RADIOMETER PHOTOMETER NDTM-10 INSTRUCTION MANUAL

Similar documents
RADIOMETER PHOTOMETER L-420 INSTRUCTION MANUAL

OPERATING MANUAL DATA LOGGING LIGHT METERS LXP-2, LXP-10B, LXP-10A

Digital UVC Light Meter

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

ENGLISH. User manual

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

SL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth.

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Heavy Duty Datalogging Light Meter

CONTENTS SECTION 1 SECTION 7 LIST OF AVAILABLE SPECIES

Manual Colour Meter PCE-CSM 5

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

INSTRUCTION MANUAL. Models: H100 Light Meter

Always there to help you. Register your product and get support at CRD150. Question? Contact Philips.

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

UV LIGHT METER UVC-254

i-reader User manual

IMPORTANT SAFETY INSTRUCTIONS

ENVIRONMENTAL PROTECTION

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

IMPORTANT SAFETY INSTRUCTIONS Do not use the product before you have studied the Safety instructions and the User Manual.

ENVIRONMENTAL PROTECTION

INSPECTION TOOL. Wireless Inspection Camera with Recordable Monitor. EU Environmental Protection. Model: 8802AL, 8803AL. Model: 8802AL, 8803AL

Druck DPI 620 advanced modular calibrator

ENGLISH. User manual.

LM-100 LM-120 Light Meters Users Manual

Always there to help you. Register your product and get support at SHL3850NC. Question? Contact Philips.

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

User manual BT7900. Register your product and get support at

Always there to help you Register your product and get support at SHL3855NC. Question? Contact Philips.

LA 90L / LA 180L. Operating instructions

User Manual. Cobia Flex R/F. English - v2014.3a

User Manual GBS-1269BT. Body Scale 4.0. version:1.0. Distributed by: Informed Clinical Sciences Corporation 1 Joy Street, Boston, USA MA 02108

VersaProbe Pro TM. Operating Instruction. 1. Description Technical Data Instructions for use 4

BLUETOOTH SPEAKER BLUEBEAT GSB 110

MicroCure And MicroCure Plus Instruction Manual

testo 175 Data loggers Instruction manual

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

Instruction Manual Extreme Temperature (XT) Data Logger

LDM M LASER DISTANCE MEASURER

AC/DC Current Probe Model SL201

AC/DC Current Probe Model SL206 USER MANUAL

Ball Probe Moisture Meter With Bluetooth

Manual Light Meter PCE -174

Operating Instructions

Prestigio P371 Users manual

HX1 Bluetooth Stereo Headset

EASY USE REMOTE CONTROL

User Manual. Cobia Flex R/F English - v2016.5a

Coating Thickness Tester

Always there to help you. Register your product and get support at SHB5950. Question? Contact Philips.

SHUTTERBOSS VERSION II USER MANUAL

Network Camera. Quick Guide DC-B1203X. Powered by

Digital Sound Level Meter with USB Model:

EXCLUSIVELY FROM. User guide DAB211PT. Portable DAB radio

Model S471 Portable Optometer

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

1GB/2GB/4GB MP3 Player. Instruction Manual L1GMP309 L2GMP309 L4GBMP310

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

SOLAR POWER METER TM-206. User s Manual HB1TM

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

Always there to help you

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

GLOSS METER OPERATION MANUAL

Portable Document & Image Scanner. User s Manual

OPERATING INSTRUCTIONS

Users Manual OPN Pocket Memory Scanner

Always there to help you. Register your product and get support at SHQ7900. Question? Contact Philips.

Multi-touch Touch-Screen. Installation Guide

Heavy Duty Datalogging Light Meter

Dome Network Camera. Quick Start Guide

Powergate³ User. Instruction manual and user s guide

High Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting

ET130 ENGLISH. INSTRUCTION MANUAL Light Meter MEASUREMENTS IN FOOT CANDLES (FC) AND LUX DATA HOLD MAX/MIN BACKLIT LCD SCREEN

Table of Contents UK/ N. IRELAND HELPLINE REP. IRELAND HELPLINE

Operating Instructions

MX3 BT LED Party Tube

STYLISH LED DESK LAMP WITH DIFFERENT LIGHT MODES

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

Always there to help you. Register your product and get support at TX2BT. Question? Contact Philips.

