Panasonic FP Serial Driver for JMobile

Similar documents
ABB Modbus RTU Driver for JMobile

ROC Plus Communication Driver for JMobile

Omron FINS Ethernet Driver for JMobile

Profibus DP Driver for JMobile

Mitsubishi FX Driver for JMobile

CANopen HMI Communication Driver for JMobile

Mitsubishi FX Ethernet Driver for JMobile

Control Techniques Unidrive - Modbus CMP Ethernet Driver for JMobile

Modbus TCP Server Driver for JMobile

CODESYS V3 Ethernet Driver for JMobile

Modbus TCP Driver for JMobile

CODESYS V2.3 Ethernet Driver for JMobile

Simatic S7 Ethernet driver for JMobile

Connecting UniOP to Moeller Easy800

Connecting UniOP to Fatek Controllers with Facon Protocol

NMEA 0183 driver for JMobile

Connecting UniOP as a Modbus Slave

Connecting UniOP to Beckhoff ADS Ethernet

KNX TP/IP Communication Driver for JMobile

Connecting UniOP to Unidrive SP with Modbus CMP Protocol

Connecting UniOP to CoDeSys Controllers via Ethernet

JMobile V2.0 HF1 Release Notes

Connecting UniOP Using Generic Modbus RTU

Internal PLC (CODESYS) User Manual

Allen-Bradley Micro800 Series

Connecting UniOP to Galil/Yaskawa controllers

Getting started with UniOP and CoDeSys integrated controller

JMobile V2.6 SP1 Release Notes

Connecting UniOP to Omron PLCs with the FINS Protocol

Updating Systems Components in UniOP Series 400 Products

Getting started with JMobile Suite

FP7 Connection Manual

UniOP Command Summary

17 Configuring a BM85 In this chapter

Mitsubishi FX3 Driver Configuration Manual

D0 DCM Module Setup Direct

ALLEN-BRADLEY MICROLOGIX / SLC500 & EASON 2000 FAMILY

JMobile V2.0 SP1 Release Notes

Bristol Babcock BSAP Serial & UDP Communications Drivers

Please refer to application note AN00129 for further details on HCP2 configuration in ABB motion control products.

Control with UniOP. Tech-note PN# tn137-2.doc - 29/07/ Ver Contents

Pass-Through Function

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

DomiOP ebis504. Tech-note. Highlights

OPERATOR INTERFACE PRODUCTS APPLICATION NOTE

C O N T R O L L E R I N F O R M A T I O N S H E E T. Allen-Bradley SLC500 & MicroLogix Series (DF1 BCC Checksum)

Mondo TC. Quick Reference & Setup Guide

Connecting UniOP to Datalogic Barcode Readers

CREATING PANEL APPLICATIONS

Connecting UniOP to Simatic S7 Profibus

Connecting UniOP as Modbus/TCP Server

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

BACnet/MSTP. HMI Setting: How to Import Tags: Supported series: BACnet/MSTP protocol devices

Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies

Yaskawa Electric MP900 Series Driver

IAI Corporation 1998, 1999, For Reference Only.

TxA SoftControl - FnIO-S NA-9173 / NA-9473 Modbus RTU KI

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

Wonderware Operations Integration Supervisory AutomationDirect ADPRO Server (G-1.2 Series)

MDC 700 Series User Manual

INTRODUCTION... 2 GENERAL INFORMATION... 3 DEVICE CHARACTERISTICS... 3 LINK CHARACTERISTICS... 3 DRIVER CHARACTERISTICS... 4 CONFORMANCE TESTING...

CONTROLLER INFORMATION SHEET

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

SIEMENS S7-200 PPI Direct

Communication Setting Sample

VISTA - CTI Multi-port Serial Adapter. Install Guide

Communication Allen Bradley SLC / MicroLogix

KTA-250 Anemometer Alarm Card

BQ351 MODBUS IO DEVICE USER MANUAL

Polling Data Registers from Siemens PLC Series S7-300, S7-400 & S7-1200

Overall Description. Generated by D.J.Withenshaw Date 05/09/2007 Revision A. (Name) only. Page 1 of 7

JMobile Suite User Manual

D8000 SERIES QUICK START GUIDE

Bristol Babcock BSAP Extended Serial Slave

Things to Try If You Have Problems

Contrex M-Series Driver Help Kepware Technologies

This is the procedure to use the Clone module as a serial converter: To enable communication you must set the following parameters in the drive.

FIOD 0808 Manual. The FIOD series products add digital capability to your PLC / SCADA.

The UniDataExchanger is a tool that allows an easier handling of the file transfer to and from UniOP operator panels. Contents

Example 1: Read N7:1, N7:2, N7:3 into IntegersRead[] table, offset for starting index is 2. Fig.1 Source data, MicroLogix 1500.

