NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

Similar documents
TECHNICAL SPECIFICATIONS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System

Dell EMC PowerVault ME4 Series Storage

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

EMC ISILON X-SERIES. Specifications. EMC Isilon X210. EMC Isilon X410 ARCHITECTURE

EMC ISILON X-SERIES. Specifications. EMC Isilon X200. EMC Isilon X400. EMC Isilon X410 ARCHITECTURE

EMC SYMMETRIX VMAX 40K SYSTEM

ISILON X-SERIES. Isilon X210. Isilon X410 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

EMC ISILON S-SERIES. Specifications. EMC Isilon S200. EMC Isilon S210 ARCHITECTURE

VX3000-E Unified Network Storage

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array

Cisco UCS C200 M2 High-Density Rack-Mount Server

Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System

Vault 8000 Series. Product Overview KEY BENEFITS

Genesis HyperMDC 200D

HYBRID STORAGE TM. WITH FASTier ACCELERATION TECHNOLOGY

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

EMC VNXe SERIES UNIFIED STORAGE SYSTEMS

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Datasheet Fujitsu ETERNUS DX60 S2 Disk Storage System

Data Sheet FUJITSU ETERNUS DX60 S3 Disk Storage System

VX1800 Series Unified Network Storage

VNXe1600 BLOCK STORAGE SYSTEM

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

EMC SYMMETRIX VMAX 10K

Data Sheet FUJITSU Storage ETERNUS DX60 S4 Disk Storage System

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Data Sheet Fujitsu ETERNUS DX400 S2 Series Disk Storage Systems

Data Sheet FUJITSU Storage ETERNUS DX60 S3 Disk Storage System

Data Sheet Fujitsu ETERNUS DX80 S2 Disk Storage System

ISILON HD-SERIES. Isilon HD400 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

Datasheet Fujitsu ETERNUS DX8700 S2 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS DX100 S4 Disk System

Data Sheet FUJITSU Storage ETERNUS DX500 S4 Disk System

Data Sheet FUJITSU Storage ETERNUS DX200 S4 Disk System

SUN ZFS STORAGE 7X20 APPLIANCES

Dynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage

Altos T310 F3 Specifications

Acer Hitachi AMS2300 specifications

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Data Sheet FUJITSU Storage ETERNUS DX500 S4 Disk System

EMC VNXe3200 UNIFIED STORAGE SYSTEM

EonStor DS 3000 Series

DELL EMC SC SERIES EXPANSION ENCLOSURES

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

EonStor DS 1000 series Affordable storage with onboard iscsi and FC/SAS enhances performance and scalability

FUJITSU ETERNUS DX8000 SERIES DISK STORAGE SYSTEMS FOR LARGE ENTERPRISES

ORACLE DATABASE APPLIANCE X3 2

Cloud-Oriented Converged Storage

Network Storage Appliance

Cloud-Oriented Converged Storage

Data Sheet FUJITSU Storage ETERNUS DX200 S3 Disk System

THE SUMMARY. CLUSTER SERIES - pg. 3. ULTRA SERIES - pg. 5. EXTREME SERIES - pg. 9

Data Sheet FUJITSU Storage ETERNUS DX8700 S3 Disk System

The Best Choice for SMBs

EMC VNXe3200 UNIFIED STORAGE SYSTEM

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP

DELL STORAGE NX WINDOWS NAS SERIES CONFIGURATION GUIDE

Data Sheet FUJITSU Storage ETERNUS AF650 S2 All-Flash Array

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Datasheet Fujitsu ETERNUS LT20 S2

Dell PowerVault NX Windows NAS Series Configuration Guide

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

NEC Express5800/R120e-1M System Configuration Guide

HIGH-DENSITY HIGH-CAPACITY HIGH-DENSITY HIGH-CAPACITY

DATA PROTECTION IN A ROBO ENVIRONMENT

DELL EMC NX WINDOWS NAS SERIES CONFIGURATION GUIDE

NEC Express5800/R120d-2M Configuration Guide

Data Sheet FUJITSU Storage ETERNUS AF250 S2 All-Flash Array

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

CSU 0111 Compute Sled Unit

Cisco UCS C24 M3 Server

SUN ZFS STORAGE APPLIANCE

OceanStor 5300F&5500F& 5600F&5800F V5 All-Flash Storage Systems

ZD-XL SQL Accelerator 1.6

Network Service Appliances

Modern hyperconverged infrastructure. Karel Rudišar Systems Engineer, Vmware Inc.

