DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Similar documents
G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Safety Monitoring Relays

Safety Relay Unit (I/O Unit Type)

Tecnología en Electrónica y Control SRL Ficha Técnica

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

Safety Monitoring Relays

Number of input channels

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

masterelectronics.com onlinecomponents.com

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Model Number Structure

SPST-NO SPDT DPST-NO DPDT

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Inductive Proximity Sensor

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations


Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Making Hazardous Operations Safe and Productive

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Temperature Controller E5C4

SYSMAC Remote Transistor Module

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

Classification Enclosure rating Input voltage Type of

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

I/O delay. (0.32 in ±0.06 in)

D2SW-3L1HS D2SW-01L1HS

Solid-state Timer H3YN

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Thread length (overall length) material

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

2. Actuator B: Ball type P: Pin type F: Flat type

must Operate Voltage (V)

Model Number Structure

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

Solid-State Counter/Timer

Miniature Inductive Prox TL-W

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Chemical Resistant Inductive Prox

Inductive Proximity Sensor

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Special-purpose Basic Switch

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

General-Purpose Photoelectric Sensor

Z-15GW2277 Z-15GW2277-B

Plastic Cylindrical Inductive Prox

Pin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Actuator Terminal Model

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Self-Powered Counters H7EC

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Model Number Structure

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Chip Immune Inductive Prox E2EZ

SRT2-ROC08, SRT2-ROC16

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

Special-Purpose Photoelectric Sensors

Solid State Relays with Failure Detection Function

E2Q4 Square Proximity Sensor

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

Transistor I/O Link Modules

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

onlinecomponents.com

Inductive Proximity Sensor

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Cylindrical Proximity Sensor

Ultra Slim Relays 24

Switching Power Supply

Voltage Current Front-mounting bracket

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

PRODUCT SPECIFICATION. PC Board Relays. Series.

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Link Master Adapter. Ordering Information. Connect High-Density I/O PLC Modules to 16-Point B7A Modules

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Top-actuated (B3U-1000 Series)

Model Number Structure

Transcription:

Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering Information Main contacts Auxiliary contact Number of input Reset mode Input type Rated voltage Category Part number DPST-NO None 2 Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 + common G9SB-200-B 2 Manual-reset Inverse (+/-) G9SB-2002-C 1 channel or 2 + common G9SB-200-D 3PST-NO SPST-NC None (direct Auto-reset --- 24 VDC 3 G9SB-3010 breaking) 2 Inverse (+/-) 24 VAC/VDC 4 G9SB-3012-A 1 channel or 2 + common G9SB-301-B 2 Manual-reset Inverse (+/-) G9SB-3012-C 1 channel or 2 + common G9SB-301-D Model Number Legend G9SB- 1 2 3 4 5 1. Contact Configuration (Safety Output) 2: DPST-NO 3: 3PST-NO 2. Contact Configuration (OFF-delay Output) 0: None 3. Contact Configuration (Auxiliary Output) 0: None 1: SPST-NC 4. Input Configuration None: 1-channel or 2-channel input possible 0: None (direct breaking) 2: 2-channel input 5. Miscellaneous A: Auto-reset, inverse (+/-) input B: Auto-reset, + common input C: Manual-reset, inverse (+/-) input D: Manual-reset, + common input 2

Specifications Ratings Power Input Item G9SB-200 - G9SB-3010 G9SB-301 - Power supply voltage 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24VDC 24 VDC: 24 VDC Operating voltage 85% to 110% of rated power supply voltage range Power consumption 1.4 VA/1.4 W max. 1.7 W max. 1.7 VA/1.7 W max. Inputs Item G9SB-200 - G9SB-3010 G9SB-301 - Input current 25 ma max. 60 ma max. (See Note.) 30 ma max. Indicates the current between terminals A1 and A2. Contacts Item G9SB-200 - G9SB-3010 G9SB-301 - Resistive load (cos θ =1) Rated load 250 VAC, 5 A Rated carry current 5 A Characteristics Item G9SB-200 - G9SB-3010 G9SB-301 - Contact resistance (See Note 1.) 100 mω Operating time (See Note 2.) 30 ms max. Response time (See Notes 2 and 3.) 10 ms max. Insulation resistance (See Note 4.) 100 MΩ min. (at 500 VDC) Dielectric strength Between different 2,500 VAC, 50/60 Hz for 1 min outputs Between inputs and outputs Between power inputs and outputs Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Shock resistance Destruction 300 m/s 2 Malfunction 100 m/s 2 Durability Mechanical 5,000,000 operations min. (at approx. 7,200 operations/hr) Electrical 100,000 operations min. (at approx. 1,800 operations/hr) Error rate, p-level (reference value) 5 VDC, 1 ma Ambient operating temperature -25 to 55 C (with no icing or condensation) Ambient operating humidity 35% to 85% RH Terminal tightening torque 0.5 N m Weight Approx. 115 g Approx. 135 g Approx. 120 g Approved standards (pending) EN954-1, EN60204-1, UL508, CSA C22.2 No. 14 EMC (pending) EMI: EN55011 group 1 class A EMS: EN50082-2 1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. 2. The bounce time is not included in the figure for operating time. 3. The response time is the time it takes for the main contact to open after the input is turned OFF. 4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. 3

