REGULATED DC POWER SUPPLIES.

Similar documents
200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

REGENERATIVE LOAD ERI SERIES

Series E/PSI U

LAB-DSP HIGH DENSITY DC POWER SOURCE

Keysight U8030 Series Triple-Output DC Power Supplies

Power Supply Selector Guide

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Sorensen XEL & New XEL-P Series

AIM & THURLBY THANDAR INSTRUMENTS

REGENERATIVE LOAD ERI SERIES

RT4F-110V/25A RECTIFIER

Features. Description. Applications

RT4B-110V/12A RECTIFIER

TSX SERIES High power laboratory DC Power Supplies

DPS SERIES DC POWER SUPPLIES

RT4F-48V/50A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

A. Advanced Features. Configurable High Power Solution

SM15K - Interface modules

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

T H U R L B Y T H A N D A R I N S T R U M E N T S

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

LAB-SCUBI SINGLE CHANNEL BIDIRECTIONAL PSU

Programmable Digital Controlled DC Power Supplies

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Programmable DC Power Supplies XLN Series

SM1500-Series SM SM SM SM SM SM 300-5

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

RT12-240V/2.4kW Rectifier Specification

AC-DC Converter REC K10

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

WORLD LEADING PRODUCTS FOR LASER SCIENTISTS AND ENGINEERS

Multi-Range Programmable DC Power Supplies 9115 Series

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

AIM & THURLBY THANDAR INSTRUMENTS

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

EA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W W ELECTRONIC DC LOADS

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

AIM & THURLBY THANDAR INSTRUMENTS

Advanced Test Equipment Rentals ATEC (2832)

EPS Stromversorgung PSE U. Operating Guide. DC High Efficiency Power Supply

RT7-48V/6kW Specification

Manatronics 4kW Electronic Load

MODULAR DC POWER SUPPLY MODEL 62000B SERIES MODEL 62000B SERIES. Modular DC Power Supply. Ethernet. Key Features :

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

T H U R L B Y T H A N D A R I N S T R U M E N T S

Sorensen XT Series W A. 60 Watt Linear Performance DC Power Supply V. Low noise and ripple. Excellent line/load regulation

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Series Watt DC Power Supplies

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

Advanced Test Equipment Rentals ATEC (2832)

Switched Mode Power Supply Operating manual PAP800

BIPOLAR OPERATIONAL POWER SUPPLY

REGULATED DC POWER SUPPLIES

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

capability for accurate voltage and cur- readings of the UUT s input parameters. 8 bit TTLs, DC-ON, fault output signal and

Precision Voltage Measurement. Instruments. Applications. Voltage Inputs. High-Stability, Low Drift Voltage References. Key Design Features

PROGRAMMABLE DC POWER Supply MODEL 62000P SERIES MODEL 62000P SERIES. Programmable DC Power Supply PFC

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

AP SERIES SYSTEMS POWER SUPPLIES. Autoranging power supplies for bench or systems use FEATURES

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

transient waveforms. This capability allows devices to be tested to DC voltage dropouts, simulation, battery automated charging,

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

LAB-HPP COMPACT HIGH POWER DC SOURCES

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

DINALOG A 144 x 36 A1400 Light-Strip Indicator

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

Programmable DC Power Supplies For Laboratory & System Integration

SITOP 3-phase 24 V DC, 20 to 40 A

Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Sorensen XT Series W A. 60 Watt Linear Performance DC Power Supply V

PS U Series W to 3000 W. Programmable DC Power Supplies THE POWER TEST EXPERTS.

