Instructions Order No. 3ZX1812-0WN60-0AC0 /

Similar documents
SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

I/O module (Expansion module)

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

EMMS-T A00 SIERS. Siemens integrated electrical racking system instruction manual. usa.siemens.com/mvswitchgear

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

AS-Interface Kompaktstarter Compact Starter

SACE Emax 2 Specification guide

C E R T I F I C A T E O F C O M P L I A N C E

ST (6ES7132-6FD00-0BB1)

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Voltage Sag Simulator

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

SIMATIC S7-300 Programmable Controller Getting Started Edition 04/2000 First Steps for Installation and Commissioning Totally Integrated Automation

1 INTRODUCTION Contents of this manual Explanation of terms and advantages of "communication" 4

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

CDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Air Circuit Breakers. 1/2 Introduction

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

SENTRON 3VL Molded Case Circuit Breakers

SENTRON communication manual. sentron. User manual for communication capable SENTRON WL and VL circuit breaker '5$)7

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Voltage Dip-Proofing Inverter

Earth-fault Relay SPAJ 110 C. Product Guide

Applikationen & Tools. Safe switching of IO-Link motor starter combination 3RA27 with safety relay 3SK1. IO-Link. FAQ November 2012

Safety Relays 3TK2845 Multifunction Device

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

The Intelligent Simplicity. Sentron 3WL Air Circuit Breaker. Answers for industry.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Common Departures Interconnecting Facilities Requirements

SENTRON Switching and Protection Devices Air Circuit Breakers

Voltage Dip-Proofing Inverter

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Electrical Demand Specification (Reference SOP: )

VAMP 221. Table of Contents

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Feeder protection relay SPAA 341 C. Product Guide

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

TG basic 1. Appliance tester for testing protective measures in accordance with DIN VDE (DIN EN 62638)

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

ACCESSORIES FOR MO OVERVIEW

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

Miniature circuit-breaker versus electronic selectivity module Selective monitoring of 24 V DC load circuits

Quick Start Guide TS A

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

Type VR Electrically Operated Ground and Test Device

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Digital output module. DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) SIMATIC

NW08 to NW63 fixed circuit breakers Circuit breakers

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Solid State Remote Power Controller E /627

Applications & Tools. Safe switching of the motor starters 3RM10 and 3RM12. SIRIUS Safety. FAQ February Answers for industry.

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

Installation, Operation and Maintenance Manual

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

ADDENDUM FOR 20, 27, & 28 OPTIONS

EATON 5S 850/1200/1600

MU110-6U. Analog output module 6 channel. User guide

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

DEEP SEA ELECTRONICS PLC

Feeder protection relay

Redundancy unit CP-A RU

powerful ideas RELIABLE SOLUTIONS ANSI / UL1066 & UL 489 WL Low Voltage Power Circuit Breaker WL Trip Unit, MODBUS Communication

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Ground Fault Protection. Instruction Manual

PHASE MONITOR RELAYS Product Summary

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Transcription:

as copy and fax form Instructions Order. 3ZX1812-0WN60-0AC0 / 9239 9916 176 SIEMENS 3W... ID.:... OK! Caution! Dangerous high voltage! Dangerous storage spring! De-energize the equipment and secure against re-activation before maintenance. The equipment may only be installed and assembled by qualified personnel! n-observance can result in death, severe personal injury or substantial property damage. All rights reserved. Siemens AG 1998

Contents Topic Page I Master data 3 View and schematic diagram of the operator s console 4 II Tensioning the storage spring 5 III Circuit-breaker ready to close 6 IV Closing the circuit-breaker 7 V Opening the circuit-breaker With the opening solenoid 8 With the electrical release 9 3WN6 electronic overcurrent release Version C/G 10 Version E/F 11 3WN6 - start-up - communication Circuit-breaker 12 Interface 14 Signals 16 Contacts 17 Page 2 of 18

I Master data Date: Contact (Sales) Name: Department: Tel.: Fax: Circuit-breaker data Circuit-breaker ID no.: Delivery notice no.: MRPD: Equipment used for: Type of load: Closing conditions: Location: Customer Name: Address: Tel.: Fax: tes (fault symptoms/cause/action): Page 3 of 18

Fig. 1: Front view and schematic diagram of the operator s console CB position indicator (i) Reset button (after a,n,z,g,n tripping) "Mechanical ON" pushbutton "Mechanical OFF" pushbutton Electronic overcurrent release Spring tension indicator (ii) Ready-to-close indicator (iii) "Electrical ON" pushbutton Lever for manually tensioning storage spring Insertion interlock for crank hole Indicator for circuit-breaker position in guide frame Possible status indications on the operator s console: (i) Circuit-breaker position indicator (ii) Circuit-breaker open Circuit-breaker closed Spring tension indicator I Storage spring released Storage spring tensioned (iii) Ready-to-close indicator OK CB ready to close CB not ready to close (from 03.97) OK CB not ready to close (prior to 03.97) Page 4 of 18

