Datasheet IQ Modular Enclosures Flexible and Reliable Video and Audio Backbone

Similar documents
Installation and User Manual IQH3A. IQ 3U Modular Enclosure. snellgroup.com

NV9000 Control System NV920S NV920D. NV960/NV965/NV967 Router Controllers NV960 NV965 NV967

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

HMP-1801 HD/SD Solid-State Media Server

Datasheet EdgeVision Multichannel Quality of Experience Monitoring

Compact SDI Routers KUMO 1604 KUMO 1616 KUMO CP

B e c a u s e i t m a t t e r s. B e c a u s e i t m a t t e r s.

Prisma II Platform. Optoelectronics

Cisco Prisma II Platform

Datasheet Imagestore 750 HD/SD Master Control and Branding Processor with Advanced Audio Processing

EMC1600 Series Media Converter and Ethernet Extender Chassis

VXrouters. The worlds first fiber optic, non-blocking, 6.25 Gbps Video and Peripheral Router! VX Router Series.

Specifications FOX Matrix 3200/7200/14400/320x Series, SMX 88/1616 FOX

16x16 Modular Matrix Switch VM1600

Preparing Two T2 iddrs for Synchronized 4K Playback. Hiroshi Kobayashi January 2015

User Manual Controller. Automation and Router Control.

Gmux Modular TDMoIP Gateway FEATURES

K2 Media Server & Storage Platform

Cisco TelePresence MSE 8000

Datasheet Vertigo XG Advanced HD/SD Graphics Processor

Eight frames in three different sizes provide stylish and practical housing for Crystal Vision s Indigo modular product range

32 x 32 Modular Matrix Switch

Separate Video from Audio and Peripheral Data

16x16 Modular Matrix Switch VM1600A

Cisco D9036 Modular Encoding Platform

16x16 Modular Matrix Switch VM1600A

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Datasheet NVISION Panel Series

Cisco D9036 Modular Encoding Platform

Host Controller: HST-4002

AVP 3000 Voyager Configuration Packs

Datasheet Vertigo XG Advanced HD/SD Graphics Processor

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Settings for Timecode Chasing for T2 Express/Pro/Elite April 2015

NV6000 and NV8000 Series Universal Routers User Guide

Dell MD1280 Storage Enclosure Getting Started Guide

Summit Virtual Chassis Design and Installation Guide

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

The EDIUS OFX Bridge. December 2017

Brocade ICX 6610 Switch

DL-HDM44A-H2 Quick Install Guide

1U Device Expansion Unit Configuration Guide

ARCHITECTURAL SPECIFICATIONS

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

K2 Summit PVS Migration Bob Richardson, Product Manager Grass Valley, a Belden Brand, Editing, Servers & Storage July 2011

Acme Packet Net-Net 14000

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

KUMO. Compact SDI Routers

Dual Channel Universal HD/SD Audio/Video Frame Synchronizer and Format Converter

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

GigaVUE-2404 // Data Sheet

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

Main Frame (SMP-xx and MP-xx MultiViewers) Frames

ISILON HD-SERIES. Isilon HD400 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

Datasheet Kaleido-XQUAD Simplified Standalone Quad-Split Multiviewer with Dual Quad-Split Upgrade Capability

SmartAudio: SSA Feature Summary

AMU1-CHD+MK2 AUDIO MONITORING UNIT

PTP 810i ALL-INDOOR SOLUTIONS

SFR04 SFR08 SFR18. 4, 8 and 18 slot Synapse frame. A Synapse product COPYRIGHT 2016 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Orion X Digital KVM Switch

MediaKind G7 Series. High Performance Intel-based Video Processing

DVBS November 13, (12)

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

Orion XC Digital KVM Switch

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SUN BLADE 6000 CHASSIS

Dell SC7020 Storage Controller Getting Started Guide

High Definition Broadcast Server BROADCAST

CONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES

Using EDIUS to Prepare 4K (QFHD) Material for Playback on Two T2 iddrs. Fumiaki Ogura January 2015

Savant Host Controller: SVR-4100

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Cisco Redundant Power System 2300

