New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

Similar documents
DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

NGBASE-T Cabling Requirements

Datasheet: DSX CableAnalyzer Series

ISO/IEC TR Guidance on 40GBASE-T T Cabling

How new testing standards affect you Singapore, Nov 2009

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

R&Mfreenet Advanced Cat 6A Shielded Connection Module

Network Connectivity. Copper LAN cables. Product catalogue 2010

LAN Standards, News & Trends Update 2017 June 15, 2017

Datasheet: DSX-5000 CableAnalyzer

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity

Cat.8 Shielded Field Termination Plug Description

Datasheet: DSX CableAnalyzer Series

Provided by

ISO/IEC 11801: (E)

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Datasheet: DSX CableAnalyzer Series

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Cat.8 Shielded Keystone Jack Description

Get ready to overachieve.

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS

History of Standards

CERTIFICATION PLUS SM

Certification for 10G copper cabling

Structured Cabling Technology and Market Assessment

Standards Update. by Paul Kish NORDX/CDT

The High Cost of a Low-Cost Cable Certification Tester

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

Datasheet: DSX CableAnalyzer Series

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

INTERNATIONAL STANDARD

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45

Recent Changes in the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP

40G BASE-T Cabling Infrastructure. Allan Nielsen Standards Manager

Introduction to Key Principles of Telecommunications Cabling

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

PANGEN SYSTEM WARRANTY. Warranty Guide

barpa Values Website & Social Network

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

ANSI/TIA-568-C Cat 6A Field Test Specifications

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

[0.057] 5.8 [0.23]

Application Note: Mode Conversion Testing Prevents Your Network from Hanging in the Balance

Testing and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing.

ANSI/TIA-568-C Cat 6 Field Test Specifications

AMP-TWIST* Modular Jack, UTP, Category 6A

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Common Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks

10GBASE-T and. Copper Cabling Choices

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

RELEVANCE OF C5E AND C6 PLATFORMS IN TODAY S MARKET. Krzysztof Ojdana, Product Manager - EE WHITE PAPER. Molex Premise Networks

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Complimentary Reference Material

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

AS/NZS 3080:2003 AS/NZS

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Which networks do we need in the 2020s`? Selection criteria for structured copper cabling. Zoran Borcic Product Manager Copper Datacom

Copper Cabling Standards

TIA TR-42 Liaison to IEEE

10G Ethernet Over Structured Copper Cabling

Independent Testing - For End User Confidence

Meeting updated ISO/IEC Your professional partner of structured cabling system

November 2010 IEEE 802.3

Test Report modcon - PS88A6M

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

The Impact of Internet of Things on Cable Certification

ProCurve Mini-GBICs. Used with the following

LANmark-6 10G LANmark-6 A

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

Series. WireXpert Key Features. Easy to use and Ruggedized design. Fast and simple for highest productivity

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

9/27/04 cci Cablecom Inc. 1

The Impact of Internet of Things (IoT) on Cable Certification

Datasheet: DSX-5000 CableAnalyzer

Cabling Infrastructure

The module for the highest standards, guarantees the best performance in the 10 Gigabit Ethernet cabling.

AMP-TWIST* 6S Series SL Jack

[0.057] 5.8 [0.23]

Cabling Life Cycles and the Laws of Networking Communications

Performance specification for the Fluke DSP Fluke Corporation

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Chapter 4: Network Access. Introduction to Networks v5.1

Physical Layer Part 3

Connecting Trains: The Promise of On-board Ethernet Networks How to use Ethernet to increase on-board network functionality and lower costs

Transcription:

New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

Three Realities of Networking #1 - Networks Never Go Slower Plan for higher speeds, increased throughput, reduced latencies #2 - Networks Never Get Smaller Plan for more users, more traffic, more capacity, more complexity #3 - Networks Never Stay the Same Plan for flexibility, reconfiguration, manageability

Standards Changes Constant demand for faster data transfer rates! We want more data and we want it NOW!

