Measurement procedure for application of white light scanner in the automotive sector

Similar documents
Monte Carlo method to machine tool uncertainty evaluation

ScienceDirect. The use of Optical Methods for Leak Testing Dampers

Form Metrology for AM. Primary Investigator: Petros Stavroulakis

TESTING THE CAPABILITIES OF THE THREE-SPHERES ALIGNMENT METHOD FOR LASER TRIANGULATION SENSORS

ScienceDirect. AACMM Performance Test: Influence of Human Factor and Geometric Features

ScienceDirect. Study of Virtual Features in the Performance of Coordinate Measuring Arms

THE USE OF OPTICAL METHODS FOR LEAK TESTING DAMPERS

Comparision of contact and contactless measuring methods for form evaluation

Available online at ScienceDirect. Energy Procedia 69 (2015 )

ISO INTERNATIONAL STANDARD

AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS

OUT OF MACHINE CALIBRATION TECHNIQUE FOR ANALOG PROBES

A Procedure for accuracy Investigation of Terrestrial Laser Scanners

Gregory Walsh, Ph.D. San Ramon, CA January 25, 2011

3D scanning verifies the precision of objects printed on 3D printers

Hexagon Metrology WLS qflash

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

EMRP JRP IND62 TIM: Use of on-board metrology systems for area-scanning on machine tools

Guideways X axis Precision-manufactured, anodized extruded profile made of light metal. On stabilized, welded steel supports

ScienceDirect. Evaluation of Measuring Capability of the Optical 3D Scanner

DATA SHEET DEA GLOBAL SILVER 09.XX XX.10

Traceable 3D X-Ray Measurements ZEISS METROTOM

X=2000 Z=2000 X=2000 Z=1600. E0/E150 in µm L/ L/ L/ L/ L/ L/400. R0 in µm

PRODUCT BROCHURE DEA MICRO-HITE. Handy and Cost-Effective CMM

Ch 22 Inspection Technologies

Axes 150 mm/s 150 mm/s. Y axis Z axis Vector 260 mm/s 260 mm/s. P in µm P in µm

Three-dimensional nondestructive evaluation of cylindrical objects (pipe) using an infrared camera coupled to a 3D scanner

REQUIREMENTS FOR THE CERTIFICATION OF PERSONNEL ENGAGED IN ULTRASONIC TESTING OF WELDS USING PHASED ARRAY TRANSDUCERS. PAUT Level 2 Multisector

PRODUCT BROCHURE TIGO SF. 3D coordinate measuring machine for the shop floor

PWO: Faster to Finished Sheet Metal Forming Tools with Optical Metrology

WiMo (286745) & WIMCAM (641489) Outer wing metrology & measurement campaigns

METROLOGY SOLUTIONS THE OPTICAL PORTABLE CMM FOR INDUSTRIAL APPLICATIONS

WHITE PAPER. Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials

CyberGage360 3D SCANNERS. One-Button Automation for 3D Scan Inspection.

DPA. 3D coordinate measurement with hand-held digital camera MEASURE THE ADVANTAGE. MoveInspect TECHNOLOGY

SURROUND 3-DIMENSIONAL SCANNER

Multi-sensor measuring technology. O-INSPECT The best of optical and contact measuring technology for true 3D measurements.

VISION MEASURING SYSTEMS

Glare Spread Function (GSF) - 12 Source Angle

Video Endoscopic Metrology for Pipeline Welding

QUALITY CONTROL OF PARTS AND ASSEMBLIES USING SOFTWARE GOM INSPECT BASED ON PORTABLE CMM DATA

R0 in µm THP in µm 18 C - 22 C

Complete 3D measurement solution

Laser scanning and CAD conversion accuracy correction of a highly curved engineering component using a precision tactile measuring system

Draft SPOTS Standard Part III (7)

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

Abstract. Introduction

ROMER ABSOLUTE ARM ADVANCED PORTABLE 3D MEASUREMENT PRODUCT BROCHURE

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION

Integrated three-dimensional reconstruction using reflectance fields

A COMPREHENSIVE SIMULATION SOFTWARE FOR TEACHING CAMERA CALIBRATION

CyberGage 360 3D SCANNERS. One-Button Automation for 3D Scan Inspection.