Artico NAS Storage Appliance Site Planning Guide

EonStor DS - SAS Series High-Availability Solutions Delivering Excellent Storage Performance

Dell Storage NX Windows NAS Series Configuration Guide

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family

UNITY FAMILY Flexible Deployment Options

Shared Storage Appliance

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

HITACHI VIRTUAL STORAGE PLATFORM G SERIES FAMILY MATRIX

EonStor DS 3000 Series

Transcription:

DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage system is ideal for organizations seeking significantly increased application performance and simplified storage administration. The NST6000 is an enterprise storage unification engine supporting block-level - Fibre Channel, iscsi (SAN) and file-level - NFS, CIFS, SMB FTP (NAS) traffic without sacrificing performance and eliminating the need for separate software stacks and block and file licenses. The NST6000 leverages a storage operating system called NestOS to conveniently manage all protocols, pools, shares and LUNs within a single system. The E-Centre, NST6000's single-pane management interface, provides a single view to manage all SAN and NAS storage. HYBRID The NST6000's operating system, NestOS, combined with the Nexsan FASTier acceleration technology enables organizations to meet the most demanding I/O performance requirements of both SAN and NAS workloads. FASTier technology is smart. It includes fault tolerant DRAM for the highest possible write caching performance and enterpriseclass SSDs to accelerate read I/O, allowing you to independently customize your performance and capacity points. FASTier read/write performance tiers can be customized at a storage pool level, enabling organizations to extend the use of FASTier to many applications in the data center. UNIFIED HYBRID The combination of solid-state technology, Fibre Channel connectivity, and a highly scalable back-end storage infrastructure makes the NST6000 platform ideal for continuous data availability supporting mission-critical IT applications. Figure 1 NST6000 Unified Hybrid Storage System

SYSTEM CAPACITIES Data listed in the table refers to a single 6U system unless indicated otherwise NST6000 System Form Factor NST6000 Controllers NST6000 Vault Protection Modules 6U 2 x 2U = 4U 2 x 1U = 2U NST6000 System CPU Type Cores Xeon 24 Cores 12 per Controller NST6000 System Memory (DRAM) Basic Premium 192 GB 384 GB 96 GB 192 GB per Controller FASTier Fault Tolerant Write Cache Capacity 32 GB 64 GB Mirrored Capacity in System FASTier Read Cache Capacity Standard Maximum 4.4 TB 9.2 TB Maximum FASTier Read Cache Devices Up to 48 Read Cache Devices FASTier Read Cache Types 200,400GB emlc 100,200GB SLC Maximum SSD Drives Number Capacity 48 Drives 19.2 TB RAID Levels RAID 5, RAID 6 DATASHEET 2

CONNECTIVITY Data listed in the table refers to a single 2U NST6000 Controller unless indicated otherwise NST6000 Host Connectivity 1GbE I/O Embedded STANDARD CONFIGURATION 10 GbE I/O PCIe Card STANDARD CONFIGURATION PCIe Slots for Additional Host Connectivity 1GbE PCIe Cards 10GbE PCIe Cards 4 port 1GbE 1 is management. 1 is reserved. (1) dual-port 10GbE 3 dual-port or quad-port 1GbE dual-port 10GbE Figure 2 with Nexsan E-Series SAS Storage Arrays in a 42U rack. 8 Gb/s FC I/O PCIe Cards dual-port or quad-port 8Gb 1GbE I/O Ports 2 to 10 10GbE I/O Ports 2 to 6 8 Gb/s FC I/O Ports 0 to 6 NST6000 SAS Storage Connectivity: Nexsan E-Series Array 6 Gb/s SAS STANDARD CONFIGURATION # of SAS Ports 6 (x 4) mini-sas ports PCIe Card Type (1) dual-port (1) quad-port Nexsan E-Series Storage # of RAID Arrays Expansion Units 6 Gb/s SAS Switch 16 Mini-SAS wide ports 4 SAS lanes per port NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure 6 Gb/s SAS STANDARD CONFIGURATION # of SAS Ports 6 (x4) mini-sas ports PCIe Card Type (1) dual-port (1) quad-port Nexsan NST224X Number of Enclosures 6 Gb/s SAS Switch Up to 9. 24 2.5 HDD each. 16 Mini-SAS wide ports 4 SAS lanes per port Figure 3 with Nexsan NST224X SAS Storage Enclosures in a 42U rack. NST6000 Fibre Channel Storage Connectivity: Nexsan E-Series Array 8 Gb/s FC CONFIGURATION # of FC Ports 6 ports PCIe Card Type (1) dual-port (1) quad-port DATASHEET 3 Nexsan E-Series Storage # of RAID Arrays Expansion Units

