CX1145 MFP - Firmware Updating with USB Storage Device

Similar documents
8.2 Firmware Updating with USB Device

T E C H N O L O G I E S. User Guide. 1:1 Duplicator (HDUSAS)

Instruction Sheet Updating SmartPAC 2 Firmware

AG-UX180/UX170 Firmware update procedure

AU-EVA1 Firmware update procedure

DUAL OS INSTALLATION

WipeDrive Home 9. IMPORTANT! PLEASE READ CAREFULLY:... 3 General Information... 3 WipeDrive Overview... 3 System Requirements...

Maxxyz Compact Operating System Installation

DVD Duplication Towers

How to Update NN3D to v2.07 (Combo Update) MFDBB

1. Install Programmer Software

Note: If QT is not installed you get the following error and the file is still not saved:

Getting Started. Here's how to get started using your Zip 250 drive: 1. Unpack the Zip 250 drive and accessories.

If possible before restoring a RipNAS copy the music files (and other personal data) to an external drive.

INSTALLING THE PS3 XBOX READY SOFTWARE:

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

March Getting Started with the Intel Desktop Board DQ77MK UEFI Development Kit

SECUDRIVE Sanitizer Portable User Guide

Installing Your Multifunction to Your Network for the First Time -USB Cable Method

System Firmware Update Instructions for AVH-X8550BT/RC series

T E C H N O L O G I E S. User Guide. 1:5 Duplicator (HDU5SAS)

CPR Flash Firmware Update Utility For CPR Tools Devices

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

Taurus Mini Super-S LCM

USB Memory Device Troubleshooting. A Test Procedure to Determine if the USB Memory Device is Operating Properly

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

Microsoft File Allocation Table

Owner s Manual Version 1.0e

Installation of Lubuntu Linux, Koha, DSpace and other software using LibLiveCD

8/16/32-Ch Network Video Recorder NVR Series

How to setup and schedule backup to iscsi storage in Linux NVR

ATOLA INSIGHT. A New Standard in Data Recovery Technology. Manages All 4 Stages of Data Recovery. 1 Hard Drive Diagnosis

Disk Imaging with Knoppix

Firmware Updater for COOLSCAN IV ED

INSTRUCTIONS TO UPDATE FIRMWARE FOR / / Dranetz New Durham Road, Edison, New Jersey Telephone or

Firmware Update Procedure for RX-Z7

How to Dual-Boot OS X and Ubuntu

USER MANUAL TROUBLESHOOTING V

Image rescue Quick Start Guide

How to Use imageprograf Firmware Update Tool (Version or later) (Mac OS) Canon Inc.

USB2.0 LAN DISK User s Manual

ATOLA INSIGHT ETHERNET

AG-AC160 series Software (Firmware) update procedure

IRONKEY D300S SECURE USB 3.0 FLASH DRIVE

User. Applications. Operating System. Hardware

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

10/100Mbps 2Port USB2.0 MFP Server

Lab Install Windows 8

JDM Installation Guide

ACT-HDC15SPD 1 to 5 HDD Duplicator. User s Manual. Ver: 1.00 ACT

Dvisto. User Manual. The Ultimate Portable On-the-Go Digital Camera Backup Storage! Version 1.0

2015. All right reserved

Peerless Drive System User's Manual

Magic Card User Manual

Media-Mirror Media-Mirror-Plus Backup System. User s Manual

T E C H N O L O G I E S ENT ESC. User Guide. 1:5 HDD Duplicator Deluxe (HDUS5325DX)

XL-RAID-213SA User Manual

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

1. Version Information

Upgrading Software and Firmware

ROM Write Utility. Operating Instructions

MS6174 Data Adaptor (USB type) Software Manual

DELLEMC. TUESDAY September 19 th 4:00PM (GMT) & 10:00AM (CST) Webinar Series Episode Nine WELCOME TO OUR ONLINE EVENTS ONLINE EVENTS

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Cruzer flash drive NOT detected by Windows PC

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2

Instructions to update Digimax application software (a.k.a. firmware)

Que! USB Floppy Disk Drive Installation Guide

ReadyNAS OS 6 Desktop Storage Systems

Pleiades - NDAS. User Manual. External Storage Enclosure for 3.5 IDE Hard Drives. v1.2

Longshine Technologie Europe GmbH

Procedures to Install Eye Com's ImageMouse and ImageMouse Plus using Windows XP platform

M3099G\GX\GH\Fi-4860C\M4099D\Fi-4990C WinNT Installation Procedure

Vvisto. User Manual. & Installation Guide. USB 2.0 Hard Drive with Multi Card Reader, featuring easy file backup!