TESTING VISION CMMS AND THE INTERNATIONAL STANDARD, ISO

MODERN DIMENSIONAL MEASURING TECHNIQUES BASED ON OPTICAL PRINCIPLES

3D Machine Vision made easy

Refined Measurement of Digital Image Texture Loss Peter D. Burns Burns Digital Imaging Fairport, NY USA

Virtually Real: Terrestrial Laser Scanning

Evaluating Measurement Error of a 3D Movable Body Scanner for Calibration

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442

Increasing Productivity/Quality through Better Utilization of Dimensional Data

Internet Client Graphics Generation Using XML Formats

REPLICATING A CMM-BASED INSPECTION PROCESS. InnovMetric Software replicates a CMM-based inspection process using a 3D digitizer and PolyWorks

Compact 3D optical surface profiler

MobileScan3D. MobileScan3D PlugIn for Geomagic. By Steintek GmbH

ISO INTERNATIONAL STANDARD. Ophthalmic instruments Corneal topographers. Instruments ophtalmiques Topographes de la cornée

Model-Based Segmentation of Impression Marks

Precimar. PLM and CiM Universal Length Measuring Machines

Light Tec Scattering measurements guideline

A Rapid Automatic Image Registration Method Based on Improved SIFT

Automotive Testing: Optical 3D Metrology Improves Safety and Comfort

New Approach in Non- Contact 3D Free Form Scanning

Acoustic Field Comparison of High Intensity Focused Ultrasound by using Experimental Characterization and Finite Element Simulation

EXPLORER CLASSIC BRIDGE COORDINATE MEASURING MACHINE PRODUCT BROCHURE

Compact non-contact 3D surface profiler

IRC 1100 Kalibrierstrahler / Calibration Source

On the impact of probing form error on form measurement in Computed Tomography

A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES

On the basis of degree of freedom of the arm and the type of joints used, a robotic arm can have any of the following designs:

APPROACH TO ACCURATE PHOTOREALISTIC MODEL GENERATION FOR COMPLEX 3D OBJECTS

Increasing the accuracy with a rich sensor system for robotic laser osteotomy

EXPERIENCES WITH 3D REFERENCE BODIES FOR QUALITY ASSESMENT OF FREEFORM SURFACE MEASUREMENTS

Matrox Imaging White Paper

GET A WHOLE new measure OF things!

Design of three-dimensional photoelectric stylus micro-displacement measuring system

REACTOR PRESSURE VESSEL FLANGE SEALING SURFACES PROFILOMETRY SYSTEM

SIMULATION AND VISUALIZATION IN THE EDUCATION OF COHERENT OPTICS

An Engineering Application Selection Guideline for Reverse Engineering Systems: Laser System and Optical System

Starrett-Bytewise Measurement Systems Profile In-Line Pipe Diameter Measurement System Technical Proposal May 8, 2014

MULTIPLE-SENSOR INTEGRATION FOR EFFICIENT REVERSE ENGINEERING OF GEOMETRY

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

The basis for precision

ScienceDirect. Analogy between immune system and sensor replacement using mobile robots on wireless sensor networks

Starrett-Bytewise Measurement Systems Profile In-Line Pipe Diameter Measurement System Technical Proposal May 8, 2014

Surface Texture Measurement Fundamentals

LOCAL AND GLOBAL CALIBRATION OF COORDINATE MEASURING MACHINES

MACHINE VISION FOR SMARTPHONES. Essential machine vision camera requirements to fulfill the needs of our society

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

THE OPTICAL PORTABLE CMM FOR INDUSTRIAL APPLICATIONS

Available online at ScienceDirect. Procedia Engineering 161 (2016 ) Bohdan Stawiski a, *, Tomasz Kania a