SYSTEM STORAGE CAPACITY Data listed in the table refers to a single 6U NST6000 System unless indicated otherwise NST6000 SAS Storage Connectivity: Nexsan E-Series Array Nexsan E-Series RAID Array Number of Head Units STANDARD CONFIG WITH SAS SWITCH 7 E-Series Arrays 14 Expansion Units 21 Total E-Series E-Series Arrays E-Series Expansion Units E18: 18 3.5 drives in 2U E48: 48 3.5 drives in 4U E60: 60 3.5 drives in 4U E18X: 18 3.5 drives in 2U E48X: 48 3.5 drives in 4U E60X: 60 3.5 drives in 4U Max SATA Capacity Number HDD Capacity @ 4TB/HDD STANDARD CONFIG 540 SATA Drives 2,160 TB WITH SAS SWITCH 1260 SATA Drives 5,040 TB Max 15K SAS Capacity Number HDD Capacity @ 600GB/HDD STANDARD CONFIG 540 SAS Drives 324 TB WITH SAS SWITCH 1260 SAS Drives 756 TB NST6000 SAS Storage Connectivity: Nexsan NST224X Enclosure Number of Enclosures Up to 9. 24 2.5 HDD each. NST224X Max 2.5 10K RPM SAS Drives Number HDD Capacity @ 900GB/HDD Max 2.5 15K RPM SAS Drives Number HDD Capacity @ 600GB/HDD @ 9 Enclosures 216 Drives 216 Drives 194.4 TB 216 Drives 129.6 TB NST6000 Fibre Channel Storage Connectivity: Nexsan E-Series Array Nexsan E-Series RAID Array Number of Units E-Series Arrays E-Series Expansion Units E18: 18 3.5 drives in 2U E48: 48 3.5 drives in 4U E60: 60 3.5 drives in 4U E18X: 18 3.5 drives in 2U E48X: 48 3.5 drives in 4U E60X: 60 3.5 drives in 4U 7200 RPM SATA Capacity Number HDD Capacity @ 4TB/HDD 540 SATA Drives 2,160 TB DATASHEET 4 15K RPM SAS Capacity Number HDD Capacity @ 600GB/HDD 540 SAS Drives 324 TB

SYSTEM STORAGE SERVICES Data listed in the table refers to a single 6U NST6000 System unless indicated otherwise Client Support Storage Services Maximum Single File Size Linux, OS X, Unix, Windows ESXi, Hyper-V, XenServer Fibre Channel, iscsi, NFS, CIFS, SMB, FTP 16 TB Max NFS Shares 512 Max CIFS Shares 512 Max Snapshots Per Share 2,048 Maximum LUN Size 16 TB Max LUNs 1,024 Max Snapshots per LUN 2,048 ENVIRONMENTALS. DIMENSIONS. Data listed in the table refers to single 2U NST6000 Controller unless indicated otherwise Operating Temperature 10-35C, 50-95F Operating Humidity U of Rack Space Height Width Depth Weight 20-95% (non-condensing) 2U 3.5in, 8.76cm 17.2in, 43.8cm 27.87in, 70.78cm >40lbs, >18.1Kg # hot swappable power supplies 2 DATASHEET 5 Maximum Power/Controller Node Voltage, Frequency Heat Dissipation < 430 W Voltage (110): 90-132V; Frequency 47-63 Hz Voltage (220): 180-246V; Frequency 47-63 Hz 1467 btu/hr

