Model Number Structure

Similar documents
Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Model Number Structure

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Model Number Structure

Model Number Structure

Model Number Structure

Model Number Structure

NPN output. 200 mm. Type Cable length Model Remarks

Model Number Structure

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

NJ-Series Power Supply Unit NJ-PA/PD

Model Number Structure

Solid-state Timer H3YN

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Photoelectric Sensor

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

E2K-X4ME1 2M E2K-X4ME2 2M

Model NPN output PNP output Standard. configuration

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Model Number Structure

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Model Number Structure

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Intelligent Flag Amplifier

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

S82S (3/7.5-W Models)

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Handheld Reader Writer

Model Number Structure

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Solid State Relays with Failure Detection Function

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Number of input channels

Ordering Information. Interface Converter K3SC. List of Models

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Model Number Structure

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Solid-state Timers H3DK

Conductive Level Controller

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Limit Switch Connectors

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Limit Switch Connectors

Solid-state Timers H3DK

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

Model Number Structure

Ex. H3Y-2-C 110 VAC 30 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Ordering Information. Interface Converter K3SC. List of Models

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Model Number Structure

Three-phase Phase-sequence Phase-loss Relay

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Transcription:

Solid-state Twin Timers CSM DS_E_1_5 DIN 48 48-mm Twin Timers Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. ON- and OFF-times can be set independently and so combinations of long ON- or OFF-time and short OFF- or ONtime settings are possible. Sixteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h depending on the model to be used. Models with a flicker ON start or flicker OFF start are available. Easy sequence checks through instantaneous outputs for a zero set value at any time range. Length, when panel-mounted with a Socket, of 80 mm or less. 11-pin and 8-pin models are available. Model Number Structure Model Number Legend H3CR - F @ @ - @ @ 1 2 3 4 5 1. Classification F: Twin timers 2. Configuration None: 11-pin socket 8: 8-pin socket 3. Twin Timer Mode None: Flicker OFF start N: Flicker ON start 4. Time Range None: 0.05 s to 30 h models 300: 1.2 s to 300 h models 5. Supply Voltage 100-240AC: 100 to 240 VAC 24AC/DC: 24 VAC/VDC 12DC: 12 VDC 48-125DC: 48 to 125 VDC Ordering Information List of Models Operating Supply 0.05 s to 30 h models 1.2 s to 300 h models modes voltage 11-pin models 8-pin models 11-pin models 8-pin models Flicker OFF 100 to 240 VAC 100-240AC 8 100-240AC -300 100-240AC 8-300 100-240AC start 24 VAC/DC 24AC/DC 8 24AC/DC -300 24AC/DC 8-300 24AC/DC 12 VDC 12DC 8 12DC -300 12DC 8-300 12DC 48 to 125 VDC 48-125DC 8 48-125DC -300 48-125DC 8-300 48-125DC Flicker ON start 100 to 240 VAC N 100-240AC 8N 100-240AC N-300 100-240AC 8N-300 100-240AC 24 VAC/DC N 24AC/DC 8N 24AC/DC N-300 24AC/DC 8N-300 24AC/DC 12 VDC N 12DC 8N 12DC N-300 12DC 8N-300 12DC 48 to 125 VDC N 48-125DC 8N 48-125DC N-300 48-125DC 8N-300 48-125DC Note: Specify both the model number and supply voltage when ordering. Example: 100-240AC Supply voltage 1

Accessories (Order Separately) Adapter, Protective Cover and Hold-down Clip Name/specifications Flush Mounting Adapter Y92F-30 Y92F-73 *1 Y92F-74 *1 Protective Cover Y92A-48B *2 Hold-down Clip For PF085A Socket Y92H-8 (Sold in sets of two) For PL08 and PL11 Sockets Y92H-7 Models Note: Refer to H3CR-A datasheet for details. *1 The Y92F-48B Front Cover and the Y92P-48G@ Panel Cover cannot be used at the same time. *2 The Y92F-48B Front Cover is made from hard plastic. Remove the Front Cover to change the set value. The Y92F-48B Front Cover and the Y92F-73/-74 Flush Mounting Adapter also cannot be used at the same time. Sockets Timer Round Sockets Pin Connection Terminal Models 11-pin Front Connecting DIN track mounting P2CF-11 DIN track mounting P2CF-11-E (Finger-safe type) Back Connecting Screw terminal P3GA-11 Solder terminal PL11 Wrapping terminal PL11-Q PCB terminal PLE11-0 8-pin Front Connecting DIN track mounting P2CF-08 DIN track mounting P2CF-08-E (Finger-safe type) DIN track mounting PF085A Back Connecting Screw terminal P3G-08 Solder terminal PL08 Wrapping terminal PL08-Q PCB terminal PLE08-0 Note: 1. The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals. 2. The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection. 3. For details, refer to Socket and DIN Track Products. Terminal Cover Application Model Remarks For back connecting socket Y92A-48G For P3G-08 and P3GA-11 Note: For details, refer to Socket and DIN Track Products. 2