CENTER 521 INSTRUCTION MANUAL 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S)

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

11 in 1 Environmental Meter

Always there to help you. Register your product and get support at SHB7150. Question? Contact Philips.

Card Enrollment Station. User Manual UD05870B

CONTENTS. Model no: NT-013

IR Network Speed Dome

Always there to help you Register your product and get support at SBT300/12. Question? Contact Philips.

MULTI-FIELD EMF METER TM-190. User s Manual

Portable CD/MP3 Stereo

User Guide for Nokia Image Viewer SU-5

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

* When purchased as baby monitor set A , only one manual and warranty card is included. English 16

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

Transcription:

RADIOMETER PHOTOMETER NDTM-10 INSTRUCTION MANUAL PPUH SONOPAN Sp. z o.o. ul. Ciołkowskiego 2/2 15-950 Białystok, Poland phone/fax: +48 85 742 36 62 http://www.sonopan.com.pl July 2017

TABLE OF CONTENTS 1 INSTRUMENT CHARACTERISTIC...3 1.1 Equipment...3 1.2 Construction...3 1.2.1 Measuring probe...3 1.2.2 Integrating meter...4 1.3 Measured quantities...4 1.4 Technical data...4 1.5 Firmware update...5 2 OPERATION...5 2.1 Powering the instrument...5 2.2 Battery indicator...5 2.3 Measure...6 2.4 Menu...6 2.4.1 Zeroing...7 2.4.2 Memory...7 2.4.3 Calibration...7 2.4.4 Setup...7 2.4.5 Measuring ranges...8 2.5 Turning off the instrument...8 2.6 Calibration procedure...8 3 COMMUNICATION WITH PC...9 4 SAFETY DURING MEASURES...9 5 RECOMENDATIONS FOR ISTRUMENT USE...9 6 MAINTENANCE AND REPAIRS...9 7 CE MARKING AND CONFORMANCE TO EU COUNCIL DIRECTIVES...10 2

1 INSTRUMENT CHARACTERISTIC Radiometer-Photometer NDTM-10 is two-channel, integrating meter designed for checking viewing conditions during non-destructive testing (NDT) by magnetic particle inspection (MPI) method. That kind of test is used to detecting surface and slightly subsurface discontinuities in ferromagnetic materials such as iron, nickel, cobalt and some of their alloys. The meter has two measuring channels: VIS high quality luxmeter, UVA UV-A range photometer. Technical specification of the instrument conforms to standards: ISO/CIE 19476 Characterization of the performance of illuminance meters and luminance meters. EN ISO 9934 Non-destructive testing Magnetic particle testing Part 1: General principles. EN ISO 3059 Non-destructive testing Penetrant testing and magnetic particle testing Viewing conditions. 1.1 Equipment Basic equipment: two-channel measuring probe, two-channel integrating meter, two LR03 batteries, instruction manual, warranty card. Extra equipment: photometric probe handle, USB cable. 1.2 Construction 1.2.1 Measuring probe Measuring probe s input window is common to both channels, what provides the same directional characteristic and doesn t introduce additional error resulting from detectors shift for small measuring distances. The position of reception plane, with respect to which distance between source and probe is measured, is marked on the cylindrical surface of the probe by white dash (8.3mm from the front surface). white line indicating the position of measuring probe's reception plane Fig.1. The position of measuring probe s reception plane. 3