Please confirm the circuit-breaker functions as far as possible on the next few pages (Sections II to IV). You can find the instructions for the circuit-breaker at the following Internet address: http://www.asi.siemens.de/asi/frameset/e_f_kios.html. Tick the boxes after you have checked the functions: II Tensioning the storage spring Manually Tension With motor Spring tensioned? Spring tensioned? Cont. with III "CB ready to close?" All further action by a Siemens specialist Page 5 of 18

III Circuit-breaker ready to close Circuit-breaker ready to close? Close Storage spring released Reset after a/ z/ n tripping Continue with IV Press reset Insertion interlock OK? Undervoltage release installed? Permanent interlocking electromagnet installed? Voltage present at release? All further action by a Siemens specialist Page 6 of 18

IV Closing the circuit-breaker 1 OK Closes Mechanical ON Does not close All further action by a Siemens specialist 2 OK Closes Electrical ON Does not close Voltage present at closing solenoid? Ready-to-close CB (S7) set in closing circuit? Terminals X200.13/ X200.14 All further action by a Siemens specialist Page 7 of 18

V Opening the circuit-breaker 1 With the opening solenoied: Voltage release F1 Permanent interlocking electromagnet Undervoltage release Undelayed F3 Delayed F3 C Please check the following: Auxiliary power supply? All further action by a Siemens specialist Page 8 of 18

2 With the electronic release (see Fig.2 and Fig.3 on pages 8/9) : Y N = = a z n g Inverse-time delayed Short-time delayed Undelayed Earth-fault release Settings: Settings: Settings: Settings: I R A I d A I i A I g A s ms ms T C t d t g Y Y Y Signal? N Signal? N Signal? N Signal? Y N Additional information: Deviation from settings (see above)?... Type of load?... Spurious tripping under load?... Location / type of line voltage (harmonics)?... Other details:...... Check the tripping functions: With the tester (available as an accessory under MRPD: 3WX36 47-5JA00) "a" tripping OK? Y N "n" tripping OK? Y N All further action by a Siemens specialist Page 9 of 18

Fig 2: Electronic overcurrent release (3WN6 Version C/G shown here as an example) Overload release settings 1 Operational current I r 2 Time lag class T C Short-circuit release settings 3 Operating current I d of short-time delayed short-circuit release 4 Delay time t d or inertia t d of short-time delayed short-circuit release 5 Operating current I i of undelayed short-circuit release Earth-fault release settings 6 Operating current I g ΣI : Vector sum of phase currents and N-conductor current (if N-conductor current transformer installed) I g : Direct measurement with current transformer at transformer neutral point 7 Delay time t g or selection of I 2 * t g tripping Settings on operator s panel 8 All settings made with 4 cursor keys plus Enter key, menu guidance on LC display (9) Indications 9 LC display, 2-line 10 "Tripped" LEDs for overload for N-conductor overload for short-time delayed short-circuit release for undelayed short-circuit release for earth fault for freely selectable indications 11 Alarm indicator µp for microprocessor fault ϑ for overtemperature for phase unbalance 12 Release "active" indicator (blinks when release ready) Fig. 2/12 Overcurrent release, Version C/G "aznng" Test functions 13 Test button for functional test 14 Query button for displaying reason for release 15 Clear button for "tripped" indicator 16 Test connector, plug connections for tester and (Versions D, E/F, H, J/K, N and P only) hand-held terminal 18 N-conductor protection with switch for 50 % I rated/100 % I rated 17 Short-time grading control, reversible 19 Earth-fault release "g" Alarm: Earth fault only indicated by LED Trip: Earth fault indicated by LED and circuit-breaker tripped Page 10 of 18

