CENTIGRID SURFACE MOUNT COMMERCIAL RELAYS DPDT

Similar documents
CENTIGRID SURFACE MOUNT COMMERCIAL RELAYS SENSITIVE DPDT

CENTIGRID SURFACE MOUNT COMMERCIAL RELAYS DPDT

CENTIGRID SURFACE MOUNT COMMERCIAL RELAYS

CENTIGRID SURFACE MOUNT COMMERCIAL RELAYS DPDT RELAY TYPE. DPDT basic relay DPDT relay with internal diode for coil transient suppression DESCRIPTION

CENTIGRID ESTABLISHED RELIABILITY RELAY DPDT SENSITIVE CMOS COMPATIBLE RELAY TYPE

CENTIGRID ESTABLISHED RELIABILITY RELAY DPDT CMOS COMPATIBLE RELAY TYPE

HIGH REPEATABILITY, Signal Integrity: 20Gbps TO-5 RELAYS, DPDT

HIGH REPEATABILITY BROADBAND TO-5 RELAYS DPDT RELAY TYPE PERFORMANCE FEATURES

HIGH REPEATABILITY, NORMALLY OPEN, BYPASS RF RELAYS RELAY TYPE PERFORMANCE FEATURES

BROADBAND HIGH REPEATABILITY TO-5 RELAY SPDT DC 8 GHz

AZ420 MINIATURE GENERAL PURPOSE RELAY

PERFORMANCE SPECIFICATION SHEET

Long seller backed by product variety and high reliability

HIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY

2.6 GHz capable, 10 W carrying power (at 2.6 GHz), 50Ω/75Ω impedance and 1 Form C relays

Long seller backed by product variety and high reliability

PERFORMANCE SPECIFICATION SHEET

HIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

Series CCR-59S/CR-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch


PERFORMANCE SPECIFICATION

PAGE 1/6 ISSUE SERIES Micro-SPDT PART NUMBER R516 X3X 10X R 516 _ 1 0 _

Leading the market, our 5 mm 2-pole surface mount relays comply with JIS C0806

A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. To be discontinued. RoHS compliant

JV SERIES 1 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

2 pole telecom relay, polarized, Through Hole Type (THT) or Surface Mount Technology (SMT), Relay types: non-latching with 1 coil latching wit

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Series SD. Series Switch Type 2 Feature 3 Line Voltage 1 Output Current - Amps. Dual Output to 50A 600 Vac DC Control Solid-State Relay


AUTOMOTIVE MICRO-ISO RELAY FEATURES

V REG.-Nr. 3919, Z E214024

Transistor drive 2c/4c 5A slim power relays

P2 V23079 Relay Sept 06 Rev. D ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay Nov. 07 Rev. E ECOC: JM10

SUBMINIATURE SERIES R 591. SUBMINIATURE SPnT up to 40 GHz. Our Most Important Connection is with You. SMA SMA 2.9 QMA

1 Form A 8A/16A, Small Polarized Power Relays (latching type)

Signal Relays AXICOM. P1 Relay V23026

COIL CHARACTERISTICS (Vdc) SERIES H,HD,HP,HT,HTD,HPT GENERAL CHARACTERISTICS. Date of issue: 06/ Page 2 of 5. B Vdc

SIGNAL RELAY. FTR-C2 Series. 2 POLES - 2A High Isolation Wide Contact Gap FTR-K1 SERIES FEATURES

SILICON DESIGNS, INC Model 1210 ANALOG ACCELEROMETER

POWER RELAY. NY Series. 1 POLE - 5A Slim Type FTR-K1 SERIES FEATURES

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES NOT FOR NEW DESIGN FEATURES

The Best Relaytion. P2 Relay ISO 9001

MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Mode

ULTRA MINIATURE RELAY Flat High Frequency Relay Surface mount, 1 GHz-band, 2 Form C FTR-B3-RF Series

SILICON DESIGNS, INC Model 1210

RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS Compliant FEATURES ORDERING INFORMATION SAFETY STANDARD AND FILE NUMBERS

JV SERIES 1 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant FEATURES ORDERING INFORMATION

Slim Industrial Relay Type RSLM Electromechanical

78 Series Electromechanical Relay Selection Guide

1 POLE 8 A (MEDIUM LOAD CONTROL)

DISCONTINUED (1999) UR1 SERIES MINIATURE RELAY FEATURES ORDERING INFORMATION

SPST-NO SPDT DPST-NO DPDT

Up to 8 GHz small microwave relays

AUTOMOTIVE MICRO-ISO RELAY FEATURES

COMPACT HIGH POWER RELAY

5. Terminal Shape P: PCB Terminals 6. Classification None : Standard ST : Stand-off 0.64 mm 15 : High-sensitivity (150 mw) Low-sensitivity