Media Maven Media Maven Plus DVD/CD Duplicator

iclicker Base Firmware Utility v1.0.3 User Guide November 2018

User Guide 1:11 HDD Duplicator NB (HDUS11NB)

OpenDRO User s Guide (rev. 2) SHUMATECH. DRO-550 Software Upgrade Guide

How to boot Mac OS X 10.5 from RocketRAID esata for Mac

Mytek FW DIO Card User Manual

Firmware Updating Tool for USB Card Reader. Firmware Updater. User s Manual. For Windows XP, XP x64, 2000 CAUTION

Blu-ray/DVD/CD Duplicator. User Guide V5.40

T E C H N O L O G I E S ENT ESC. User Guide. 1:4 CF or CFAST Duplicator PRO (CFASTD4-2S / CFD4-2S)

ARS-2030T/2033/2033P/ 2033S/2039 PCI-Based Copy Controller

HD MAX Hard Disk Drive Duplicator. User s Manual

K9 Series Firmware Update Guide

SERVICE MANUAL FIELD SERVICE

Flex Focus 1202 Software Installation Procedure

M9-LAN. User Manual. & Installation Guide. Network Drive for 3.5 IDE HDD. v1.1

DAT Optic Inc Universal FireWire Enclosure User s Manual Rev 1.0

Contents. 1 Drobo 5C Online User Guide Before You Begin Product Features at a Glance Checking Box Contents...

User s Manual. Rev July 29,

Reinstalling the Operating System on the Dell PowerVault 745N

Introduction. Tools required: This type of box contains general notes or tips for all systems

HOW TO: Upgrade Windows XP to Windows 7 with Windows Easy Transfer

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

OS Installer. Installation Instructions

SATA DVD/CD Duplicator Controller User s Manual

TECH NOTE VICON TECHNICAL SERVICES GROUP

1:5 Combo msata HDD Duplicator (MSHDUS5HS)

Transcription:

CX1145 MFP - Firmware Updating with USB Storage Device In this equipment, it is recommended to update the firmware by connecting the USB storage device on which the firmware data is written to the USB connector mounted on the system control PC board and turning ON the power. The type of firmware to be updated can be selected on the LCD screen in this method. This allows update of the necessary firmware individually or to update all firmware in a batch. The type of firmware which can be updated with this method are as follows in the table below. Firmware Stored Model specific folder name Data file name Master data Hard disk 1, 2, 3... n * The file name should be consecutive numbers from 1 to n without file extension. The capacity of each file is approx. 8 MB. However, the file capacity of n (last number) may be less than 8 MB. System ROM System control PC board firmimage0.bin, firmimage1.bin (SYS board) * The system firmware is stored into the hard disk from the FROM basic section software version V1.01/2.30. Engine ROM Logic PC board (LGC board) firmimage2.bin Scanner ROM Scanning section control PC board (SLG board) Note: When the HDD is replaced it is necessary to format a partition in the HDD before downloading. For procedure to format a partition see item # 3 in the appendix on page 8.

Update Program The firmware can be updated to the latest version without considering the current one by storing the update program together with the firmware data file for updating in the USB Storage Device. Name File name Stored Tool object for updating mentusb.o root Update program dlfirmware_28_1145 [CX_1145] folder (Model specific folder) USB Storage Device mentusb.o 28_1145 dlfirmware_28_1145 firmimage0.bin firmimage1.bin firmimage2.bin 1 2 3 : 2

Update Procedure (1) Shut down thecx1145. (2) Take off the USB cover USB Cover (3) Connect the USB storage device to the USB connector (host) on the SYS board. USB storage device USB connector (host) 3

(4) Hold down the [4] button and [9] button simultaneously and turn ON the power When the update program is used, the following screen appears. Download USB Maintenance Module After the update program is finished being loaded, the following screen appears. Download Storage Update Mode Please wait.now Initialization DlFirmWare Version VX.XX Notes: Note: If the file of the update program is not stored in the USB storage device or the loading of the update program fails, the following screen appears. In this case, check if the update program is correctly stored and repeat step (4) and after. Error loadmodule If the USB storage device is not recognized properly, the following message is displayed. In this case, disconnect the USB storage device and connect it again within 3 minutes, or turn OFF the power of the equipment and connect the device properly. Then repeat the procedure. Please Set Correct USB Storage Device If the updating data file does not exist or a data file for another model is stored, the following message is displayed. In this case, turn OFF the power of the equipment and confirm if the data file stored in the USB storage device is correct. Then repeat the procedure. WARNING ROMDATA MISMATCH!!! ROMDATA Version is V***.***.* Please REBOOT to use CORRECT ROMDATA If you still want to continue, Please push Start Key If an attempt is made to update the latest firmware version without the update program, the following screen appears. Inflate Error Please Change USB Storage or Please Check ROMDATA 4