Specifications General Time Ranges 0.05 s to 30 h Models Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. 1.2 s to 300 h Models Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0. Ratings Item 8 N 8N Operating mode Flicker OFF start Flicker ON start Pin type 11-pin 8-pin 11-pin 8-pin Operating/Reset method Output type Mounting method Approved standards Time-limit operation/time-limit reset or self-reset Relay output (DPDT) DIN track mounting, surface mounting, and flush mounting UL508, CSA C22.2 No.14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1. Time unit s (sec) 10 s (10 sec) min (min) h (hrs) Setting 1.2 0.05 to 1.2 1.2 to 12 0.12 to 1.2 3 0.3 to 3 3 to 30 0.3 to 3 12 1.2 to 12 12 to 120 1.2 to 12 30 3 to 30 30 to 300 3 to 30 Time unit 10 s (10 sec) 10 min (10 min) h (hrs) 10 h (10 hrs) Setting 1.2 1.2 to 12 1.2 to 12 0.12 to 1.2 1.2 to 12 3 3 to 30 3 to 30 0.3 to 3 3 to 30 12 12 to 120 12 to 120 1.2 to 12 12 to 120 30 30 to 300 30 to 300 3 to 30 30 to 300 Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC Operating voltage range 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models Power reset Minimum power-opening time: 0.1 s Power consumption 100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC 24 VAC/VDC: approx. 2 VA (1.7 W) at 24 VAC approx. 1 W at 24 VDC 48 to 125 VDC: approx. 1.5 W at 125 VDC 12 VDC: approx. 1 W at 12 VDC Control outputs Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1) Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model. 2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details. 3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor. 3

Characteristics Note: Refer to the Life-test Curve. Accuracy of operating ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s) time Setting error ±5% FS ±50 ms max. Reset time 0.1 s max. Reset voltage 10% max. of rated voltage Influence of voltage ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s) Influence of temperature ±1% FS max. (±1% FS ±10 ms max. in ranges of 1.2 and 3s) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance 3 kv (between power terminals) for 100 to 240 VAC, 48 to 125 VDC 1 kv for 12 VDC, 24 VAC/DC 4.5 kv (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 48 to 125 VDC 1.5 kv for 12 VDC, 24 VAC/DC ±1.5 kv (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±400 V for 12 VDC Malfunction: 8 kv Destruction: 15 kv Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions Destruction: 980 m/s 2 three times each in six directions Malfunction: 98 m/s 2 three times each in six directions Ambient temperature Operating: 10 C to 55 C (with no icing) Storage: 25 C to 65 C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note) EMC (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2: 6 kv contact discharge (level 3) 8 kv air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kv power-line (level 3) 2 kv I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kv line to line (level 3) 2 kv line to ground (level 3) Case color Light Gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight Approx. 100 g 4

Life-test Curve 10,000 Switching operations (x 10 3 ) 5,000 1,000 500 100 30 VDC L/R = 7 ms 250 VAC (cosφ = 0.4) 250 VAC/30 VDC (cosφ = 1) Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 ma at 5 VDC (failure level: P). Load current (A) Connections Block Diagrams ON indicator OFF indicator Zero setting detection circuit Indicator circuit ROM RAM Clock Output circuit AC (DC) input Power supply circuit One-chip microcomputer Time range/unit selectors I/O Functions Inputs --- Outputs Control output Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob. Terminal Arrangement 8 8N 8-300 8N-300 N -300 N-300 (+)(~) Power supply Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. 5

Operation Timing Chart ton: ON set time toff: OFF set time Operating mode Flicker OFF start Timing chart 0.1 s min Power ON indicator ON OFF Lit Not lit toff ton toff ton toff toff OFF indicator Lit Not lit Flicker ON start Output NO ON OFF Output NC ON OFF Power ON indicator ON OFF Lit Not lit 0.1 s min. ton toff ton toff ton toff OFF indicator Lit Not lit Output NO ON OFF Output NC ON OFF Note: 1. The reset time requires a minimum of 0.1 s. 2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. Nomenclature OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. OFF-time unit display window OFF-time unit selector (select one from sec. 10 s, min., and hrs, or from 10 s, 10 min, hrs, and 10 h) Scale range display windows Time range selector (select one from 1.2, 3, 12, and 30 at full scale) For both ON-time and OFF-time. ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display window ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h) 6

Dimensions Note: All units are in millimeters unless otherwise indicated. N -300 N-300 48 17.4 5.7 6 66.6 52.3 0.7 48 37 dia. 14 dia. 44.8 44.8 R1.3 11 pins 8 8N 8-300 8N-300 48 48 37 dia. 17.4 5.7 6 66.6 52.3 0.7 44.8 44.8 14 dia. Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ R1.3 Dimensions with Back Connecting Socket P3G-08/P3GA-11 8 pins N 103.2* 100.9 8 8N 92.3* 90.0 81.5 81.5 17.4 17.4 80 75 N 8 8N P2CF-11 P2CF-11-E 2.3* P2CF-08 P2CF-08-E *These dimensions vary with the kind of DIN track (reference value). 2.3* Y92F-30 P3GA-11 (When Y92A-48G mounted) Y92F-30 P3G-08 (When Y92A-48G mounted) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 7

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2011.10 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2011 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: 8-300-AC100/240 8N AC100-240