Environmental. Electrical Specifications at 25 O C E Output Constant Current

Similar documents
Environmental. Electrical Specifications at 25 O C E Output Constant Current

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value

Constant Voltage Mode

HEC-100RTN-48QSCA Rev A1.0

S025W-056C W Programmable LED Drivers

LED55WPG Programmable LED Driver

Power Factor Model Number Voltage Voltage

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

12-15VDC (12V±5%) 24-28VDC (24V±5%)

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Output Voltage in Constant Voltage Mode. Model Number

Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

IEC/EN/UL60950 & CE certified, EN55032 Class B

Typical Efficiency (2) 0 ~ 12.5 A 150 W 90.0% EUV-150S012DTA(STA) 0 ~ 6.25 A 150 W 90.5% EUV-150S024DTA(STA) (4)

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Max. Output Power. Typical Efficiency (1) 350 ma 90 ~ 305 Vac 107~214Vdc 75 W 92% EUC-075S035DT(3)

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Efficiency (1) 110Vac 220Vac

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Safety Standards. Model Number: Unit Weight:

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Universal input VAC <150mW No load power consumption

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

SAMSUNG ELECTRO-MECHANICS CO., LTD

SPECIFICATIONS: PSAK650

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST) (3 ) Parameter Min. Typ. Max. Notes

Max. Output Power. Typical Efficiency (1) 12 Vdc 249~ 528 Vac 0~10 A 120 W 91.5% ESV-150S012ST

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Safety Standards. Model Number:

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

7.5 Watt AC-DC Switch Power Supply

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number:

Efficiency (1) 110Vac 220Vac

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Features. LED Driver. RCOB Constant Current Active PFC Single Output. AC/DC Converter

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

DDR-120 series. 120W DIN Rail Type DC-DC Converter

Safety Standards. Model Number:

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Safety Standards. Model Number:

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AMEPR30D-AZ up to 2A AC-DC LED driver

Safety Standards. Model Number:

RM- S/_ Protection (3) Isolation Option (4) Single

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

LED DRIVER SPECIFICATIONS

Typical Efficiency (2) 500 ma 90 ~ 305 Vac 32~64 Vdc 32 W 87.0% EUC-035S070SVM0004

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

2 Output current 200~1500mA ripple LF(<120HZ) 3 % Ripple = peak / average; ripple HF 30 % Input. No applicable 3.75KV. No applicable Enclosure

ORDERING INFORMATION SEE PAGE 6

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS

Packaging (5) Protection (3) Isolation Voltage (4)

FEATURES. Nominal Output Voltage and Current

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

Features. Applications and Benefits TRC ELECTRONICS, INC

030AAC Highlights & Features

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Safety Standards. Model Number:

Safety Standards. Model Number:

87%(Typical)at 55V/0.91A load condition

Transcription:

12 Watt - Model: Environmental Drive Mode: Constant Current or Constant Voltage Technology: PFC Off-Line Switch Mode : Max. Input Voltage: 120 to 277VAC, 47-63Hz Number of Outputs: One Output Voltages: 6VDC - 48VDC Output Currents: 250mA - 1000mA 1. Operating temperature: Tc 80C Maximum. Reference -30 to +50 C ambient 2. Storage temperature range: -40 to +85 C 3. Humidity (non-condensing): 5% - 95%RH 4. Cooling: Convection 5. Vibration Frequency: 5-55Hz/2g, 30 minutes 6. Impact resistance: 1g/s 7. MTBF@ 40 O C: 550,000 hours @ Full Load per MIL-217F Notice 2. Safety and Compliance 1. UL8750, EN61347, CSA 22.2 safety compliant 2. FCC, 47CFR Part 15 Class B & EN55015 compliant. 3. Water resistant and Dust Proof Design: IP66, NEMA4, for Dry, Damp, Wet Locations. 4. Compact, Lightweight Design. 5. Safety Isolation between Primary and Secondary 6. Meets EN61000-3-2 & EN61000-3-3 Class C 7. Protection: output over-voltage, output over-current, output short circuit, auto-recovery. 8. EN61000-4-5: 2kV L-N, 8/20 µsec surge protection. Electrical Specifications at 25 O C Input voltage range: 120-277Vac (Full Range 100 to 305VAC) Frequency: 47-63HZ Power Factor: > 0.90 at > 50% Load 120Vac, > 95% Load 230/277Vac THD: < 20% at > 50% Load 120Vac, > 60% 230/277Vac Inrush current: <10A at 25C, 230V, cold start, Max. Load Input current: 0.12A at 120Vac, 60Hz, Maximum Load Efficiency: 80% typical at 120Vac 60Hz, 230Vac 50Hz Maximum output power: Per table below Line regulation accuracy: + 3% Load regulation accuracy: + 4% Constant Current Versions E325626 IP66 Part Number US CN Output Voltage Range Output Constant Current Current Accuracy Maximum Typical Efficiency (1) LD-48-C0250 YES YES 24-48 VDC 250 ma + 3% 80% LD-36-C0350 YES YES 18-36 VDC 350 ma + 3% 12.6W 80% LD-36-C0250 YES YES 18-36 VDC 250 ma + 3% 9W 77% LD-24-C0500 (2) YES YES 12-24 VDC 500 ma + 3% 78% LD-16-C0800 YES YES 8-16 VDC 800 ma + 3% 12.8W 78% LD-16-C0700 YES YES 8-16 VDC 700 ma + 3% 11.2W 78% LD-12-C1000 (2) YES YES 6-12 VDC 1000 ma + 3% 77% Constant Voltage Versions Part Number US CN Output Voltage Output Current Range Voltage Accuracy Maximum Typical Efficiency (1) LD-48 YES YES 48 VDC 63-250 ma + 5% 80% LD-36 YES YES 36 VDC 88-350 ma + 5% 12.6W 80% LD-24 (2) YES YES 24 VDC 125-500 ma + 5% 78% LD-16 YES YES 16 VDC 200-800 ma + 5% 12.8W 78% LD-12 (2) YES YES 12 VDC 250-1000 ma + 5% 77% Notes 1. Typical efficiency measured at 230VAC input, full load. 2. SAM Recognized Custom designs available. Please consult the factory. Specifications subject to change without notice 1 EPtronics, Inc. Inc. Los Los Angeles, California T: T: 800 800 643-0688 E: E: Sales@EPtronics.com Sales@EPtroncs.com www.eptronics.com Rev. E1.2 08/01/2010-04/25/2017 1

12 Watt - Mechanical Dimensions: Inches [mm] Labeling Example Material: Black PC ABS Plastic Case Fully Encapsulated Weight: 128 grams (4.5 oz) Typical 2 Specifications subject to change without notice Custom designs available. Please consult the factory.

