Operating Manual RISH DPM Hz

Similar documents
Model Number Structure

3. Phase Indications. kwh 1. Introduction. Units of measurement. kwh. Volts Amps Hz Kwatts KVAr KVA. Degree Wh VAh

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Solid-state Timer H3YN

Tempco Instruction Manual

Model Number Structure

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Ultra Slim Relays 24

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Digital Multifunction Meters. Digital Multifunction Meters

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Energy Division

Conductive Level Controller

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

PRODUCT SPECIFICATION. PC Board Relays. Series.

LCI User Manual mantracourt.com

S82S (3/7.5-W Models)

Model Number Structure

Automated Tuner System Power Distribution Hub

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

EngyVolt RV12 and RV15

700 Series 200 Amp Clamp Meters

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Operating instructions. Standstill monitor A / / 2011

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

PRO-1250D CT MID DIN rail three phase four wire energy meter.

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

User's Guide. Model High Precision Quad Output DC Power Supply

PanelView Plus/VersaView CE Terminals and Display Modules

XC4100 INSTALLATION/OWNER'S MANUAL AM/FM/Cassette Receiver

User Manual CV-87K. PS/2 extender over cat.x. rev: Made in Taiwan

TETRIS 2500 High Impedance Active Probe. Instruction Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Introduction. Features. Index

AirPro Surveyor 2 Manual

CV-24D. Stereo to SPDIF Converter with Adjustable Audio Delay. User Manual. Made in Taiwan

QAL50 Series Analog Line Sensor

Broadband Automatic Disconnect Switch. User Manual

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Energy Division. Installation and Operating Instructions. Integra Ci1

PHOENIX CONTACT - 07/2006

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Model Number Structure

ABB Drives. User s Manual I/O Module Adapter AIMA-01

Model NPN output PNP output Standard. configuration

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

User's Guide. Phase Sequence and Motor Rotation Tester Model

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

User's Guide. Extech AM A AC Analog Clamp Meter

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

MPP200 User s Manual

Jewell DPM PGDA/PGDV/PGD3A/PGD3V BEST IN CLASS

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

Operating instructions. Speed monitor D / / 2014

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

7032 Digital-Analog Multimeter

* * Agilent Power Distribution Unit (PDU) Installation Guide

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Operation Manual for VXC4000 VXC4000 V

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ASTAT XB/XBm Remote Operator

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

PS8 - II. Professional Power Sequencer. User s Manual

PSA200 User s Manual

Universal Power Supplies

Three-phase Phase-sequence Phase-loss Relay

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

Voltage Current Front-mounting bracket

Model 720 Electromechanical Hour Meter

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Model Number Structure

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Zonit μats TM Users Guide μats1-lv Version 1.2

Operating Instructions VEGAMET 381

PMDX-170 Slotted Optical Sensor

MT8050iE series. Installation Instruction (1) (2)

Transcription:

Operating Manual RISH DPM 72mm x 144mm 96mm x 96mm 48mm x 96mm 2-60-006-00-00512_Rev. B - 7/2016

DIGITAL MULTIFUNCTION INSTRUMENT Programmable Digital Panel Meter Installation & Operating Instructions Section 1. Contents Introduction 2. Measurement Reading Screens 3. Programming 3.1 Password Protection 3.2 Set Up Screens 3.2.1 Reset 3.2.2 Auto Scrolling 3.2.3 Number of poles 4. Installation 4.1 EMC Installation Requirements 4.2 Case Dimensions and Panel Cut-out 4.3 Wiring 4.4 Auxiliary Supply 4.5 Fusing 4.6 Earth / Ground Connections 5. Connection Diagrams 6. Specification 3

1. INTRODUCTION DPM HZ is a panel mounted 96 x 96mm, 72 x 144mm and 48 x 96mm DIN Quadratic Digital Panel Meter for the measurement of important electrical parameters like Frequency,. The instrument integrates accurate measurement technology with 4 digits Ultra high bright LED display.. DPM can be configured and Programmed On site for number of poles. DOWN The front panel has two push buttons using which the user can scroll through different screens and configure the product. UP 2. MEASUREMENT READING SCREENS In normal operation, the user is presented with one of the measurement reading screens out of several screens. These screens may be scrolled through one at a time in incremental order by pressing the UP key and in decremental order by pressing DOWN key. TABLE 1: Measured Parameters: Sr No. Measured Parameters 1 2 3 4 Frequency Max Frequency Min Frequency Unit 4

