Project Consideration of Commission Directives in Order No. 693

Similar documents
Standards Authorization Request Form

Standards Authorization Request Justification

TOP-010-1(i) Real-time Reliability Monitoring and Analysis Capabilities

primary Control Center, for the exchange of Real-time data with its Balancing

Concept White Paper. Concepts for Proposed Content of Eventual Standard(s) for Project : Real-Time Monitoring and Analysis Capabilities

November 9, Revisions to the Violation Risk Factors for Reliability Standards IRO and TOP

TOP/IRO Standards. RC Users Group January 21, Vic Howell Manager, Operations Engineering Support

Reliability Coordinator Procedure PURPOSE... 1

Standard TOP Transmission Operations

5. Effective Date: The first day of the first calendar quarter after applicable regulatory approval.

Standard CIP Cyber Security Critical Cyber As s et Identification

Standard Authorization Request Form

Standards Authorization Request Form

TOP for Transmission Operators

Standard CIP Cyber Security Critical Cyber As s et Identification

Québec Reliability Standards Compliance Monitoring and Enforcement Program Implementation Plan Annual Implementation Plan

British Columbia Utilities Commission Reliability Standards with Effective Dates adopted in British Columbia

Proposed Convention for Numbering of NERC Reliability Standards Draft September 9, 2004

New Brunswick 2018 Annual Implementation Plan Version 1

Consideration of Issues and Directives Project Modeling Data (MOD B) October 7, 2013

requirements in a NERC or Regional Reliability Standard.

Standard Development Timeline

Southwest Power Pool Independent Coordinator of Transmission RELIABILITY PLAN for Entergy in the Southeastern Electric Reliability Council September

Peak Reliability Coordination Services in the West March 30, 2018

Path Operations post WECC TOP 007 Rob Witham, WAPA RMR TSS Supervisor

Disclaimer Executive Summary Introduction Overall Application of Attachment Generation Transmission...

Unofficial Comment Form 1st Draft of PRC-005-3: Protection System and Automatic Reclosing Maintenance (Project )

Standard CIP Cyber Security Electronic Security Perimeter(s)

PRC Coordination of Protection Systems for Performance During Faults

Draft CIP Standards Version 5

Implementation Plan for COM-001-2

Unofficial Comment Form Project Real-time Monitoring and Analysis Capabilities IRO and TOP-010-1

TOP-001 v3 and v4 Monitoring Non-BES and Data Exchange Requirements. FRCC Spring RE Workshop April 17-18, 2018

Standard Development Timeline

Supplemental Information

Modifications to TOP and IRO Standards

Reliability Standard Audit Worksheet 1

Purpose. ERO Enterprise-Endorsed Implementation Guidance

Unofficial Comment Form Project Disturbance Monitoring

Standard INT Dynamic Transfers

A. Introduction. B. Requirements and Measures

Standard Development Timeline

Disturbance Monitoring and

Peak Reliability. Reliability Coordinator Data Request and Specifications for Data Provision

NERC Management Response to the Questions of the NERC Board of Trustees on Reliability Standard COM September 6, 2013

Standard INT Dynamic Transfers

COM Communications and Coordination

Project Posting 8 Frequently Asked Questions Guide

Meeting- Overview of. Development

Guidelines for Submitting NERC Reliability Standards Required Documents to the SPP Reliability Coordinator and the SPP Balancing Authority Version 1

Unofficial Comment Form Project Operating Personnel Communications Protocols COM Operating Personnel Communications Protocols

NERC Event Analysis Update Webinar. Hassan Hamdar Chair, Event Analysis Subcommittee October 20, 2016

Reliability Coordinator Procedure

SOUTH TEXAS ELECTRIC COOPERATIVE, INC.

