Syr-line TMR48D Digital Timer

Similar documents
Syr-line TMR48D Digital Timer

02/11/2015

02/11/2015

08/07/2015

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

02/11/2015

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

Solid-state Timer H3YN

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

812/ 814/ 815 digital timers

Contact protection relay

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Zelio Count - Counters RC87610

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

TM3DI16 module TM3-16 inputs

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XPSMCMDO Digital output pairs expansion modules with screw term

Technical specifications

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

XPSMCMDI Input expansion module with screw term

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Electronic timer CT-ERD.12

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Electronic timer CT-ERS.21

RM35TF V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

TM3AI4 module TM3-4 analog inputs

02/11/2015

RZ7-FE Electronic Timing Relays

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TM3DI16G module TM3-16 inputs spring

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Model Number Structure

RM35LM33MW liquid level control relay RM35-L V AC/DC

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

TM221M32TK controller M IO transistor PNP

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

TM221M16R controller M IO relay

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Output Voltage* (nom.)(adjustable)

Electronic timer CT-AHD.22

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

TM221M16TG controller M IO transistor PNP spring

Electronic timer CT-ARS.11

RM35LM33MW liquid level control relay RM35-L V AC/DC

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

TM3TI4 module TM3-4 inputs temperature

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

Programmable Relay ZEN V2 Units

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

TM200C24R controller M IO relay

TM3TI8T module TM3-8 inputs temperature

Output Voltage* (nom.)(adjustable)

Transcription:

yr-line MR48D Digital imer Front Panel 48x48 (1/16 DIN) Large LED or LCD creen (13.2 mm) Multi-function and single-function Basic & Advance configuration modes Multi-range (0.05s-9999h) Multi-voltage (24-240V AC/DC) 1 or 2 relay outputs (Changeover) Memory option in event of a break in supply Lock function p or down timing DIN ized (48x48mm) Housing Compact body (63mm long) Water & Dust-proof (IP66) 8-Pin & 11-Pin connections tandard Version (MDE1) Performance Version (MDA2, MDF1, GDF1, GD2) Product election ype Part Number Function Connections Output upply Voltage creen MDE1 MDE1R0524 A, B, C, H, D, Di 8-Pins 1 x 5A 24V AC/DC LCD MDE1 MDE1R05MVA A, B, C, H, D, Di 8-Pins 1 x 5A 100-240V AC/DC LCD MDA2 MDA2R10MV2 A 8-Pins 2 x 10A 24-240 VAC/DC LED MDF1 MDF1R10MV2 A, Ac, Ad, B, C, H, L, Li, D, Di 8-Pins 1 x 10A 24-240 VAC/DC LED GDF1 GDF1R10MV2 A, Ac, Ad, B, C, H, L, Li, D, Di 11-Pins 1 x 10A 24-240 VAC/DC LED GD2 GD2R10MV2 A, Ab, Ac, Ad, AMt, At, B, C, H, Ht, L, Li,, W, D, Di 11-Pins 2 x 10A 24-240 VAC/DC LED Function A: ON-Delay E: Multifunction E F: Multifunction F : Multifunction Output ype R: Relay Power upply MV2: 24-240V AC/DC MVA: 100-240V AC 24: 24V AC/DC GD 2 R 10 MV2 ype MD: ON-Delay GD: Multifunction E Output Quantity 1: 1 Output 2: 2 Outputs Output Power 10: 10A 05: 5A Description: he new yr-line Digital imers has higher precision and many programming features with the biggest screen ever seen in the timer relays market and the most intuitive programming for ease to use and fast configuration For more information about the yr-line MR48D Digital imer please visit www.crouzet.com.