Fig 3: Electronic overcurrent release (3WN6 Version E/F shown here as an example) Overload release settings 1 Operational current I r 2 Time lag class T C Short-circuit release settings 3 Operating current I d of short-time delayed short-circuit release 4 Delay time t d or inertia t d of short-time delayed short-circuit release 5 Operating current I i of undelayed short-circuit release Earth-fault release settings 6 Operating current I g ΣI : Vector sum of phase currents and N-conductor current (if N-conductor current transformer installed) I g : Direct measurement with current transformer at transformer neutral point 7 Delay time t g or selection of I 2 * t g tripping Settings on operator s panel 8 All settings made with 4 cursor keys plus Enter key, menu guidance on LC display (9) Indications 9 LC display, 2-line 10 "Tripped" LEDs for overload for N-conductor overload for short-time delayed short-circuit release for undelayed short-circuit release for earth fault for freely selectable indications 11 Alarm indicator µp for microprocessor fault ϑ for overtemperature for phase unbalance 12 Release "active" indicator (blinks when release ready) Overcurrent release, Version E/F "aznng" Test functions 13 Test button for functional test 14 Query button for displaying reason for release 15 Clear button for "tripped" indicator 16 Test connector, plug connections for tester and (Versions D, E/F, H, J/K, N and P only) hand-held terminal 18 N-conductor protection with switch for 50 % I rated/100 % I rated 17 Short-time grading control, reversible 19 Earth-fault release "g" Alarm: Earth fault only indicated by LED Trip: Earth fault indicated by LED and circuit-breaker tripped Page 11 of 18

3WN6 - start-up - communication 1 Circuit-breaker System de-energized? De-energize system 24 V DC auxiliary voltage "OFF"? Switch off auxiliary voltage Withdrawable circuitbreaker Circuit-breaker version Fixed-mounted circuit breaker Set circuit-breaker to disconnected position Switch "ON" 24 V DC auxiliary voltage "Device" LED at interface lights up Measure auxiliary voltage at circuit-breaker X400.3 24 V DC X400.1 frame Measure: X400.1 } X400.2 Voltage peaks about 5 V DC line (communication level) Red Interface connection defective, replace! Green OK 24 V DC auxiliary voltage not present or polarity reversed Measure supply voltage at connector according to inscription 2 If all correct, but LED still does not light up: replace interface connection! Page 12 of 18

Fig 4 3RK1 interface connection Device LED Interface Receptacle for PROFIBUS Receptacle for circuit-breaker 2 Circuit-breaker switched via bus or communication function < Version 4 Jumper inserted between X400.3 and X400.6? Jumper inserted between X400.4 and X300.14? Jumper terminals Withdrawable circuit-breaker Circuit-breaker version Fixed-mounted circuitbreaker Set circuit-breaker to test position 3 Page 13 of 18

3 Interface connection 3RK1 interface older than Version 1.6? "Interface" LED at interface connection lit "Interface" LED at interface connection lit Green - Circuit-breaker communicating with bus - "Active" LED on electrical release blinking All correct, cont. with 4 Green Orange Communication with circuit-breaker interrupted t lit "Active" LED on elect. release blinking Communication function defective Replace release, repeat "Interface" part Continued overleaf Continued overleaf Page 14 of 18

Continued from previous page Continued from previous page t lit PROFIBUS not active or wiring fault Orange Orange / blinking t lit / blinking DP address incorrect (rotary coding switch on front panel) DP not active DP connector not inserted Analysis: DP error HOTLINE :++49 (0) 9131-7-43833 Red Communication with circuit-breaker interrupted, PROFIBUS fault Red Replace release, repeat "Interface" part Page 15 of 18

4 Signals Information received in input area of PLC: All further action by a Siemens specialist or other qualified person Connect diagnostic module according to instructions Start "Diagnose.EXE" routine Does information on monitor correspond to real situation? The following data is displayed: Rated circuit-breaker current, operating current Circuit-breaker status (open, closed, position, etc.) te: Fixed-mounted circuit-breakers do not have test or operating positions, i.e. the LEDs are lit continuously. Alter the circuit-breaker status (e.g. readiness to close). Do the circuit-breaker signals react to this change? Repeat Part 3 If unsuccessful PLC program error Call PLC programming hotline END Page 16 of 18

Contacts: Low-voltage controlgear, switchgear and systems -Technical Support (hotline) Tel. ++49/ (0) 9131-7-43833 -Emergency delivery service (outside normal office hours, Tel. ++49/ (0) 9621-80-2210 extra charge) -Field service for circuit-breakers Tel. ++49/ (0) 9131-7-43333 SINUMERIK -Technical Support Tel. ++49/ (0) 180-5258000 Automation -SIMATIC Basic Hotline Tel. ++49/ (0) 911-895-7000 Variable-speed drives -Product Support Tel. ++49/ (0) 9131-7-46492 Action to be taken by Siemens specialist Page 17 of 18

Herausgegeben von Bereich Automatisierungs- und Antriebstechnik Gebiet Niederspannungs-Schalttechnik Schaltwerk Berlin D - 13623 Berlin Änderungen vorbehalten Siemens Aktiengesellschaft Issued by Automation & Drives Group Low Voltage Controls & Distribution Berlin Schaltwerk switchgear factory D - 13623 Berlin Federal Republic of Germany Subject to change without prior notice Order.: 3ZX1812-0WN60-0AC0 / 9239 9916 176 Orders to: A&D CD SE LK2 Berlin