2U/5U. AC + DC Power Solutions. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

Sorensen SG Series - Water Cooled kw V A. Programmable Precision High Power DC Power Supply

Load up on the NEW SERIES EL ELECTRONIC LOADS. from Kepco

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV1200A kv kva

ATV1200A kv kva

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

Transcription:

REGULATED DC POWER SUPPLIES. PRODUCT CATALOG 2011

PRODUCT CATALOG 2011 DelTA elektronika Table of contents: SM-series SM6000-Series 2 SM3300-Series 4 SM3000-Series 6 SM1500-Series 8 SM800-Series 10 ES-series ES300-Series 12 ES150-Series 13 EST150-Series 15 Rack units 1200S-Series 16 S280-Series 17 240S-Series 18 SX-Series 19 U-Series 20 1 Interfaces PSC-Series 21 ANALOG-Series 24

SM6000 Series 6000 W DC power supplies AppliCATioNs & options SM6000 Series Designed for long life at full power Excellent dynamic response to load changes and short circuit conditions Low audible noise: fans are temperature controlled Stacking is allowed, space between units is not required High power system configuration from multiple units 19 rack mounting or for laboratory use (feet included) Remote sensing Interlock Typical Applications Solar Inverter testing, PV-simulation Plasma chambers Hybrid car test systems ATE in industrial production lines Available Options Automotive battery simulation Controlled battery (dis)charging Lasers Driving PWM-controlled DC-motors Accurate current sources Aerospace and military equipment Increased High Speed Two-Quadrant Models Voltage range Current range Output Power Programming Output: Power Sink The conservatively A 10 to 20 times higher Two quadrant operation 0,4ms rated unit allows to deliver programming speed maintains the output SM 15-400 0-15 V 0-400 A extra output power with (down to 0.4 ms rise voltage constant regardless the output power is Increased Power Output High Speed Programming Two-Quadrant Output: SM 30-200 0-30 V 0-200 A Master / Slave parallel and series operation with the same reliability. time at full load) and Power Sink 2 At some derating, either the maximum lower output capacitance. positive or negative. Ideal for PWM-speed 3 voltage and current sharing SM 45-140 0-45 V 0-140 A output voltage or the maximum output Excellent for laser applications, test systems controlled DC-motors and ATE systems. SM 60-100 0-60 V 0-100 A or as current source with low parallel current can be increased by about 10%. capacitance as used in plasma chambers. SM 70-90 0-70 V 0-90 A SM 120-50 0-120 V 0-50 A SM 300-20 0-300 V 0-20 A SM 600-10 0-600 V 0-10 A Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. A higher output isolation allows series operation up to 1200 V. High Input Voltage High Input Voltage Higher input voltages possible for operation at line voltages of 440 V AC and 480 V AC (for USA). More information about this: Page 21 Width = 19 Height = 4 U Three phase input Weight = 27 kg : 380 / 400 / 415 V AC, optional 440 / 480V AC V nom. line to line (48-62 Hz) Active Power Factor Correction (PFC) : 0.98 (at 100% load) : up to 90% (at full load) : from 0.8 mv rms / 8 mv pp : from 2.5 mv (0-100% load step) Programming speed : from 3.3 ms (10-90%), optional from 0.4 ms Analog programming accuracy : from 0.2% Output voltage and current stability : 5.10-5 / 10.10-5 and Interfaces Factory installed programming interfaces: & Interfaces Ethernet controller (incl. sequencer) PROFIBUS controller CANBUS controller RS232 controller IEEE488 controller ISO AMP CARD isolated analog Details about interfaces: Page 21-24 Digital Voltage and Reliable, longlife digital encoders can be implemented at the front panel. Digital Encoders Includes total front panel lock (also for CV/CC-knobs) and a coarse or fine pitch adjustment depending on the turning speed. Secured Voltage and For maximum security, the CV / CC settings can be adjusted with a screwdriver Secured Voltage and only and are protected with a plastic cap from accidental adjusting.

