IntelliTeam II Automatic Restoration System

Similar documents
Application of Distributed Intelligence to Automatic Distribution Reconfiguration for Reliability Improvement

S&C 6801M Automatic Switch Operator

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

FAULT DETECTION ISOLATION AND RESTORATION ON THE FEEDER (FDIR): PICK YOUR TECHNOLOGY

2012 Grid of the Future Symposium. Demonstration of Pulsecloser Applications and Benefits in Ameren s Distribution Automation Program

Source-Transfer Application Guide

S&C IntelliRupter PulseCloser. Outdoor Distribution 14.4 kv and 25 kv

Advanced Fuse-Saving Techniques. T. ROUSAN Ameren Illinois USA. J. JERMAKOWICZ S&C Electric Company USA

Operating and Diagnostic Instructions for IntelliTeam SG Automatic Restoration System

Sacramen Sacr t amen o t Municipal Utility Dis t Dis rict t SMUD May Ma 10,

Auto-Changeover & Feeder Automation. Reclosers & Sectionalizers

DNP Points List and Implementation

Spencer Murray, Sr. Telecom Eng.

Setup. S&C 5800 Series Automatic Switch Controls With IntelliTeam Automatic Restoration System. Table of Contents. Instruction Sheet

DNP Points List and Implementation

Specifications. S&C IntelliNode Interface Modules. Conditions of Sale

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

DNP Points List and Implementation for Universal Controls

Loop Automation. Technical Manual for the ADVC Controller Range

Dan Murray, Siemens Energy Management Division

CIGRE U.S. National Committee

Products Portfolio. Pole mounted Vacuum Recloser

Lightweight and flexible recloser control for single-phase applications

Specifications. S&C IntelliNode Interface Modules

FCIs reduce fault-locating times and improve reliability metrics, especially the Customer Average Interruption Duration Index (CAIDI).

Synchronous switching of distribution sub networks

South Tulsa Switch Automation Pilot

Siemens FuseSaver New half-cycle circuit breaker for rural smart grids to minimize operating costs of feeder and spur lines

PG&E Points List for Universal Controls

DNP Points List and Implementation for the 6802 Vista Control

New Tools for Managing Smart Switching Devices. C.A. MCCARTHY S&C Electric Company USA

Docking Station Instructions

S&C Micro-AT Source-Transfer Controls PHOTO SHEET. For use in S&C Metal-Enclosed Gear

6800 Series Data Log Messages

Small Generator Interconnection Facilities Study Report. Completed for. ( Interconnection Customer ) Proposed Interconnection Pavant substation

S&C IntelliRupter PulseCloser Fault Interrupter

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

Table of Contents Section Page Section Page Introduction Safety Information Installation Diagrams Installation

Specifications. S&C 6802 and 6803 Automatic Switch Controls

Setup Instructions. S&C Universal Interface Module. Table of Contents. Instruction Sheet

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring

Smart Distribution Technology

The Reliability Switch

Small Generator Interconnection Facilities Study Report. Completed for Q0314 ( Interconnection Customer ) A Qualified Facility

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co.

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

MV overhead feeder automation

WiAutoLink Frequently Asked Questions

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

INTEGRATION OF RECLOSERS INTO SCADA SYSTEMS

Operation. S&C 6800 Series Automatic Switch Controls with IntelliTeam SG Automatic Restoration System. Table of Contents. Instruction Sheet

Fortum SGEM Program Presentation of ongoing research activities

Specifications. S&C Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv and 27 kv)

Specifications. S&C 6801 Automatic Switch Controls

Maximizing protection coordination with self-healing technology

1 Description of Methodology for Volt / Var Optimization

SurvalentONE Distribution Management System

An Innovative Approach to Implementing SCADA into the Industrial Environment

Wi-Fi and Security Administration

Primary Injection Test Procedure

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

AIR INTELLIGENT GRID AUTOMATION

Designing a Reliable Industrial Ethernet Network

Evolution of Control for the Power Grid

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

EPB UPDATE. North American Power Credit Organization September 12, 2013

Flexible High-Speed Load Shedding Using a Crosspoint Switch

Operation. S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Table of Contents

Fault and outage management

Third Generation System of the Future

Effect of Distribution Automation on Protective Relaying

DISRIBUTED AUTOMATION FOR BACK-FEED NETWORK POWER RESTORATION

Monitor Your Distribution Grid

SEL Protection and Communications Capabilities Integral to Power System Upgrade at Alberta s Dynamic Northlands Park

Designing a Reliable Industrial Ethernet Network

Advanced Protection and Control for a Power System Serving Industrial Customers

PS/IO Circuit Board Retrofit

To: Honorable Public Utilities Board Submitted by: From: Diosdado Hernandez, P. E. Approved by:

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

Site acceptace testing of a Duke Energy automation project utilizing a simulation based test approach

Troubleshooting. S&C 6801M Automatic Switch Operators Reciprocating and Rotating Switch Operation. Table of Contents. Instruction Sheet 1045M-550

SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,

Utility Implements Communications- Assisted Special Protection and Control Schemes for Distribution Substations

MV Network Managment Fault tracking, monitoring and control. Easergy Range Merlin Gerin

EPRI GIS Interest Group GIS Data Correction

Southern Company Smart Grid

Instructions for Operation of S&C Test Accessory Catalog Number TA-2669

Glencoe Light and Power

Specifications. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) For Remote Supervisory Control

Microgrids: Building Blocks of the Smart Grid Adaptive Protection Schemes for Microgrids

User s Guide. S&C IntelliTeam Designer. Table of Contents. Instruction Sheet

MONTANA-DAKOTA UTILITIES REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITY INTERCONNECTIONS

AMEU FuseSaver Highest availability and cost savings for your medium voltage distribution network

VisoVac padmount fault interrupter

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

Centralized & Distributed Intelligence applied to Distribution Automation

Secure, Smart Grid Data Access Radically Simplified

A low-cost, economical solution for distribution feeder protection

Transcription:

No system is too complex to automate with... IntelliTeam II Automatic Restoration System

Introduced in 1997, the IntelliTeam Automatic Restoration System was the first product of its kind. Using peer-to-peer communication with distributed intelligence, IntelliTeam software tracked system conditions to quickly initiate service restoration. IntelliTeam software was way ahead of its time. S&C s IntelliTeam II software takes automatic restoration to the next level by providing a highly scalable system that is fast and reliable. IntelliTeam II software works with S&C IntelliRupter PulseCloser Fault Interrupters, 6800 Series Automatic Switch Controls, and 6801M Automatic Switch Operators to provide solutions for both overhead and underground distribution circuits for improved service reliability for critical areas of your distribution system. IntelliTeam II software can be expanded to serve entire regions of your system. It requires no central monitoring or SCADA control, though SCADA is fully supported. With IntelliTeam II software, restoration proceeds without the delays inherent in a dispatcher-operated or centrally controlled system. IntelliTeam II monitors realtime current and voltage throughout the system and uses this information to make smart switching decisions. It acts locally before breakers or reclosers lock out. Unlike time-coordinated restoration systems that must be carefully pre-programmed, IntelliTeam II software s sophisticated operating logic can automatically restore service under multiple event contingencies. During storms or major outages, it quickly returns service to as many customers as possible, freeing utility personnel to deal with system repairs. IntelliTeam II software minimizes Customer Minutes of Interruption, improving your reliability ratings. Easily implemented IntelliTeam II software provides out-of-the-box automatic restoration functions. No custom programming or scripting is required. IntelliTeam II software is the easiest, most cost-effective way to improve service reliability. Existing S&C Automation Products can be upgraded to the IntelliTeam II system with a simple software upgrade. Fully scalable The original IntelliTeam software was limited to a single team of seven controls, with each control operating one or two switches. The switches needed to be arranged in a loop, with a source at either end and a normally open point. IntelliTeam II software, on the other hand, supports complex systems of virtually any size and accommodates tie points from multiple sources. It can handle as many teams of switches as line loading will allow. S&C s Power Systems Solutions can readily prepare a load-flow analysis of your system to determine these loading limits. And with IntelliTeam II software, each team can have up to eight controls. The switches can be arranged in radial circuits, looped circuits, or a combination of both. 38-kV IntelliRupter PulseCloser Fault Interrupter featuring IntelliTeam II software. 6801 Automatic Switch Control featuring IntelliTeam II software. 2

