Universal Safety Photo Eye UL MONITORED DEVICE

Similar documents
IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

OPERATING INSTRUCTIONS

Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

General-Purpose Photoelectric Sensor

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET

Compact Coded Magnetic Safety Interlock Switch and Control Units

onlinecomponents.com

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

Special-Purpose Photoelectric Sensors

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

VSS Nederland Video Systems

Safety switches for hinged doors

Safety switches with separate actuator

Series 28 Universal Sensors

MLS7A Series. Photoelectric Sensors. Heavy-Duty Retro-Reflective Sensors. Photoelectric MLS7A Series Heavy Duty PEPPERL+FUCHS 529

Series 3700 Screw Terminal Assemblies Installation Instructions

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

8000 Series: Installation Supplement R2-1-12

MLV41 Series Miniature Sensors

ReFlx. ReFlx 100 Collision Avoidance System Instruction Manual Page 1 6/30/99

THE ARIA. LED AREA LIGHT. eran industrial. ARL SERIES

Safety switches with manual mechanical delay and separate actuator

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Nokeval. FD100 series. User Manual

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Photoelectric Sensor

Magnetically Actuated Safety Interlock Switches

INSTALLATION INSTRUCTIONS

Rotork Fairchild PAX1 Linear Actuator User s Manual

25 m 5 m 1 m. Part Number Mounting bracket. E39-LU1 Mounting bracket for E39-R1 reflector

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

F3ET Lightcurtain in robust aluminium housing

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

MHP PHOTOELECTRIC. Sensors and Switches NOTICE GENERAL INFORMATION

Safety switches with separate actuator

BMX DDM Mixed Relay Input/Output module

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

ASI Systems ML5740A Series

ASI Systems ML5720A Series

T4HD: Installation Supplement R8.1.13

ZC Series Zone Monitoring Controllers

Level-Lance Model 5400A

Versatile Safety Interlock Switch with Guard Door Locking

SELECTRONIX, INC. SUPERSTEP SERIES 4000 SEQUENCING STEP CONTROLLERS WOODINVILLE, WA INSTALLATION & OPERATING ADDENDUM LOAD LIMIT INPUT CONFIGURATIONS

Differential Liquid/Gas Pressure Transmitter

Installation, Operation and Maintenance Manual

Magnetically Actuated Safety Interlock Switches

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

MANUAL (TRANSLATION) RAY-LG X5XX

onlinecomponents.com

EX12LED Infrared LED Illuminator

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

MULTIBAND Dual Radio V4

Legacy Sensor Products

Conveyor Belt Alignment Switches from IDEM

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

AEGIS UFLED INSTALLATION INSTRUCTIONS

Description. Features. Ultrasonic Sensors 873P Analog or Discrete Output INTRODUCTION. 873P Analog Output18 mm. 873P Discrete Output30 mm

PRECISION LED HIGH MAST LIGHTING

Legacy Sensor Products

3RG7 Opto-BERO Photoelectric Proximity Switches

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

InView Communication Modules

ML20 Series Long-Range Miniature Sensors

InView Marquee Message Display

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

SMARTSCAN INFORMATION

DC Outdoor Power Supply/Chargers

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

onlinecomponents.com

AD-7830 Servo Amplifier

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Instruction Manual: IM E

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

ML17 Series Tru-Vue TM Sensors

Operating instructions. Speed monitor D / / 2014

Suitable for detecting transparent films or transparent bottles

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

ML17 Series Tru-Vue TM Sensors

Color Mark Photoelectric Sensor E3S-VS

User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters

PANELITE ENCLOSURE LIGHTS OVERVIEW

Photoelectric Sensors E3F2

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Features. Sensing range 50 mm mm... Type of light. Light source 3) Wave length. Adjustment 2) PL80A.

SLIMBAT2 wireless photocell MANUAL

Transcription:

IRB-MON Universal Safety Photo Eye UL325-2016 MONITORED DEVICE Operating Instructions

CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death! 1. Read and follow all operation instructions. 2. Always follow gate operator manufacturer installation instructions regarding installation of Type B1 sensor to the operator. 3. Disable the gate so it is unable to move GENERAL DESCRIPTION The IRB-MON is a thru-beam photo eye and is an external entrapment protection device type B1, non-contact sensor for use with automatic gates and doors. The light beam is near infrared and pulses at a rate of 300/second (300Hz). The IRB-MON provides a signal to the gate or door operator that the beam is not obstructed. The operating range is up to 115ft. The IRB-MON operates over a wide range of 6-35VDC and 12-24VAC. A green alignment indicator on the receiver provides status information at a glance, making set-up and alignment easy. The IRB-MON includes three selectable operating configurations providing compatibility with most operators that accommodate monitored external entrapment protection devices per UL325-2010. Refer to operator installation instructions for proper configuration selection: CONFIGURATION 0 - NON-MONITORED and MONITORED Intended for use with operators that require simple relay contact activation to indicate beam obstruction. CONFIGURATION 1 MONITORED, HEARTBEAT 300Hz / 0Hz Intended for use with operators designed to accept a heartbeat form of monitoring, 300Hz when aligned, no obstruction, 0Hz when beam is obstructed. CONFIGURATION 2 MONITORED, HEARTBEAT 300Hz / 2Hz / 0Hz Intended for use with operators designed to accept a heartbeat form of monitoring, 300Hz when aligned, no obstruction, 2Hz when beam is obstructed, and 0Hz for a failure. IRB-MON Operating Instructions 2