Compact Redundancy Switch 2:1 RSCC-2

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

DP400 HD-SDI to SDI Encoder/Decoder using DIRAC PRO by NuMedia

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Infoblox Reporting and Analytics Appliances

Orion XC Digital KVM Switch

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Cisco Nexus 9500 Series Switches

Pro. LCN1840/05 Wireless gateway. Specification sheet. Connected lighting. Find out more about Interact

3+1 U CPCI Serial System

Optimux-34 Fiber Optic Multiplexer

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

The EDIUS OFX Bridge. March 2016

Savant Host: HST-4501

LDX/K2 Dyno Universe. LDX 86N/LDX 86 Universe System Camera. K2 Dyno Universe Replay System

System Specifications

D9408 Advanced ATM Adapter

GigaVUE-420 // Data Sheet

Compact Redundancy Switch 2:1 RSCC-2

TECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications

Transcription:

Datasheet IQ Modular Enclosures Flexible and Reliable Video and Audio Backbone Flexible and reliable video and audio backbone for all types of video and audio signals. The IQ Modular range provides a comprehensive, reliable and cost-effective interfacing and processing solution for any broadcast infrastructure project. Handling all types of video and audio signals, IQ Modular provides industry leading packing density with new RU IQ high power frame and multi-channel modules enabling 0 channels of powerful video and audio processing and conversion, or 80 channels of SDI distribution with 0 outputs. IQ Modular is equally at home with IP, coax, fiber or any common interface standard, and its modular approach means that it is easily scalable and upgradeable as your needs change. New enhancements to the series include IP to SDI interfaces and modules supporting Grass Valley s unique Media Biometrics technology for network wide confidence monitoring, from basic error detection to more subtle issues such as logo or lipsync matching. With over 0,000 modules already in service worldwide, IQ Modular is a proven reliable, comprehensive system trusted by broadcasters both large and small. Build what you need With hundreds of modules providing a range of functionality, complex systems are possible with advanced control and monitoring systems keep everything running smoothly with minimal intervention. www.grassvalley.com

IQHB IQ RU Modular Enclosure IQHB enclosures offer industry-leading, high-density delivery of modular solutions, primarily for use with IP modules. With up to 00W of module power available this RU enclosure accepts up to 0 modules, has dual redundant PSUs and in-service replaceable cooling fans. Analog reference signals can be distributed through the enclosures via two connections that can be independently selected by the installed modules. RollCall control and monitoring is included as standard using a Gateway control card that has its own module-style rear connector, thus providing a future-proof upgrade path as communication standards evolve. Full SNMP control and monitoring functionality is also available over Ethernet. KEY FEATURES 0 single- or 0 double-width modules (or any combination) Integrated web browser-based RollCall configuration and control SNMP control and monitoring of ALL RollCall-enabled IQ modules as standard Dual redundant network architecture over Ethernet and RollNet enables mission critical control applications to function even if a complete network failure occurs Plug-in gateway communications card to enable RollCall via RollNet, RS-/8/ and RollCall over TCP/IP control, with support for upgradeable connectivity to handle future communication standards x analog reference signal distribution for dual standard (Bi-Level or Tri-Level), dual video standard (SD or HD), and reference redundancy applications (Note: Only applicable to modules with -B order codes) Hot swappable redundant power supplies and in-service replaceable fan units Optimum use of rack space frames do not require any additional ventilation spacing Variable fan speed, dependent upon load and ambient temperature Full chassis monitoring, including inlet and outlet temperature, PSU, fan and module status Full CE and UL compliance IQHB HTTP-based frame status overview. IQHB RollCall control panel view. www.grassvalley.com