R Actuator Terminals: 0: Solder pins 5: D-Sub connector

WA OPTICAL SWITCHES (AWAP)

RA4 SERIES. 4 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS Compliant FEATURES ORDERING INFORMATION SAFETY STANDARD AND FILE NUMBERS

Introducing KILOVAC CAP202 Contactors 12 to 900Vdc, 350 amp DC Power

POWER RELAY. FTR-K3L-WG Series. 1 POLE - 25A - Latching relay FTR-K1 SERIES FEATURES

1 POLE - 10A Low Profile Type. (c) Coil type A : Standard type (530mW) D : High sensitive type (400mW - V type only)

2 POLES - 2 A (Slim Profile Signal Relay)

Dura-ConTM Hermetic Connectors

Amphenol. Printed Circuit Board Technology NAFI + UHD CONNECTORS STANDARD. RELIABLE. PROVEN.

Series LS. 30A to 600 Vac SIP Package DC control LS 24 D 16 C. Figure 1 LS relays; dimensions in inches (mm) (See Figure 12 for LS with HS1)

PRODUCT SPECIFICATION

SSR SERIES MODULES AND BACKPLANES

POWER RELAY. FTR-MY Series. 1 POLE - 5A Slim Power Relay FTR-K1 SERIES FEATURES. APPLICATIONS PLC, I/O module inverter control

COMPACT POWER RELAY. FTR-V1 Series. 1 POLE - 210A Battery Latching relay FTR-K1 SERIES FEATURES. Applications PARTNUMBER INFORMATION

New relay, production not started, engineering samples available. 1 POLE - 8A Reflow Solderable Relay

ULTRA MINIATURE RELAY. FTR-B3 Series. 2 POLES - 2 A (Low Profile Signal Relay) FTR-K1 SERIES FEATURES

DISCONTINUED (2009) RA4 SERIES. 4 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant. FEATURES Ultra high sensitivity

SEMS-4069-DPDT-K DATA SHEET

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

SEMS-4066-DPDT-SMA DATA SHEET

2 POLES - 2 A (Low Profile Signal Relay) (b) Terminal type C : Through hole G : Surface mount S : Surface mount, space saving

NOT FOR NEW DESIGNS AS SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY FEATURES ORDERING INFORMATION

Miniature Matrix: MMC Series Controlled with USB or Ethernet

Miniature Matrix: MMA Series Controlled with USB or Ethernet

Miniature Matrix: MMB Series Controlled with USB or Ethernet

PLATINUM SERIES R PART NUMBER SELECTION. High performance SPDT up to 40 GHz. Our Most Important Connection is with You. SMA - SMA 2.

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

UMD 1423 UNITED MICRO DEVICE INC. Pi filter array with ESD protection. PRODUCT DESCRIPTION APPLICATIONS. This device has 20-bumps 4.

SPDT up to 50 GHz Pc Board - SMA - SMA mm - QMA - SMC - SMB - mini SMB - DIN 1.6/5.6 R Actuator Voltage: 2: 12 Vdc 3: 28 Vdc

JV-KS Series. 1 POLE - 10A High Power Relay POWER RELAY FTR-K1 SERIES FEATURES. PARTNUMBER INFORMATION JV - 12 S - K S [Example] (a) (b) (c) (d) (e)

COMPACT POWER RELAY. FTR-P3 Series. 1 POLE - 25A (for automotive applications) FTR-K1 SERIES FEATURES

FTR-K1 SERIES POWER RELAY 1 POLE - 25A

Monolithic Amplifier CMA-252LN+ Ultra Low Noise, High IP to 2.5 GHz. The Big Deal

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

MINI-ISO AUTOMOTIVE RELAY

RAMSES SERIES R 57. SPnT Terminated & non Terminated up to 40 GHz. Our Most Important Connection is with You.

