PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Similar documents
SUBCON-PLUS-PROFIB...

PHOENIX CONTACT

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MINI MCR-SL-CVS NC

ETD-BL-1T-OFF-CC- 10S

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-MUX-V8-FLK 16

PHOENIX CONTACT - 05/2007

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MACX MCR-SL-(2)I-2)I-ILP(-SP)

MINI MCR-SL-PT100-UI-200

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

Redundancy Module QUINT-DIODE/40

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/...

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description

SUBCON 15 HD (High-density) D-Subminiature Connectors

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

PHOENIX CONTACT - 07/2006

Extract from the online catalog

MACX MCR-EX-SD LP(-SP)

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

onlinecomponents.com

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

QUINT-BUFFER/24DC/24DC/40

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Extract from the online catalog

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Installation manual plugs and connectors with screw connection (16/32 A)

Inductive sensor NI3-EG08K-Y1-H1341

PSR UC/ESAM4/3X1/1X2/B

PSR DC/ESP4/2X1/1X2

MACX MCR-EX-SL-RPSSI-I(-SP)

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

PHOENIX CONTACT - 02/2008

Operating instructions. Switching amplifier DN0210 DN / / 2015

MINI MCR-SL-PT100-UI(-SP)(-NC)

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual

FLEX Ex Spring Clamp Terminal Base

CPCI-PS24 24V-Power Supply

MACX MCR-EX-SL-RPSS-2I-2I

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

SolConeX extra-low voltage flange socket

PSI-MOS-PROFIB/FO 850 T

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

PHOENIX CONTACT Features

Inductive sensor BI1.5-EG08-Y1-H1341

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Inductive sensor BI5-EM18-Y1X-H1141

UTME 6. Extract from the online catalog. Order No.:

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

SolConeX Wall-Mounted Socket, 16 A

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

IB IL 24/48 DOR 2/W-XC-PAC

PHOENIX CONTACT - 10/2009

Bus Connector for PROFIBUS, 90

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

SUNCLIX Connection technology for photovoltaics

STEP-PS/1AC/24DC/1.75

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Operating instructions

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

TRIO-DIODE/12-24DC/2X10/1X20

QUINT-PS-3x AC/24DC/10

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Power supply unit NG3-16ib

Transcription:

Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in RS-485 fieldbus systems. Under field conditions, it enables the quick and easy connection of the incoming and outgoing bus line. The product range includes eleven fast connectors: Bus system Pin assignment D-SUB Cable entry Type Order No. Modbus, MODBUS-PLUS, BITBUS, Pin SUBCON-PLUS M 276826 ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET, 2, 3, 5, 6, 8 Socket SUBCON-PLUS F 2744267 SUCONET K, K2 (EATON/Moeller), Pin SUBCON-PLUS M2 276839 S-BUS (SAIA), J-BUS (Merlin Gerin) 2, 3, 4, 5, 7, 9 SUBCON-PLUS F2 2799490 Angled 35 CANopen, FIP 2, 3, 6, 7, 8, 9 SUBCON-PLUS F3 27687 Socket CAN, KEBA 2, 3, 4, 5, 6, 7 SUBCON-PLUS F4 2744089 Modbus, CEGELEC,, 2, 3, 6, 7 SUBCON-PLUS F5 274402 Universal type, 2, 3, 4, 5, 6, 7, 8, 9 Pin SUBCON-PLUS 9/M 274408 Socket SUBCON-PLUS 9/F 274424 Pin SUBCON-PLUS-M/AX9 2904467 Axial Socket SUBCON-PLUS-F/AX9 23797 WARNING: Explosion hazard when used in potentially explosive areas Follow the instructions provided here during installation. Always observe the safety notes. Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products.

Features Assembly under field conditions Separate terminal blocks for each cable High transmission speed For the angled connectors: cable entry is flexibly selectable Easy assembly thanks to knurled screws Variants Bus-specific types with matching partial assignment Universal type with full assignment Short mounting screw as an accessory when space is limited 2 Table of contents Description... 2 Table of contents...2 3 Ordering data...3 4 Safety regulations and installation notes...4 5 35 angled connector...5 6 Axial connectors...8 00287_en_02 PHOENIX CONTACT 2/9

