SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Similar documents
SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

INSTRUCTION MANUAL. SDS511 CS I/O Dual Port Adaptor 4/02. Copyright (c) 2002 Campbell Scientific, Inc.

INSTRUCTION MANUAL. SC929 RS232 Interface 9/96. Copyright (c) 1996 Campbell Scientific, Inc.

INSTRUCTION MANUAL. SC532 9-Pin Peripheral to RS232 Interface. Revision: 8/92. Copyright (c) Campbell Scientific, Inc.

INSTRUCTION MANUAL. SC932A 9-Pin to RS-232-DCE Interface. Revision: 2/04. Copyright (c) Campbell Scientific, Inc.

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

RAVEN II DIGITAL CELLULAR MODEM INSTRUCTION MANUAL

CD100 Mountable Display with Keypad 11/11

PS100 and CH100 Power Supply and Charging Regulators, A100 Null Modem Adapter, and A105 Additional 12 V Terminals Adapter

SC532 9-Pin Peripheral to RS232 Interface

Redwing105 AirLink CDMA Modem C3111 Revision: 7/06

INSTRUCTION MANUAL. MD9 Multidrop Interface. Revision: 5/03. Copyright (c) Campbell Scientific, Inc.

RTDM RUN-TIME VERSION REAL TIME DATA MONITOR INSTRUCTION MANUAL

AEXX-349 SERIES REMOTE DISPLAYS

SC32A Optically Isolated RS232 Interface

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

AnalogBridge Analog transmission system

Proliphix EPA-60 Installation Guide

RTD SAMPLER OPERATOR S MANUAL

Rackmount Keyboard Installation Instructions. Revision A A-0000

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Getting Started Guide. Complimentary 10/2018. Copyright 2018 Campbell Scientific

S82S (3/7.5-W Models)

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

HVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:

GARNET. SEELEVEL I TM Tank Indicator INSTRUMENTS LTD. Model 707 Owner's Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: Max Signal

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

Ashly WR-5 Remote Control

WR-5e Remote Control

SERVICE MANUAL MODEL SSW-520-F

INSTRUCTION MANUAL L Sampler Control Cable for use with Isco and Sigma Autosamplers Revision: 3/14

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Westell. Breaker Panel Technical Practice NPDRP1114

Breaker Panel Technical Practice NPDRP1114

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

PCONNECT FOR THE PALM HANDHELD SOFTWARE SUPPORT FOR CAMPBELL SCIENTIFIC DATALOGGERS VERSION 2.1 INSTRUCTION MANUAL

Global Water Instrumentation, Inc.

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

EverPump Wireless Pump control system

INSTRUCTION MANUAL. RWIS Stations 3/05. Copyright (c) 2005 Campbell Scientific, Inc.

PCONNECTCE FOR POCKET PC HANDHELD SOFTWARE SUPPORT FOR CAMPBELL SCIENTIFIC DATALOGGERS VERSION 1.1 INSTRUCTION MANUAL

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

AE21 SERIES DISPLAY CONTROL TERMINAL

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

MAXIMA + Series ROTARY LEVEL CONTROL

Sensoray Model 627 CompactPCI to PCI Adapter

PCM-7140 Pulsed Current Source Operation Manual

SERVICE MANUAL MODEL SSW-321-X

User's Guide. Phase Sequence and Motor Rotation Tester Model

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

232iLM Keypad Installation and Programming Instructions

Connecting Sockets, Mounting Brackets, DIN Rails

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

American Power Design, Inc.

DC425 NEMA 4X Analog Output Transducers

FA-2448 SIX POSITION Filter Wheel

SERVICE MANUAL MODEL SSW-521-D2-ADA

SC-IRDA Infra-red Communications Interface

User's Guide. Extech AM A AC Analog Clamp Meter

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

SERVICE MANUAL MODEL SSP-350-X

PGR-3200 MANUAL INSULATION MONITOR

PIM-Mini Pulsed Current Source Operation Manual

High Speed Remote I/O Module

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

Tempco Instruction Manual

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CSM_PYF S/P2RF- -S_DS_E_2_5

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

User s Guide. POWERVAR Single Phase Power Conditioners

IE-MediaChassis/1. Operation Manual

RAYMAPB. Power Supply and Terminal Box for Marathon MM/MR/FA/FR Sensors. Manual Addendum. Rev. A 06/

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

ClearCube Enclosure Installation Instructions

icp installation guide

An ISO-9001 Certified Company

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

WS115 BREAKOUT ADAPTER USER MANUAL

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

MBPS-100R, MBPS-200R, MBHPS-100D, MBHPS-200D, MBLPS-100D, MBLPS-200D RACK MOUNT AND DIN RAIL MOUNT POWER SUPPLIES FOR FlameWorx MODULES

VCMDM MODEM INSTALLATION INSTRUCTIONS

V-9939B MICROPHONE ADAPTER

BTU 4 & Sensors. Installation and Operation Manual

Transcription:

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 3/03 COPYRIGHT (c) 1995-2003 CAMPBELL SCIENTIFIC, INC.