1.2.2 Integrating meter Keyboard and LCD screen is located on the front panel of the meter. Measuring probe socket is on the top panel, battery compartment and mini USB socket are on the bottom panel. USB socket can be used to firmware update and meter control. 1.3 Measured quantities NDTM-10 meter allows a simultaneous measurement of: illuminance (VIS channel), UV-A irradiance (UVA channel). The result of the single measure is 1 second average value. Measured values are displayed on LCD with resolution specified in 1.4 Technical data, reduced to 4 oldest significant digits. 1.4 Technical data 1) 2) 3) UVA channel VIS channel Spectral matching according to EN ISO 3059 V(λ) CIE matching quality λ 1/10 320 395nm f 1 ' 2) 3% λ 1/2 337 385nm λ max 365nm S λ=313nm < 5% S λ=405nm < 0.5% Direction matching matching quality cosine f 2 1) 3% cosine f 2 2) 3% Nonlinearity f 3 1) 0.5% f 3 2) 0.5% Measuring range 3) 100 W/m 2 (10 mw/cm 2 ) 10 000 lx Resolution 0.01 W/m 2 (1 µw/cm 2 ) 0.1 lx Measurement memory Power supply Environmental conditions temperature relative humidity 20 cells 2x LR03 batteries (1.5V, AAA size) -10 +50 C 90% (without condensation) Dimensions meter 107 72 19mm (without measuring probe socket) measuring probe Ø44 x 25.5mm measuring probe cable length 1.5m Weight with measuring probe and batteries 335g Characterizing the Performance of Integral Measuring UV-Meters. Final Report of WG1 Thematic Network for Ultraviolet Measurements. November 2000. ISO/CIE 19476 Characterization of the performance of illuminance meters and luminance meters. Minimum value guaranteed by manufacturer. Real value depends on sensitivity of used detector. 4

Fig.2. Relative spectral sensitivity of both VIS and UVA channels. 1.5 Firmware update NDTM-10 firmware can be updated by user. Update procedure is as follows: Download SonBoot application from the manufacturer s website. Download NDTM-10 firmware from the manufacturer s website. Connect the meter to PC by USB cable. Wait for proper drivers installation. Run SonBoot application. Select NDTM-10 from the Device type list Select connected meter from USB Device list Open firmware file. Turn on the meter. Push Program button. 2 OPERATION 2.1 Powering the instrument Before turning on the instrument, two AAA size batteries should be placed in the battery compartment according to the polarity marked on the back panel of the meter. High capacity alkaline batteries should be used, i.e. LR03 type. The meter turns on by pushing and hold for a while button. After turning on, meter name and firmware version is displayed on the LCD screen. That screen will disappear after about 15 seconds or after pushing any key. On welcome screen pushing buttons enters set contrast menu (look at: 2.4.4.1 Contrast). After welcome screen disappears results screen is displayed. Result screen contains: VIS channel measured value, expressed in lux, UVA channel measured value, expressed in W/m 2 or W/cm 2 depends on user setting (look at: 2.4.4.4 UVA unit), battery indicator, RUN / PAUSE indicator. 2.2 Battery indicator Battery indicator is displayed in the top right corner of the results screen: battery full, battery partially discharged, 5

battery discharged, battery discharged to critical level meter can automatically power off in any time, meter power supplied from USB port (look at: 3 COMMUNICATION WITH PC). 2.3 Measure The measurement starts and pause using button. RUN / PAUSE indicator is displayed in the bottom right corner of the results screen:: measure paused, last measured values are presented, measure is running, current measured values are presented. Measured results from both channels are displayed with measured units. Also, unit prefixes are used:: µ "micro" 10 6, m "milli" 10 3, k "kilo" 10 3, M "mega" 10 6. In the case of measuring range overload, overload indicator is displayed in front of measured value. Overload is signaled when at least one actual value of the one second average is higher than measurement range. In that case, average value can be much less than high limit of measured range but it is saddled with significant error. 2.4 Menu To change parameters and settings of the meter hierarchical menu system was developed. Menu is organized as follows: Zeroing Memory Save Load Results Erase Calibration VIS UVA Setup Contrast Autooff Backlight UVA unit W/m 2 W/cm 2 Language Polish English Measuring ranges Menu is called by pushing button. Buttons are used to menu navigation. Button confirms the choice, button is used to back to previous level of menu or cancel. If the number of menu items don t fit the on the screen, indicators appear to inform about invisible positions. 6

