 / 10

Revision History Change Date Rev. Description of Change Item From To 20181214 A Datasheet Release / / 10 / 10