3 Ordering data SUBCON-PLUS/... Type Order No. Pcs./Pkt. D-SUB connector, with two cable entries for Modbus, MODBUS-PLUS, BITBUS, ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET, pin assignment, 2, 3, 5, 6, 8 Angled 35, 9-pos., pin Angled 35, 9-pos., socket SUBCON-PLUS M SUBCON-PLUS F 276826 2744267 D-SUB connector, with two cable entries for SUCONET K, K2 (EATON/Moeller), S-BUS (Saia), J-BUS (Merlin Gerin), pin assignment 2, 3, 4, 5, 7, 9 Angled 35, 9-pos., pin Angled 35, 9-pos., socket SUBCON-PLUS M2 SUBCON-PLUS F2 276839 2799490 D-SUB connector, with two cable entries for CANopen, FIP, pin assignment 2, 3, 6, 7, 8, 9 Angled 35, 9-pos., socket SUBCON-PLUS F3 27687 D-SUB connector, with two cable entries for CAN, KEBA, pin assignment 2, 3, 4, 5, 6, 7 Angled 35, 9-pos., socket SUBCON-PLUS F4 2744089 D-SUB connector, with two cable entries for Modbus, CEGELEC, pin assignment,, 2, 3, 6, 7 Angled 35, 9-pos., socket SUBCON-PLUS F5 274402 D-SUB connector, with two cable entries, universal type, pin assignment, 2, 3, 4, 5, 6, 7, 8, 9 on every screw terminal block Angled 35, 9-pos., pin Angled 35, 9-pos., socket Axial, 9-pos., pin Axial, 9-pos., socket SUBCON-PLUS 9/M SUBCON-PLUS 9/F SUBCON-PLUS-M/AX9 SUBCON-PLUS-F/AX9 274408 274424 2904467 23797 Accessories Type Order No. Pcs./Pkt. Stripping pliers for PVC-insulated cables, QUICK-WIREFOX 6 204384 stripping range: 0.08 to 6 mm², can cut wires up to 6 mm² stranded and 4 mm² solid Optional mounting screw, without knurl for narrow installation SUBCON-SHORT-SCREW 2799694 conditions, slotted head, length: 40 mm, UNC 4-40 thread. Scope of supply: bag of 20 screws Screwdriver, slotted, VDE-insulated, size: 0.4 x 2.5 x 80 mm, 2-component handle, with non-slip grip SZS 0.4X2.5 VDE 205037 0 00287_en_02 PHOENIX CONTACT 3/9

4 Safety regulations and installation notes WARNING: Observe the following safety notes when using the connector. The category 3 device is designed for installation in Zone 2 potentially explosive areas. It meets the requirements of EN 60079-0:202+A:203 and EN 60079-5:200. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions as described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives) as well as general technical regulations must be observed. The safety data is provided in the packing slip and on the certificates (conformity assessment, additional approvals where applicable). Do not open or modify the device. Do not repair the device yourself; replace it with an equivalent device instead. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from non-compliance. The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. Do not subject the device to mechanical and/or thermal loads that exceed the specified limits. This device is not designed for use in atmospheres with a risk of dust explosions. The device must be stopped and immediately removed from the Ex area if it is damaged, was subjected to an impermissible load, stored incorrectly or if it malfunctions. 4. Installation in potentially explosive areas WARNING: Explosion hazard when used in potentially explosive areas Make sure that the following notes and instructions are observed. WARNING: Explosion hazard when used in potentially explosive areas D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. Observe the specified conditions for use in potentially explosive areas. The device should be installed so that a degree of protection of at least IP54 is achieved in accordance with EN 60529. To this end, a suitable, approved housing that meets the requirements of EN 60079-5 should be used. Only devices which are designed for operation in Ex zone 2 and are suitable for the conditions at the installation location may be connected to the circuits in zone 2. For safe operation, lockable plug connections must have a functional interlock (e.g. locking clip, screw connection etc.). Insert the interlock. Repair any damaged connectors immediately. In potentially explosive areas, only connect and disconnect cables when the power is disconnected. Connection to the D-SUB interface is only permitted if the screw connection is fully tightened. Temporary malfunctions (transients) must not exceed the rated voltage by more than 40 %. 00287_en_02 PHOENIX CONTACT 4/9