What is developing ANSI/TIA-568.3D Optical Cabling and Components Standard. Defines what fiber optic cabling looks like in a premise or data centre Provides methods for testing the installed cabling. Here is where the trap is set. The link budgets we use for testing have changed. Plus the methods we use have been re-enforced, NO PATCH CORDS for testing! 7.3.4 Use of test cords Both ANSI/TIA-526-7 and ANSI/TIA-526-14 recommend the use of reference-grade terminations on test cords to reduce uncertainty and improve the reproducibility of measurements. Reference-grade terminations result in lower loss than standard-grade terminations. Table 11 provides the Test Cord Loss Allowance for two different termination combinations. Table 11 - Test cord loss allowance Mated termination combination Multimode (db/connection) Single-mode (db/connection) Reference-grade to standard-grade 0.3 1 0.5 2 Standard-grade to standard-grade 0.75 0.75 Note 1 This value is taken from ANSI/TIA-526-14, Table F.1. Note 2 This value is taken from ANSI/TIA-526-7, Table G.1.

ANSI/TIA-568.3-D Loss Calculations In the context of testing correctly, this guidance changes the way we think of links when calculating Pass / Fail limits. Link Attenuation Allowance (db) = Cabled Fiber Attenuation Allowance (db) + Connections Attenuation Allowance (db) + Fiber Splices Attenuation Allowance (db) + Test Cord Attenuation Allowance (db) Where; Cabled Fiber Attenuation Allowance (db) = Maximum Cabled Fiber Attenuation Coefficient (db/km) Length(km) Connections Attenuation Allowance (db) = Number of Connections within the link Connection Loss Allowance (db/connection) Fiber Splices Attenuation Allowance (db) = Number of Splices Fiber Splice Loss Allowance (db/splice) Test Cord Attenuation Allowance for one-cord reference method = 2 Test Cord Loss Allowance Test Cord Attenuation Allowance for two-cord reference method = 1 Test Cord Loss Allowance Test Cord Attenuation Allowance for three-cord reference method = 0 Test Cord Loss Allowance Note: The number of connections within the link excludes the connections on the ends of the link to the test cords that are accounted for subsequently as Test Cord Attenuation Allowance.

The new Category 8 application IEEE 802.3bq 25G/40GBASE-T published 8 September 2016 Defines minimum transmission characteristics for the application on a twisted pair channel ANSI/TIA-568-C.2-1 published 30 June 2016 Defines Category 8 Channels and Permanent Links Includes Resistance Unbalance, TCL, ELTCTL ANSI/TIA-1152-A published 10 November 2016 Defines tester measurement and accuracy requirements for Category 8 ISO/IEC Standards expected in 2017 ISO/IEC 11801-99-1 Class I/II Channels and Permanent Links IEC 61935-1 Ed5.0 tester measurement and accuracy requirements

Why 25G/40G on Twisted Pair? Lower power and lower costs Can be built into switch and server motherboards No SFP Transceiver required as with fiber Lower cost and more flexible than TwinAx Direct Attach cables Can Auto-Negotiate at different rates Expected to be a data center application only 24m Permanent Link, 2 * 3m Patch cords max to create the channel of 30m Top of Rack and End of Row Switch data center architectures Category 6A and 10GBASE-T followed similar path

Three types of Category 8 to deal with! The ANSI/TIA standardization body specifies Category 8 cabling components. They are backwards-compatible with the RJ45 jacks of Categories 6A, 6 and 5e according to ANSI/TIA-568-C.2. ISO/IEC specify two valid variants: Categories 8.1 and 8.2. ISO/IEC Category 8.1 components are used to build Class I links. They are backward-compatible with the RJ45 connector interface for Categories 6A, 6 and 5e specified in ISO/IEC 11801. Minimum cable type is U/FTP or F/UTP Foil sheaths Drain wire 8

Three types of Category 8 to deal with! The ANSI/TIA standardization body specifies Category 8 cabling components. They are backwards-compatible with the RJ45 jacks of Categories 6A, 6 and 5e according to ANSI/TIA-568-C.2. ISO/IEC specify two valid variants: Categories 8.1 and 8.2. ISO/IEC Category 8.2 components are used to build Class II links. The standard defines different connector interfaces that are not compatible with one another. Category 8.2 components are backward-compatible with Category 7A and 7 components with the appropriate plug. Category 8.2 connector interfaces are not backward-compatible with the RJ45 jacks of existing cabling. Minimum cable type is F/FTP or S/FTP. Outer foil sheath Twisted pairs Inner foil sheaths Braid 9