3. Programming The following sections comprise step by step procedures for configuring the DPM for individual user requirements. To access the set-up screens press and hold the DOWN and UP keys Simultaneously. This will take the User into the Password Entry screen (Section 3.1). In Setup mode, if none of the key pressed within 1 min, it will returns operation to the measurement mode. 3.1. Password Protection Password protection can be enabled to prevent unauthorized access to set-up screens, by default password protection is not enabled. Password protection is enabled by selecting a four digit number other than 0000,setting a password of 0000 disables the password protection. * Password Entry: Enter Password, prompt for first digit. (* Denotes that decimal point will be flashing). Press the DOWN key to scroll the value of the first digit from 0 through to 9, the value will wrap from 9 round to 0. Press the UP key to advance to next digit. In the special case where the Password is 0000 pressing the UP key when prompted for the first digit will advance to the Password Confirmed screen. 5

Enter Password, first digit entered, prompt for second digit.(* Denotes that decimal point will be flashing). * Press the DOWN key to scroll the value of the second digit from 0 through to 9, the value will wrap from 9 round to 0. Press the UP key to advance to next digit. Enter Password, second digit entered, prompt for third digit.(* Denotes that decimal point will be flashing). * Press the DOWN key to scroll the value of the third digit from 0 through to 9, the value will wrap from 9 round to 0. Press the UP key to advance to password confirmation screen. Enter Password, third digit entered, prompt for Fourth digit.(* Denotes that decimal point will be flashing). * Press the DOWN key to scroll the value of the fourth digit from 0 through to 9, the value will wrap from 9 round to 0. Press the UP key to advance to password confirmation screen. Enter Password, fourth digit entered, Awaiting verification of password. Password confirmed. Pressing DOWN key will advance to the New / change Password entry stage. Pressing the UP key will advance to the setup screen. (See section 3.2). 6

Password Incorrect. The unit has not accepted the Password entered. Pressing the DOWN key will return to the Enter Password stage. Pressing the UP key exits the Password menu and returns operation to the measurement reading mode. New / Change Password Pressing the DOWN key will scroll the value of the first Digit from 0 through to 9, the value will wrap from 9 round to 0. Pressing the UP key to advance the operation to the next digit and sets the first digit. New / Change Password, first digit entered, prompting for second digit. Pressing the DOWN key will scroll the value of second digit from 0 through to 9, the value will wrap from 9 round to 0. Pressing the UP key to advance the operation to the Next digit and sets the second digit. New / Change Password, second digit entered, prompting for third digit. Pressing the DOWN key will scroll the value of the third from 0 through to 9, the value will wrap from 9 round to 0. Pressing the UP key to advance the operation to the Next digit and sets the third digit. 7

New / Change Password, third digit entered, prompting for fourth digit. Pressing the DOWN key will scroll the value of the fourth from 0 through to 9, the value will wrap from 9 round to 0. Pressing the UP key to advance the operation to the New Password Confirmation screen and sets the fourth digit. New / Change Password, fourth digit entered, Awaiting for confirmation. Pressing the UP key to advance the operation to the New Password Confirmation screen and sets the fourth digit. New Password confirmed. Pressing the DOWN key will return to the New/Change Password. Pressing the UP key will advances to the Set up screen. (see section 3.2). 3.2 Set Up Screens 3.2.1. Reset The following screens allow the users to reset the Min and Max. values of Frequency. Pressing the DOWN key will enter the Reset edit menu. Pressing the UP key will Reset None and enter into Auto scrolling / fixed screen selection menu. 8

Edit the Reset of Parameters Pressing DOWN will scroll the parameters in sequence as Follow : 1. All : To reset All parameters, 2. Hi : To reset Max values, 3. Lo : To reset min. Values, 4. None : No to reset any of the Parameters, Select the Correct parameter to Reset and then Press UP key. This will enter to Reset Parameter Confirmation Screen. Confirmation of parameter for RESET Pressing DOWN will enter back to the reset menu and scroll between the above parameters. Pressing UP key will Reset the Selected Parameter. Then it will enter to auto scrolling or fixed screen selection parameter. 3.2.2 Auto scrolling / Fixed Screen selection This menu allow to select scrolling or fixed screen. Pressing UP key enters confirmation of Fixed Screen. Pressing of DOWN key enters to Edit menu. Fixed Screen / Auto Scrolling Edit. Pressing of DOWN key Rolls between Yes and No. Pressing UP key enters Auto scrolling / fixed screen select confirmation. 9