ISO Ophthalmic instruments Corneal topographers. Instruments ophtalmiques Topographes de la cornée. Second edition

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Manufacturing00 (2017) 000 000 www.elsevier.com/locate/procedia Manufacturing Engineering Society International Conference 2017, MESIC 2017, 28-30 June 2017, Vigo (Pontevedra), Spain Measurement procedure for application of white light scanner in the automotive sector J. Tiscareño a, J. Santolaria a, J. A. Albajez a * (a) Departamento de Ingeniería de Diseño y Fabricación. Universidad de Zaragoza, C\ María de Luna 3, Zaragoza 50018, España. Abstract Advanced optical metrology systems are continuously being developed to cope with the challenges arising from large-scale, high-quality production, especially in the automotive sector. Therefore, these measuring devices are relatively new and they are ruled by very general standards. The main goal of this work is to develop a specific procedure for a white light fringe projection optical measurement equipment from a general measurement system analysis procedure used in the automotive sector (MSA-4 Reference Manual) considering the recent international regulations for the verification of this type of equipments: Technical Recommendation VDI/VDE 2634 and ISO 10360-8: 2013. Only the tests applicable to the equipment used to validate the proposed procedure, a 3D white light structured scanner SIDIO Pro from Nub3d, were analyzed. 2017 The Authors. Published by Elsevier B.V. Peer-review under responsibility of the scientific committee of the Manufacturing Engineering Society International Conference 2017. Keywords: White-light optical equiment; measurement procedure 1. Introduction The challenges arising from large-scale production and with high quality, the requirements of more advanced systems for the measurement of errors and the optical metrology systems, including those laser based, photography and white light fringe projection systems, are issues of great importance for industry nowadays. The scanning of * Corresponding author. Tel.: +34-976-76-1895. E-mail address: jalbajez@unizar.es 2351-9789 2017 The Authors. Published by Elsevier B.V. Peer-review under responsibility of the scientific committee of the Manufacturing Engineering Society International Conference 2017.

2 Author name / Procedia Manufacturing00 (2017) 000 000 three-dimensional objects has become a quality control procedure commonly used in industry, especially in the automotive sector, due to the high levels of precision and speed of capture needed. Being such relatively new measuring equipments, users sure face with very general standards, which leads to discrepancies among evaluations of equipment from different manufacturers, given that it is possible that different interpretations are presented when defining which tests to perform for a particular equipment. On the other hand, the combination of different measurement equipments has unclear specific procedures. For these reasons, the present paper will study one of the main documents related to the subject in the automotive sector, MSA-4 Reference Manual [1], and analyze possible correlations with other two much more specific documents: Technical Recommendation VDI/VDE 2634 [2] and ISO 10360-8:2013 [3], that could be applied to a 3D white light structured scanner SIDIO Pro from Nub3d. The main idea is to provide the automotive sector with a procedure that complies with the MSA-4 Reference manual and in turn the data obtained from the proposed tests can be used to comply with the international regulations after the data processing indicated in each of them. Although there are several published studies related to the research on the best way to evaluate this type of measurement instruments [4], we analyze the application of these standards and not their quality. The SIDIO Pro equipment consists of a projector located in the central part of the equipment and a camera that is located to one side of the projector in an extensible part. This system, like all equipments on the SIDIO line, is equipped with TRIPLE software [5]. This software is designed with a simple user interface, which includes the most important functions for data capture and sensor control. In addition, it is compatible with different point cloud management and inspection programs such as Polyworks or Geomagic Qualify. See Fig. 1. 2. Normative analysis Fig. 1. (a) Photography of SIDIO Pro equipment; (b) Camera calibration equipment; (c) Point cloud example. This paper analyzes the following three documents in order to find the possible correlation between them, considering as base the first one, for a specific equipment: MSA-4 Reference Manual Technical Recommendation VDI/VDE 2634 ISO 10360-8: 2013 The first one, MSA-4 Reference manual, was developed by the Measurement Systems Analysis Working Group (MSA), consisting of Chrysler Group LLC, Ford Motor Company and General Motors Corporation. Under the