12 Watt - Input Specifications Input Voltage 100 Vac 305 Vac 120, 230, 240, 277 Vac Nominal Values Input Frequency 47 Hz 63 Hz 50/60Hz Nominal Input AC Current 0.13A Measured at 120Vac/60Hz Input, Output Full load. 0.07A Measured at 230Vac/50Hz Input, Output Full load. 0.06A Measured at 277Vac/60Hz Input, Output Full load. Inrush Current (Peak) 10A Measured at 277Vac/60Hz Input, Output Full Load, Ta 25 O C, Cold Start Inrush Current (I 2 t) 0.04 A 2 s 50% Ipeak duration ~750 µsec (1/2*Ip 2 *t) Leakage Current 0.36mA 0.50mA Measured at 120Vac/60Hz Input, Output Full load. 0.61mA 0.75mA Measured at 277Vac/60Hz Input, Output Full load. THD 20% THD: < 20% at > 50% Load 120Vac, > 60% 230/277Vac Power Factor (PF) 0.90 PF: > 0.90 at > 50% Load 120Vac, > 95% Load 230/277Vac Output Specifications DC Output Voltage Per Table Per Table Per Tables on Page 1 DC Output Constant Current -4% Per Table +4% Per Tables on Page 1 Per Table Per Tables on Page 1 Ripple & Noise (Vpk-pk) 20% Vo 20 MHz BW, Full load output in parallel with 0.1 µf ceramic & 10 µf Electrolytic. Ripple (Ipk-pk) 50% Io 20 MHz BW, Full load output in parallel with 0.1 µf ceramic & 10 µf Electrolytic. 120 Hz component Start-up Time 700 ms 1000 ms Measured at 120Vac/60Hz Input, Output Full load. Hold-up Time 30 ms Typical @ 277Vac Input, Output Full load. Environmental Specifications Case Temperature (Tc) -30 O C +80 O C Measured at location specified on case. Operating Temperature (Ta) -30 O C +50 O C This is a reference range. Tc controls temperature range. Storage Temperature (Ts) -40 O C +85 O C Non operating temperature range. Operating Humidity 95% RH Relative Humidity, non-condensing. Vibration 5 Hz 55 Hz 2G, 10 minutes/1 cycle, period 30 minutes, each along X, Y, Z axis. MTBF 482,000 Hours MIL-HDBK-217F Notice 2, Ta = 25C, Output Full Load. Protection Specifications Output Short Circuit (SCP) No Damage, Auto recovery after short is removed. Output Over Current (OCP) +8% Io Constant Current Limiting circuit. Output Over Voltage (OVP) 120% Vo No Damage, Auto recovery after fault is removed. Custom designs available. Please consult the factory. Specifications subject to change without notice 3

12 Watt - Safety Compliance Safety Notes/Standards UL/CUL UL8750, UL1310 for UL & CAN/CSA C22.2 No. 250.13 CE Withstand Voltage Isolation Resistance EN61347-1, EN61347-2-13 Input to Output: 3750 Vac Input to Output: >100 MΩ, 500VDC @ 25 O C, 70 % RH EMC Compliance Standard FCC, 47CFR Part 15 EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61000-4-5 Energy Star Class B Notes/Conditions Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment. Part 3-2: Limits for harmonic current emissions Class C, >80% Rated Power Part 3-3: Limitation of voltage changes, voltage fluctuations and flicker. Part 4-5: Surge Immunity test, 2 kv L-N Energy Star transient protection: Ballast or driver shall comply with ANSI/IEEE C62.41.1-2002 and ANSI/IEEE C62.41.2-2002, Category A operation. The line transient shall consist of seven strikes of a 100 khz ring wave, 2.5 kv level, for both common mode and differential mode. Power Factor Curves (Typical) 1.000 PF vs. 0.950 0.900 Power Factor 0.850 0.800 0.750 0.700 100V/60Hz 120V/60Hz 230V/50Hz 277V/60Hz 0.650 0.600 50% 60% 80% 100% 4 Specifications subject to change without notice Custom designs available. Please consult the factory.

12 Watt - THD Curves (Typical) 40.00% THD vs. 35.00% Total Harmonic Distortion 30.00% 25.00% 20.00% 15.00% 10.00% 5.00% 100V/60Hz 120V/60Hz 230V/50Hz 277V/60Hz Spec 0.00% 50% 60% 80% 100% Efficiency Curve (Typical) 100.00% Efficiency vs. Efficiency 95.00% 90.00% 85.00% 80.00% 75.00% 70.00% 65.00% 60.00% 55.00% 50.00% 50% 61% 81% 100% 100V/60Hz 120V/60Hz 230V/50Hz 277V/60Hz Typ. Custom designs available. Please consult the factory. Specifications subject to change without notice 5

12 Watt - Life vs. Ambient Temperature Life vs. Case (Tc) Temperature 6 Specifications subject to change without notice Custom designs available. Please consult the factory.