Configuration settings - Remove power when changing Configuration settings. SW4 SW3 SW2 SW1 FUNCTION X X OFF OFF Configuration 0 - relay operation, no frequency output X X OFF ON Configuration 1 - heartbeat output, 300Hz, 0Hz, no relay activation X X ON OFF Configuration 2 - heartbeat output, 300Hz, 2Hz, no relay activation ON X X X Dark on - N.O. contact closed when beam obstructed OFF X X X Light on N.O. contact closed when beam is not obstructed Green status indicator IRB-MON-T (transmitter) ON Power IRB-MON-R (receiver) Flashing Blocked beam or not aligned IRB-MON-R (receiver) ON Aligned SPECIFICATIONS Operating range up to 115 ft. (35m) Detection angle 24 o Sensitivity adjustment potentiometer Power indicator Green LED Detect indicator Green LED (flashing) Mode selection switch 3 modes, relay output, pulsed (3 frequency), pulsed (2 frequency) Relay output operation Light on/dark on selection Relay output Form C contacts (NO, COM, NC) Power protection Thermal fuse Transmitter power cycle >300mS (for use in Configuration 0 Monitored) Power Supply 6 35 VDC, 12...24VAC (Configuration 0 RELAY only) Current (Config. 1 and 2) 15mA (12VDC, includes TX and RX wired in parallel) Current (Config. 0) 60mA (relay activated) Operating temperature -40 F 170 F (-40 77 C) Environmental NEMA 4X Dimensions (L x W x H) 2.3 (57mm) x 2.6 (65mm) x 3.7 (94mm) Weight TX - 0.35 lbs (159 g), RX 0.35 lbs (159 g) Connections TX-2 terminal, RX-5 terminal IRB-MON Operating Instructions 3

INSTALLATION Install the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. DO NOT USE 12-24VAC IN PULSE CONFIGURATIONS. 1. Disconnect the IRB-MON from power before installing or servicing the device. 2. Always follow the instructions of the gate operator manufacturer regarding installation of type B1 sensors on the gate operator. The instructions of the gate operator manufacturer always supersede any instructions given in this or any other instructions by EMX Industries Inc. 3. Connect the IRB-MON power supply per requirements indicated in the specification table. 4. When using the relay outputs, do not exceed the voltage/current ratings indicated in the specification table. 5. Connect power to the terminals on the transmitter marked TX, polarity is not required. Refer to the CONFIGURATION DIAGRAMS for power wiring. 6. Connect power to terminals marked POWER INPUT on the receiver, marked RX polarity is not required. Refer to the CONFIGURATION DIAGRAMS for power wiring. 7. For CONFIGURATION 0 ONLY. Operators that require normally closed contact for entrapment protection, connect terminal NC and COM to the designated terminals in the gate operator. Operators that require normally open contact for entrapment protection, connect terminals COM and NO to the designated terminals in the gate operator. 8. Install the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 9. The IRB-MON is housed in a NEMA 4X enclosure. To insure the integrity of the enclosure make sure the covers are attached and closed tight using all four plastic screws provided. The wiring to the enclosure must enter via UL Listed watertight fitting such as a strain relief or watertight conduit connector. 10. The IRB-MON must be powered by Class 2 circuits only, wiring must be segregated from other circuits or insulation must be provided that is suitable for the highest voltage for those circuits. IRB-MON Operating Instructions 4

VERIFY INSTALLATION AND OPERATION Verify proper operation of the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 1. Verify that the IRB-MON transmitter and receiver in line of sight and apply power. 2. Place an obstruction (ex. hand) between the IRB-MON transmitter and receiver. The green LED on the receiver is flashing. Check the operator control board that the safety input is actuated. 3. Remove the obstruction and green LED will be on. 4. If the IRB-MON does not respond to the obstruction, lower the sensitivity by adjusting the SENSITIVITY pot counter-clockwise. 5. If the IRB-MON indicates an obstruction when there is no obstruction, increase the sensitivity by adjusting the SENSITIVITY pot clockwise. 6. Follow gate/door manufacturer s installation instructions and safety checks to verify that the IRB-MON is operating properly. TROUBLESHOOTING GUIDE Symptom Possible cause Solution Does not detect obstruction of Sensitivity too high Adjust SENSITIVITY pot beam counter-clockwise Green LED flashes continuously (indicating an obstruction when an obstruction is not present) Receiver activates but does not transmit signal to operator Signal is reflecting off another surface Sensitivity too low Transmitter does not have power Receiver does not see transmitter Faulty connection between receiver and operator control input Check area for highly reflective surfaces Adjust SENSITIVITY pot clockwise Check power source for transmitter Make sure transmitter and receiver have line of sight alignment Verify all wires and terminal connections IRB-MON Operating Instructions 5

ORDERING INFORMATION IRB-MON Infrared photocell includes transmitter and receiver IRB-HD-SET Protective hood, aluminum, gold anodized IRB-SD-SET Protective hood, steel, gray powder-coat IRB-BR Mounting bracket, L shape IRB-SP Strain relief, water-tight IRB-S Nylon screws, set of 4 IRB-MON Operating Instructions 6

IRB-MON Operating Instructions 7

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America http://www.emxinc.com Technical Support: (216) 834-0761 technical@emxinc.com Sales: (216) 518-9888 Fax (216) 518-9884 salessupport@emxinc.com 3.3.2015 IRB-MON Operating Instructions 8