JMobile Suite. User Manual 2.00

Motion Control Products Application note Connecting CP600 to motion products via Modbus RTU

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR iocontrol USER S GUIDE

B-1122(7) Tutorial Guide

Changing unique password of root user for idrac9 by using Dell EMC License Manager

JMobile V2.0 Exor_template_v1.01

Getting Started with UniOP B Series Panels

Schneider Electric TSX07/37/57 Series Unitelway Driver

Module with RS485 communication option for

Connecting UniOP to Profibus DP TI

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Application Note CTAN #165

EasyBuilder Pro V screen and editing the project with the Work Space window open.

Pro-face Memory Link(SIO) Driver

Vantage DDS. Download Data Software. IOM Manual

MVI46-MCM SLC Platform Modbus Interface Module USER MANUAL. February 5, 2004

CONTROLLER INFORMATION SHEET

Allen-Bradley ONTROLLER NFORMATION HEET. MicroLogix 1000, 1100, 1200, Overview. Communications Cable. PLC Settings

SM210 RS485 - JBUS/MODBUS for SM102E. User instructions

TS8000. Profibus DP Slave Configuration Application Note TS8922U001

Transcription:

Panasonic FP Serial Driver for JMobile This document contains the information needed to connect the panel to control devices using the Panasonic FP standard protocol over a serial communication link. Exor International S.p.A. Ptn0407 Ver. 1.02

Copyright 2011-2015 Exor International S.p.A. Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided as is without warranty of any kind. Third-party brands and names are the property of their respective owners. www.exorint.net Panasonic FP Serial Driver for JMobile 2

Contents Panasonic FP Driver... 4 Protocol Editor Settings... 5 Tag Import... 7 Communication Status... 10 Panasonic FP Serial Driver for JMobile 3

Panasonic FP Driver The operator panels can be connected to a Panasonic FP PLC as the network master using this communication driver. This driver has been designed for connection to the programming port of the PLC. Please note that changes in the communication protocol specifications or PLC hardware may have occurred since this documentation was created. Some changes may eventually affect the functionality of this communication driver. Always test and verify the functionality of your application. To fully support changes in PLC hardware and communication protocols, communication drivers are continuously updated. Always ensure that the latest version of communication driver is used in your application. Document code ptn0407 Version 1.02 Panasonic FP Serial Driver for JMobile 4

Protocol Editor Settings Tech-note Add (+) a driver in the Protocol editor and select the protocol called Panasonic FP from the list of available protocols. The driver configuration dialog is shown in the following figure. Node ID PLC Models Comm Figure 1 Node number of the slave device The list allows selecting the PLC model you are going to connect to. The selection will influence the data range offset per each data type according to the specific PLC memory resources. Recalls the serial port configuration parameters as shown in the figure below. Port Figure 2 Serial port selection. COM1 is the PLC port. COM2 is PC/Printer port on panels with two serial ports or refers to the optional Plug-In module plugged on Slot 1 (or 2) for panels with one serial port on-board. COM3 refers to the optional Plug-In module plugged on Slot 3 (or 4) for panels with one serial port on-board. Panasonic FP Serial Driver for JMobile 5

Baud rate Parity Data bits Stop bits Mode PLC Network Communication parameters for serial communication Serial port mode. Available options: RS-232, RS-485 (2 wires) RS-422 (4 wires) The protocol supports connection to multiple controllers. To enable this, check the "PLC Network" check box and provide the configuration per each node. Figure 3 Panasonic FP Serial Driver for JMobile 6

Tag Import The Panasonic FP driver supports the Tag Import facility. The symbol file can be exported by the controller programming software FPWIN. In FPWIN menu, click on Project > Export > Variables as CSV file, then you can choose if you want to export only the Global variables or All project variables. Figure 4 If you choose to export only the Global variables, FPWIN will show the window of the following picture that allow to customize the elements of the exported csv file. Panasonic FP Serial Driver for JMobile 7

Figure 5 Then, in the Export to file window, choose the CSV file (Unicode) format. Figure 6 Panasonic FP Serial Driver for JMobile 8

Select the driver in the Tag Editor and click on the Import tag button to start the importer. Figure 7 Locate the.csv file and confirm. The tags present in the exported document are listed in the tag dictionary from where they can be directly added to the project using the add tags button as shown in the following figure. Figure 8 Note: when importing the array data types, the importer is expanding them creating individual tags per each array element. Panasonic FP Serial Driver for JMobile 9

Communication Status Tech-note The current communication status can be displayed using the dedicated system variables. Please refer to the User Manual for further information about available system variables and their use. The codes supported for this communication driver are: Error NAK Timeout Line Error Invalid response General Error Notes Returned in case the controller replies with a not acknowledge Returned when a request is not replied within the specified timeout period; ensure the controller is connected and properly configured to get network access Returned when an error on the communication parameter setup is detected (parity, baud rate, data bits, stop bits); ensure the communication parameter settings of the controller is compatible with panel communication setup The panel did receive from the controller a response, but its format or its contents is not as expected; ensure the data programmed in the project are consistent with the controller resources Error cannot be identified; should never be reported; contact technical support Panasonic FP Serial Driver for JMobile 10