Category 8.1 The manufacturers of active equipment have asked for an RJ45-compatible plug configuration, and therefore for the international use of Category 8.1. This solution is backward-compatible with the billions of RJ45 connections installed worldwide. This is a key issue! Active equipment manufacturers will be using RJ 45 jacks within their products. Connection is either via a traditional channel model or via direct connect. To field test you need Cat 8 Channel Adapters with RJ45 jacks and Permanent Link leads. 10

Category 8.2 In Europe, many of the installed links are terminated in other connectors, like the Siemon TERA and Nexans GG45. To maintain compatibility with these systems, manufacturers created Cat 8 components using these connector types. Typically Cat 8.2 components provide more headroom than Cat 8.1 components. TIA and ISO/IEC are currently discussing harmonizing their specifications on both ends, as well as including Category 8.2 components in the TIA standard. 11

To summarise the Cat 8 types We will need to be able to field test three types of Category 8 solution. All have a maximum frequency of 2GHz All require the need for Channel Testing All require the need for Permanent Link Testing Component Category Link Class Max. Frequency Responsible Standards Body Usage 25GBASE-T 40GBASE-T Compatible with RJ 45 Cat 8 Cat 8 Link 2GHz ANSI/TIA North America Yes Yes Yes Cat 8.1 Class I 2GHz ISO/IEC International Yes Yes Yes Cat 8.2 Class II 2GHz ISO/IEC International Yes Yes No 12

Field testing Cat 8 solutions ANSI/TIA-1152-A published last November and supports the testing of installed Category 8 solutions plus all the preceding categories of cabling, 5e, 6 & 6A. Defines the levels of tester. Level IIe accuracy covers Category 5e Level III accuracy covers Category 6 Level IIIe accuracy covers Category 6A Level 2G accuracy covers Category 8 ISO/IEC will publish 61935-1 Ed 5 Adds Class I and Class II link testing ISO will have a Level VI accuracy for Class I & II testers.

ANSI/TIA field test requirements With the new ANSI/TIA-1152-A we also get some changes in field testing. We carry out all the usual parametric tests but now up to 2GHz, if testing Cat 8. New requirement for wiremap test; when testing Cat 8 installations, must test the shield continuity along the path of the cabling. Prevents the field tester being fooled by ground paths via racking and the earth connections. Optional tests added to support the emerging IEEE 802.3bt PoE++ standard. Channel dc loop resistance is to be below 25Ω Current imbalance between pairs is to be minimized. This is achieved with Resistance Unbalance measurements within the pair and between pairs. ANSI/TIA-568-C.2 & C.2-1 Cabling System Requirements Copper Certification ANSI/TIA-1152-A Field Test Requirements Wire Map * Length Propagation Delay Delay Skew dc Loop Resistance ** Optional Resistance Unbalance ** Optional Insertion Loss NEXT, PS NEXT Return Loss ACR-F, PS ACR-F TCL, ELTCTL PS ANEXT, PS AACR-F * For Level 2G testers screen continuity is tested along the path of the cabling. ** Proposed Measurement requirement to support IEEE 802.3bt DTE Power over MDI

RJ45 connection RJ45 connection Shield Continuity (RF) An ordinary continuity test would show this as connected. Shield Shield

Critical requirements for testing For field testing we have two test models to work with, Channel and Permanent Link. The installer usually installs and tests a Permanent Link. However, the application requires proper Channel performance, which includes PL and the patch cords. To test a Permanent Link you need reference grade RJ45 Plugs To test a Channel you need a correctly performing RJ45 jack that is perfectly centred.

Creating the field test interfaces ANSI/TIA-1183-1 gave us the test methodology to enable us to produce components and verify their performance. The Cat 8 reference plug came first. With a reference plug you can then produce a Permanent Link interface. With a reference plug you can then make test jacks. With test jacks, you can make Channel interfaces for testing.

To summarize International structured cabling standards will continue to evolve and change These new standards bring to us more bandwidth and higher speeds to meet our ever growing data demands. Your testing solution must also evolve to meet the challenges of these new cabling categories, both copper and fiber, that are being introduced.