Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Similar documents
Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive sensor BI5-EM18-Y1X-H1141

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Inductive sensor with analog output BI15-M30-LI-EXI

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

Fieldbus I/O module PROFIBUS-DP 16 configurable digital channels, as PNP inputs or 2 A outputs TBDP-L2-16DXP

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

Profibus-DPV1 Set in IP20 TI-BL20-DPV1-2

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O Module Programmable via CODESYS V3 with WebVisu License TBEN-L5-4RFID-8DXP-CDS-WV

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Compact multiprotocol I/O module for Ethernet 16 digital PNP outputs TBEN-L1-16DOP

TBEN-S Multiprotocol Module for Ethernet Compact RFID and I/O module TBEN-S2-2RFID-4DXP

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Compact Multiprotocol I/O Module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics TBEN-L5-8IOL

Compact multiprotocol I/O module for Ethernet 8 Digital PNP Inputs and 8 Digital PNP Outputs 2 A TBEN-LG-8DIP-8DOP

Ethernet spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-LG-EN1

Pneumatic Control/Feedback

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Pneumatic Control/Feedback

Compact multiprotocol I/O module for Ethernet 16 digital PNP inputs TBEN-L1-16DIP

Profinet Set in IP20 TI-BL20-E-PN-4

Programmable Set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-2

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

Compact multiprotocol I/O module for Ethernet 8 Digital PNP Inputs and 8 Digital PNP Outputs 2 A TBEN-L1-8DIP-8DOP

TBEN-L Multiprotocol Module for Ethernet Interface for 4 BL ident read/write heads (HF/UHF) TBEN-L5-4RFID-8DXP-CDS

Compact multiprotocol I/O module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2A Outputs TBEN-L1-16DXP

Compact multiprotocol I/O module for Ethernet 16 configurable digital channels pnp inputs / outputs 2 A FGEN-XSG

Sensor boxes SRBG Key features

Compact multiprotocol I/O module for Ethernet 8 universal digital channels, configurable as PNP inputs or 0.5 A outputs TBEN-S1-8DXP

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O module programmable via CODESYS V3 TBEN-L4-4RFID-8DXP-CDS

Technical Data. General specifications. Rated operating distance s n 3 mm

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs 8 digital outputs 2 A FGEN-IOM

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

Kit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8

Pneumatic Control/Feedback

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Outputs TBEN-L4-16DOP

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Expansion Module for I/O Communication BL Ident RFID Module for Connecting 2 Read/Write Heads (HF/UHF) BL20-2RFID-S

Ethernet Spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-L5-EN1

Compact multiprotocol I/O module for Ethernet 16 digital outputs 2 A FGEN-OM

BL compact Fieldbus Station for DeviceNet 4 Analog Current Outputs BLCDN-4M12LT-2AO-I-2AO-I

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

Set for EtherCAT in IP20 TI-BL20-E-EC-S-8

Compact Multiprotocol I/O Module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

Sensors with analog output

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as NPN Inputs or 2 A Outputs TBEN-L4-16DXN

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM

Compact Multiprotocol I/O Module for Ethernet 16 digital NPN Inputs TBEN-L4-16DIN

NAMUR INDUCTIVE SENSOR ATEX/IECEx

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Programmable Set for Simple I/O Communication via Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-S-6

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

IP 69K M12 I/O ports LEDs indicating status and diagnostics

Series 3730 Type Electropneumatic Positioner

Series 3730 Electropneumatic Positioner Type

IP 69K M12 I/O ports LEDs indicating status and diagnostics

PHOENIX CONTACT - 12/2007

Sense it! Connect it! Bus it! Solve it! INTERFACE TECHNOLOGY

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Current or Voltage Inputs BLCEN-8M12LT-4AI-VI-4AI-VI

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Thermocouple Inputs BLCEN-8M12LT-4AI-TC-4AI-TC

T EN TROVIS Electropneumatic Positioner

PHOENIX CONTACT - 05/2007

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Your Global Automation Partner. IM Interface Technology in Modular Housings