This is a blank page.

Warranty and Assistance The SVP48 SURGE VOLTAGE PROTECTOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages. Products may not be returned without prior authorization. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is: CAMPBELL SCIENTIFIC, INC. RMA# 815 West 1800 North Logan, Utah 84321-1784 CAMPBELL SCIENTIFIC, INC. does not accept collect calls. Non-warranty products returned for repair should be accompanied by a purchase order to cover the repair. 815 W. 1800 N. Logan, UT 84321-1784 USA Phone (435) 753-2342 FAX (435) 750-9540 www.campbellsci.com Campbell Scientific Canada Corp. 11564-149th Street Edmonton, Alberta T5M 1W7 CANADA Phone (780) 454-2505 FAX (780) 454-2655 Campbell Scientific Ltd. Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX, U.K. Phone +44 (0) 1509 601141 FAX +44 (0) 1509 601091

This is a blank page.

SVP48 Surge Voltage Protector 1. Overview The SVP48 provides transient protection for up to 22 conductors. Typical usage is to place the SVP48 in line between sensors and a Campbell Scientific datalogger to supplement the datalogger s built in surge protection. The SVP48 is designed to mount on Campbell Scientific's standard enclosure back plates with 1 inch centered, pre-punched square accessory mounting holes. The SVP48 consists of one or more surge protectors mounted on a DIN rail bracket. A single end plate is used to cover the last surge protector. 1.1 Physical Dimensions Length: 6.6 inches Width: Height: 2.6 inches 2.72 inches The two mounting holes in the DIN rail are spaced 6 inches apart center to center. 1.2 Specifications Surge protection is provided by gas filled arrestors that trigger at 110 VAC or 156 VDC. Each surge protector protects one conductor and provides a terminal for shield wires. 1

SVP48 Surge Voltage Protector 12 Surge Protectors Mounting Screw Surge Protector End Plate Nylon Grommet SVP48#1 (transient) DIN Rail 14 AWG Ground Wire FIGURE 1. SVP48 with Twelve Surge Suppressors 2. Installation 2.1 Mounting the SVP48 Prepare the SVP48 by mounting up to 22 surge protector plates onto the DIN rail as shown in Figure 1. Place the cover plate on the side of the last surge protector. Tighten the clamp screws (yellow/green terminal) on all but one surge protector. Prepare the enclosure mounting plate to accept the SVP48 by inserting the two square nylon grommets provided into two of the square mounting plate holes, six inches apart, but on the same row or column of holes. Mount the SVP48 to the enclosure mounting plate, centering the mounting holes over the nylon grommets and securing the DIN rail with the two screws provided. 2.2 Ground Connections The SVP48 is provided with a green 14 AWG ground wire for connection to the grounding chuck in the ENC 12/14 and ENC 16/18 enclosures. Remove the 2

SVP48 Surge Voltage Protector top nut on the ground chuck and place the ring end of the ground wire on the chuck. Replace the top nut. Insert the tinned end into the open yellow/green clamp terminal, then tighten the terminal. Ground the enclosure to earth with 14 AWG or larger wire. 2.3 Attaching Sensors to the SVP48 To provide complete protection for the datalogger, all leads must pass through the SVP48. All shield wires terminate in one or more of the yellow/green clamp terminals. To connect signal or excitation leads, insert the bare end of one lead into the terminal on either side of the surge protector. Run a short length of wire from the other side to the appropriate datalogger terminal. This short length of wire should be of the same gage and insulation type as the sensor leads provided by the manufacturer. Do not use wire with PVC insulation. 3. Maintenance 3.1 Replacement Considerations When an electrical surge occurs, the surge protectors involved may need to be replaced. Incorrect measurements will indicate that replacement is necessary. With an ohmmeter, confirm that an individual protector needs replacing by measuring the resistance between a top terminal and the yellow/green terminal. An open circuit or infinite resistance indicates that the surge protector is okay. Any other resistance reading indicates that it needs replacing. 3.2 Parts List Order the SVP48 using "SVP48-X", where X is the number of surge protectors desired (up to 22 per rail). Use the following part numbers for individual replacement items only. 8206 Surge Protector 8207 Surge Protector End Plate 8208 DIN Rail 6044 Nylon Grommet 505 Mounting Screws 5725 14 AWG Ground Wire 3

SVP48 Surge Voltage Protector This is a blank page. 4