(5) Check the items to be updated. The screen for selecting the items to be updated is displayed after 3 minutes. * is displayed next to the items to be updated. Download Storage Firmware Update Mode Select Update Item Version in update media *1. OS UI Update UIF Version..VXXX.XXX.X *2. HDD SYS Update UI0 Version..VXXX.XXX.X *3. Engine Firmware Update UI1 Version..VXXX.XXX.X *4. Scanner Firmware Update SYS Version..VXXX.XXX.X ENG Version..VXXX.XXX.X SCN Version..VXXX.XXX.X Select the item with the digital keys. * is displayed next to the selected item. Display or delete the * by pressing the number of the item. All items are selected in the default settings. Select all items to update the firmware of the equipment in a batch. Select items as follows to update individually. System ROM (OS data) System ROM (UI data) Master data System ROM (System firmware) Engine ROM Scanner ROM 0. OS Update 2. UI Data Update 1. HDD Update 3. System Firmware Update 4. Engine Firmware Update 5. Scanner Firmware Update (Updating all the items is taken as an example and explained in the following procedures.) () Press the [START] button. Updating starts and the processing status is displayed on the LCD screen. Download Storage Firmware Update Mode Download Board FROM Update Start OS UI Update Check Devices Completed HDD SYS Update Update Status Installing Engine MAIN Update.. Flash Update Data Check Scanner Firm Update. Flash Update Download Storage HDD copying 1/n Engine Update Status xxxx/nnnn Scanner Update Status xxxx/nnnn 5

Status display during update OS Update... HD Data Update... UI Data Update... SysFirm Update... Engine MAIN Update...Flash Update Scanner Firm Update... Flash Update Status display when update is completed OS Update... Completed HD Data Update... Completed UI Data Update...Completed SysFirm Update...Completed Engine MAIN Update... Completed Scanner Firm Update... Completed Update Completed. is displayed at the bottom of the LCD screen after the updating is completed properly. Download Storage Firmware Update Mode OS Update.Completed HD Data Update Completed UI Data Update. Completed SysFirm Update Completed Engine MAIN Update...Completed Scanner Firm Update... Completed Update Completed (7) Turn OFF the power, remove the USB storage device and install the cover plate. (8) Perform the initialization of the updated data. Note: Hold down the [0] button and [8] button simultaneously and turn ON the power Key in 947, and then press the [START] button. Press the [INITIALIZE] button. Update Failed. is displayed at the bottom of the LCD screen when updating is not completed properly. Failed appears next to the failed item on the status display. Turn OFF the power, and then check the following items. After confirming and clearing the problems, restart updating from the beginning. Does the USB storage device meet the conditions to be used for updating Is the data file written properly on the USB storage device? Is the USB storage device installed properly? Do the USB storage device and equipment operate properly? Download Storage Firmware Update Mode OS Update.Completed HD Data Update Completed UI Data Update Completed SysFirm Update... Completed Engine MAIN Update.. Failed Scanner Firm Update.. Completed Update Failed

(9) Confirmation of the Updated Data After the update is completed, check each data version in the Setting Mode (08) to confirm that the data was overwritten properly. <Updating Master data> 08-924: Version of UI data language 1 in HDD 08-925: Version of UI data language 2 in HDD 08-92: Version of UI data language 3 in HDD 08-927: Version of UI data language 4 in HDD 08-928: Version of UI data language 5 in HDD 08-929: Version of UI data language in HDD 08-931: Version of UI data language 7 in HDD 08-933: HDD unit data version 08-934: Version of Web UI data language 1 in HDD 08-935: Version of Web UI data language 2 in HDD 08-93: Version of Web UI data language 3 in HDD 08-937: Version of Web UI data language 4 in HDD 08-938: Version of Web UI data language 5 in HDD 08-939: Version of Web UI data language in HDD <Updating System ROM> 08-900: System ROM version 08-922: UI data fixed section version 08-923: UI data common section version 08-930: Version of UI data in FROM displayed at power ON <Updating Engine ROM> 08-903: Engine ROM version <Updating Scanner ROM> 08-905: Scanner ROM version 7

Appendix [A] Assist Mode This equipment has an Assist Mode to enable the following functions. (1) NVRAM flag clearing ( Clear NVRAM flags. ) Even if the firmware downloading has been completed normally, the Recovery Mode may accidentally start up when the power is turned ON again. In this case, clear the NVRAM flags used in the download process with this function. (Normally, the flags are automatically cleared in the download process.) Also in the case the Recovery Mode accidentally starts up after the replacement of NVRAM on the SYS board, the flags are cleared with this function. (2) Data storage partition formatting ( Format Loader Partition. ) When a defection occurs on the UI data, etc. which are stored in the HDD, the partition with the stored UI data, etc. is formatted with this function. (Do not use this function since it is not normally necessary.) (3) HDD partition creation ( All Partition Delete and Create Loader Partition. ) When the HDD is replaced or UI data, etc. are downloaded using the USB storage, it is necessary to format a partition in the HDD before downloading. In this case, the partition is created in the HDD with this function. Note: Perform the HDD partition formatting only when a new HDD and scrambler board are installed since all data in the current HDD are erased by this operation. [B] Operating Procedure of Assist Mode (1) Hold down the [3] button and [CLEAR] button simultaneously and turn ON the power The following screen is displayed. Firmware Version Up Mode Select Number (1-3) and Press Start Key > 1. Clear NVRAM Flags 2. Format Loader Partition 3. All Partition Delete and Create Loader Partition (2) Select the item with the digital keys and press the [START] button. 8