Maximize the efficiency of your system Restoration capacity is based on real-time loading and actual feeder capacity, not often-outdated historical loading data. The excess capacity of adjacent sources is used to restore service to unfaulted segments, helping defer the need for system upgrades and allowing you to tie circuits that traditional planning criteria wouldn t permit. Any remote terminal unit (RTU) or SCADA device using DNP 3.0 can be used to monitor feeder loading at the breaker and continuously transmit this value to the first IntelliTeam II-equipped switch outside the substation. This real-time feeder loading value is subtracted from the total feeder capacity to determine the reserve capacity. Or, S&C s IntelliNode Interface Module can be used in conjunction with your substation breaker s control to bring the breaker into the system providing protection to the first segment outside the substation. You re in control, IntelliTeam II software gives you the flexibility to select restoration strategies. You re assured that system-planning criteria are observed and that critical users get the highest priority. Compatible with existing systems IntelliTeam II-equipped controls use DNP 3.0 protocol and peer-to-peer communication via radio or fiber-optic transceivers. No substation automation, or SCADA, is required but is easily integrated with IntelliTeam II software. When the dead-banding feature of IntelliTeam II software is used, communication traffic on your SCADA system will be significantly reduced. Analog parameters such as voltage, current, and kvars are reported only when measurements exceed user-defined values. You can select either a percentage-based or a fixed dead-band value for each analog parameter. Designed with your line technicians in mind, IntelliTeam II software uses multiple blocking points to prevent automatic operation when your crews are working on the line. S&C will fully train your line technicians on this and all other features of the IntelliTeam II system with simple demonstrations utilizing actual controls. How IntelliTeam II Software Works Team and coach metaphors describe IntelliTeam II software operation. Each team is a line segment bounded by up to eight switches, each of which can represent a different power source. The software coach continually monitors the real-time voltage and current at each team member and shares this information with coaches of adjacent teams. When an outage or line fault occurs, the coach of each affected team uses the real-time data, plus voltage and current before to the system event, to develop a restoration strategy. The coaches work together to implement plays that will maximize restoration always within the prioritization rules you ve defined. IntelliTeam II operating principles are simple: Each team s mission is to maintain power on its line segment using the normal power source whenever possible. Each team communicates with neighboring teams through switch controls they share in common. The excess capacity of a neighboring team is a possible restoration source that s available at the shared switch. Each switch control monitors the current and voltage at its switch(es). If a fault occurs, the coach of the faulted team recognizes that the fault is located in its team because fault current was sensed at only one team switch. (Unfaulted teams upstream of the faulted team will have sensed fault current at multiple switches, indicating that the fault current traveled through the team.) The coach of the faulted team opens all team switches and prevents them from closing, isolating the fault. If an unfaulted team experiences extended loss of voltage, its coach evaluates the excess capacity of neighboring teams and transfers load to the first team that has sufficient capacity. The alternate source can be more than one team away; inter-team data exchange ensures the sharing of excess capacity and coordination of restoration decisions. If desired, you can prioritize the order in which alternate sources are specified. When normal power has been restored or the fault has been corrected, the system returns to its normal configuration, either manually, automatically, or via SCADA control. 3

If another event takes place after the team has transferred to an alternate source, the team will seek another alternate source to keep its line segment energized. The ability to respond to multiple contingencies makes IntelliTeam II software a much more effective tool than other systems. Each coach maintains excess-capacity statistics on adjacent teams that it can use to dynamically prioritize the restoration strategy. IntelliTeam II software can accommodate virtually any breaker reclosing sequence, provided there is at least one time-delayed reclose before lockout. Each switch closure is qualified based on pre-fault loading, and each team s capacity for transfer is correspondingly reduced as load is restored. Source 4 A Team 7 C D Team 2 E Source 2 Team 1 Team 3 B G F J H Source 4 A Team 7 C D Team 2 E Source 2 Team 1 Team 3 B G F J H Team 6 Normal configuration. Team 5 Team 4 K L M Team 6 Team 5 Team 4 K L Fault occurs in Team 7 between Switches A, B, and C. Switch A opens to isolate the fault based on its protection settings. M Team 1 J Source 2 Team 1 J Source 2 D D Source 4 A Team 7 C Team 2 Team 3 E B G F H Source 4 A Team 7 C Team 2 Team 3 E B G F H Team 6 Team 5 Team 4 K L 1. The coach in Team 7 determines the fault is in that team and opens Switches B and C. 2. Switches D and E in Team 2 open on loss of voltage. M Team 6 Team 5 Team 4 1. The coach in Team 1 closes Switch J to restore that team. 2. The coaches in Team 5 and 6 agree to close Switch K to restore Team 6. 3. The coaches in Team 2 and 3 agree to close Switch F to restore Team 2. 4. The coach in Team 2 closes Switch E to restore the end-point. 5. Fault isolation and restoration complete. K L M This example shows how IntelliTeam II software responds to a faulted segment. All switches in the affected team experience an overcurrent followed by a loss of voltage. All switches in the team open to isolate the fault. Then service is restored to all the unfaulted segments... in less than one minute! 4

IntelliTeam II Software Works with Your Equipment IntelliTeam II software works with overhead and under-ground switching equipment, including S&C s IntelliRupter PulseCloser Fault Interrupter, Scada-Mate Switching Systems, Remote Supervisory Vista Underground Distribution Switchgear, and Remote Supervisory Pad-Mounted Gear. S&C Scada-Mate Switching System. S&C IntelliRupter PulseCloser Fault Interrupter. S&C Remote Supervisory Vista Underground Distribution Switchgear. S&C Remote Supervisory Pad-Mounted Gear. 5

Descriptive Bulletin 1042-32 June 6, 2016 S&C Electric Company 2003-2016, all rights reserved Offices Worldwide sandc.com