Reliability Standard Audit Worksheet 1

Standard Authorization Request Form

ERO Enterprise Registration Practice Guide: Distribution Provider directly connected Determinations Version 2: July 5, 2018

Standard CIP 005 2a Cyber Security Electronic Security Perimeter(s)

Standard CIP Cyber Security Security Management Controls

Standard Development Timeline

CIP Cyber Security Critical Cyber Asset Identification. Rationale and Implementation Reference Document

This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective.

CIP Cyber Security Personnel & Training

NERC Relay Loadability Standard Reliability Standards Webinar November 23, 2010

This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective.

Unofficial Comment Form Project Operating Personnel Communications Protocols COM-002-4

Enhanced Curtailment Calculator Update

Proposal for Development and Use of Node- Breaker Topology Representations for Offline and Real-time Study Models November 12, 2013

Consideration of Issues and Directives Federal Energy Regulatory Commission Order No. 791 June 2, 2014

CIP Cyber Security Personnel & Training

Table of Contents. TOP TOP BA Data Request and Specification Guidelines. Operating Procedure

REAL-TIME MONITORING DATA SPECIFICATION

BC Hydro Open Access Transmission Tariff Effective: January 26, 2018 OATT Attachment Q-1 First Revision of Page 1

151 FERC 61,066 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION ORDER DENYING REHEARING. (Issued April 23, 2015)

Project Retirement of Reliability Standard Requirements

Comment Form for 1 st Draft of Standard for Backup Facilities (Project )

DRAFT. Cyber Security Communications between Control Centers. March May Technical Rationale and Justification for Reliability Standard CIP-012-1

Standard CIP Cyber Security Critical Cyber Asset Identification

NERC and Regional Coordination Update. Operating Committee Preston Walker January 9, 2018

NERC CIP Information Protection

Standard CIP Cyber Security Critical Cyber Asset Identification

This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective.

Standard EOP Disturbance Reporting

Implementation Plan for Newly Identified Critical Cyber Assets and Newly Registered Entities

Categorizing Cyber Systems

A. Introduction 1. Title: 2. Number: 3. Purpose: 4. Applicability: 4.1. Functional Entities: Balancing Authority Distribution Provider

Standard Development Timeline

NERC and Regional Coordination Update

2017 MRO Performance Areas and an Update on Inherent Risk Assessments

Date adopted/approved 02/08/2013 Custodian (entity responsible for maintenance and upkeep) Data Exchange Work Group. Web URL: Previous name/number

Project Modifications to BAL Frequency Response and Frequency Bias Setting. Industry Webinar December 18, 2018

Standard CIP 005 4a Cyber Security Electronic Security Perimeter(s)

Title. Critical Infrastructure Protection Getting Low with a Touch of Medium. CanWEA Operations and Maintenance Summit 2018.

Violation Risk Factor and Violation Severity Level Justification Project Modifications to CIP-008 Cyber Security Incident Reporting

Standard CIP Cyber Security Physical Security

COM Operating Personnel Communications Protocols. October 31, 2013

Project Cyber Security - Order No. 791 Identify, Assess, and Correct; Low Impact; Transient Devices; and Communication Networks Directives

Summary of FERC Order No. 791

NB Appendix CIP NB-0 - Cyber Security Recovery Plans for BES Cyber Systems

DRAFT Reliability Standard Audit Worksheet 1

Transcription:

Project 2009-02 Consideration of Commission Directives in Order Order P 905-906 Further, consistent with the NOPR, the Commission directs the ERO to modify IRO-002-1 to require a minimum set of tools that must be made available to the reliability coordinator. We believe this requirement will ensure that a reliability coordinator has the tools it needs to perform its functions. [t]he Commission clarifies that the Commission s intent is to have the ERO develop a requirement that identifies capabilities, not actual tools or products. The Commission agrees that the latter approach is not appropriate as a particular product could become obsolete and technology improves over time. Proposed IRO-018-1 addresses issues identified by the NERC Operating Committee's Real-time Tools Best Practices Task Force (RTBPTF) related to the availability and quality of the Reliability Coordinator's (RC) monitoring and analysis capabilities. The monitoring and analysis capabilities required by proposed IRO-018-1 and other IRO standards discussed below ensure RCs have the capabilities to maintain Real-time situational awareness. Monitoring Capabilities Requirement R1 addresses the quality of the Real-time data needed by the RC to perform its monitoring and Real-time Assessments. Each RC is required to implement a documented procedure for addressing Real-time data quality issues. The procedure must include criteria for evaluating Real-time data quality, provisions for indicating data quality to the System Operator, and actions to resolve Real-time data quality issues when data quality affects Real-time Assessments. Requirement R3 addresses capabilities for operator awareness of failures in Real-time monitoring alarm processes by requiring RCs to use an alarm process monitor. Requirements for the RC to perform Real-time monitoring are specified in IRO-002-2, IRO-002-4, and IRO-003-2. Proposed IRO-018-1 R1. Each Reliability Coordinator shall implement an Operating Process or Operating Procedure to address the quality of the Real-time data necessary to perform its Real-time 1

monitoring and Real-time Assessments. The Operating Process or Operating Procedure shall include: 1.1. Criteria for evaluating the quality of Real-time data; 1.2. Provisions to indicate the quality of Real-time data to the System Operator; and 1.3. Actions to resolve Real-time data quality issues with the entity(ies) responsible for providing the data when data quality affects Real-time Assessments. R3. Each Reliability Coordinator shall have an alarm process monitor that provides notification(s) to its System Operators when a failure of its Real-time monitoring alarm processor has occurred. IRO-002-2 R5. Each Reliability Coordinator shall monitor Bulk Electric System elements (generators, transmission lines, buses, transformers, breakers, etc.) that could result in SOL or IROL violations within its Reliability Coordinator Area. Each Reliability Coordinator shall monitor both real and reactive power system flows, and operating reserves, and the status of Bulk Electric System elements that are or could be critical to SOLs and IROLs and system restoration requirements within its Reliability Coordinator Area. IRO-003-2 R1. Each Reliability Coordinator shall monitor all Bulk Electric System facilities, which may include sub-transmission information, within its Reliability Coordinator Area and adjacent Reliability Coordinator Areas, as necessary to ensure that, at any time, regardless of prior planned or 2

unplanned events, the Reliability Coordinator is able to determine any potential System Operating Limit and Interconnection Reliability Operating Limit violations within its Reliability Coordinator Area. IRO-002-4 R3. Each Reliability Coordinator shall monitor Facilities, the status of Special Protection Systems, and non-bes facilities identified as necessary by the Reliability Coordinator, within its Reliability Coordinator Area and neighboring Reliability Coordinator Areas to identify any System Operating Limit exceedances and to determine any Interconnection Reliability Operating Limit exceedances within its Reliability Coordinator Area. 3 Analysis Capabilities Requirement R2 addresses the quality of the analysis used by the RC to perform its Real-time Assessments. Each RC is required to implement a documented procedure to address the quality of the analysis used in its Real-time Assessments. The procedure must include criteria for evaluating the quality of analysis used in Real-time Assessments, provisions for indicating the quality of analysis, and actions to resolve analysis quality issues affecting its Real-time Assessments.. Requirements for the RC to perform Real-time Assessments are specified in IRO-008-1 and IRO-008-2. Proposed IRO-018-1 R2. Each Reliability Coordinator shall implement an Operating Process or Operating Procedure to address the quality of analysis used in its Real-time Assessments. The Operating Process or Operating Procedure shall include:

2.1. Criteria for evaluating the quality of analysis used in its Real-time Assessments; 2.2 Provisions to indicate the quality of analysis used in its Real-time Assessments; and 2.3. Actions to resolve analysis quality issues affecting its Real-time Assessments. IRO-008-1 R2. Each Reliability Coordinator shall perform a Real-Time Assessment at least once every 30 minutes to determine if its Wide Area is exceeding any IROLs or is expected to exceed any IROLs. Definition of Real-time Assessment An evaluation of system conditions using Real-time data to assess existing (pre-contingency) and potential (post- Contingency) operating conditions. The assessment shall reflect applicable inputs including, but not limited to: load, generation output levels, known Protection System and Special Protection System status or degradation, Transmission outages, generator outages, Interchange, Facility Ratings, and identified phase angle and equipment limitations. (Real-time Assessment may be provided through internal systems or through third-party services.) IRO-008-2 R4. Each Reliability Coordinator shall ensure that a Real-time Assessment is performed at least once every 30 minutes. 4

P 1660 We adopt our proposal to require the ERO to develop a modification [to TOP standards] related to the provision of a minimum set of analytical tools. In response to LPPC and others, we note that our intent was not to identify specific sets of tools, but rather the minimum capabilities that are necessary to enable operators to deal with real-time situations and to ensure reliable operation of the Bulk-Power System. Proposed TOP-010-1 addresses issues identified by the NERC Operating Committee's Real-time Tools Best Practices Task Force (RTBPTF) related to the availability and quality of the monitoring and analysis capabilities used by Transmission Operators (TOPs) and Balancing Authorities (BAs). The monitoring and analysis capabilities required by TOP-010-1 and other TOP standards discussed below ensure TOPs and BAs have the capabilities to maintain Real-time situational awareness. Monitoring Capabilities Requirements R1 and R2 address the quality of the Real-time data needed by TOPs and BAs to perform their Real-time monitoring and Real-time analysis. Each TOP and BA is required to implement a documented procedure for addressing Realtime data quality issues. The procedure must include criteria for evaluating Real-time data quality, provisions for indicating data quality to the System Operator, and actions to resolve Real-time data quality issues when data quality affects analysis. Requirement R4 addresses capabilities for operator awareness of failures in Real-time monitoring alarm processes by requiring TOPs and BAs to use an alarm process monitor. Requirements for TOPs to perform Real-time monitoring are specified in TOP-001-3 and TOP-006-2. Requirements for BAs to perform Real-time monitoring are specified in TOP-006-2, TOP-001-3k and BAL standards. Proposed TOP-010-1 R1. Each Transmission Operator shall implement an Operating Process or Operating Procedure to address the quality of the Real-time data necessary to perform its Real-time 5

monitoring and Real-time Assessments. The Operating Process or Operating Procedure shall include: 1.1. Criteria for evaluating the quality of Real-time data; 1.2. Provisions to indicate the quality of Real-time data to the System Operator; and 1.3. Actions to resolve Real-time data quality issues with the entity(ies) responsible for providing the data when data quality affects Real-time Assessments. R2. Each Balancing Authority shall implement an Operating Process or Operating Procedure to address the quality of the Real-time data necessary to perform its analysis functions and Real-time monitoring. The Operating Process or Operating Procedure shall include: 2.1 Criteria for evaluating the quality of Real-time data; 2.2 Provisions to indicate the quality of Real-time data to the System Operator; and 2.3 Actions to coordinate resolution of Real-time data quality discrepancies with the entity(ies) responsible for providing the data. 6 R4. Each Transmission Operator and Balancing Authority shall have an alarm process monitor that provides notification(s) to its System Operators when a failure of its Real-time monitoring alarm processor has occurred. TOP-006-2 R1. Each Transmission Operator and Balancing Authority shall know the status of all generation and transmission resources available for use.

