I 2 S Triggering and Hardware-based Decode (Option SND) for Agilent InfiniiVision Oscilloscopes

Similar documents
I 2 C and SPI Protocol Triggering and Decode for Infiniium 8000 and Series Oscilloscopes

PCI Express Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

Agilent Technologies Infiniium MSO8000 and MSO9000 Series N5397A FPGA Dynamic Probe for Xilinx

Agilent Technologies InfiniiVision MSO N5406A FPGA Dynamic Probe for Xilinx

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Product Note

N4010A Wireless Connectivity Test Set and N4011A MIMO/ Multi-port Adapter

I 2 C and SPI Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium Series Oscilloscopes

Agilent E5061B Network Analyzer. Configuration Guide

Agilent InfiniiMax III probing system

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

N7624B Signal Studio for LTE Technical Overview

Agilent Modern Connectivity Using USB and LAN I/O Converters

Keysight Technologies RS232/UART Protocol Triggering and Decode for Infiniium Series Oscilloscopes. Data Sheet

E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software for Infiniium Oscilloscopes

Keysight Technologies I 2 C and SPI Protocol Triggering and Decode

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

FPGA Circuit Design: Overcoming Power-Related Challenges

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

N2753A and N2754A Windows XP to Windows 7 Upgrade Kits. For Infiniium 9000, 90000, and X-Series Oscilloscopes

MIPI D-PHY Multilane Protocol Triggering and Decode

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

Infiniium MSO8000, MSO9000A and MSO 9000 H-Series N5397A FPGA Dynamic Probe for Xilinx

Agilent 11713B/C Attenuator/Switch Driver

Agilent L4445A Microwave Switch/Attenuator Driver

Assessing the use of IVI drivers in your test system: Determining when IVI is the right choice

Keysight N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope. Data Sheet

Agilent InfiniiMax III probing system

Keysight Technologies N8825A/B Infiniium 10BASE-T / 100BASE-TX Ethernet Decoder. Data Sheet

Agilent Technologies B4656A FPGA Dynamic Probe for Altera

Agilent N8300A Wireless Networking Test Set N630XA Measurement Applications and N7300 Series Chipset Software

Agilent E4982A LCR Meter

W2630 Series DDR2 BGA Probes for Logic Analyzers and Oscilloscopes

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Agilent E5072A ENA Series Network Analyzer

Advanced Test Equipment Rentals ATEC (2832) Why Migrate from HP/Agilent 432A/B to Agilent N432A Thermistor Power Meter?

Agilent Technologies E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software for Infiniium Oscilloscopes

Agilent B4655A FPGA Dynamic Probe for Xilinx

Agilent N1918A Power Analysis Manager

N5435A Infiniium Server-Based License for Infiniium Oscilloscopes

Probing High-speed Signals with the Agilent Series of Wide-bandwidth Sampling Oscilloscopes

Agilent 34450A 5.5 Digit Bench Digital Multimeter. Turbo charge your measurements with one of the fastest throughput digital multimeter in its class

Agilent E5818A LXI Class-B Trigger Box. Data Sheet

Keysight N8840A USB Power Delivery Electrical and Protocol Compliance Test Software

MXG X-Series Signal Generators N5181B Analog & N5182B Vector. Configuration Guide

VISA, SICL, VISA COM,

Keysight N2753A and N2754A Windows XP to Windows 7 Upgrade Kits For Infiniium 9000, 90000, and X-Series Oscilloscopes. Configuration Guide

Agilent N4880A Reference Clock Multiplier

N2870A Series Passive Probes and Accessories

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE

Keysight N8841A CAUI-4 Electrical Performance Validation and Conformance Software

W3630A Series DDR3 BGA Probes for Logic Analyzers and Oscilloscopes

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE

Using the U8030 Series Power Supply Output Sequencing Feature

Keysight DSOX4USBSQ and DSOX6USBSQ USB 2.0 Signal Quality Test Option for 4000 and 6000 X-Series. Data Sheet

Technical Overview. Key Features

N2870A Series Passive Probes and Accessories

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies

Agilent U2941A Parametric Test Fixture

Keysight Technologies DSOX4USBSQ USB 2.0 Signal Quality Test Option for 4000 X-Series. Data Sheet

Agilent 16962A 2 GHz State, 2/4/8 GHz Timing Logic Analyzer Module

Agilent Specifying and Buying a Bench Power Supply. Application Note

Keysight Technologies N8806A User Defined Function for Editing and Execution for Infiniium Oscilloscopes. Data Sheet

Agilent N8300A Wireless Networking Test Set

Keysight Technologies EPM and EPM-P Series Power Meters E-Series Power Sensors. Configuration Guide

Agilent N5431A XAUI Electrical Validation Application for Infiniium Oscilloscopes and Digital Signal Analyzers

