Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Similar documents
ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

Operating voltage Maximum

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Fan Coil Actuator FCA/S 1.1M Product Manual

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Room Master Basic RM/S 1.1 Product Manual

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Room Master Basic RM/S 1.1 Product Manual

ABB i-bus KNX Room Master Premium RM/S 2.1 Product Manual

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

ABB i-bus KNX Room Master RM/S 3.1 Product Manual

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus. KNX JRA/S Blind/Roller Shutter Actuator with Binary Inputs Product Manual

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX Binary Inputs BE/S Product Manual

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

Product and functional description

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Product and functional description

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

ABB i-bus KNX Blind/Roller Shutter Actuator JRA/S Product Manual

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Micro Contactor MA Series

Product and functional description

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Relay actuators & Status indicating modules

ABB i-bus KNX Blind/Roller Shutter Actuators JRA/S Product Manual

High-performance switching actuators

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Push Button Interface UP 220D31

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Contact protection relay

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

PHOENIX CONTACT Features

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Product and functional description

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Line Coupler, MDRC LK/S 3.1, GH Q R0001

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

RM35TF V AC

Extension module for lighting control

SITOP 3-phase 24 V DC, 20 to 40 A

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

DC561, digital input/output module,

Power supply CP-D 12/2.1 Primary switch mode power supply

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Operating and mounting instructions

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

DC562, digital input/output module,

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

252F 5WG FB_1 DELTA

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

1.5 Solid State Relays

Non-communicating room controllers

Line Coupler, MDRC LK/S 2.1, GH Q R0001

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Three-phase monitoring relay

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

DX561 Digital Input/Output Module

Transcription:

, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails. The assignment of the physical address as well as the parameter settings is carried out with ETS2 from version V1.3a or higher. The device is powered via the ABB i-bus and does not require and additional auxiliary voltage supply. The is operational after connection of the bus voltage. Technical data Supply * The maximum power consumption of the device results from the following specifications: Connections Operating and display elements Bus voltage Current consumption, bus Leakage loss, bus Leakage loss, device KNX bus connection Relay 16 A Relay 6 A Relay 0.5 A KNX Inputs/Outputs Programming button/led Button /LED Button ON/OFF Fan speed button LED fan speed 1 LED fan speed 2 LED fan speed 3 Valve heating button Valve cooling button /LED /LED /LED 21 32 V DC < 12 ma Maximum 250 mw Maximum 2.85 W* 0.25 W 1.0 W 0.6 W 1.0 W Via bus connection terminals Via screw terminals For assignment of the physical address For toggling between manual operation/ operation via ABB i-bus and displays Programmable function For switching through the individual fan speed For display of fan speed 1 For display of fan speed 2 For display of fan speed 3 For control and display For control and display Button switch contact /LED For switching and display Button binary input /LED For switching and display Button binary input /LED For switching and display Enclosure IP 20 to DIN EN 60 52 Safety class II to DIN EN 61 140 Isolation category Overvoltage category III to DIN EN 60 664-1 KNX safety extra low voltage Pollution degree SELV 24 V DC 2 to DIN EN 60 664-1 Page 1 of 6 2CDC 508 06 D0201

, 2CDG 110 084 R0011 Temperature range Operation Transport Storage Storage at temperatures exceeding +45 C reduces the service life!! -5 C +45 C -25 C +70 C -25 C +55 C Ambient conditions Maximum air humidity 3 %, no condensation allowed Design Modular installation device (MDRC) Dimensions Mounting width in space units Mounting depth Modular installation device, ProM 0 x 72 x 64.5 mm (H x W x D) 4 modules at 18 mm 64.5 mm Installation On 35 mm mounting rail to DIN EN 60 715 Mounting position As required Weight 0.1 kg Housing/colour Plastic housing, grey Approvals KNX to EN 50 00-1, -2 Certification CE mark In accordance with the EMC guideline and low voltage guideline Electronic outputs Rated values 4, non-isolated, short-circuit proofed U n rated voltage I n rated current (per output pair) Continuous current Inrush current 24 230 V AC (50/60 Hz) 0.5 A 0.5 A resistive load at T u up to 20 C 0.3 A resistive load at T u up to 60 C Maximum 1.6 A, 10 s at T u up to 60 C T u = ambient temperature Binary inputs Rated values U n scanning voltage I n scanning current Scanning current I n at switch on Permissible cable length 2 32 V, pulsed 0.1 ma Maximum 355 ma 100 m one-way, at cross-section 1.5 mm² Page 2 of 6 2CDC 508 06 D0201

, 2CDG 110 084 R0011 Fan rated current 6 A Nominal values U n rated voltage I n rated current (per output) 3 contacts 250/440 V AC (50/60 Hz) 6 A Switching currents AC3* operation (cos ϕ = 0.45) DIN EN 60 47-4-1 AC1* operation (cos ϕ = 0.8) DIN EN 60 47-4-1 Fluorescent lighting load to DIN EN 60 66-1 Minimum switching performance DC current switching capacity (ohmic load) 6 A/230 V 6 A/230 V 6 A/250 V (35 μf) 2) 20 ma/5 V 10 ma/12 V 7 ma/24 V 6 A/24 V= Service life Mechanical endurance Electronical endurance to DIN IEC 60 47-4-1 AC1* (240 V/cos ϕ = 0,8) AC3* (240 V/cos ϕ = 0,45) AC5a* (240 V/cos ϕ = 0,45) > 10 7 > 10 5 > 1.5 x 10 4 > 1.5 x 10 4 Switching times 1) Maximun relay position change per output and minute if all relays are switched simultaneously. The position changes should be distributed equally within the minute. Maximum relay position change per output and minute if only one relay is switched. 60 240 1) The specifications apply only after the bus voltage has been applied to the device for at least 10 seconds. Typical delay of the relay is approx. 20 ms. 2) The maximum inrush-current peak may not be exceeded. *What do the terms AC1, AC3 and AC5a mean? In Intelligent Installation Systems different switching capacity and performance specifications which are dependent on the special application have become established in industrial and residential systems. These performance specifications are rooted in the respective national and international standards. The tests are defined so that typical applications, e.g. motor loads (industrial) or fluorescent lamps (residential) are simulated. The specifications AC1 and AC3 are switching performance specifications which have become established in the industrial field. Typical application: AC1 Non-inductive or slightly inductive loads, resistive furnaces (relates to switching of ohmic/resistive loads) AC3 Squirrel-cage motors: Stating, switching off motors during running (relates to (inductive) motor load) AC5a Switching of electric discharge lamps These switching performances are defined in the standard DIN EN 6047-4-1 Contactors and motor-starters Electromechanical contactors and motor-starters. The standard describes starter and/or contactors which previously preferably used in industrial applications. Page 3 of 6 2CDC 508 06 D0201