SECTION 1 IMP / UMP R107

Introduction to High Current Card Edge Connectors

COMPACT POWER RELAY (automotive applications) FTR-P3 Series. Preliminary. 1 POLE - 6A (For 24V car battery) FEATURES. Part Numbers

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with type), RTIII K : Plastic sealed type, RTIII

Transcription:

Series S114 DPDT Non-Latching Commercial Electromechanical Relay CENTIGRID SURFACE MOUNT COMMERCIAL RELAYS DPDT SERIES S114 S114D S114DD DESCRIPTION RELAY TYPE DPDT basic relay DPDT relay with internal diode for coil transient suppression DPDT relay with internal diodes for coil transient suppression and polarity reversal protection The S114 feature: The Series S114 Surface Mount Centigrid Relay is an ultraminiature, hermetically sealed, armature relay. The low profile height (.360 ) and lead spacing make it ideal for applications where extreme packaging density and/or close PC board spacing are required. The specially formed leads are pre-tinned to make the relays ideal for most types of surface mount solder reflow processes. The basic design and internal construction are identical to the Series 114 Centigrid relays, and are capable of meeting Teledyne Relays T2R requirements. The following unique construction features and manufacturing techniques provide overall high reliability and excellent resistance to environmental extremes: All welded construction. Unique uni-frame design providing high magnetic efficiency and mechanical rigidity. High force/mass ratios for resistance to shock and vibration. Advanced cleaning techniques provide maximum assurance of internal cleanliness. Precious metal alloy contact material with gold plating assures excellent high current and dry circuit switching capabilities. The Series S114D and S114DD relays have internal discrete silicon diodes for coil suppression and polarity reversal protection Relay Series Part Numbering System S114-26 / R Q = Solder-Coated Leads 1 (Surface Mount Relays are Solder-Coated by default) R = RoHS Compliant Solder 2 ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS Temperature (Operating) Vibration (General Note I) Shock (General Note I) Acceleration Enclosure Weight Reflow Temperature 55 C to +85 C 30 g s to 3000 Hz 50 g s, 6ms half sine 50 g s Hermetically sealed 0.15 oz. (4.3g) max. 260 C max. temp. 1 min. max Nominal Coil Voltage (26 = 26.5 V, See Page 2 for more Voltages) INTERNAL CONSTRUCTION 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com S114 Page 1 S114\082018\Q3

Series S114 DPDT Non-Latching Commercial Electromechanical Relay SERIES S114 GENERAL ELECTRICAL SPECIFICATIONS (-55 C to 85 C unless otherwise noted. See notes 2 & 3.) Contact Arrangement 2 Form C (DPDT) Rated Duty Continuous Contact Resistance 0.10 Ω max. Resistive: 1 A/ 28 Vdc Contact Load Rating (DC) Inductive: 200 ma/ 28 Vdc (320mH) Lamp: 100 ma / 28 Vdc (320mH) Low level: 10 to 50 μa @ 10 to 50 mv Contact Load Rating (AC) Resistive: 250 ma / 115Vac, 60 and 400 Hz (Case not grounded) 100 ma / 115 Vac, 60 and 400 Hz (Case grounded) 10,000,000 cycles (typical) at low level Contact Life Ratings 1,000,000 cycles (typical) at 0.5 A / 28 Vdc resistive 100,000 cycles min. at all other loads specifi ed above Contact Overload Rating 2 A / 28 Vdc Resistive (100 cycles min.) Coil Operating Power 450 mw typical at nominal rated voltage Contact Carry Rating Contact Factory Operate Time 2.0 msec max. at nominal rated coil voltage Release Time S114: 1.5 ms max. S114D, S114DD: 4.0 ms max. Contact Bounce 1.5 msec max. Intercontact Capacitance 0.4 pf typical Insulation Resistance 10,000 MΩ min. between mutually isolated terminals Dielectric Strength 500 Vrms (60 Hz) @ atmospheric pressure Negative Coil Transient (Vdc) 1.0 Vdc Max. Diode P.I.V. (Vdc) 100 Vdc Min. DETAILED ELECTRICAL SPECIFICATIONS (@25 C) BASE PART NUMBERS (S114, S114D, S114DD) Coil Voltage Coil Resistance (Ohms ±10% @25 C) Coil Curent (S114DD) (madc@25 C) Pick-up Voltage (Vdc, Max) Drop-out Voltage (Vdc) S114-5 S114D-5 S114DD-5 S114-6 S114D-6 S114DD-6 S114-9 S114D-9 S114DD-9 S114-12 S114D-12 S114DD-12 S114-18 S114D-18 S114DD-18 S114-26 S114D-26 S114DD-26 Nom. 5.0 6.0 9.0 12.0 18.0 26.5 Max. 5.8 8.0 12.0 16.0 24.0 32.0 S114, S114D 50 98 220 390 880 1560 S114D 39 78 220 390 880 1560 (Note 5) Min. 93.2 57.8 33.0 25.6 17.5 14.8 Max. 128.2 74.8 42.9 32.8 22.1 18.5 S114, S114D 3.5 4.5 6.8 9.0 13.5 18.0 S114DD 4.0 5.0 7.8 10.0 14.5 19.0 S114, S114D S114DD Min. 0.14 0.18 0.35 0.41 0.59 0.89 Max. 2.3 3.2 4.9 6.5 10.0 13.0 Min. 0.6 0.7 0.8 0.9 1.1 1.4 Max. 2.8 3.4 5.6 6.5 10.0 13.0 S114 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE RELAYS S114\082018\Q3