EXG X-Series Signal Generators N5171B Analog & N5172B Vector

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent Technologies U7243A USB 3.0 Superspeed Electrical Performance Validation and Compliance Software for the Infiniium Series Oscilloscopes

N6468A SFP+ Electrical Performance Validation and Conformance Software

Serial Bus Applications for InfiniiVision 3000 X-Series Oscilloscopes

Cathodic Protection of Steel in Concrete Using LXI. Application Note

Solutions for Streamline Field Test with Agilent N9342C Handheld Spectrum Analyzer (HSA)

Differential Probes TDP1500 TDP3500 Data Sheet

Build Operator Menu Multiple menu configuration control for the 5DX Auto UI

Keysight W2630 Series DDR2 BGA Probes for Logic Analyzers and Oscilloscopes. Data Sheet

Keysight Technologies N6472A IEEE802.3bs/cd Compliance Application

Agilent 8960 Series 10 Wireless Communications Test Set

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

Agilent EEsof EDA.

Improving Test Throughput with Addressable Arrays and the Agilent N9201A

Agilent 66000A 1200 W DC Modular Power System, GPIB

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

Tektronix Logic Analyzer Probes P5900 Series Datasheet

Keysight E6964A Automotive Ethernet MDI S-parameter Compliance Solution

Agilent E363xA Series Programmable DC Power Supplies

Keysight Technologies E4982A LCR Meter

Keysight N5435A Infiniium Server-Based License for Infiniium Oscilloscopes

Keysight Technologies 8163B Lightwave Multimeter 8164B Lightwave Measurement System 8166B Lightwave Multichannel System.

Keysight Technologies Methods for Characterizing and Tuning DC Inrush Current. Application Brief

Agilent ENA RF Network Analyzer

Keysight Technologies N5394A DVI Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes. Data Sheet

Agilent U7233A DDR1 Compliance Test Application with LPDDR and mobile-ddr Support for Infiniium Series Oscilloscopes. Data Sheet

Keysight Technologies

Keysight B4655A FPGA Dynamic Probe for Xilinx. Data Sheet

Power Analyzer Firmware Update Utility Version Software Release Notes

Agilent E3640A E3649A Programmable DC Power Supplies

TestJet/VTEP Hardware Description and Verification

Transcription:

I 2 S Triggering and Hardware-based Decode (Option SND) for Agilent InfiniiVision Oscilloscopes Data Sheet Find and debug intermittent errors and signal integrity problems faster Features: I 2 S serial bus triggering I 2 S hardware-based protocol decoding User-selectable signal alignment selections Multiple triggering selections I 2 S (Inter-IC Sound, or Integrated Interchip Sound), is an electrical serial bus interface standard used for connecting digital audio devices together, such as compact disc, digital audio tape, digital sound processors, and digital TV sound. Traditional methods of debugging serial busses such as I 2 S includes manual bit counting. But this visual technique of counting 1 s and 0 s can be tedious and prone to errors, especially since I 2 S is typically formatted in a 2 s complement format. Agilent Technologies serial bus options for the InfiniiVision oscilloscopes not only offers powerful triggering, but also provides unique hardware-accelerated decoding to help you debug audio designs with the I 2 S bus faster. With the industry s fastest serial decode update rates, you can more easily find and debug random and intermittent errors and signal integrity problems that you could easily miss using other serial bus decode tools.

Other oscilloscope solutions with serial bus triggering and protocol decode typically use software postprocessing techniques to decode serial packets/frames. Using these software techniques, waveform- and decode-update rates tend to be slow (sometimes seconds per update), especially when you use deep memory, which is often required to capture multiple packetized serial signals. Figure 1 shows an example of decoding a stream of 2 channels of transmitted 8-bit audio data based on standard WS/SCLK timing alignment. The trigger condition for this example was set to synchronize on an increasing data value generated by the left channel of digital transmission captured on channel-1 of the oscilloscope (yellow trace). Figure 1: An InfiniiVision series oscilloscope capturing and decoding 2 channels of I 2 S audio data. Performance characteristics SCLK, WS, and SDATA source Analog channels 1, 2, 3, or 4 Digital channels D0 D15 (on MSO models) Bus Configuration: Transmitted Word Size Decoded/Receiver Word Size Alignment Word Select - Low SCLK Slope Decoded Base Triggering: Audio Channel Trigger Modes Color-coded decode: Left Channel Right Channel Error Word Size Indicator 4 to 32 (user selectable) 4 to 32 (user selectable) Standard, Left-justified, or Right-justified Left-channel or Right-channel Rising edge or Falling edge Hex (2 s complement) or Signed Decimal Audio Left, Audio Right, or Either = (Equal to entered data value) (Not equal to entered data value) < (Less than entered data value) > (Greater than entered data value) >< (Within range of entered data values) <> (Out of range of entered data values) Increasing value that crosses armed (<=) and trigger (>=) entered data values Decreasing value that crosses armed (>=) and trigger (<=) entered data values R: decoded value in green L: decoded value in white ERR in red (mismatch between transmitted and received word size, or invalid input signaling) # of TX / # of RX CLKS in blue displayed above each decoded word 2