Product manual plug, sockets and coupler 16 A.- Z0251

Digital Positioner 8049

PHOENIX CONTACT - 01/2008

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Compact Multiprotocol I/O Module for Ethernet 4 IO-Link Master Channels 4 Universal Digital PNP Channels, 0.5 A, Channel Diagnostics TBEN-S2-4IOL

PI-EX-ME-2NAM/COC-24VDC

5 Fieldbus Technology

Type code. TBEN-S2-4IOL Ident no Supply. Total current max. 4A per voltage group

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

BL compact Multiprotocol Station for Industrial Ethernet 2 Analog Pt and Ni Sensor Inputs BLCEN-2M12MT-2AI-PT

Transcription:

ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting on all standard actuators DC 2-wire, nom. 8.2 VDC Type designation Ident no. 1051004 Rated switching distance Sn 4 mm Mounting conditions Non-flush Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy ð 2 % of full scale Temperature drift ð ± 10 % Hysteresis 1 10 % Ambient temperature -25 +70 C 2 outputs acc. to DIN EN 60947-5-6 (NA- MUR) Terminal chamber Wiring Diagram Output function 4-wire, NAMUR Valve control Exi (max. 30 V) Switching frequency 0.05 khz Voltage Nom. 8.2 VDC Non-actuated current consumption ï 2.1 ma Actuated current consumption ð 1.2 ma Approval acc. to Design Dimensions Housing material Active area material Electrical connection KEMA 02 ATEX 1090X dual sensor for rotary actuators,dsu35 62 x 60 x 35.4 mm Plastic, PP-GF30, Yellow Plastic, PP-GF30, black Terminal chamber Functional principle Inductive sensors detect metal objects contactless and wear-free. Dual sensors are especially designed for position detection in rotary actuators. They combine the reliability of non-contact inductive sensors with the flexibility of a modular housing system. Clamping ability ð 2.5 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Packaging unit 1 Switching state Included in delivery 2 LEDs,Yellow/Red 2 cable glands (blue), 1 blanking plug 1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply BTS-DSU35-EB1 6900225 Actuation kit (puck) for dual sensors; end position damped; hole pattern on flange surface 80 x 30 mm and 130 x 30 mm; connection shaft (shaft extension) height 20 mm / Ø max. 30 mm BTS-DSU35-Z01 6900229 Mounting kit dual sensors, for larger rotary actuators: Spacer plate and snap ring max. Ø 65 mm; hole pattern on flange surface 30 x 80 mm (30 x 130 mm); connection shaft (shaft extension) height 30 mm / Ø max. 30 mm BTS-DSU35-Z02 6900230 Mounting kit dual sensors, for larger rotary actuators: Ø disc and snap ring max. 65 mm; hole pattern on flange surface 30 x 80 mm (30 x 130 mm); connection shaft (shaft extension) height 20 (30) mm / Ø max. 40 mm BTS-DSU35-Z03 6900231 Mounting kit dual sensors, for larger rotary actuators: Ø disc and snap ring max.110 mm; hole pattern on flange surface 30 x 130 mm; connection shaft (shaft extension) height 30 mm / Ø max. 70 mm 3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description BTS-DSU35-Z07 6900403 Mounting kit dual sensors, for larger rotary actuators: Ø disc and snap ring max.110 mm; hole pattern on flange surface 30 x 130 mm; connection shaft (shaft extension) height 50 mm / Ø max. 75 mm BTS-DSU35-EBE3 6901070 Actuation kit (puck) for dual sensors; end position damped; "open" and "closed" switchpoint adjustable; hole pattern on flange surface 80 x 30 mm and 130 x 30 mm; connection shaft (shaft extension) height 20 / Ø max. 30 mm BTS-DSU35-EU2 6900455 Actuation kit (puck) for dual sensors; end position undamped for clockwise and counter-clockwise drives; hole pattern on flange surface 80 x 30 mm and 130 x 30 mm; connection shaft (shaft stud) height 20 (30) mm / Ø max. 30 mm 4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 2 G and II 1 D (Group II, Category 2 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 2 G and Ex ia IIC T6 Gb and É II 1 D Ex ia IIIC T95 C Da acc. to EN 60079-0, -11 Local admissible ambient temperature -25 +70 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation avoid static charging Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com