ETT 352 Touch Operating Panel

Similar documents
HZS 352 Touch Room Unit

HZS 351 Room Touch Control Panel

ETT 312 Build-In Touch Terminal

TAE 1921 Touch Display Unit

TAE 1921 Touch Display Unit

ISE 021 S-DIAS Interface Module RS232 / RS485

ICA 012 S-DIAS Interface Module CAN

KL 181 S-DIAS +24 V Potential Distributor Module

DM 161 S-DIAS Digital Mixed Module

AO 081 S-DIAS Analog Output Module

TO 161 S-DIAS Digital Output Module

RO 051 S-DIAS Relay Output Module

SI 021 S-DIAS SSI Interface Module

TSY 041 Training System Extension Motion

VI 021 S-DIAS VARAN Control Module

PS 101 S-DIAS Power Supply Module

SE 051 S-DIAS Splitter Ethernet

HZS Internal Controller Expansion

AI 046 S-DIAS Analog Input Module

ETT 731 Build-in Terminal Touch

PC 521 Data Recording PC

ETT 412 Touch Operating Panel Technical Manual

Connection Cables for Operating Devices

ETT 771 Build-in Touch Terminal

DC S-DIAS Axis Module

ETT 732 Touch Operating Panel

MDM 011-Z1 Regen Resistor

C-DIAS Serial Interface CSI 021

VARAN Splitter Module VSV 043

HZS 772 Touch Operating Panel

Expansion Module HZS 541-1S

VARAN Splitter PROFINET VSP 042

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Keyboard Unit Sigmatek

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

ISOMETER isoev425 with coupling device AGH420

F1000 User's Manual. (Version: V1.01)

C-DIAS Digital Input Module CDI 161 with 16 inputs

PC 400 Control Cabinet PC

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

VARAN Splitter Module VSV 041

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

IP Address Settings Quick Guide

HZS Solar Module

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

C-DIAS EtherNet/IP Slave CIP 022

HZS 771 Touch Operating Panel

IGLOO IGLOO EASY INSTRUCTION MANUAL

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

User Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen

PanelView Plus/VersaView CE Terminals and Display Modules

ISOMETER isoev425/isoev425hc with coupling device AGH420

IGLOO IGLOO EASY INSTRUCTION MANUAL

Protected VARAN Digital Mixed Module PVDM 086

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

ETT 0833 Multi-Touch Operating Panel

C-DIAS Profibus DP Slave module CPB 021

SSI 021 S-DIAS Safety SSI Absolute Value Encoder

Extruder Controls ExtruVision S

JUMO mtron T Measuring, Control, and Automation System

Control Panel CP600-eCo CP604, CP604-B

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs

LCD MODULE SPECIFICATION. Model : CT57M3224A _ - Revision 01 Engineering Jackson Fung Date 22 July 2016 Our Reference

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

VARAN Splitter PROFINET VSP 044

Technical Data Sheet OPUS A3 STANDARD Basic

Installation and Operation Guide

EX-RC1 Remote I/O Adapter

27 Industrial Chassis Monitor

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

Technical Data Sheet OPUS A8 ECO Full

Control Panel CP600 CP651, CP651-WEB

MU110-6U. Analog output module 6 channel. User guide

Technical Data Sheet OPUS A8 ECO Basic

AP 701 Access Panel. Features and Functions

C-DIAS Analog Module CAO 086 For eight ±10 V Outputs

ABB i-bus KNX HCC/S Heating/cooling circuit controller

RXTH DUAL ROOM SENSOR / SWITCH

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

Room unit with PPS2 interface

DTP170. Colour Touch Screen Installation Manual. contents

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

FL MC 2000E (SM40) LC

1. Safety Precautions (Read these precautions before use.)

PX 227. DMX Demux 8. Manual

TT 1933-S Multi-touch Operating Panel

EX-RC1 Remote I/O Adapter

MultiViu Flex 4 Data Sheet

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Control Panel CP600 CP635, CP635-B, CP635-WEB

EX-RC1 Remote I/O Adapter

Transcription:

ETT 352 Touch Operating Panel Date of creation: 11.08.2014 Version date: 03.03.2017 Article number: 07-230-352-1-E

Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18 Email: office@sigmatek.at WWW.SIGMATEK-AUTOMATION.COM Copyright 2014 SIGMATEK GmbH & Co KG Translation from German All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or distributed in any form (print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur through use of this handbook.