Confirmation of Auto Scrolling / Fixed Screen Pressing DOWN key enter back to edit menu. Pressing UP key confirms the selection and enters Number of poles selection menu. 3.2.3 No. of Poles Selection : This screen enables to set No. of poles on a Generator of which is to be measured and to which the instrument is connected to measure its output parameters. Pressing DOWN key enters into no. of pole edit menu. Pressing UP key will set the displayed number as No. of poles. Then it will come out of set up menu. No. of Poles edit Pressing DOWN key scrolls the number from 02 to 40 in step of 2. After 40 it wraps to the number again 02. Pressing UP key enters into No. of poles Confirmation screen. No. of Poles Confirmation Pressing DOWN key enters back to No. of poles edit menu. Pressing UP key sets the number on screen as number of poles of generator and exit from setup and goes to measurement screen. 10

4. Installation For 96 x 96mm-Mounting of DPM is featured with easy Clip- in mounting. Push the meter in panel slot (size 92 x 92 mm), it will click fit into panel with the four integral retention clips on two sides of meter. Panel Swivel screw Retention clip for easy mounting If required Additional support is provided with swivel screws (optional) as shown in figure. The front of the enclosure conforms to IP50. Additional protection to the panel may be obtained by the use of an optional panel gasket. The terminals at the rear of the product should be protected from liquids For 96 x 96 mm The DPM should be mounted in a reasonably stable ambient temperature and where the operating temperature is within the range -10 C to 55 C. Vibration should be kept to a minimum and the product should not be mounted where it will be subjected to excessive direct sunlight. 93.0mm 8.0mm For 72 x 144mm For 72 x 144mm-Mounting is by four side clamps, slide the side clamps through side slot till side clamp gets firmly locked in a groove and tight screw provided over clamp. Considerations should be given to the space required behind the instrument to allow for bends in the connection cables. As the front enclosure conforms to IP 54 it is protected from water spray from all direction, additional protection to the panel may be obtained by 14.8mm the use of optional gasket. The terminals at the rear of product should be protected from liquids. 11

For 48 x 96mm-Mounting of DPM 48 x 96 is.featured with easy Clip- in mounting. Push the meter in panel slot (size 48.5 x 96 mm), it will click fit into panel with the four integral retention clips on two sides of meter. The front of the enclosure conforms to IP54. Additional protection to the panel may be obtained by the use of an optional panel gasket. The terminals at the rear of the product should be protected from liquids. For 48 x 96 mm The DPM should be mounted in a reasonably stable ambient temperature and where the operating temperature is within the range -10 C to 55 C. Vibration should be kept to a minimum and the product should not be mounted where it will be subjected to excessive direct sunlight. Caution: 1. In the interest of safety and functionality this product must be installed by a qualified engineer, abiding by any local regulations. 2. Voltages dangerous to human life are present at some of the terminal connections of this unit. Ensure that all supplies are de-energised before attempting any connection or disconnection. 3. These products do not have internal fuses therefore external fuses must be used to ensure safety under fault conditions. 12

4.1 EMC Installation Requirements This product has been designed to meet the certification of the EU directives when installed to a good code of practice for EMC in industrial environments. e.g. screened output and low signal input leads or have provision for fitting RF suppression components, such as ferrite absorbers, line filters etc., in the event that RF fields cause problems. Note: It is good practice to install sensitive electronic instruments that are performing critical functions, in EMC enclosures that protect against electrical interference which could cause a disturbance in function. Avoid routing leads alongside cables and products that are, or could be, a source of interference. To protect the product against permanent damage, surge transients must be limited to 2kV pk. It is good EMC practice to suppress differential surges to 2kV at the source. The unit has been designed to automatically recover in the event of a high level of transients.in extreme circumstances it may be necessary to temporarily disconnect the auxiliary supply for a period of greater than 5 seconds to restore correct operation. ESD precautions must be taken at all times when handling this product. 13

4.2 Case Dimensions and Panel Cut Outs 55 mm 92mm+0.8 92mm+0.8 96 mm 96 mm Display Area 4 mm Panel Cutout 42 mm For 96 x 96 mm 93.0mm 72.0 mm 144.0mm 140mm 68mm Display Area 14.8mm 8.0mm Mounting Position Panel Cutout For 72 x 144 mm 96.0mm 48.0mm Display Area Mounting Position For 48 x 96 mm 14 Installation Cutout

