INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Similar documents
INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D

INSTRUCTION & SAFETY MANUAL

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D.

DeltaV Bulk Power Supplies

INSTRUCTION MANUAL. Analog Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1052S, D1052D, D1052X, D1052Y D1052S - D1052D

DeltaV Bulk Power Supplies

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 12/2007

Operating Instructions

Zener Barriers Bulletin 937Z

PHOENIX CONTACT - 05/2007

MINI-PS AC/10-15DC/8

FLEX Ex Spring Clamp Terminal Base

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

INSTRUCTION & SAFETY MANUAL

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

INSTRUCTION & SAFETY MANUAL

PanelView Plus/VersaView CE Terminals and Display Modules

QUINT-BUFFER/24DC/24DC/40

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

ETD-BL-1T-OFF-CC- 10S

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

The Solid-State Decoupler (SSD)

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Switched Mode Power Supply Operating manual PAP800

Redundancy Module QUINT-DIODE/40

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Redundancy unit CP-A RU

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Power supply CP-C 24/5.0

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

RTU500 series Data Sheet Power Supply CP-E 24/2.5

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS


MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

SITOP in the SIMATIC Design

XPSMCMDI Input expansion module with screw term

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Discrete Output Modules

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MACX MCR-EX-SD LP(-SP)

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

MINI MCR-SL-PT100-UI(-SP)(-NC)

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Power Supply HARTING pcon

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Line Impedance Stabilization Network (LISN)

RSTI-EP Slice I/O. Digital Output Module

MANUAL Surge Protectors

QUINT-PS-3x AC/24DC/10

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

XPSMCMDO Digital output pairs expansion modules with screw term

MINI MCR-SL-CVS NC

Rotork Fairchild PAX1 Linear Actuator User s Manual

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Installation & Operation Manual

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Power Supply HARTING pcon

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

SolConeX extra-low voltage flange socket

PHOENIX CONTACT - 07/2006

DR7100 SERIES Supplementary instructions

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Transcription:

PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

Characteristics General Description: The PSD1000 is a DIN Rail mounting universal AC input switching power supply with 24 Vdc 500 ma current output capability, to supply D1000 Series units or other 24 Vdc devices; it provides isolation between input and output and for model PSD1000F a relay for detection of supply fault (input line, output overload or thermal overload). The output is protected from overload (current or thermal) and short circuit (the unit switches the output off for a second and then tries to re-activate it until the fault condition is removed). The output is diode protected to connect multiple power supplies (redundant output) or to increase the output power. Function: Universal input power supply to drive D1000 Series units or other field equipment, provides 3 port isolation (supply/output/fault). Signalling LED: Power supply indication (green). EMC: Fully compliant with CE marking applicable requirements. Technical Data: Supply: 115-230 Vac, 50-60 Hz nom (95 to 264 Vac, 48 to 400 Hz) or 115 to 350 Vdc, ripple within voltage limits 10 Vpp. Limit supply voltage to 250 Vrms for Intrinsic Safety applications. Current consumption @ 115 Vac: 220 ma with 500 ma output current.. Current consumption @ 230 Vac: 150 ma with 500 ma output current.. Efficiency: 80 % at 115 Vac input, 82 % at 230 Vac input. Inrush current: 10 A with 10 ms duration. Max. power consumption: 15 W with full output, 1W with no load, max. internal power dissipation 3 W. Isolation (Test Voltage): AC Input/DC Output 2.5 KV; AC Input/Fault Output 2.5 KV; DC Output/Fault Output 500 V (PSD1000F only). Output: 24 Vdc nom (22.8 to 25.2 Vdc) with 500 ma current capability, parallel connection possible for redundant output. Current output: 400 ma with 95 Vac input, 60 C ambient temperature, 700 ma with 230 Vac input and 40 C ambient temperture. Short circuit current: 750 ma. Ripple content: 400 mvrms. Fault Output (PSD1000F only): voltage free SPDT relay contact, normally energized. De-energize in fault conditions (output overload or input line fault). Contact rating: 1 A 50 V (resistive load). Response time: 20 ms. Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive and EN60950 for electrical safety. Environmental conditions: Operating: temperature limits -20 to + 60 C, relative humidity max 90 % non condensing, up to 35 C. Storage: temperature limits 45 to + 80 C. Safety Description: II 3G Ex na IIC T4, -20 C Ta 60 C applicable to PSD1000, not for PSD1000F. Approvals: GM International CRR028 conforms to EN60079-0, EN60079-15, FM & FM-C No. 3024643, 3029921C, conforms to Class 3600, 3611, 3810 and C22.2 No.142, C22.2 No.213, E60079-0, E60079-15, DNV and KR Type Approval Certificate for marine applications. Mounting: T35 DIN Rail according to EN50022. Weight: about 150 g PSD1000, 160 g PSD1000F. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. PSD1000 Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. PSD1000F Location: Safe Area installation. Protection class: IP 20. Dimensions: Width 22.5 mm, Depth 99 mm, Height 114.5 mm. 2 PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output G.M. International ISM0089-4