13.5 88.1 SM3300 Series 3300 W DC power supplies AppliCATioNs & options SM3300 Series New unit: available 2011, 2 nd quarter Typical Applications Solar Inverter testing, PV-simulation Car test systems ATE in industrial production lines Plasma chambers Automotive battery simulation Controlled battery (dis)charging Lasers Driving PWM-controlled DC-motors Accurate current sources Aerospace and military equipment SM 66 - AR - 110 Autoranging output SM 330 - AR - 22 Autoranging output SM 660 - AR - 11 Autoranging output 0-33 V 0-66 V 0-165 V 0-330 V 0-330 V 0-660 V 0-110 A 0-55 A 0-22 A 0-11 A 0-11 A 0-5.5 A Designed for long life at full power Low audible noise: fans are temperature controlled Operation on single and three phase input voltages Standard Ethernet interface, LXI class C Large user display, menu driven operation Durable digital encoders for voltage and current adjustment Plug and play optional interfaces USB input for exchange of settings and wave forms Standard Digital Voltage and Ethernet Controller A 16 bit Ethernet Arbitrary Waveform Reliable, longlife digital interface for programming generator or stand- encoders are implemented and monitoring. alone automation. at the front panel. Models Voltage range Current range Includes total front panel Network More information about this: 4 lock (also for CV / CC-knobs) and a coarse Page 21 5 SM 18-220 0-18 V 0-220 A or fine pitch adjustment depending on the turning speed. A higher output isolation allows series operation up to 1200 V. USB-Input Front panel USB-input for exchange of settings and waveforms. USB Connector Width = 19 Height = 2 U Single and Three phase input Weight = 15 kg : 180-528 V AC (single or three phase 48-62 Hz) derating at low input voltage Active Power Factor Correction (PFC) : up to 0.99 (at 100 % load) : up to 90% (at full load) : from 1.6mV rms / 8mV pp : from 5 mv (0-100% load step) Programming speed : from 7 ms (10-90%), optional from 0.3 ms Output voltage and current stability : from 4.10-5 / 10.10-5 34 425 33 482.5 mm The specifications are preliminary and subject to changes Available Options and Interfaces Field installable interfaces: PROFIBUS controller CANBUS controller RS232 controller IEEE488 controller Isolated Analog Programming Master / Slave controller High Speed Programming A 10 to 20 times higher 0,4ms programming speed (down to 0.3 ms rise time at full load) and lower output capacitance. Excellent for laser applications, test systems or as current source with low parallel capacitance as used in plasma chambers. Note: standard no analog interface See our website for details about the new interfaces specifically for SM3300 (interfaces in this catalog are not compatible with SM3300). Two-Quadrant Output: Power Sink Two quadrant operation maintains the output voltage constant regardless the output power is positive or negative. Ideal for PWM-speed controlled DC-motors and ATE systems.

SM3000 Series 3000 W DC power supplies AppliCATioNs & options SM3000 Series Designed for long life at full power Low audible noise: fans are temperature controlled Master / Slave parallel and series operation with voltage and current sharing Stacking is allowed, space between units is not required 19 rack mounting or for laboratory use (feet included) High power system configuration from multiple units Remote sensing Typical Applications Solar Inverter testing, PV-simulation Plasma chambers Car test systems ATE in industrial production lines Available Options Automotive battery simulation Controlled battery (dis)charging Lasers Driving PWM-controlled DC-motors Accurate current sources Aerospace and military equipment Increased High Speed Two-Quadrant Output Power Programming Output: Power Sink The conservatively A 10 to 20 times higher Two quadrant operation 0,4ms rated unit allows to deliver programming speed maintains the output Models Voltage range Current range extra output power with (down to 0.33 ms voltage constant regardless the output power is Increased Power Output High Speed Programming Two-Quadrant Output: the same reliability. rise time at full load) Power Sink 6 At some derating, either the maximum and lower output capacitance. positive or negative. Ideal for PWM-speed 7 SM 15-200 D 0-15 V 0-200 A output voltage or the maximum output Excellent for laser applications, test systems controlled DC-motors and ATE systems. SM 30-100 D 0-30 V 0-100 A or as current source with low parallel current can be increased by about 10%. capacitance as used in plasma chambers. SM 45-70 D 0-45 V 0-70 A SM 70-45 D 0-70 V 0-45 A SM 120-25 D 0-120 V 0-25 A SM 300-10 D 0-300 V 0-10 A Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. A higher output isolation allows series operation up to 1000 V. More information about this: Page 21 Width = 19 Height = 3 U Three phase input Programming speed Weight = 15 kg Analog programming accuracy : from 0.2% Output voltage and current stability : 4.10-5 / 10.10-5 : 380 / 400 / 415 V AC, V nom. line to line (48-62 Hz) : up to 90% (at full load) : from 1.6 mv rms / 8 mv pp : from 5 mv (0-100% load step) : 7 ms (10-90%), optional from 0.33 ms and Interfaces Factory installed programming interfaces: & Interfaces Ethernet controller (incl. sequencer) PROFIBUS controller CANBUS controller RS232 controller IEEE488 controller ISO AMP CARD isolated analog Details about interfaces: Page 21-24 Secured Voltage and For maximum security, the CV / CC settings can be adjusted with a screwdriver Secured Voltage and only and are protected with a plastic cap from accidental adjusting.