IQ Modular Enclosures Flexible and Reliable Video and Audio Backbone SPECIFICATIONS Inputs, Outputs and Controls Inputs/Outputs RollCall remote control: BNC connector RS-//8 remote control: 9-pin D-Type connector RollCall/SNMP over TCP/IP: 0/00baseT Ethernet Preset Controls Unit address code set switches: Hex switches 0 to F Communications mode switch: Select RS-, RS- or RS-8 interface Additional Controls via RollCall Remote Control System Full control via web browser-based Java RollCall control panel (available from chassis), any hardware RollCall control surface or standard RollCall Control Panel PC Application. General Specifications Module complement: 0 double-width or 0 single-width (or combinations of both) fitted vertically Module card dimensions: 00 x 0 mm (.9 x. in.) (WxL) Module rear panel dimensions: Height: 9 mm (. in.) Double width 0. mm (. in.) Single width: 0 mm (0.8 in.) Power Input voltage range: 00-0V 0/0 Hz Input connector: IEC0 C Power consumption: 000 VA maximum Modules power dissipation: 00W/00 LU maximum Output: +V and -.V ±% Note that all modules have built-in power supply fuses. CE Performance Information Environment: Commercial and light industrial E immunity, controlled EMC E emissions Peak mains inrush current following a second mains interruption: A @ 0 VAC Reference Analog reference: x analog reference inputs Black (HD tri-level and SD bi-level) and blackburst (SD bi-level) SD bi-level RS0A HD tri-level SMPTE ST 0, SMPTE ST and SMPTE ST 9 Connector/format: BNC/Ω panel jack Analog reference return loss: SD bi-level > -0 db to. MHz HD tri-level > -0 db to 0 MHz Mechanical Temperature range: 0 to 0 C ( to 0 F) operating, -0 to +8 (- to 8 F) storage. A temperature- and load-sensitive cooling fan is fitted Humidity range: 0 to 8% (non condensing) Case type: RU rack mounting aluminum case Dimensions: Width: 8 mm (9.0 in.) ( mm (. in.) behind rack location bracket) Depth: 8 mm (9. in.) Height: 80 mm (. in.) Weight: Approximately kg (8. lbs.) without modules. Approximately kg (8. lbs.) fully populated ORDERG IQHB-S-P Enclosure with Dual Redundant PSU and Ethernet/SNMP Compatible RollCall Gateway Card. 0 module slots. Accessories IQHB-PSU Single PSU for use as a cold spare or replacement. IQHB-FAN Dual Fan unit for use as a cold spare or replacement IQHB-E-GATEW Ethernet/SNMP compatible RollCall Gateway card for IQHB and IQHB enclosures. Note: Although IQ modules are interchangeable between enclosures, their rear panels are enclosure specific. Code A or B order codes may be used when installing modules in the IQHB and IQHB enclosures. Code A order codes must be used when installing modules in the IQHA enclosures. www.grassvalley.com

IQHB IQ RU Modular Enclosure IQHB enclosures offer industry-leading, high-density delivery of modular solutions. The RU enclosure accepts up to modules, and has dual redundant PSUs and cooling fans. Analog reference signals can be distributed through the enclosures via two connections that can be independently selected by the installed modules. RollCall control and monitoring is included as standard using a Gateway control card that has its own module style rear connector, thus providing a future-proof upgrade path as communication standards evolve. Full SNMP control and monitoring functionality is also available over Ethernet. KEY FEATURES single or 8 double-width modules (or any combination) Integrated web browser based RollCall configuration and control SNMP Control and Monitoring of all RollCall enabled IQ modules as standard Dual redundant network architecture over Ethernet and RollNet enables mission-critical control applications to function even if a complete network failure occurs Plug-in gateway communications card to enable RollCall via RollNet, RS-//8 and RollCall over TCP/IP control, with support for upgradeable connectivity to handle future communication standards x analog reference signal distribution for dual standard (bi-level or tri-level), dual video standard (SD or HD), and reference redundancy applications (Note: Only applicable to modules with -B order codes) Hot-swappable redundant power supplies with PSU status reporting through GPIs on the Gateway control card rear panel Optimum use of rack space frames do not require any additional ventilation spacing Dual redundant in-service removable fan unit Variable fan speed, dependent upon load and ambient temperature Full chassis monitoring, including inlet and outlet temperature, fan condition and module status Full CE and UL compliance IQHB HTTP-based frame status overview. IQHB Web browser-based Java RollCall control panel. www.grassvalley.com