Series S114 DPDT Non-Latching Commercial Electromechanical Relay SERIES S114 OUTLINE DIMENSIONS.335 (8.51).035 REF (.89).031 REF (.79) 4 TYP 4 TYP.045 MIN 8 PL (1.14) 4 PL (2.54).275 (6.99).360 (9.14) TYP (2.54).375 SQ (9.53) (5.08).410 MIN (10.41).378 +.030.020 TYP ( 9.60 +.76.51 ) Ø.017 REF (.43) 2 ±2 TYP (5.08) (Note 6) (5.08) Dimensions are shown in Inches (Millimeters) (Viewed From Terminals) SCHEMATIC DIAGRAMS 6 7 8 1 2 7 8 1 6 2 7 8 1 6 2 5 4 3 5 4 3 5 4 3 S114 S114D S114DD NOTES: 1. RELAY CONTACTS WILL EXHIBIT NO CHATTER IN EXCESS OF 10 MSEC OR TRANSFER IN EXCESS OF 1 MSEC. 2. TYPICAL CHARACTERISTICS ARE BASED ON AVAILABLE DATA AND ARE BEST ESTIMATES. NO ON-GOING VERIFICATION TESTS ARE PERFORMED. 3. UNLESS OTHERWISE SPECIFIED, PARAMETERS ARE INITIAL VALUES. 4. FOR REFERENCE ONLY. COIL RESISTANCE NOT DIRECTLY MEASURABLE AT RELAY TERMINALS DUE TO INTERNAL SERIES DIODE. 5. MEASURED AT NOMINAL VOLTAGE FOR 5 SEC.. 6. POSITION OF LEADS AS THEY EMERGE FROM RELAY BASE. 7. LEADS WILL FIT NOTED PAD LAYOUT WITH NO OVERHANG. 8. LEAD ENDS ARE COPLANAR WITHIN.008 WIDE TOLERANCE ZONE. 9. TERMINALS COATED WITH SN60 OR SN63 SOLDER PER QQ-S-571. KOVAR EXPOSED AT SHEARED END OF LEADS. PERFORMANCE CURVES (Note 2) db 0.1.2.3.4 10 20 30 40 50 60 70 TYPICAL RF PERFORMANCE INSERTION LOSS RETURN LOSS (VSWR) ISOLATION ACROSS CONTACTS ISOLATION ACROSS POLES.01 0.5.1.5 1.0 FREQUENCY (GHz) FIGURE 1 1.92 1.22 1.07 1.02 1.01 1.00 1.00 VSWR LOAD VOLTAGE (VDC) 300 250 200 150 100 50 TYPICAL DC CONTACT RATING (RESISTIVE) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOAD CURRENT (AMPS DC) FIGURE 2 GENERAL NOTES 1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of 1 μsec. 2. Typical characteristics are based on available data and are best estimates. No on-going verification tests are performed. 3. Unless otherwise specified, parameters are initial values. 4. Relays can be supplied with a spacer pad. See appendix. 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com S114 Page 3 S114\082018\Q3