SM1500 Series 1500 W DC power supplies AppliCATioNs & options SM1500 Series SM 400 - AR - 8 Autoranging output Width = 19 Height = 2 U 0-200 V 0-400 V Weight = 9,9 kg 0-8 A 0-4 A Single phase input : 90-265 V AC (48-62 Hz) Active Power Factor Correction (PFC) : 0.99 (at 100 % load) : up to 91% (at full load) : from 1.8 mv rms / 8 mv pp : from 0.5 mv (0-100% load step) Programming speed : from 3.4 ms (10-90%), optional from 0.2 ms Analog programming accuracy : from 0.2% Output voltage and current stability : 6.10-5 / 9.10-5 Designed for long life at full power Low audible noise: fans are temperature controlled Stacking is allowed, space between units is not required 19 rack mounting or for laboratory use (feet included) High power system configuration from multiple units Remote sensing Interlock Typical Applications Solar Inverter testing, PV-simulation Semiconductor burn-in & processing Car test systems ATE in industrial production lines Available Options Lasers Controlled battery (dis)charging Component device testing Driving PWM-controlled DC-motors Accurate current sources Aerospace and military equipment Models Voltage range Current range Increased High Speed Two-Quadrant SM 15-100 0-15 V 0-100 A Output Power Programming Output: Power Sink The conservatively A 10 to 20 times higher Two quadrant operation 0,4ms 8 SM 35-45 0-35 V 0-45 A rated unit allows to deliver programming speed maintains the output extra output power with (down to 0.2 ms rise voltage constant regardless the output power is SM 52-30 0-52 V 0-30 A Increased Power Output High Speed Programming Two-Quadrant Output: Master / Slave parallel and series operation with voltage and current sharing the same reliability. time at full load) and Power Sink SM 52 - AR - 60 0-26 V 0-60 A At some derating, either the maximum lower output capacitance. positive or negative. Ideal for PWM-speed Autoranging output 0-52 V 0-30 A output voltage or the maximum output Excellent for laser applications, test systems or as current source with low parallel controlled DC-motors and ATE systems. current can be increased by about 10%. SM 70-22 0-70 V 0-22 A capacitance as used in plasma chambers. 9 SM 120-13 0-120 V 0-13 A SM 300-5 0-300 V 0-5 A More information about this: Page 21 Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. and Interfaces Factory installed programming interfaces: & Interfaces Ethernet controller (incl. sequencer) PROFIBUS controller CANBUS controller RS232 controller IEEE488 controller ISO AMP CARD isolated analog Details about interfaces: Page 21-24 A higher output isolation allows series operation up to 1000 V. Digital Voltage and Reliable, longlife digital encoders can be implemented at the front panel. Digital Encoders Includes total front panel lock (also for CV / CC-knobs) and a coarse or fine pitch adjustment depending on the turning speed. Secured Voltage and For maximum security, the CV / CC settings can be adjusted with a screwdriver Secured Voltage and only and are protected with a plastic cap from accidental adjusting.