Author name / Procedia Manufacturing 00 (2017) 000 000 3 auspices of the Automotive Industry Shareholder Group (AIAG). Its purpose is to evaluate the quality of a measurement system where readings of each part can be replicated. Other available international reference manuals are the ISO 22514-7 [6] and the VDA 5 [7]. The procedures explained in the manual are very general so they can be used as a reference for very different environments to any measuring instrument, although its main objective is to be used in the industrial world. The overall set of statistical procedures used for the above-mentioned evaluation is divided into four groups: Determination of stability Determination of bias Determination of linearity Determination of repeatability and reproducibility Each one of these groups is used to determine a specific characteristic that allows an evaluation of one aspect of the quality of the measurement system. It is important to mention that all procedures established by the MSA-4 Reference Manual are validated against the variability of the production process to be controlled, so that it is possible to ensure an adequate probability of detection of defective parts. The other two documents share and represent a very different and specific point of view based on the metrological characterization of some optical devices. The second one, technical recommendation VDI/VDE 2634, was developed by the technical committee of 3D measurement of the society of measurement and automatic control VDI/VDE and by the German association of photogrammetry and remote capture. Defines the parameters for the acceptance and re-verification tests of point-topoint measurements and surface measurements. For that purpose, the technical recommendation VDI/VDE 2634 was divided into the following three parts: Part 1. Point-to-point measurement systems. Part 2. Optical systems based on scanning area. Part 3. Multiple vision systems based on scanning area. In each of these parts, the concept "mode of operation" is defined as operation under certain external conditions and configuration. Such external adjustments and factors depend on the type of system being studied. In general some of the adjustments are the luminosity, measurement volume, type and number of sensors used. And some of the external factors are temperature, humidity, vibrations and dust. In our case, the procedures applicable to the measurement equipment, corresponding to the second and third parts will be performed. The second part takes into account a series of factors, digitizing errors, mechanical phase errors, pixel errors or coordinates, to proceed with the measurement. While the third part, in addition to the factors mentioned above, takes into account if the system is capable of transforming several captured images independently, in a common system of coordinates. The test error will be affected by two independent errors, firstly the error of the simple measurement in the volume of measurement, and secondly, the error due to the transformation of simple measures. And the last one, ISO 10360-8: 2013, is applicable to Cartesian MMC (Machines and Coordinate Measurement) with an image probing system of any type, operating in the discrete point probing mode. First, this standard establishes the operating conditions. Some environmental aspects are defined as well as operational conditions that influence the measurements at a time: Temperature Air humidity Cycles of ignition and heating of machine Cleaning procedures Qualification of the probing system before calibration

4 Author name / Procedia Manufacturing00 (2017) 000 000 Thermal stability of the probing system before calibration Lighting and environmental lighting system Location, type and number of thermal sensors Configuration of the probe by image and amplification Image Processing Filters and Algorithms This part of ISO 10360 specifies the acceptance tests for verification of the MMC when measuring lengths indicated by the manufacturer. Verification tests are also specified to allow the user to periodically check the operation of the MMC. The acceptance tests are executed according to the manufacturer's specifications and the verification tests according to those of the manufacturer and user, in our case, no restriction is imposed on the acceptance values, since the objective of this study is to analyze the standard, not the validity or not of the results of the measurements. Then in Table 1 we can see the summary of errors analyzed by VDI/VDE 2634 and ISO 10360-8: 2013 as well as the number of measurements required. Table 1. Summary errors analyzed. VDI/VDE 2634-2 VDI/VDE 2634-3 ISO 10360-8:2013 Spheres Errors evaluated Diameter error Form error Size error Form error Scatter error Size error Global size error Number of measurements 10 15 1 required Lengths Errors evaluated Space gap error Space gap error Distance error quality parameter E Length error Number of measurements 7 7 105 required Planes Errors evaluated Flatness error N/A Flatness error Number of measurements required 6 N/A 2 3. Proposed procedure The procedure proposed in this paper is based on Manual MSA.4, which is a general document, but considering the recent international regulations for optical equipment of white light projection. It is important to emphasize that the main idea is to provide the automotive sector with a procedure that complies with the MSA-4 Reference manual and in turn the data obtained from the proposed tests can be used to comply with the international regulations after the data processing indicated in each of them. The overall set of statistical procedures used in the MSA-4 Reference Manual is divided into four groups: Determination of stability: Control graphs Determination of bias: Independent sample method Determination of repeatability and reproducibility: ANOVA method Determination of linearity: Linearity graph