5 35 angled connector 5. Technical data SUBCON-PLUS M... SUBCON-PLUS F... SUBCON-PLUS 9/... Connection Connector connection 9-pos. D-SUB pin strip or D-SUB socket strip Interface connection Screw connection Cable entry 35, either left or right Connection cross section of screw terminal blocks Solid 0.4 mm 2....5 mm 2 (26-6 AWG) Stranded 0.4 mm 2... mm 2 (26-8 AWG) Insertion cycles >200 Cable diameter 8 mm (±2 mm) Mounting screws 4-40 UNC Maximum tightening torque 0.4 Nm General data Degree of protection IP20 Housing material ABS, metal-plated Nominal current I N 00 ma Max. operating voltage 50 V DC Ambient conditions Temperature range Operation -20 C...+75 C Storage/transport -25 C...+80 C Altitude 5000 m (for restrictions see manufacturer's declaration) Approvals ATEX II 3 G Ex na IIC T4 Gc X Please follow the special installation instructions in the documentation. 5.2 Dimensions 60 6 0 44 35 Figure Dimensions 00287_en_02 PHOENIX CONTACT 5/9

5.3 Structure 5.5 Stripping 50 60 5 6 Figure 4 Stripping 5 The following stripping tool is recommended: QUICK WIREFOX 6, Order No. 204384 4 2 NOTE: Malfunction Observe the specified stripping lengths. Figure 2 Structure 3 Strip the cable according to the specified stripping lengths. Fold back 0 mm of the braided shield over the outer sheath. Remove the aluminum foil. Upper housing part 2 D-SUB connection 3 Lower housing part 4 Strain relief 5 D-SUB mounting screws 6 Label 5.4 Opening the housing Figure 3 Opening the housing Release the housing cover using a screwdriver. Fold the housing upward to open. 00287_en_02 PHOENIX CONTACT 6/9

5.6 Connection Right-hand side cable entry WARNING: Explosion hazard when used in potentially explosive areas D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. Cable entry can be from the right or left side. The connector supplied is pre-assembled for left-hand side entry. Left-hand side cable entry Figure 6 Right-hand side cable entry Figure 5 Left-hand side cable entry Screw the stripped conductors into the corresponding connection block contacts: D-SUB contact = Screw connection D-SUB contact 2 = Screw connection 2... =... Lift the PCB out of the lower housing part using a screwdriver. Insert the PCB in the upper housing part. Screw the stripped conductors into the corresponding connection block contacts: D-SUB contact = Screw connection D-SUB contact 2 = Screw connection 2... =... 5.7 Strain relief Figure 7 Turn clip bracket For cable type A in accordance with EN 5070: Turn the clip bracket. Lay the shielding under the clip bracket of the strain relief. Screw it on. Close the housing and attach the label. 00287_en_02 PHOENIX CONTACT 7/9

6 Axial connectors 6. Technical data SUBCON-PLUS-M/AX9 2904467 SUBCON-PLUS-F/AX9 23797 Connection Connector connection 9-pos. D-SUB pin strip or D-SUB socket strip Interface connection Screw connection Cable entry Axial Connection cross section of screw terminal blocks Solid Stranded 0.4 mm 2... 0.5 mm 2 (26-20 AWG) 0.4 mm 2... 0.5 mm 2 (26-20 AWG) Insertion cycles >200 Cable diameter 8 mm (±0.4 mm) Mounting screws 4-40 UNC Maximum tightening torque 0.4 Nm Stripping length 4.5 mm General data Degree of protection IP20 Housing material ABS, metal-plated Nominal current I N 00 ma Max. operating voltage 50 V DC Ambient conditions Temperature range Operation Storage/transport -20 C... +75 C -25 C... +80 C Altitude 5000 m (for restrictions see manufacturer's declaration) Approvals ATEX II 3 G Ex na IIC T4 Gc X Please follow the special installation instructions in the documentation. 6.2 Dimensions 20 7 58,2 ON OFF 3,5 Figure 8 Dimensions 00287_en_02 PHOENIX CONTACT 8/9

6.3 Structure 6 6.4 Stripping The following stripping tool is recommended: QUICK WIREFOX 6, Order No. 204384 Strip off the conductors. Stripping length: 4.5 mm 6.5 Connection 5 2 3 WARNING: Explosion hazard when used in potentially explosive areas D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. 4 Figure 9 Structure Upper housing part 2 Connection block 3 D-SUB mounting screws 4 Lower housing part 5 Strain relief 6 Housing screws Figure 0 Connecting Loosen the housing screw. Lift off the top cover. Feed the cable into the housing. Screw the stripped conductors into the corresponding connection block contacts. D-SUB contact = Screw connection D-SUB contact 2 = Screw connection 2... =... Finally, close and screw tight the housing half shells. This creates the shield connection and the strain relief for the bus line. 00287_en_02 PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg Germany 9/9 phoenixcontact.com