IQBDDA S-A-B IQBADX -A-B -A IQBADI -A-D -A IQBDDA S-A-B IQBADX -A-B -A IQBADI -A-D -A A B IQBDAS -A-R-D IQ Modular Enclosures Flexible and Reliable Video and Audio Backbone SPECIFICATIONS Inputs, Outputs and Controls Inputs/Outputs RollCall remote control: BNC connector RS-//8 remote control: 9-pin D-Type connector RollCall/SNMP over: TCP/IP 0/00base-T Ethernet Preset Controls Unit address code set switches: hex switches 0 to F Communications mode switch: Select RS-, RS- or RS-8 interface Additional Controls via RollCall Remote Control System Full control via web browser based Java RollCall control panel (available from chassis), any hardware RollCall control surface or standard RollCall Control Panel PC Application General Specifications SDI module complement: 8 double width or single width (or combinations of both) fitted vertically IP module complement (all double width): IQUCP: IQMIX: IQUCP0: Module card dimensions: 00 mm wide, 0 mm long (.9 in. wide,. in. long) Module rear panel dimensions: Height: 9 mm (.0 in) Double width: 0. mm (. in.) Single width: 0 mm (0.8 in.) Power Input voltage range: 00-0 V 0/0 Hz Input connector: IEC0 Fused A(T) Standby switch: Behind drop-down front panel Power consumption: 00 VA maximum Modules power dissipation: 0W/ LU maximum (00 LU for IQHBQ) Output: +.V and -.V ±% Note that all modules have built-in power supply fuses. CE Performance Information Environment: Commercial and light industrial E immunity, controlled EMC E emissions Peak mains inrush current following a second mains interruption: 0A Reference Analog reference: x analog reference inputs Black (HD tri-level and SD bi-level) and blackburst (SD bi-level) SD bi-level RS-0A HD tri-level SMPTE ST 0, SMPTE ST and SMPTE ST 9 Connector/Format: BNC/Ω panel jack on standard IQ connector panel Analog reference return loss: SD bi-level > 0 db to. MHz HD tri-level > db to 0 MHz Mechanical Temperature range: 0 to C ( to F) operating, -0 to +8 C (- to 8 F) storage. A temperature- and load- sensitive cooling fan is fitted Humidity range: 0 to 8% (non condensing) Case type: RU rack mounting aluminum case Dimensions: Width: 8 mm (9.0 in.) ( mm. in.) behind rack location bracket) Depth: 90 mm (9. in.) Height: mm (. in.) Weight: Approximately 8. kg (8. lbs.) without modules Approximately kg (. lbs.) fully populated Please refer to the IQHB and respective IQ module Operators Manuals to determine the module power rating limits (PR) for your required configuration. In the IQHB Enclosure power is quoted in Load Units (LU), which refers to power (in watts) taken from the positive rail. The IQHB has power loading (LU) units available for modules. The power ratings of each module should be added together and the total should not exceed loading units. Modules that do not specify a power rating should use the total power figure (W) as a power rating value. ORDERG IQHB-S-0 Enclosure with Single PSU and Ethernet/SNMP Compatible RollCall Gateway Card. module slots IQHB-S-P Enclosure with Dual Redundant PSU and Ethernet/SNMP Compatible RollCall Gateway Card. module slots IQHB-SQP 00 load unit quiet enclosure with Dual Redundant PSU and Ethernet/SNMP Compatible RollCall Gateway Card. module slots AES AES OUT ANALOG AUDIO OUTPUTS AES AUDIO OUTPUTS OUT OUT AUDIO + AES OUT AES AES OUT ANALOG AUDIO OUTPUTS AES AUDIO OUTPUTS OUT OUT AUDIO + AES OUT ANALOG + OUT ANALOG + OUT Accessories IQHB-PSU Single PSU as cold spare or upgrade to dual PSU configuration IQHB-FAN Dual Fan unit for use as cold spare or replacement IQHB-E-GATEW Ethernet/SNMP compatible RollCall Gateway card for IQHB enclosures. Note: Although IQ modules are interchangeable between enclosures, their rear panels are enclosure specific. Code A or B order codes may be used when installing modules in the IQHB enclosure. Code A order codes must be used when installing modules in the IQHA enclosures. www.grassvalley.com