APPENDIX: Spacer Pads Pad designation and bottom view dimensions Height For use with the following: Dim. H Max. ER412, ER412D, ER412DD.295 (7.49) Ø 712, 712D, 712TN, RF300, RF310, RF320 RF700, RF703 (7.62) ER420, ER420D, ER420DD, 421, ER421D, ER421DD, ER422, ER422D, ER422DD, 722, 722D, RF341.305 (7.75) ER431T, ER432T, ER432, ER432D, ER432DD.400 (10.16) 732, 732D, 732TN, RF303, RF313, RF323.410 (10.41) M4 Pad for TO-5 RF312, RF332 SI800, SI803.350 (8.89) ER411, ER411D, ER411DD, ER411T.295 (7.49) ER431, ER431D, ER431DD.400 (10.16) RF311 (7.62) M4 Pad for TO-5 RF331.410 (10.41) 172, 172D.305 (7.75) ER114, ER114D, ER114DD, J114, J114D, J114DD (7.62) ER134, ER134D, ER134DD, J134, J134D, J134DD.400 (10.16) RF100.315 (8.00) M4 Pad for Centigrid.156 [3.96] RF103.420 (10.67) 122C, A152.320 (8.13) ER116C, J116C (7.62).256 [6.5] ER136C, J136C.400 (10.16) RF180.325 (8.25) M9 Pad for Centigrid Notes: 1. Spacer pad material: Polyester fi lm. 2. To specify an M4 or M9 spacer pad, refer to the mounting variants portion of the part numbering example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise specifi ed, tolerance is ±.010 (.25 mm). 5. Add 10 mω to the contact resistance shown in the datasheet. 6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. A150.305 (7.75) Page 4 (800) 284-7007 www.teledynerelays.com +44 (0) 1236 453124 www.teledyne-europe.com 2016 TELEDYNE RELAYS

APPENDIX: Spreader Pads Pad designation and bottom view dimensions Height For use with the following: Dim. H Max..370 [9.4] SQ [5.08] M Pad 5/ 6/.370 [9.4] MIN.014 [0.36] ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD.388 (9.86) ER412T, J412T 712, 712D, 712TN.393 (9.99) ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD.493 (12.52) ER432T, J432T 732, 732D, 732TN.503 (12.78) ER420, J420, ER420D, J420D ER420DD, J420DD, ER421, J421 ER421D, J421D, ER421DD J422D, ER422DD, J422DD, 722.398 (10.11).390 [9.91] SQ ER411T ER412, ER412D, ER412DD J412, J412D, J412DD.441 (11.20) 712, 712D.451 (11.46) ER421, ER421D, ER421DD 722, 732D.451 (11.46) M2 Pad 7/ 8/.370 [9.4] SQ [5.08] M3 Pad 5/ 6/ 9/.130 [3.3].370 [9.4] MIN ER431T ER432, ER432D, ER432DD.546 (13.87) 732, 732D.556 (14.12) ER411, ER411D, ER411DD, ER411TX ER412X, ER412DX, ER412DDX ER412TX.388 (9.86) 712X, 712DX, 712TNX.393 (9.99) ER420X, ER420DX, ER420DDX ER421X, ER421DX, ER421DDX.398 (10.11) ER422X, ER422DX ER422DDX, 722X, 722DDX ER431, ER431D, ER431DD ER431TX ER432X, ER432DX, ER432DDX ER432TX.493 (12.52) 732X, 732DX, 732TNX.503 (12.78) Notes: 1. Spreader pad material: Diallyl Phthalate. 2. To specify an M, M2 or M3 spreader pad, refer to the mounting variants portion of the part number example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise specifi ed, tolerance is ±.010 (0.25 mm). 5/. Add 25 mω to the contact resistance shown in the datasheet. 6/. Add.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. 7/. Add 50 mω to the contact resistance shown in the datasheet. 8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet. 9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.).014 [0.36] 2016 TELEDYNE RELAYS SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 5

APPENDIX: Ground Pin Positions Ø [Ø5.08] "X" POSITION Ø [Ø5.08] 36 ±3 45 ±3 TO-5 Relays: ER411T, ER412, ER412T, ER420, ER421, ER422, ER431T, ER432, ER432T, 712, 712TN, 400H, 400K, 400V, RF300, RF303, RF341, RF312, RF332, RF310, RF313, RF320, RF323, SI800, SI803, RF700, RF703 TO-5 Relays: ER411, ER431, RF311, RF331 "W" POSITION.050 [1.27] "X" POSITION "U" POSITION (ER116C and ER136C only) Centigrid Relays: RF180, ER116C, 122C, ER136C Centigrid Relays: RF100, RF103, ER114, ER134, 172 Z Position Loopback Relays: LB363 Y Position Indicates ground pin position Indicates glass insulated lead position Indicates ground pin or lead position depending on relay type NOTES 1. Terminal views shown 2. Dimensions are in inches (mm) 3. Tolerances: ±.010 (±.25) unless otherwise specifi ed 4. Ground pin positions are within.015 (0.38) dia. of true position 5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref. 6. Lead dia. 0.017 (0.43) nom. Page 6 (800) 284-7007 www.teledynerelays.com +44 (0) 1236 453124 www.teledyne-europe.com 2016 TELEDYNE RELAYS