, 2CDG 110 084 R0011 Rated current output 16 A Nominal values U n rated voltage I n rated current Switching currents AC3* operation (cos ϕ = 0.45) DIN EN 60 47-4-1 AC1* operation (cos ϕ = 0.8) DIN EN 60 47-4-1 Fluorescent lighting load AX to DIN EN 60 66-1 Minimum switching performance Service life Switching times 1) DC current switching capacity (resistive load) 16 A/24 V= Mechanical endurance Electronical endurance to DIN IEC 60 47-4-1 AC1* (240 V/cos ϕ = 0.8) Maximun relay position change per output and minute if all relays are switched simultaneously. The position changes should be distributed equally within the minute. Maximum relay position change per output 1 250/440 V AC (50/60 Hz) 16 A 8 A/230 V 16 A/230 V 16 A/250 V (70 μf) 2) 100 ma/12 V 100 ma/24 V > 3 x 10 6 and minute if only one relay is switched. > 10 5 60 1) The specifications apply only after the bus voltage has been applied to the device for at least 10 seconds. Typical delay of the relay is approx. 20 ms. 2) The maximum inrush-current peak may not be exceeded. 120 *What do the terms AC1, AC3 and AC5a mean? In Intelligent Installation Systems different switching capacity and performance specifications which are dependent on the special application have become established in industrial and residential systems. These performance specifications are rooted in the respective national and international standards. The tests are defined so that typical applications, e.g. motor loads (industrial) or fluorescent lamps (residential) are simulated. The specifications AC1 and AC3 are switching performance specifications which have become established in the industrial field. Typical application: AC1 Non-inductive or slightly inductive loads, resistive furnaces (relates to switching of ohmic/resistive loads) AC3 Squirrel-cage motors: Stating, switching off motors during running (relates to (inductive) motor load) AC5a Switching of electric discharge lamps These switching performances are defined in the standard DIN EN 6047-4-1 Contactors and motor-starters Electromechanical contactors and motor-starters. The standard describes starter and/or contactors which previously preferably used in industrial applications. Page 4 of 6 2CDC 508 06 D0201

, 2CDG 110 084 R0011 Lamp load output Lamps Incandescent lamp load 2300 W Fluorescent lamp T5 / T8 Uncorrected Parallel compensated DUO circuit 2300 W 1500 W 1500 W Low-volt halogen lamps Inductive transformer Electronic transformer Halogen lamp 230 V 1200 W 1500 W 2300 W Dulux lamp Uncorrected Parallel compensated 1100 W 1100 W Mercury-vapour lamp Uncorrected Parallel compensated 2000 W 2000 W Switching performance (switching contact) Maximum peak inrush-current I p (150 μs) Maximum peak inrush-current I p (250 μs) Maximum peak inrush-current I p (600 μs) 400 A 320 A 200 A electronic ballast s (T5/T8, single element) 1) 18 W (ABB EVG 1 x 58 CF) 24 W (ABB EVG-T5 1 x 24 CY) 36 W (ABB EVG 1 x 36 CF) 58 W (ABB EVG 1 x 58 CF) 80 W (Helvar EL 1 x 80 SC) 23 23 14 11 10 1) For multiple element lamps or other types the number of electronic ballast s must be determined using the peak inrush current of the electronic ballast s.. Application program Max. number of communication objects Max. number of group addresses Fan Coil-Aktor/1 70 85 85 Max. number of associations Note For a detailed description of the application program see Fan Coil Actuator product manual. It is available free-of-charge at www.abb.de/knx. The programming requires EIB Software Tool ETS2 V1.3a or higher. If ETS3 is used a *.VD3 or higher type file must be imported. The user program can be found in the ETS2 / ETS3 at ABB/Heating, Cooling, Blower/Fan Coil Actuator 1-fold. Page 5 of 6 2CDC 508 06 D0201

, 2CDG 110 084 R0011 Circuit diagrams 2CDC 072 108 F0008 2CDC 072 132 F0008 with electromotor valve drives with electro-thermal valve drives 1 Label carrier 3 Programming LED 5 Button 7 Binary inputs (A, B) LED fan speed 1-3 11 LED switch contact 13 LED ON/OFF 15 Fan 17 Valve cooling 1 Button valve heating 21 Button valve cooling 23 Button binary input A 25 Button binary input B 2 Programming button 4 Bus terminal connection 6 LED 8 Button fan speed 10 Button switch contact 12 Button ON/OFF 14 Output switch contact 16 Valve heating 18 LED valve heating 20 LED valve cooling 22 LED binary input A 24 LED binary input B Dimension drawing 2CDC 072 111 F0008 Page 6 of 6 2CDC 508 06 D0201