IQHA IQ RU Modular Enclosure The IQHA enclosure offers high-density delivery of HD and SD modular solutions. The RU enclosure accepts up to four A & now B single-width style SDI modules, two double-width style SDI modules or one double-width IP style module. The IQHA is available with hot-swappable dual redundant PSUs for maximum reliability. The enclosure is fitted with RollCall control and monitoring as standard, including full SNMP control and monitoring functionality over Ethernet. KEY FEATURES Four single-width or two double-width modules (or any combination) Capable of accepting all types of IQ modules including HD-SDI, SD- SDI, AES and analog audio, analog video and fiber optics Dual redundant power supplies (hot swappable) for high system availability Optimum use of rack space frames do not require any additional ventilation spacing Plug-in RollCall enabled via gateway card with TCP/IP, RollNet, SNMP and RS-//8 connectivity In service replaceable cooling fans Chassis monitoring, including inlet temperature, fan condition and module status Full CE and UL compliance Able to house a single IP module such as IQMIX or IQUCP, ideal for space constrained applications needing IP connectivity SPECIFICATIONS Inputs, Outputs and Controls Inputs/Outputs RollCall remote control: BNC connector RS-//8 Remote control: 9-pin D-Type connector RollCall/SNMP over TCP/IP 0/00base-T Ethernet Preset Controls Unit address code set switches: Hex switches 0 to F Communications mode switch: Select RS-, RS-8 or RS- interface Additional Controls via RollCall Remote Control System Full Control via RollCall Control Panel PC Application General Specifications Number of modules that may be accommodated: RU: double-width or single-width SDI (or combinations of both) fitted horizontally. For IP, a single IP module such as IQMIX, IQMIX0, IQAMD0 or IQUCP Module card dimensions: 00 mm wide, 0 mm long Module rear connector: SD way HD/SD way Z pack + /9 coax inserts Module rear panel dimensions: -A versions: 9 mm (. in.) wide Double-width: 0. mm (. in.) high Single-width: 0 mm (0.8 in.) high CE Performance Information Environment: Commercial and light industrial E immunity, controlled EMC E emissions Peak mains inrush current following a second mains interruption: A Power (each PSU) Input voltage range: 00 0V 0/0 Hz Input connector: IEC0 Fused T.AH Input current:.a Enclosure power consumption: 8.W maximum (±.V supplies) Outputs: +.V and -.V ±0% Fan supply V ±V 0.A typical Note that all modules have built-in power supply fuses. Mechanical Temperature range: 0 to 0 C ( to 0 F) operating, -0 to + C (- to F) storage. Cooling fan is fitted Humidity range: 0 to 8% (non condensing) Case type: RU rack mounting aluminum case Dimensions: 8 x 0 x. mm (9.0 x 8. x. in.) (WxDxH) Depth behind rack ears excluding space for leads: 0 mm (. in.) Weight empty:. kg (. lbs.) Weight including modules: 8. kg (8. lbs.) ORDERG IQHA-S-P Enclosure with Dual Redundant PSU & Ethernet/SNMP Compatible RollCall Gateway Card. module slots. Accessories IQHAPSU Single PSU as cold spare or upgrade to Dual PSU configuration. IQHA-S-GATEW Ethernet/SNMP compatible RollCall Gateway card for IQHA enclosures. Note: Although IQ modules are interchangeable between enclosures, their rear panels are enclosure specific. Code A or B order codes may be used when installing modules in the IQHB and current build IQHA enclosure. IQHA and older generation IQHA enclosures only support Code A type rears. GVB--08A-EN-DS WWW.GRASSVALLEY.COM Join the Conversation at GrassValleyLive on Facebook, Twitter, YouTube and Grass Valley - A Belden Brand on LinkedIn. www.grassvalley.com/blog Belden, Belden Sending All The Right Signals, the Belden logo, Grass Valley and the Grass Valley logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. Grass Valley products listed above are trademarks or registered trademarks of Belden Inc., GVBB Holdings S.A.R.L. or Grass Valley Canada. Belden Inc., GVBB Holdings S.A.R.L., Grass Valley Canada and other parties may also have trademark rights in other terms used herein. Copyright 08 Grass Valley Canada. All rights reserved. Specifications subject to change without notice.