Operation G9SB-2002-A (24 VAC/VDC) or G9SB-3012-A (24 VAC/VDC) with 2-Channel Limit Switch Input/Auto-reset Timing Chart Limit switches S1 and S2 K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) Feedback loop KM1 and KM2 (NO) circuit Only the G9SB-3012-A model has terminals 33-34 and 41-42. External connections and timing charts for G9SB-200-B/301-B models are the same as those for G9SB-2002-A/3012-A models. G9SB-2002-C (24 VAC/VDC) or G9SB-3012-C (24 VAC/VDC) with 2-Channel Emergency Stop Switch Input/Manual-reset Timing Chart Emergency stop switch S1 Reset switch S2 circuit Feedback loop K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) Output turns ON with the rising edge of reset switch S2, but will not operate if there is a short breakdown in S2. Only the G9SB-3012-C model has terminals 33-34 and 41-42. External connections and timing charts for G9SB-200-D/301-D models are the same as those for G9SB-2002-C/3012-D models. 4

G9SB-200-D (24 VAC/VDC) or G9SB-301-D (24 VAC/VDC) with 2-Channel Safety Area Sensor/Manual-reset Emitter Receiver Timing Chart F3S-A: Incident Interrupted Reset switch S1 K1 and K2 (NC) K1 and K2 (NO) F3S-A KM1 and KM2 (NC) Shield Gray Gray/black Pink Purple Blue Brown Red Red/black Blue Brown Black White Gray/black Shield Gray Feedback loop KM1 and KM2 (NO) Output turns ON with the rising edge of reset switch S1, but will not operate if there is a short breakdown in S1. circuit F3S-A: Safety Area Sensor S1: Reset switch KM1 and KM2: Magnetic Contactor (LC1D) M: 3-phase motor E1 and E2: 24-VDC power supply (S82K) 1. Connect E1 to model other than the F3S-A. 2. Only the G9SB-301-D model has terminals 33-34 and 41-42. G9SB-3010 (24 VDC) with 2-Channel Limit Switch Input/Auto-reset Timing Chart Limit switches S1 and S2 K1 and K2 (NC) K1 and K2 (NO) Feedback loop KM1 and KM2 (NC) KM1 and KM2 (NO) S1: circuit S2 KM1 and KM2: M: 5

Dimensions Unit: mm G9SB-200 - G9SB-3010 Terminal Arrangement G9SB-200 - G9SB-3010 (green) (green) 2x5=10 112 max. 100 max. 18 max. (Average: 17.5) G9SB-301- Terminal Arrangement G9SB-200-3x5=15 112 max. (green) 100 max. 23 max. (Average: 22.5) 6

Installation Internal Connections G9SB-2002-A/C (24 VAC/VDC) G9SB-3012-A/C (24 VAC/VDC) G9SB-200-B/D (24 VAC/VDC) G9SB-301-B/D (24 VAC/VDC) G9SB-3010 (24 VDC) 1. For 1-channel input with G9SB- -B/D models, short terminals T12 and T22. It is not possible to wire G9SB- 2-A/C models for 1-channel input. 2. Only G9SB-301 - models have terminals 33-34 and 41-42. 7

External Connections G9SB-_2-A/C 2 Channel Input (1 +ve and 1 -ve) G9SB-_-B 2 Channel Input (2 +ve) G9SB-_-B/D 1 Channel Input (1 +ve) G9SB-_-B/D 2 Channel Input (2 PNP, Solid State) S1 T11 S1 T11 T12 S2 T12 T21 S1 T12 T21 S1 T11 T22 Circuit T12 T22 T22 T22 *A2 *DC models only Manual Reset* Auto Reset* T31 T31 S3 T32 T32 *Auto and Manual reset is model specific External Device Monitoring *KM1 T32 *KM2 *Add N.C. contacts of external devices in series with T32 8

Precautions Wiring Turn OFF the G9SB before wiring. Do not touch the terminals of the G9SB while the power is turned ON because the terminals are charged and may cause an electric shock. Use the following to wire the G9SB. Stranded wire: 0.2 to 2.5 mm 2 Solid wire: 0.2 to 2.5 mm 2 Tighten each screw to a torque of 0.5 to 0.6 N m, or the G9SB may malfunction or generate heat. External inputs connected to T11 and T12 or T21 and T22 of the G9SB must be no-voltage contact inputs. Applicable Safety Category All G9SB Relays meet the requirements of Safety Category 4 of the EN954-1 standards when they are used as shown in the examples provided by OMRON. Relays may not meet the standards in some operating conditions. The G9SB-3010 can be applied to Safety Category 3 of the EN954-1 using double breaking. The applicable safety category is determined from the whole safety control system. Make sure that the whole safety control system meets EN954-1 requirements. Mounting Multiple Units When mounting multiple Units close to each other, the rated current will be 3 A. Do not apply a current higher than 3 A. Manual/Auto Reset Operation Please note that auto-reset units cannot be used for manual reset operation. For manual reset units NO switches must be used for correct operation. Connecting Inputs If using multiple G9SB models, inputs cannot be made using the same switch. This is also true for other input terminals. T11 T12 T11 T12 G9SB G9SB Earth Short A positive thermistor is built into the G9SB circuits, so you can detect earth short breakdowns and breakdown shorts between channel 1 and channel 2. (Detection of breakdown shorts between channel 1 and channel 2 is supported for G9SB-2002- / 3012- models only.) In order to detect earth short breakdowns, connect the minus side of the power supply to ground. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173 847-843-7900 For US technical support or other inquiries: 800-556-6766 OMRON CANADA, INC. 885 Milner Avenue Toronto, Ontario M1B 5V8 416-286-6465 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca Cat. No. GC SAFETY-2 2/03 Specifications subject to change without notice Printed in USA 9