1.1. - Each Generator Operator shall inform its Host Balancing Authority and the Transmission Operator of all generation resources available for use. 1.2. - Each Transmission Operator and Balancing Authority shall inform the Reliability Coordinator and other affected Balancing Authorities and Transmission Operators of all generation and transmission resources available for use. TOP-001-3 R10. Each Transmission Operator shall perform the following as necessary for determining System Operating Limit (SOL) exceedances within its Transmission Operator Area: 10.1. Within its Transmission Operator Area, monitor Facilities and the status of Special Protection Systems, and 10.2. Outside its Transmission Operator Area, obtain and utilize status, voltages, and flow data for Facilities and the status of Special Protection Systems. R11. Each Balancing Authority shall monitor its Balancing Authority Area, including the status of Special Protection Systems that impact generation or Load, in order to maintain generation-load-interchange balance within its Balancing Authority Area and support Interconnection frequency. 7 Analysis Capabilities Requirement R3 addresses the quality of the analysis used by the TOP to perform its Real-time Assessments. Each TOP is required to implement a documented procedure to address the quality of the analysis used in its Real-time Assessments. The procedure must include criteria for evaluating the quality of

8 analysis used in Real-time Assessments, provisions for indicating the quality of analysis, and actions to resolve analysis quality issues affecting its Real-time Assessments. Requirements for the TOP to perform Real-time Assessments are specified in TOP-003-3. Proposed TOP-010-1 R3. Each Transmission Operator shall implement an Operating Process or Operating Procedure to address the quality of analysis used in its Real-time Assessments. The Operating Process or Operating Procedure shall include: 3.1. Criteria for evaluating the quality of any analysis used in its Real-time Assessments; 3.2. Provisions to indicate the quality of analysis used in its Real-time Assessments; and 3.3. Actions to resolve analysis quality issues affecting its Real-time Assessments. Definition of Real-time Assessment An evaluation of system conditions using Real-time data to assess existing (pre-contingency) and potential (post- Contingency) operating conditions. The assessment shall reflect applicable inputs including, but not limited to: load, generation output levels, known Protection System and Special Protection System status or degradation, Transmission outages, generator outages, Interchange, Facility Ratings, and identified phase angle and equipment limitations. (Real-time Assessment may be provided through internal systems or through third-party services.) TOP-001-3 R13. Each Transmission Operator shall ensure that a Real-time Assessment is performed at least once every 30 minutes.

P 1875...[w]e direct the ERO, through its Reliability Standards development process, to modify Reliability Standard VAR-001-1 to include requirements to perform voltage stability analysis periodically, using online techniques where commerciallyavailable, and offline simulation tools where online tools are not available, to assist real-time operations. The directive was considered in developing the scope of Project 2009-02. NERC believes TOP, IRO, and VAR standards address the directive as discussed below. Accordingly, additional requirements were not developed in Project 2009-02. RCs and TOPs are required to periodically perform Real-time Assessments consisting of an evaluation of system conditions "to assess existing (pre-contingency) and potential (post- Contingency) operating conditions." Entities must use whatever analysis is necessary to obtain an evaluation of system conditions, which may include real-time voltage stability analysis. Real-time Assessments assist operators in maintaining operations within established SOLs and IROLs, to include voltage stability criteria. Requirements for performing Real-time Assessments are contained in IRO-008-1, IRO-008-2, and TOP-001-3 Reliability Standards as discussed above. VAR-001-1 was revised in Project 2013-04. The resulting standard, VAR-001-4, did not include an explicit requirement for periodic performance of voltage stability analysis because "such analysis would be performed pursuant to the SOL methodology developed under FAC standards." 1 VAR-001-4 requirement R1 specifies the TOP must establish a system voltage schedule as part of its plan to operate within SOLs and IROLs. VAR-001-4 R1. Each Transmission Operator shall specify a system voltage schedule (which is either a range or a target value with an associated tolerance band) as part of its plan to operate 1 Reliability Standard VAR-001-4.1, Guidelines and Technical Basis section, page 13. Available at: http://www.nerc.com/pa/stand/reliability%20standards/var-001-4.1.pdf 9

within System Operating Limits and Interconnection Reliability Operating Limits. 1.1. Each Transmission Operator shall provide a copy of the voltage schedules (which is either a range or a target value with an associated tolerance band) to its Reliability Coordinator and adjacent Transmission Operators within 30 calendar days of a request. 10