4.3 Wiring Input connections are made directly to screw-type terminals with indirect wire pressure. Numbering is clearly marked on the connector. Choice of cable should meet local regulations. Terminal for 2 2 Voltage input will accept upto 4mm (12AWG) solid or 2.5 mm (12AWG) standard cable. Note : It is recommended to use wire with lug for connection with meter. 4.4 Auxiliary Supply DPM should ideally be powered from a dedicated supply, however it may be powered from the signal source, provided the source remains within the limits of the chosen auxiliary voltage range. 4.5 Fusing It is recommended that all voltage lines are fitted with 1 amp HRC fuse. 4.6 Earth/Ground Connections For safety reasons, panels and accessories should be grounded in accordance with local regulations. 5. Connection Diagrams 13 14 1 2 L N AUX SUPPLY L N 15 L O A D

6. Specification : Inputs Nominal Input Voltage 50 VL-N - 500 VL-N Frequency Input range 10-500 Nominal input voltage < 0.2 VA burden Operating Measuring Ranges Voltage 50 VL-N - 500 VL-N Frequency 10-500 Auxiliary External Auxiliary Supply Frequency Range VA Burden Accuracy Frequency 40V to 300V AC/DC (+/- 5%) or 20V to 40V AC / 20V to 60V DC 45 to 65 < 3 VA Display For 96 x 96mm LED Update rate For 72 x 144mm LED Update rate For 48 x 96mm LED 4 digits, Display height : 14mm Approx. 1 seconds 4 digits, Display height : 20mm Approx. 1 seconds Update rate 4 digits, Display height : 14mm Approx. 1 seconds Controls User Interface 2 Keys Applicable Standards: EMC Immunity ± 0.5 ± 1 Digit Safety Reference conditions for Accuracy : Reference temperature 23 C + 2 C Auxiliary supply voltage Nominal Value + 1 % IP for water & dust Auxiliary supply frequency Nominal Value + 1 % Pollution degree: Installation category: 16 IEC 61326 IEC 61000-4-3. 10V/m min Level 3 industrial Low level IEC 61010-1-2010, Permanently connected use IEC 60529 2 III

Environmental Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Enclosure front Enclosure back Enclosure For 96 x 96mm Style Material Terminals Depth Weight For 72 x 144mm Style -10 to +55 C -20 to +65 C 0... 90% non condensing Minimum 3 minute 15g in 3 planes 10... 150... 10, 0.15mm amplitude IP50(For 96x96) IP54(For 72x144, 48x96 ) IP20(For all models) Material Terminals Depth Weight For 48 x 96mm Style 96mm x 96mm DIN Quadratic Polycarbonate Housing Screw-type terminals < 60 mm 300 grams Approx. Material Terminals Depth Weight 72mm x 144mm DIN Quadratic Polycarbonate Housing Screw-type terminals < 80 mm 322 grams Approx. 48mm x 96mm DIN Quadratic Polycarbonate Housing Screw-type terminals < 68 mm 250 grams Approx. The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method of installation for this product. However, Company has no control over the field conditions which influence product installation. It is the user's responsibility to determine the suitability of the installation method in the user's field conditions. Company only obligations are those in Company standard Conditions of Sale for this product and in no case will Company be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products. 17

WARRANTY Dear Customer, You are now the privileged owner of DPM, a product that ranks the first of its kind in the world. Company provides 12 months warranty from the original date of Purchase against defective material and workmanship. In the unlikely event of failure of the instrument / accessories within the warranty period. Company will repair meter / accessories free of charge. Please hand over the meter / accessories to the dealer / stockist from whom you have purchased along with this card and relevant Cash Memo / Invoice. This warranty entitles you to bring the meter / accessories at your cost to the nearest stockist / dealer and collect it after repairs. NO TRANSPORTATION CHARGES WILL BE REIMBURSED. The warranty is not valid in following cases: 1. Warranty card duly signed and stamped and original Cash Memo / Invoice is not sent along with DPM. 2. Complete warranty card is not presented to authorised person at the time of repairs. 3. Meter / accessories is not used as per the instructions in the instruction manual. 4. Defect caused by misuse, negligence, accidents, tampering and Acts of God. 5. Improper repairing by any person not authorised by the company. 6. Any sort of Modification, Alteration of any sort is made in electrical circuitry. 7. Seal provided inside/outside is broken. In case of dispute to the validity of the warranty, the decision of Company service center will be final. If you bought this DPM directly from the company, and if you notice transit damage, then you must obtain the insurance surveyors report and forward it to Company. Thank you. (To be filled by authorized dealer) Model No.: Serial No. : Date of Purchase : Cash Memo / Invoice No. : Dealer s Signature : Dealer s Stamp : 18