Author name / Procedia Manufacturing 00 (2017) 000 000 5 Each one of them determines a specific characteristic that allows to evaluate an aspect of the quality of the measurement system. In all of them, the suggested method [1] was performed and the three main types of errors that deal with international standards, spheres, planes and lengths were analyzed, with the reference objects and orientations specified therein [2-3]. In other words, the proposed procedure follows the data processing indicated in the manual [1] and in order to comply with international regulations, it follows the indicated parameters (reference objects and orientations) in international regulations [2-3] for obtain the data. Regarding the measurement error in spheres, the data will be related to the radius of the same. In the case of lengths errors will be referred to the distance between the centers of two spheres. And the one of planes is referred to the distance between the farthest point and the best adjusted plane of the cloud of points. Determination of stability In the three types of measurement errors analyzed, the corresponding reference object should be measured 12 times and the measurements should be represented in control charts. In the control chart X-bar (Averages), the 12 values are plotted. In the control chart R (Ranges), the 12 measurements will be divided into 4 subgroups and calculated the range of them so only 4 values are plotted. Determination of bias In the three types of measurement errors analyzed, the corresponding standard should be measured 10 times. Determination of repeatability and reproducibility The measurements made in the determination of the bias were used and afterwards repeated by another evaluator, obtaining the values of n=5 orientations, k=2 evaluators and r=2positions in the measurement area where it will be measured each orientation. Determination of linearity This test evaluates the difference in bias over the measuring range and that concept is only related with the length error measurement evaluated by ISO 10360-8:2013. For it, the reference object specified above was used and the ten measurements should be performed according to the orientations specified in the standard, plus three arbitrary ones. 4. Results According to the main idea, to provide the automotive sector with a procedure that complies with the MSA-4 Reference manual and in turn the data obtained from the proposed tests can be also used to comply with the international regulations after the data processing indicated in each of them, the results of this proposed procedure, based on MSA-4 Reference manual, will be presented below. It is important to remember that regarding the measurement error in spheres, data will be related to the radius. In the case of lengths, data will be referring to the distance between the centers of two spheres. And the one of planes is referred to the distance between the farthest point and the best adjusted plane of the cloud of points. Determination of stability According to MSA-4 Reference manual, in all three cases the measures are within the limits of control, therefore we can say that the measurement system is stable in this type of measures. See Fig. 2, 3 and 4. Fig. 2. Control Charts corresponding to spheres.

6 Author name / Procedia Manufacturing00 (2017) 000 000 Fig. 3. Control Charts corresponding to lengths. Fig. 4. Control Charts corresponding to planes. At the same time, when using the standards and orientations set out in the regulations, this data and point cloud capture can be used for the calculation of ball measurement error established in VDI/VDE 2634-2 and ISO 10360-8: 2013, length measurement error set in VDI/VDE 2634-2 and VDI/VDE 2634-3, distance error quality E parameter set in VDI/VDE 2634-3 and flatness measurement error set in VDI/VDE 2634-2 and ISO 10360-8: 2013. It should be taken into account that they must go through the data processing flow established in each document. Determination of bias For the evaluation of this parameter the same data as the determination of stability were used, ten of them. According to the MSA-4 manual, a bias value can be accepted if, when performing the verification calculation (contrast test of null bias hypothesis), the value zero is within the calculated range. As it is possible to appreciate in the test tables, only in the case of the spheres we can say that the presented bias is acceptable. See Table 2, 3 and 4. Table 2. Testing table for the determination of bias corresponding to spheres Testing -0.0044 < 0 < 0.0070 Table 3. Testing table for the determination of bias corresponding to lengths Testing 0.0856 < 0 < 0.1311 Table 4. Testing table for the determination of bias corresponding to planes Testing 0.0856 < 0 < 0.1311