SM800 Series 800 W DC power supplies AppliCATioNs & options SM800 Series SM 70 - AR - 24 Autoranging output SM 400 - AR - 4 Autoranging output Width = 19 Height = 2 U 0-35 V 0-70 V 0-200 V 0-400 V Weight = 5,4 kg 0-24 A 0-12 A 0-4 A 0-2 A Single phase input : 90-265 V AC (48-62 Hz) Active Power Factor Correction (PFC) : 0.99 (at 100% load) : up to 89% (at full load) : from 2 mv rms / 8 mv pp : from 0.2 mv (0-100% load step) Programming speed : from 4 ms (10-90%), optional from 0.2 ms Analog programming accuracy : from 0.2% Output voltage and current stability : 6.10-5 / 9.10-5 Designed for long life at full power Low audible noise: fans are temperature controlled Stacking is allowed, space between units is not required High power system configuration from multiple units Laboratory use (feet included), 19 rack mounting optional Remote sensing Interlock Typical Applications Accurate current sources Electronic circuit development Component device testing ATE in industrial production lines Available Options Automotive battery simulation Controlled battery (dis)charging Lasers Driving PWM-controlled DC-motors Medical research equipment Aerospace and military equipment Increased High Speed Two-Quadrant Output Power Programming Output: Power Sink The conservatively A 10 to 20 times higher Two quadrant operation 0,4ms 10 rated unit allows to deliver programming speed maintains the output extra output power with (down to 0.2 ms rise voltage constant regardless the output power is Increased Power Output High Speed Programming Two-Quadrant Output: Models Voltage range Current range Master / Slave parallel and series operation with voltage and current sharing the same reliability. time at full load) and Power Sink At some derating, either the maximum lower output capacitance. positive or negative. Ideal for PWM-speed output voltage or the maximum output Excellent for laser applications, test systems or as current source with low parallel controlled DC-motors and ATE systems. SM 7.5-80 0-7.5 V 0-80 A current can be increased by about 10%. 11 SM 18-50 0-18 V 0-50 A capacitance as used in plasma chambers. More information about this: Page 21 Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. and Interfaces Factory installed programming interfaces: & Interfaces Ethernet controller (incl. sequencer) PROFIBUS controller CANBUS controller RS232 controller IEEE488 controller ISO AMP CARD isolated analog Details about interfaces: Page 21-24 A higher output isolation allows series operation up to 1000 V. Digital Voltage and Reliable, longlife digital encoders are implemented at the front panel. Digital Encoders Includes total front panel lock (also for CV / CC-knobs) and a coarse or fine pitch adjustment depending on the turning speed. Secured Voltage and For maximum security, the CV / CC settings can be adjusted with a screwdriver Secured Voltage and only and are protected with a plastic cap from accidental adjusting. Front Connection 19 Rack Mounting Adapter Front Power Output Bind posts at the front panel instead of at the rear panel. 19 Rack Mounting Adapter The 19 mounting adapters makes it possible to position one or two units side by side in a 19 rack.

ES300 Series 300 W DC power supplies ES150 Series 150 W DC power supplies Very low output ripple and spikes High programming speed Designed for long life at full power Very low output ripple and spikes Designed for long life at full power 12 13 Model Voltage range Current range ES 030-10 0-30 V 0-10 A Master / Slave parallel and series operation with voltage and current sharing Voltage and current control with 10 turn potentiometers For laboratory use or optional 19 rack mounting Models Voltage range Current range ES 015-10 0-15 V 0-10 A ES 030-5 0-30 V 0-5 A ES 075-2 0-75 V 0-2 A ES 0300-0.45 0-300 V 0-450 ma Master / Slave parallel and series operation with voltage and current sharing Voltage and current control with 10 turn potentiometers For laboratory use or optional 19 rack mounting Convection cooling Width = half 19 Height = 66 mm, incl. feet Weight = 3,1 kg Width = half 19 Height = 66 mm, incl. feet Weight = 1,7 kg Single phase input : 92-265 V AC (48-62 Hz) Active Power Factor Correction (PFC) : 0.99/0.96 (at 100% load) : up to 86% (at full load) : 5 mv rms / 15 mv pp : 10 mv (0-100% load step) : 50 µs (50-100% load step) Programming speed : 0.8 ms (10-90%) Analog programming accuracy : from 0.2% Output voltage and current stability : 30.10-5 / 10.10-4 Available Options More information about options. Page 14 Single phase input : 90-265 V AC (48-62 Hz) Active Power Factor Correction (PFC) : 0.99/0.83 (at 100% load) : up to 84% (at full load) : from 0.5 mv rms / 8 mv pp : from 5 mv (0-100% load step) Programming speed : from 7 ms (10-90%) Analog programming accuracy : from 0.2% Output voltage and current stability : from 10.10-5 / 10.10-5 Available Options More information about options. Page 14