TOUCH OPERATING PANEL ETT 352 Touch Operating Panel ETT 352 The ETT 352 is an intelligent terminal for programming and visualization of automated processes. As a room operating device, the terminal is equipped with temperature sensor. A resistive touch screen serves as the input medium for process data and parameters. The output is shown on a 3.5" TFT color display. To save energy, the display is deactivated in sleep mode. When the screen surface is touched, the terminal is activated and then deactivated a few minutes after the last input. With the LSE mask editor, graphics can be created on the PC, then stored and displayed on the terminal. Data is exchanged over a CAN bus. 03.03.2017 Page 1

ETT 352 TOUCH OPERATING PANEL Contents 1 Technical Data... 3 1.1 Performance Data... 3 1.2 Electrical Requirements... 3 1.3 Terminal... 3 1.4 Environmental Conditions... 4 1.5 Display... 4 1.6 Miscellaneous... 5 2 Mechanical Dimensions... 6 3 Connector Layout... 7 4 Mounting Instructions... 9 4.1 Panel Mount... 9 5 CAN Bus Setup...11 5.1 CAN Bus Station Number... 11 5.2 CAN Bus Data Transfer Rate... 11 5.3 Number of CAN Bus Participants... 12 5.4 Wiring the CAN Bus... 12 6 CAN Bus Termination...13 7 Cleaning the Touch Screen...14 Page 2 03.03.2017

TOUCH OPERATING PANEL ETT 352 1 Technical Data 1.1 Performance Data SDRAM (Flash) Interfaces Terminating resistor Data rate Display Resolution Control panel 8-Mbyte 1-Mbyte 1x CAN bus (fixed terminal strip) 120 settable with DIP-Switch maximum 1 Mbit/s 3.5" TFT color display 320 x 240 Pixel 4-wire touch screen (analog resistive) 1.2 Electrical Requirements Supply voltage typically +24 V DC (+18-30 V DC) Current consumption of power supply at +24 V DC typically 50 ma maximum 100 ma UL standard for UL (1) : must be supplied with SELV / PELV and Limited Energy Digital output also is SELV / Limited Energy. (1) In US according to Class 2 UL 1310 or UL 61010-1, 3 rd edition, chapter 9.4 or LPS (limited power supply) UL 60950-1 or Limited Energy UL 1585 1.3 Terminal Operating unit dimensions 93.3 x 93.3 x 12.1 mm (W x H x D) Installation dimensions with panel mount Material Weight 52 x 52 x 30 mm (W x H x D) corner hole spacing 81.3 mm plastic circa 120 g 03.03.2017 Page 3

ETT 352 TOUCH OPERATING PANEL 1.4 Environmental Conditions Storage temperature -10... +70 C Environmental temperature 0 +55 C Humidity 10-80 %, non-condensing Operating conditions Pollution degree 2 Indoor use Altitude up to 2000 m EMV product norm EN 60730-1 EMC stability EMC stability according to EN 61000-6-2 (industrial area) according to EN 61000-6-3 (living area) Protection type EN 60529 mounting in a panel IP30 (no UL-rating) 1.5 Display Type 3.5 LC graphic display Resolution 320(RGB) x 240 Pixel size Number of pixels Active surface Color depth Backlighting 0.219 x 0.219 mm 320*3 (RGB) x 240 pixels 70.08 x 52.56 mm 24-bit 6x LED, white, regulatable Contrast 400:1 Touch Brightness resistive typically 350 cd/m² Visible field left, right, below 70, above 60 Page 4 03.03.2017

TOUCH OPERATING PANEL ETT 352 1.6 Miscellaneous Article number 01-230-352-1 Hardware version 1.x Standard UL 61010-2-201 Approbations UL, cul, CE 03.03.2017 Page 5

ETT 352 TOUCH OPERATING PANEL 2 Mechanical Dimensions Page 6 03.03.2017

TOUCH OPERATING PANEL ETT 352 3 Connector Layout 03.03.2017 Page 7

ETT 352 TOUCH OPERATING PANEL X1: Supply Terminal (Weidmüller LSF-SMT 5.00/05/180 3.5SN BK TU) Pin Function 1 CAN B (HIGH) 2 CAN A (LOW) 3 n.c. 4 +24 V 5 GND n.c. = do not use Connectable Leads Wiring Min. Max. Connection dimensions 0.13 mm² 1.5 mm² Conductor cross-section AWG AWG 24 AWG 16 Single wire 0.2 mm² 1.5 mm² Fine-stranded with end sleeve 0.25 mm² 1.5 mm² End sleeve with collar 0.25 mm² 0.75 mm² X2: USB Device 1.1 (Type Mini-B) (for service purposes only) Pin Function 1 +5 V 2 D- 3 D+ 4 n.c. 5 GND S1: CAN Bus Termination (1-pin DIP-Switch) ON => CAN bus termination with 120 Page 8 03.03.2017