Ordering information Model: PSD1000 without fault output blank with fault output F Power Bus enclosure output Front Panel and Features /B 1 2 3 4 5 6 7 8 PSD1000 unit can be mounted close to the I.S. modules (no 50 mm distance) because Vac input and Vdc output are on the same side (safe) of the unit (not for PSD1000F). PSD1000 Installation in Zone 2, Division 2 (not for PSD1000F). Universal AC input power supply. Stabilized 24 Vdc 500 ma output capability. Redundant outputs connection. PWR ON Output short circuit proof and current limited. Three port isolation, Supply/Output/Fault. EMC Compatibility to EN61000-6-2, EN61000-6-4. PSD 1000 PSD1000 ATEX, FM & FM-C Certifications (not for PSD1000F). Type Approval Certificate DNV and KR for marine applications. 13 14 15 16 High Reliability components. Simplified installation using standard DIN Rail and plug-in terminal blocks. PSD1000 Terminal block connections PSD1000 SAFE AREA 1 2 3 4 5 6 L Power Supply 115-230 Vac 7 8 N Power Supply 115-230 Vac G.M. International ISM0089-4 PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output 3

Terminal block connections SAFE AREA PSD1000F SAFE AREA 13 Fault Output 1 14 Fault Output 2 15 3 16 Fault Output 4 5 6 L Power Supply 115-230 Vac 7 8 N Power Supply 115-230 Vac 4 PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output G.M. International ISM0089-4

Function Diagram SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL PSD1000 = _ 6 L 8 N Supply 115-230 Vac 1 + 2-3 + Out 24 Vdc 4 - SAFE AREA/NON HAZARDOUS LOCATIONS MODEL PSD1000F Fault Out 13 14 16 = _ 6 L 8 N Supply 115-230 Vac 1 + 2-3 + Out 24 Vdc 4 - Relay contact shown in de-energized position G.M. International ISM0089-4 PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output 5