Applications & Options ES150 / 300 Series EST150 Series 150 W, Triple output DC power supplies Typical Applications Test and Measurement Controlled battery charging Electronic Circuit Development Component device testing ATE in industrial production lines Laboratory analysis Medical research equipment Accurate current sources Available Options (Not for EST150) Model Voltage range Current range EST 150 Output 1 Output 2 Output 3 Width = half 19 Height = 146 mm, incl. feet 0-20 V 0-20 V 0-10 V Weight = 3,5 kg 0-2.5 A 0-2.5 A 0-5 A Single phase input : 90-265 V AC (48-62 Hz) Active Power Factor Correction (PFC) : 0.99/0.83 (at 100% load) : up to 81% (at full load) : from 0.5 mv rms / 8 mv pp : from 5 mv (0-100% load step) : 100 µs (50-100% load step) Tracking accuracy : 0.5% Output voltage and current stability : 10.10-5 / 10.10-5 Very low output ripple and spikes Designed for long life at full power Increased Secured Voltage and Output Power A higher output isolation The conservatively allows series operation For maximum security, the rated unit allows to deliver up to 1000 V. CV / CC settings can be extra output power with adjusted with a screwdriver Increased Power Output the same reliability. Secured Voltage and only and are protected 14 At some derating, either the maximum with a plastic cap from accidental adjusting. 15 output voltage or the maximum output current can be increased by about 10%. More information about this: Page 21 & Interfaces Ethernet controller PROFIBUS controller CANBUS controller RS232 controller Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. and Interfaces Factory installed programming interfaces: External programming interface modules: IEEE488 controller module ISO AMP module Details about interfaces: Page 21-24 Rear Connection Rear Power Output and Remote Sensing Output terminals at the rear panel instead of bind posts at the front panel, includes remote sensing. 19 Rack Mounting Adapter Using the 19 mounting adapters, it is possible to position the ES 19 Rack Mounting Adapter units in a 19 rack. Several configurations possible with multiple ES and / or PSC or ISO AMP modules. Only available for the ES 150 series 3 independent, floating outputs Dual voltage tracking or series tracking mode 3 output On / Off buttons Convection cooling Voltage and current control with 10 turn potentiometers Generic Emission EN 61000-6-3 (EN55022B) Generic Immunity EN 61000-6-2 Safety EN 60950 / EN 61010 / SELV

1200S Series 600 W & 1200 W DC power supplies S280 Series 280 W DC power supplies Models Voltage range Current range 1200 S 24 1200 S 48 12-15 V 24 V 30 V 24-30 V 48 V 60 V 60 A 50 A 40 A 30 A 25 A 20 A Very high reliability, designed for long life at full power Very low output ripple and spikes Redundant parallel operation with undervoltage alarm contact Screwdriver adjustable or analog programmable Parallel and series operation 19 rack mounting or wall mounting Convection cooling Remote sensing Models Voltage range Current range S 6-40 0-6 V 0-40 A S 15-18 0-15 V 0-18 A S 28-10 0-28 V 0-10 A Output programmable from zero till max. Very high reliability, designed for long life at full power Very low output ripple and spikes Screwdriver adjustable or analog programming Master / Slave parallel opera- 12-15 V 30 A 16 600 S 24 24 V 25 A tion with current sharing 17 30 V 20 A Optional with external interfaces Ethernet, IEEE488, RS232 or ISO AMP. Details about interfaces: Page 21-24 Euro rack mounting or wall mounting Redundant parallel operation with optional RA-10 adapter Convection cooling Remote sensing Height = 88 mm Width = 433 mm Depth = 385 mm Weight = 11 kg Height = 106 mm Width = 195 mm Depth = 166 mm Weight = 2,8 kg Single phase input : 198-264 V AC (48-62 Hz) 99-132 V AC (48-62 Hz) Power Factor Correction : up to 0.76 (at 100 % load) : up to 89% (at full load) : 7 mv rms / 20 mv pp : 10 mv (0-100% load step) : 300 µs (50-100% load step) Stability : 30.10-5 : up to 1.000.000 hrs Operating ambient temperature : -20 to +50 C, derate current linearly to 20% at 75 C Single phase input : 195-265 V AC (48-62 Hz) 100-132 V AC (48-62 Hz) : up to 88% (at full load) : from 5 mv rms / 25 mv pp : 5 mv (0-100% load step) Programming speed : from 10 ms (10 to 90%) Analog programming accuracy : from 0.2% Stability : 50.10-5 / 10.10-4 Operating ambient temperature : -20 to +50 C