Author name / Procedia Manufacturing 00 (2017) 000 000 7 Determination of repeatability and reproducibility For this parameter the same data are used as the determination of the bias and then the same measurements were repeated by another evaluator, obtaining the values of n=5 orientations, k=2 evaluators and r=2 spaces in the measurement area where each orientation was measured. And as indicated in the MSA-4 reference manual, it is possible to appreciate in the three graphs that the lines corresponding to the measurements of the two evaluators are relatively parallel, so we can conclude that the interaction is not significant. See Fig. 5, 6 and 7. Fig. 5. Repeatability and reproducibility chart corresponding to spheres. Fig. 6. Repeatability and reproducibility chart corresponding to lengths. Fig. 7. Repeatability and reproducibility chart corresponding to planes

8 Author name / Procedia Manufacturing00 (2017) 000 000 Determination of linearity As indicated in the MSA-4 reference manual, the adjusted graph is very similar to the "Bias 0" line, so we can conclude that the equipment complies with linearity in this type of measurements. See Fig. 8. Evaluating the linearity according to MSA-4 but considering the standards and orientations established in ISO 10360-8: 2013, it is also possible to use the same data for the calculation of the length error. 0,150 Linearity 0,100 0,050 0,000-0,050-0,100-0,150 1 2 3 4 5 6 7 8 9 10 Fig. 8. Linearity graph for lengths. 5. Conclusions In the results we could observe an example of the application of the proposed procedure based on the MSA-4 reference manual having also taken into account the parameters indicated in the international regulations (VDI/VDE 2634 and ISO 10360-8:2013) for the obtaining of the data. It may be concluded that it is possible to use the same data to comply the standards to a great extent. It is also possible to conclude that when applying the proposed procedure, the technical recommendation VDI/VDE 2634-2 is fully complied with. In the case of VDI/VDE 2634-3 is only necessary to carry out the additional measurements corresponding to the sphere error measurement. Conversely, when we have the data of the tests carried out according to the technical recommendation VDI/VDE 2634-2, it is necessary to include additional measures, three in the case of lengths and five for the planes, to evaluate stability and bias according to MSA-4. In the case of ISO 10360-8:2013, enough data are available to perform the data processing corresponding to the error related to spheres and planes. In turn, if two repetitions of the proposed procedure in the determination of linearity are made, sufficient data would be available to calculate the error related to lengths and thus fully comply with the ISO norm. Conversely, having the calibration report based on the ISO standard would only provide sufficient data to perform the linearity determination. Acknowledgements Appreciation to the Consejo Nacional de Ciencia y Tecnología (CONACYT) from the government of Mexico which sponsors the first author. References [1] Chrysler Group LLC, Ford Motor Company, General Motors Corporation, MSA-4 Reference Manual, fourth ed., 2010. [2] Verein Deutscher Ingenieure e. V. Technical recommendation VDI/VDE 2634, Düsseldorf, 2002. [3] International Organization for Standardization. ISO 10360-8:2013, Geneva, 2013. [4] T. Luhmann, K. Wendt, Int. Arch. Photogramm. Remote Sens. 33/5 (2000) 493-499. [5] NUB3D S.L., 2015, 3D White Light Scanner NUB3D, Available at.: http://www.nub3d.com/metrology-system/3d-scanners/ [6] International Organization for Standardization. ISO 22514-7:2012, Geneva, 2012. [7] Verband der Automobilindustrie e. V. VDA, Capability of measurement processes, Berlin, 5 (1) 2011.