CONROL.CROZE.COM 2 DIGIAL IMER Input pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Rated supply voltage n 24V AC/DC 100-240V AC/DC 24 to 240 V AC/DC Voltage supply tolerance -15 %, +10 % 24 to 240 V AC/DC AC supply voltage frequency 50 / 60 Hz +/- 5% Galvanic isolation of supply / inputs Max power consumption @ n Immunity to power micro cuts No 2.5 VA (VAC) 1 W (VDC) 10ms 24 to 240 V AC/DC 24 to 240 V AC/DC iming pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 pecified time ranges (10) Minimum control pulse duration Recovery time (after by de-energization) Repeatability etting Accuracy emperature drift Voltage drift IEC 1812-1: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s, 1 to 9999 s, 1 s to 99, min 59 s, 0.1 to 999.9 min, 1 to 9999 min, 1 min to 99 h 59 min, 0.1 to, 999.9 h, 1 to 9999 h IEC 1812-1: 20ms for DC, 30ms for AC IEC 1812-1: 120 ms Max IEC 1812-1: ± 0,03 % ± 20 ms (VDC) / 50 ms (VAC) IEC 1812-1: ± 0,03 % ± 20 ms (VDC) / 50 ms (VAC) ± 0,03 % ± 20 ms (VDC) / 50 ms (VAC) ± 0,03 % ± 20 ms (VDC) / 50 ms (VAC) Output pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Contact arrangement 1 CO (PD) 1 CO (PD) 2 CO (PD) Maximum switching voltage 250 V AC / 30 VDC 250 VAC/ 10 A resistive / 125 VDC / 0.3 A resistive 250 VAC/ 10 A resistive / 125 VDC / 0.3 A resistive witching current rate (resistive) NO: 5A 250 V AC / 5 A 30 VDC - NC: 3A 250 V AC / 3 A 30 VDC NO / NC: 10A 250 V AC / 10 A 30 VDC NO/NC: 2x10A@40 C 250V AC / 2x10 A@40 C 30 VDC NO / NC: 2x8A @60 C 250 V AC / 2x8A@60 C 30 VDC Maximum switching power (resistive) NO: 1,250 VA / 150 W NC: 750 VA / 90 W 2500 VA / 300 W 2 x 2500 VA / 2 x 300 W Electrical life at nominal switching current rate (resistive) 10 5 cycles NO 7.10 4 cycles NC 1 x 10 5 cycles (10A 250VAC resistive) 1 x 10 5 cycles (10A 250VAC resistive) Minimum switching contact 10 ma / 12 VDC Maximum rate (at max switching power) 360 cycles /hour Mechanical life 10 x 10 6 cycles Rated impulse voltage IEC 60664-1: 5 kv (1.2/50μs) Dielectric strength between coil / contacts Dielectric strength between open contacts IEC 60664-1: 2.5 kv /1 min / 1 ma / 50 Hz 1 kv /1 min / 1 ma / 50 Hz

CONROL.CROZE.COM 3 DIGIAL IMER Insulation pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Rated Insulation voltage IEC 60664-1: 300V Insulation coordination IEC 60664-1: Overvoltage category III; pollution degree 2 Rated impulse voltage Clearance / Creepage distances Dielectric strength Insulation Resistance IEC 60664-1: 4 kv (1.2/50μs) IEC 60664-1: 3 mm / 3.2 mm EN-61812-1: 2.5 kv /1 min / 1 ma / 50 Hz NFC 93 050: > 500 MΩ / 250Vdc / 1min General pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Display 4 digits per value 7 segments LCD 4 digits per value 7 segments LCD 4 digits per value 7 segments LCD with backlight 4 digits per value 7 segments LCD with backlight 4 digits per value 7 segments LCD with backlight 4 digits per value 7 segments LCD with backlight Memory backup Casing Mounting position Mounting Housing material Degree of protection (Front Face) Degree of protection (Housing) Operating temperature torage temperature EEPROM (rewrite 1,000,000 times min, 40 years data hold min) 48x48 mm (1/16 DIN) All positions Mounting Front panel, by clip Mounting base-mounted on socket L94: enclosure plastic type V0 IEC 60529: IP66 with front panel seal IEC 60529: IP20 IEC 60068-2: -10 C to +60 C IEC 60068-2: -30 C to +70 C Humidity Vibration resistance hock resistance IEC 60068-2-30: 93 % without condensation IEC 60068-2-6: ±0.15mm from 10Hz 60Hz 2g from 60Hz.150Hz IEC60068-2-27: 15gn - 11ms; 3 X 6 axis (Output non-energized) 5gn - 11ms; 3 X 6 axis (Output energized) Drop to concrete floor IEC 60068-2-32: High: 0.75m Weight Approx. 105g (150g with packing)