Agilent InfiniiVision Portfolio Agilent s InfiniiVision lineup includes 5000, 6000 and 7000 Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specific needs. Largest display, shallow depth Optional battery, 100 MHz MSO Ideal for ATE rackmount applications Smallest form factor, lowest price Bandwidth 7000 Series 6000S Series 6000L Series 5000 Series 100 MHz Bandwidth 300/350 MHz Bandwidth 500 MHz Bandwidth 1 GHz Bandwidth MSO Models GPIB Connectivity Rackmount height 7U 5U 1U 5U Battery option Display size 12.1 6.3 6.3 Footprint (WxHxD) 17.9 x 10.9 x 6.8 15.7 x 7.4 x 11.1 17.1 x 1.7 x 10.6 15.2 x 7.4 x 6.9 Agilent s InfiniiVision oscilloscope portfolio offers: A variety of form factors to fit your environment Insightful application software Responsive controls and best signal visibility Responsive deep memory with MegaZoom III 3

Ordering Information The I 2 S trigger and decode option is compatible with all 4-channel and 4+16 channel Agilent InfiniiVision Series oscilloscopes (5000, 6000, and 7000 series scopes). This option is available as a factory-installed option if ordered as Option-SND along with a specific oscilloscope model, or existing InfiniiVision Series oscilloscope users can order this option as an afterpurchase product upgrade (N5468A). Model number user installed Option number factory installed Description N5468A SND I 2 S triggering and decode (4 and 4+16 channel models only) N5457A 232 RS232/UART triggering and decode (4 and 4+16 channel models only) N5423A LSS I 2 C/SPI serial decode option (4 and 4+16 channel models only) N5424A AMS CAN/LIN automotive triggering and decode (4 and 4+16 channel models only) N5432B FR2 FlexRay automotive triggering and decode (4+16 channel models only and requires VPT1000 FlexRay Vehicle Protocol Tester) N5454A SGM Segmented Memory Note that additional options and accessories are available for Agilent InfiniiVision Series oscilloscopes. Refer to the appropriate 5000, 6000, or 7000 Series data sheet for ordering information about these additional options and accessories, as well as ordering information for specific oscilloscope models. 4

Related Agilent literature Publication title Publication type Publication number Agilent Technologies Oscilloscope Family Brochure Brochure 5989-7650EN Agilent 7000 Series InfiniiVision Oscilloscopes Data sheet 5989-7736EN Agilent 6000 Series InfiniiVision Oscilloscopes Data sheet 5989-2000EN Agilent 5000 Series InfiniiVision Oscilloscopes Data sheet 5989-6110EN Agilent InfiniiVision Series Oscilloscope Probes and Data sheet 5968-8153EN Accessories Segmented Memory Acquisition (5454A) for Agilent Data sheet 5989-7833EN InfiniiVision Series Oscilloscopes RS-232/UART Triggering and hardware-based decode Data sheet 5989-7832EN (N5457A for Agilent InfiniiVision Series Oscilloscopes I2C and SPI triggering and hardware-based decode Data sheet 5989-5126EN (N5423A) for Agilent InfiniiVision Series Oscilloscopes CAN/LIN (N5424A) decode and triggering option for Data sheet 5989-6220EN Agilent InfiniiVision Series Oscilloscopes FlexRay (N5432B) decode and triggering option for Data sheet 5989-9635EN Agilent InfiniiVision Series Mixed Signal Oscilloscopes Evaluating Oscilloscopes for Best Signal Visibility 5989-7885EN Debugging Embedded Mixed-Signal Designs Using Mixed Signal Oscilloscopes Using an Agilent InfiniiVision MSO to Debug an Automotive CAN Bus Choosing an Oscilloscope with the Right Bandwidth for your s Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity Evaluating Oscilloscope Vertical Noise Characteristics To download these documents, insert the publication number in the URL: http://cp.literature.agilent.com/litweb/pdf/xxxx-xxxxen.pdf 5989-3702EN 5989-5049EN 5989-5733EN 5989-5732EN 5989-3020EN Product Web site For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/i2s 5

Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to >90 GHz Industry leading specs Powerful applications 6

Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Windows is a U.S. registered trademark of Microsoft Corporation. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to www.agilent.com/find/removealldoubt www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700 Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2008 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2009 Printed in USA, June 20, 2009 5990-4198EN