NST6000 VAULT PROTECTION MODULE SYSTEM STORAGE SERVICES Data listed in the table refers to a single NST6000 Vault Protection Module unless indicated otherwise NST6000 Vault Protection Module DIMENSIONS 120 V 230 V Dimensions (H x W x D, inches) 1.7 (1U) x 17.2 x 21.8 1.7 (1U) x 17.2 x 21.8 Dimensions (H x W x D, mm) 43.2 x 438 x 554 43.2 x 438 x 554 Weight (kg) 20.0 19.36 Weight (lbs) 44.1 42.7 BATTERY Battery Description Battery Management Sealed. Lead-acid. Maintenance free. Battery life management and advanced warning for battery replacement ELECTRICAL 120 V 230 V Input / Output Connections Input: (1) NEMA 5-15P; Output: (5) NEMA 5-15R Input: (1) C14; Output: (6) C13 Input / Output Nominal Voltage 120V (adjustable to 100/120/125 V) 230V (adjustable to 200/208/220/230/240 V) Input / Output Frequency 50 / 60 Hz 50 / 60 Hz On Utility Voltage Regulation 102 132 V 102 132 V On Battery Voltage Regulation - 10% - + 6% of Nominal - 10% - + 6% of Nominal COMMUNICATIONS User Interface LEDs Communication Card Slots LCD Graphical Display Load protected, on battery and fault One Slot OTHER RoHS Compliance Yes Heat Dissipation (BTU) Line: 113, Battery 714 Audible Noise < 45 db at 1 meter Operating Temperature 0-40C, 32-104F Performance Safety EMC Safety Markings EMC Markings UL 1778, UL497A culus, CE IEC 62040-2 C1-C2 / EN 55024 / CISPR22 Class B / FCC part 15 Class B Storage Temperature -15 40C, 5-10F Relative Humidity 0-95% (non-condensing) DATASHEET 6

HIGHLIGHTS Block Fibre Channel, iscsi File NFS, CIFS, SMB and FTP NestOS storage operating system FASTier Acceleration Technology Multi-Core Xeon CPUs Fault-tolerant DRAM Enterprise-class emlc SSD or SLC SSD Scalable up to 48 SSDs or 19.2 TB 10K, 15K 2.5" SAS HDD 15K SAS, 7200 NL-SAS and 7200 SATA HDD Scalable up to 5 PB (using SATA drives) Scalable up to 756 TB (using SAS drives) Compact 2U NST224X SAS enclosures Efficient E-Series arrays and expansion units - SAS or FC E-Centre Management Interface FEATURES AND BENEFITS Complete host connectivity in a single system and software stack: Fibre Channel, iscsi, NFS, CIFS, SMB and FTP. NST6000 provides fully unified storage with no need to administer discrete tasks, code bases and separate licenses. Application-friendly: Flexible read/write I/O acceleration tier, customizable to the needs of the Pools, LUNs or Shares presented to Hosts. NST6000's FASTier acceleration technology increases storage I/O performance, lowers latency and extends the life of SSDs. Smart, practical use of solid-state technology: Fault-tolerant DRAM delivers the highest write caching performance possible and enterprise-class SSDs accelerate read I/O performance. NST6000's hybrid storage solution optimizes the use of solid-state technology for maximum effectiveness. High-performance continuous availability: Powerful active/active controllers linked together via a high-speed backplane provide up to 700,000 IOPs and non-disruptive failover. NST6000's mirrored write cache with cache vaulting ensures the highest levels of performance and availability. Combined with active/active RAID controllers within the underlying E-Series storage, NST6000 provides high availability storage that can scale up to 5 petabytes. Adaptable storage infrastructure: Use SSDs, 15K SAS drives, 7200 NL-SAS drives and 7200 SATA drives to meet varying storage requirements. NST6000 is a unified hybrid storage platform that can be customized and deployed for performance-oriented workloads, capacity-oriented workloads, or deploy both performance and capacity tiers within the same system. With the non-disruptive addition of FASTier or new disk enclosures, performance and capacity can be independently scaled. Intuitive single-pane management: Interface and set-up assistants designed for the IT generalist. For advanced users the management software offers a command line interface for scripting. NST6000's E-Centre GUI provides a single view to manage file and block traffic while leveraging various types of storage media. ABOUT IMATION Imation is a global data storage and information security company. Imation s Nexsan portfolio features solid-state optimized unified hybrid storage systems, secure automated archive solutions and high-density enterprise storage arrays. For more information, visit www.nexsan.com. DATASHEET 7