CONROL.CROZE.COM 4 DIGIAL IMER tandards pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 CEE Directive Approvals / Marking ecurity standard Conformity with environmental directives Product standard Immunity to electrostatic discharges Immunity to radiated, radio-frequency, electromagnetic field Immunity to rapid transient bursts Immunity to shock waves on power supply Immunity to radiofrequency in common mode Immunity to voltage dips and breaks AC/DC main port emissions Radiated emissions 2014/30/E: EMC, 2014/35/E: Low voltage CE, clus Listed Industrial Control Equipment IEC 60664-1: Insulation coordination for equipment within low-voltage systems 2015/863/E: RoH 1907/2006: Reach 2012/19/E: WEEE IEC 61812-1: pecified time relays for industrial use L 508 (60947-4-1): Industrial Control Equipment (NRN- Industrial Control witches) Level III Air +/-8 KV / Contact +/-6 KV IEC61000-4-3: Level III, 10V/m (80 MHz to 1 GHz) 80% AM (1 khz), 3 V/m (1,4 to 2 GHz) 80% AM (1KHz), 1 V/m (2 to 2.7 GHz) 80% AM (1KHz) IEC 61000-4-4: Level IV, direct +/-4kV (power supply) / capacitive coupling clamp +/-2 KV, (command input and outputs) IEC 61000-4-5: Level III, line-to-earth +/-2kV / line-to-line +/-1kV IEC 61000-4-6: Level III, 10Vrms (0,15 to 80 MHz) 80% AM (1 khz) IEC 61000-4-11: Industrial Class II, 0 % residual voltage during 1 cycle a.c.power ports, 70 % residual voltage during 25/30 cycles a.c. power ports, 0 % residual voltage, 250/300 cycles a.c. power ports. Residential: 0 % residual voltage during 10 cycle a.c.power ports, 40 % residual voltage during 10 cycles a.c. power ports, 70 % residual voltage during 10 cycles a.c. power ports, 0 % residual voltage, 250/300 cycles a.c. power ports EN55022 / CIP2 Class B EN 55011 / CIPR11 Class B, Group 1 EN55022 / CIP2 Class B EN 55011 / CIPR11 Class B, Group 1

CONROL.CROZE.COM 5 DIGIAL IMER Accessories ocket for DIN Rail or Panel Mount ocket for DIN Rail or Panel Mount ocket with crew erminal Plug-In 8-Pin Plug-In 11-Pin Plug-In 8-Pin 25 622 130 25 622 080 25 622 203 older Plug older Plug ocket with crew erminal Plug-In 8-Pin Plug-In 11-Pin Plug-In 11-Pin 25 622 301 25 622 076 79 694 002

CONROL.CROZE.COM 6 DIGIAL IMER Diagrams Wiring Diagrams MDE1 24 MDE1 MVA MDF1 GDF1 MDA2 GD2

CONROL.CROZE.COM 7 DIGIAL IMER Dimensions in(mm) ide View Front View Mounting Panel Cut-Out

CONROL.CROZE.COM 8 DIGIAL IMER Function Diagrams Basic ime Chart A FNCION A: On-Delay (Delay on make) IN BAIC IME CHAR R1/ IN Detailed ime Chart DEAILED IME CHAR NO ED R1/ t FNCION A + Memory Option BAIC IME CHAR DEAILED IME CHAR NO ED R1/ IN R1/ IN t1 t2 FNCION Ab: Delayed Interval BAIC IME CHAR DEAILED IME CHAR Ab R1 / BAIC IME CHAR R1/ IN 1 2 IN 1 2 1 t 1 t 1 2 FNCION Ab IMED + Memory R1 / Option IN DEAILED IME CHAR 1 2 R1/ R1/ IN 1 2 IN 1 2 1 t1 t2 1 t 1 2 1 2 FNCION Ac: On/Off Delay (Delay on make/break) BAIC IME CHAR Ac R1 / R1 / IN BAIC IME CHAR IN 1 2 1 t2 2 t1 t1 1 t1 1 R1 / IN 1 2

CONROL.CROZE.COM 9 DIGIAL IMER FNCION Ac + Memory Option R1 / R1 / IN 1 2 IN t2a+t2b=2 1 t2 t2a t2b t t 1 t 1 2 1 FNCION Ad: Delay on Ad R1 / R1 / IN IN t1 t1 FNCION Ad + Memory Option R1 / R1 / IN IN t1 t2 =t1+t2 FNCION At: ummation ime Relay At R1 / R1 / IN IN =t1+t2 t1 t2 =t1+t2 t1 t2 t1 t2 FNCION At + Memory Option R1 / R1 / IN IN =t1+t2 t1 t2 =t1+t2 t1 t2 t1 t2 t1 t2

CONROL.CROZE.COM 10 DIGIAL IMER FNCION AMt: On-Delay (Delay on make, otal memory: one delay) NO ED AMt R1 / R1 / IN =t1+t2 t1 t2 IN t1 t2 FNCION B: One-hot =t1+t2 B R1 / R1 / IN IN t t FNCION B + Memory Option R1 / R1 / IN IN =t1+t2 t t1 t2 FNCION C: Off-Delay (Delay on break) C R1 / R1 / IN IN t t FNCION C + Memory Option R1 / R1 / IN IN =t1+t2 t t1 t2 t