240S Series 240 W DC power supplies SX Series 75 W / 150 W DC power supplies Very high reliability, designed for long life at full power Very low output ripple and spikes Models Voltage range Current range Very high reliability, designed for long life at full power Very low output ripple and spikes 75 SX 5 3.5-6 V 13 A 18 150 SX 5 3.5-6 V 26 A 19 75 SX 15-15 2 x 6-15 V 2.5 A 150 SX 15-15 2 x 6-15 V 5 A Model Voltage range Current range 150 SX 75-75 2x 15-75 V 1 A 12-15 V 12 A 150 SX 200-200 2x 35-200 V 0.3 A 240 S 24 24 V 10 A 3.5-6 V 13 A 30 V 8 A ST 150 2x 6-15 V 2.5 A Redundant parallel operation with under voltage alarm contact Screwdriver adjustable or analog programmable Parallel and series operation Bench operation with bench adapter (optional) Euro rack, 19 rack or wall mounting Convection cooling Remote sensing 2 outputs: series mode, parallel mode or dual mode Redundant parallel operation with external diodes Remote control with an external potentiometer Bench operation with bench adapter (optional) Euro rack, 19 rack or wall mounting Convection cooling Height = 240 mm Width = 71 mm Depth = 156 mm Weight = 2 kg 75SX Height = 100 mm Width = 36 mm Depth = 172 mm Weight = 0,6 kg 150SX Height = 233 mm Width = 36 mm Depth = 172 mm Weight = 1,2 kg Single phase input : 195-265 V AC (48-62 Hz) 100-132 V AC (48-62 Hz) : up to 87% (at full load) : 5 mv rms / 15 mv pp : from 10 mv (0-100% load step, external sensing) : 200 µs (50-100% load step) Stability : 30.10-5 : 1.000.000 hrs Operating ambient temperature : -10 to +50 C, derate current linearly to 20% at 80 C Single phase input : 185-264 V AC (48-62 Hz) 98-132 V AC (48-62 Hz) : up to 84% (at full load) : from 5 mv rms / 20 mv pp : from 10 mv (0-100% load step) Stability : 50.10-5 : 1.000.000 hrs Operating ambient temperature : -20 to +50 C, derate current linearly to 20% at 75 C

U Series 6 W DC power supplies PSC Series ethernet interfaces Very low output ripple and spikes (linear design) Voltage and current programming and monitoring Uses existing IP-networks Integrated sequencer Software calibration Isolated digital user in- and outputs Factory installed or external module Programming and monitoring resolution : 16 bit Model Linearity error : +/- 2 LSB (prg.) +/- 1 LSB (mon.) Very high reliability, designed PSC-ETH Ethernet Controller TC = 10 ppm/ C 20 for long life at full power Input voltage (external module) : 98-264 V AC (48-62 Hz) 21 Models Voltage range Current range 5 U 5 (voltage source) 5-6 V 1 A 5 U 15-15 (voltage source) 2 x 12-15 V 0.2 A UCS 50 (current source) 30 V 0-50 ma Single phase input : 230 / 115 V AC (48-62 Hz) : 0.5 mv rms / 2 mv pp for 5U5 and 5U15-15 30 µa pp for UCS50 : 5 mv (0-100% load step) for 5U5 and 5U15-15 3 µa (load 600-0 Ohm) for UCS50 Accurate 20 turn trimmer for adjusting output voltage (5U5, 5U15-15) or current (UCS50) Parallel and series operation Eurocard, rail or wall mounting Convection cooling Height = 35 mm Width = 58 mm Depth = 94 mm Weight = 0,4 kg : from 10 µs (10-100% load step) : 1.000.000 hrs Operating ambient temperature : -20 to +50 C External module : Generic Emission EN 61000-6-3 (EN55022B) Insulation in/outputs - case Interface: Monitoring status outputs: ACF, DCF, CC-mode, Over Temp, PSOL etc. Isolated user inputs (8) and outputs (6) Software calibration for offset and full scale 1000 V DC Integrated sequencer: Converts power supply into an arbitrary waveform generator Stand-alone automation like a PLC 25 free programmable sequences, 2000 steps each Combination of very fast and slow sequences Possibility to create loops, sub-routines, ramps etc. Dimensions and weight: Dimensions: 89 x 86 x 119 mm Weight: 0,7 kg Optional 19 rack mounting