TOUCH OPERATING PANEL ETT 352 4 Mounting Instructions 4.1 Panel Mount 03.03.2017 Page 9

ETT 352 TOUCH OPERATING PANEL The touch operating terminal is inserted through the cutaway of the panel and secured from the back using 4 screws. Scheme Page 10 03.03.2017

TOUCH OPERATING PANEL ETT 352 5 CAN Bus Setup This section explains how to correctly configure the CAN bus. The following parameters must first be set: Station number and data transfer rate. 5.1 CAN Bus Station Number Each CAN bus station is assigned its own station number. With this station number, data can be exchanged with other stations connected to the bus. In a CAN bus system however, each station number can only be assigned once! During the initial start-up of the terminal, the setup is activated (see following image), in which the station number is set. This value must match the configuration in the software project. 5.2 CAN Bus Data Transfer Rate Various data transfer rates (baud rates) can be set on the CAN bus. As with the station number, the baud rate is defined in the setup during the initial start-up (see the following image). This value must match the configuration in the software project. The longer the bus line is, the lower the data transfer rate that must be selected. Value Baud Rate Maximum Length 0 615 Kbits/s 60 m 1 500 kbit/s 80 m 2 250 Kbits/s 160 m 3 125 Kbits/s 320 m 4 100 Kbits/s 400 m 5 50 Kbits/s 800 m 6 20 kbits/s 1200 m 7 1 Mbit/s 30 m These values apply to the following cable: 120 Twisted Pair. Note: For the CAN bus protocol: 1 kbit/s = 1 kbaud. 03.03.2017 Page 11

ETT 352 TOUCH OPERATING PANEL 5.3 Number of CAN Bus Participants The maximum number of participants on the CAN bus depends on the cable length, termination resistance, data transfer rate and the drivers used in the participants. With a termination resistance of 120, at least 100 participants are possible. 5.4 Wiring the CAN Bus For the CAN bus wiring, a shielded cable containing two twisted pairs is used. The wires server to transmit the CAN-A and CAN-B signals, while the shielding provides the reference potential CAN_GND. Since the HZS 352 has no connection for CAN_GND, it is sufficient in this case, to connect the shielding on one side at the opposite end. Page 12 03.03.2017

TOUCH OPERATING PANEL ETT 352 6 CAN Bus Termination In a CAN bus system, both end modules must be terminated. This is necessary to avoid transmission errors caused by reflections in the line. The termination is made by an internal 120 resistor between CAN A (LOW) and CAN B (HIGH). 03.03.2017 Page 13

ETT 352 TOUCH OPERATING PANEL 7 Cleaning the Touch Screen CAUTION! Before cleaning the touch screen, the terminal must first be turned off to avoid unintentionally triggering functions or commands! ATTENTION! Avant de nettoyer l'écran tactile, le terminal doit d'abord être éteint afin d éviter un déclanchement involontaire des commandes! The terminal's touch screen can only be cleaned with a soft, damp cloth. A screen cleaning solution such as an anti-static foam, water with a mild detergent or alcohol should be used to dampen the cloth. The cleaning solution should be sprayed onto the cloth and not directly on the terminal. The cleaning solution should not be allowed to reach the terminal electronics, for example, through the ventilation slots. No erosive cleaning solutions, chemicals, abrasive cleansers or hard objects that can scratch or damage the touch screen may be used. If the terminal comes in contact with toxic or erosive chemicals, carefully clean the terminal immediately to prevent corrosion! To ensure the optimal function of the terminal, the touch screen should be cleaned at regular intervals! Pour garantir le fonctionnement optimal du terminal, le terminal doit être nettoyé régulièrement! To extend the lifespan of the touch screen as much as possible, using the fingers to operate the terminal is recommended. Pour prolonger la durée de vie de l'écran tactile on recommande d utiliser les doigts pour l opérer. Page 14 03.03.2017

TOUCH OPERATING PANEL ETT 352 Documentation Changes Change date Affected page(s) Chapter Note 08.10.2014 3 1.3 Electrical Requirements changed to +18-30 V DC 23.03.2015 4 1.6 Miscellaneous Changed article number 06.05.2015 1 Photo changed 25.03.2016 5 1.5 Display Table updated 23.01.2017 3 4 5 03.03.2017 11, 12 12 1.2 Electrical Requirements 1.4 Environmental Conditions 1.6 Miscellaneous 5.1 CAN Bus Station Number 5.2 CAN Bus Data Transfer Rate 5.3 Number of CAN Bus Participants 5.4 CAN Bus Wiring Table content changed Note on the setup expanded Screenshot setup expanded Chapter moved Chapter expanded 03.03.2017 Page 15

ETT 352 TOUCH OPERATING PANEL Page 16 03.03.2017