CONROL.CROZE.COM 11 DIGIAL IMER FNCION H: Interval H IN R1 / R1 / NO ED IN t t FNCION H + Memory Option NO ED R1 / IN R1 / IN = t1 + t2 t t1 t2 FNCION Ht: interval summation time relay Ht R1 / R1 / IN =t1+t2 t1 t2 IN =t1+t2 t1 t2 t1 t2 FNCION Ht + Memory Option R1 / R1 / IN =t1+t2 t1 t2 IN =t1+t2 t1 t2 t1 t2 t1 t2 FNCION L: Recycler (OFF ) NO ED L IN R1 / 1 2 1 2 R1 / IN 1 2 1 2 1 1 2 1 1

CONROL.CROZE.COM 12 DIGIAL IMER FNCION L + Memory Option NO ED R1 / IN R1 / 1 2 1 2 IN 1 = t1 + t2 1 2 1 2 t1 t2 2 1 1 t FNCION Li: Recycler (ON ) NO ED Li IN R1 / 1 2 1 2 R1 / IN 1 2 1 2 t 1 2 1 t 1 FNCION Li + Memory Option NO ED R1 / IN R1 / 1 2 1 2 IN 1 = t1 + t2 1 2 1 2 t1 t2 2 1 t 1 t FNCION : On-Delay (Delay on make): sum of times R1 / R1 / IN = t1 + t2 + t3 t1 t2 t3 FNCION + Memory Option IN = t1 + t2 + t3 t1 t2 t3 t1 t1 t2 t3 R1 / R1 / IN = t1 + t2 + t3 t1 t2 t3 IN = t1 + t2 + t3 t1 t2 t3 t1 t2a t2b t2 = t2a + t2b t3

CONROL.CROZE.COM 13 DIGIAL IMER FNCION W: iming after pulse of control contact W R1 / R1 / IN IN t t FNCION W + Memory Option R1 / R1 / IN IN 1 = t1 + t2 t t1 t2 FNCION D: ymmetrical flashing (OFF start) D IN R1 / R1 / NO ED IN 1 FNCION D + Memory Option NO ED R1 / IN R1 / IN = t1 + t2 t1 t2 t FNCION Di: ymmetrical flashing (ON start) Di IN R1 / R1 / NO ED IN t t

CONROL.CROZE.COM 14 DIGIAL IMER FNCION Di + Memory Option NO ED R1 / IN R1 / IN = t1 + t2 t1 t2 t t Keys Function et ime Check Configured ime and Function ime Programming Mode

CONROL.CROZE.COM 15 DIGIAL IMER Programming Mode Programming Main Menu # Parameter Value 1 Pass If "Lock" function is on, pass needs to be entered 0000 2 Basic Prog Enter to Basic Programming Mode 3 Advanced Prog Enter to Advanced Programming Mode 4 est Enter to est Mode Basic Prog Menu # Parameter Value 1 Function elect the timing function A Ab Ac Ad AMt At B C H Ht L Li D Di W 2 ime Range elect the timing range -.---s --. s ---.-s ----s --m--s ---.-m ----m --h m ---.-h ----h 3 Count elect the timing count up or down p Down 4 Memory Activate memory option (save timing after power off) Off On 5 Output 2 elect if Out 2 works timed or instantaneous (MDA2, GD2) imed Instantaneous Advanced Prog Menu # Parameter Value 1 Input ime elect input time wave 0.020s 0.001s 2 Input ype elect input to work with a NPN or PNP signal PNP NPN 3 ime Limit elect upper time limit 9999 0000

CONROL.CROZE.COM 16 DIGIAL IMER 4 Brightness elect screen brightness 100% 50% 5 leep After elect the time needed to turn off the screen Off 5s 10s 30s 60s 6 Lock elect security level 1 (lock configuration) or 2 (lock all) Off 1 2 6.1 Pass et password for lock option 0000 6.2 Done Indication that the lock is on 7 Default ettings settings to default values No Yes 7.1 ure Confirm if reset settings to default values No Yes 7.2 Done Indication that settings have been reset est Mode Menu # Parameter Value 1 Out 1 urn on/off Relay Output 1 Off On 2 Out 2 urn on/off Relay Output 2 (MDA2, GD2) Off On 3 Display urn on/off all display segments Off On 4 Memory est the memory of the timer Off est 4.1 Good Indication that the memory is working properly 4.2 Error Indication that the memory is not working properly All specifications in this document are subject to change without written notice. Actual product may differ from pictures provided in this document.