PSC Series CANopeN & profibus interface PSC Series rs232 & ieee488 interfaces Voltage and current programming and monitoring Node address setting selectable Read back of power supply status signals 600 V galvanic isolation Factory installed Voltage and current programming and monitoring Up to 15 PSCs on one BUS Software calibration Isolated digital user in- and outputs Factory installed or external module Programming and monitoring resolution : 16 bit Models Programming and Models Linearity error : +/- 2 LSB (prg.) 22 monitoring resolution : 14 bit +/- 1 LSB (mon.) PSC-CAN CANopen Controller PSC-232 RS232 Controller Communication speed : up to 12Mbit/s for PSC-PB TC = 10 ppm/ C PSC-PB PROFIBUS Controller up to 1Mbit/s for PSC-CAN PSC-488 IEEE488 Controller Input voltage Full scale accuracy : < 0.1% (external module) : 98-264 V AC (48-62 Hz) 23 CANopen : SYNC Object Emergency Object Node Guarding Heartbeat Expedited and Nonexpedited SDO transfer Node address range 1-127 PROFIBUS : Slave in a PROFIBUS-DP network DP-V0 standard acc. IEC 61784 Ed. 1:2002 CPF 3/1 PROFIBUS protocol acc. IEC 61158 Slave address range 1-127 Monitoring status outputs: ACF, DCF, CC-mode, Over Temp, PSOL etc. Two isolated user inputs and outputs (external modules only) Software calibration for offset and full scale PSC-488 models can also be configured as PSC-232 External module : Generic Emission EN 61000-6-3 (EN55022B) Insulation input / output 1000 V rms Dimensions and weight: Dimensions: 89 x 86 x 119 mm Weight: 0,8 kg Optional 19 rack mounting

Analog Series ANAloG interfaces Model ISO AMP Isolated Analog Programming Selectable 0-5 V and 0-10 V signal levels Isolated programming and monitoring of U, I and status signals Prevents problems with earth loops and CM-voltages Factory installed or external module Programming and monitoring offset : +/- 60 µv typical Full scale error : 0.1% calibrated Non-linearity : 0.01% typical, TC = - 65ppm/ C Common mode rejection : 80 db @ 50 Hz 24 Model M / S - ADAPTER Master / Slave Series Adapter Connecting SM3000 and ES-series in M/S series mode Equal voltage sharing in series operation Series operation possible up to 600 V Programming and monitoring offset : +/- 60 µv typical Full scale error : 0.1% calibrated Non-linearity : 0.01% typical, TC = - 65ppm/ C Common mode rejection : 80 db @ 50 Hz Model AL 24-48 Under and Over Voltage Alarm Large adjustment for use on both 24 V and 48 V Two isolated comparator circuits with alarm contact and LED indication Monitors output voltage of 2 power supplies Undervoltage range : 18-48 V Overvoltage range : 24-64 V Insulation between circuits : 500 V DC Alarm contact : 100 ma / 30 V, Normally Closed

B.V. po Box 27 4300 AA Zierikzee The Netherlands Tel. +31 111 413656 Fax. +31 111 416919 Vissersdijk 4 4301 ND Zierikzee The Netherlands www.deltapowersupplies.com