Warning PSD1000 is an isolated Switching Power Supply unit installed into standard EN50022 T35 DIN Rail located in Safe Area/Non Hazardous Locations or Zone 2, Group IIC, Temperature Classification T4, Class I, Division 2, Groups A, B, C, D, Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA Temperature Code T4 Hazardous Area/Hazardous Locations (according to EN/IEC60079-15, FM Class No. 3611, CSA-C22.2 No. 213-M1987, CSA-E60079-15) within the specified operating temperature limits Tamb -20 to +60 C and mounting conditions. PSD1000F is an isolated Switching Power Supply unit installed into standard EN50022 T35 DIN Rail located in Safe Area within the specified operating temperature limits Tamb -20 to +60 C and mounting conditions. Non-incendive field wiring is not recognized by the Canadian Electrical Code, installation is permitted in the US only. For installation of the PSD1000 unit in a Class I, Division 2 or Class I, Zone 2 location, the wiring between the control equipment and the PSD1000, shall be accomplished via conduit connections or another acceptable Division 2, Zone 2 wiring method according to the NEC and the CEC. With PSD1000 for Intrinsic Safety application limits the line supply voltage to a maximum of 250 Vrms, not to be connected to control equipmen that uses or generates more than 250 Vrms or Vdc with respect to earth ground. PSD1000 must be installed, operated and maintained only by qualified personnel, in accordance to the relevant national/international installation Standards (e.g. IEC/EN60079-14 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines), BS 5345 Pt4, VDE 165, ANSI/ISA RP12.06.01 Installation of Intrinsically Safe System for Hazardous (Classified) Locations, National Electrical Code NEC ANSI/NFPA 70 Section 504 and 505, Canadian Electrical Code CEC) following the established installation rules. PSD1000 power supply must be placed in an enclosure with IP4X protection degree when used in locations providing adequate protection against the entry of solid foreign objects or water capable of impairing safety, or be placed in an enclosure with IP54 protection degree for other locations when used for Intrinsic Safety installations. De-energize main power source (turn off power supply voltage), wait at least 2 minutes to discharge internal capacitors before plug or unplug the terminal blocks when installed in Hazardous Area/Hazardous Locations or unless area is known to be nonhazardous. Hazardous voltage are present at the input terminal block and inside the unit when connected to the main supply voltage, do not touch electrical connection and do not put conductive object inside the unit. Warning: PSD1000 substitution of components may impair Intrinsic Safety and suitability for Division 2, Zone 2. Explosion Hazard: to prevent ignition of flammable or combustible atmospheres, disconnect power before servicing or unless area is known to be nonhazardous. Failure to properly installation or use of the equipment may risk to damage the unit or severe personal injury. The unit has no serviceable parts inside, do not open the enclosure. The unit cannot be repaired by the end user and must be returned to the manufacturer or his authorized representative, any unauthorized modification must be avoided. Operation PSD1000, PSD1000F provides fully floating 24 Vdc supply mainly to Series D1000 modules or to drive process control equipment like instrumentation, control system, PLC or load requiring a stabilized voltage. PSD1000 can be located in Safe Area/Non Hazardous Locations or Zone 2, Group IIC, Temperature Classification T4, Class I, Division 2, Groups A, B, C, D, Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA Temperature Code T4 Hazardous Area/Hazardous Locations ensuring that the relevant safety installation conditions are respected while PSD1000F can be located in Safe Area only. PSD1000, PSD1000F provides 500 ma, 12 W output capability. The power supply has a switching input resulting in a high efficiency module. Output is protected from overload and short circuit (the unit switches the output off and then tries to re-activate it until the fault condition is removed) and is provided with a decoupling diode that permits the parallel operation to increase the current capability or redundancy operation. PSD1000F is provided with a contact relay output for detection of supply fault (input line, output overload or thermal overload); the relay is normally energized and it de-energize in fault condition. Presence of supply power and normal working condition is displayed by a green signaling LED. Installation PSD1000, PSD1000F is a switching power supply housed in a plastic enclosure suitable for installation on T35 DIN Rail according to EN50022. PSD1000, PSD1000F unit can be mounted with any orientation over the entire ambient temperature operation range, see section Installation in Cabinet and "Installation of Electronic Equipments in Cabinet" Instruction Manual D1000 series for detailed instructions. Electrical connection of conductors up to 2.5 mm² are accommodated by polarized plug-in removable screw terminal blocks which can be plugged in/out into a powered unit without suffering or causing any damage (for Zone 2 or Division 2 installations check the area to be nonhazardous before servicing). On the data sheet and enclosure side a block diagram identifies all connections. The input line is internally protected by fuse; connect an automatic bipolar C intervention characteristics switch, upstream the power supply line or other equipment to ensure compliance with local regulations. For the choice of the input automatic circuit breaker protection, it is opportune to use the following formula: Pout*1.2 Hazardous (Classified) Locations Class I, Division 2, Groups A, B, C, D Class II, Division 2, Groups E, F, G Class III, Division 2 Class I, Zone 2, Group IIC, IIB, IIA Non-incendive Equipment FM Approved under non-incendive field wiring (permitted only for US installations), or third party approval Unclassified Locations or Hazardous (Classified) Locations Class I, Division 2, Groups A, B, C, D, T-Code T4 Class I, Zone 2, Group IIC, IIB, IIA, T-Code T4 + +24Vdc 1/3 - -24Vdc 2/4 PSD1000 Power Supply FM Approved under non-incendive field wiring Itar = *1.5 where Itar = circuit breaker current, Pout = requested output power, Vin_min = minimum supply voltage. Vin_min The terminal block are not usable as breaking device. The wiring cables have to be proportionate in base to the current and the length of the cable. Identify the function and location of each connection terminal using the wiring diagram on the corresponding data sheet, as an example: Connect AC input mains power at terminal 6 L/+ and 8 N/- to the Supply Line terminal block. Connect positive output at terminal + 1 or + 3 and negative output at terminal - 2 or - 4 to the 24 Vdc Output terminal block (two connections provided). For PSD1000F connect if required the alarm indication at terminal 16 common relay contact, at terminal 13 normally close relay contact and terminal 14 normally open relay contact; the alarm is provided by an SPDT relay normally energized, it de-energizes in fault condition of the power supply. Installation and wiring must be in accordance to the relevant national or international installation standards (e.g. IEC/EN60079-14 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines), BS 5345 Pt4, VDE 165, ANSI/ISA RP12.06.01 Installation of Intrinsically Safe System for Hazardous (Classified) Locations, National Electrical Code NEC ANSI/NFPA 70 Section 504 and 505, Canadian Electrical Code CEC), make sure that conductors are well isolated from each other and do not produce any unintentional connection. The enclosure provides, according to EN60529, an IP20 minimum degree of mechanical protection (or similar to NEMA Standard 250 type 1) for indoor installation, outdoor installation requires an additional enclosure with higher degree of protection (i.e. IP54 to IP65 or NEMA type 12-13) consistent with the effective operating environment of the specific installation. PSD1000 power supply must be placed in an enclosure with IP4X protection degree when used in locations providing adequate protection against the entry of solid foreign objects or water capable of impairing safety, or be placed in an enclosure with IP54 protection degree for other locations when used for Intrinsic Safety installations. Units must be protected against dirt, dust, extreme mechanical (e.g. vibration, impact and shock) and thermal stress, and casual contacts. If enclosure needs to be cleaned use only a cloth lightly moistened by a mixture of detergent in water. Electrostatic Hazard: to avoid electrostatic hazard, the enclosure of PSD1000, PSD1000F must be cleaned only with a damp or antistatic cloth. Any penetration of cleaning liquid must be avoided to prevent damage to the unit. Any unauthorized card modification must be avoided. Start-up Unclassified Locations Must not use or generate more than 250 Vrms or Vdc 6 L/+ 8 N/- Supply Line Before powering the unit check that all wires are properly connected, particularly their polarity. Check conductors for exposed wires that could touch each other causing dangerous unwanted shorts. Turn on power, the power on green led must be lit, check the supply voltage generated by PSD1000, PSD1000F is 24 Vdc. 6 PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output G.M. International ISM0089-4