2.4.1 Zeroing That option is used to detectors dark current and measurement channel offset voltage compensation to set indication to zero when there is no input signal in both channels. CAUTION: Zeroing can be started only when measuring probe is covered. Otherwise, measured results will be inaccurate. 2.4.2 Memory The instrument is equipped with a measurement memory. Using the memory is possible from menu system level, by submenus: save, load, erase. Once you have selected one of the three available options, you will see a list of memory cells. The list shows the illuminance and irradiance values in the cell, or "none" if the cell is empty. Use the keys to select an active memory cell. performs a save, load or erase operation. In erase submenu, using button when empty cell is selected erase all measurement memory (this operation requires additional confirmation in the dialog box shown). 2.4.3 Calibration This menu allows to check calibration factors and to adjust indicated value by changing that calibration factors in both channels. After entering the menu, calibration factors for both channels are displayed. Measuring channel should be selected. On the next screen current measured value is displayed. This number should be edited to obtain proper measured value, using buttons to change digit value or unit prefix and button to select active digit and unit prefix. After pushing button, old and new calibration factors are displayed. Another pushing of button accept changed calibration factor value. Pushing key in any time cancels adjustment and back to the main adjustment menu. 2.4.4 Setup 2.4.4.1 Contrast In this menu LCD contrast can be adjusted. Changing of contrast is made using buttons. Button turns backlight on and off during regulation. New contrast setting can be accepted using button. 2.4.4.2 Autooff function This setting allows to save battery life. When the option is turned on, instrument will be switched off after set time from last pushing of any button. Buttons turn the function on or off. Autooff time can be set using are used to buttons to change value of the digit and button to change active digit when the function is ON. Time is set in format: hh:mm:ss (hours, minutes, seconds). The minimal time is 30s. New setting can be accepted using button. 2.4.4.3 Backlight This menu allows to manage meters backlight. There are three options, which can be changed using buttons: On backlight always on (shortest battery life), Off backlight always off (maximum battery life), 7

Auto backlight on during set time after button pushing (compromise between user s comfort and battery life). After choosing position "Auto", time can be set using buttons to change value of the digit and button to change active digit. Time is set in format: hh:mm:ss (hours, minutes, seconds). New setting can be accepted using button. 2.4.4.4 UVA unit In this menu irradiance units can be changed. Available possibilities: W/m 2, W/cm 2. The choice is performed using buttons and new setting can be accepted using button. 2.4.4.5 Language In this menu language of the menu can be changed. Available possibilities: Polish, English. The choice is performed using buttons and new setting can be accepted using button. Language is changed on the fly, just after selecting a new one. 2.4.5 Measuring ranges This menu allows to check of real measuring ranges for both VIS and UVA channels. These measuring ranges are strictly connected with calibration factors and are result of varied sensitivity of used detectors (look at: note 3) in section 1.4 Technical data). 2.5 Turning off the instrument To turn off the instrument push and hold button for at least 2 seconds. 2.6 Calibration procedure Calibration is the process of finding a relationship between two quantities, one of which is standard value and second one which is unit under test. After calibration adjustment can be made, to adjust the indication of the instrument to the applied standard value. Calibration (including adjustment) should be conducted not less than once a year. Calibration procedure: Place proper standard on photometric bench (illuminant A for VIS channel or 365nm monochromatic source for UVA channel). Place measuring probe in the axis of the radiation source. Calculate proper value of illuminance or irradiance, using standard value and measured distance between probe s reception plane (look at: 1.2.1 Measuring probe) and the source, or measure that value using reference meter. Using NDTM-10 meter, measure illuminance / irradiance. Adjustment procedure: Enter to meter s menu and select option Calibration. Select proper channel. Enter previously calculated or measured proper value of measured quantity and accept a new calibration factor (look at:2.4.3 Calibration). 8

3 COMMUNICATION WITH PC NDTM-10 is equipped with mini USB socket for PC connection. After first connection, proper drivers should be installed by system. This communication interface can be used to firmware update (look at: 1.5 Firmware update) or unit control using dedicated software. After connection of USB cable, meter turns on automatically and is powered from USB port. Then meter cannot be turned off using keyboard. Meter turns off after USB cable disconnecting. 4 SAFETY DURING MEASURES NDTM-10 instrument is designed to ultraviolet radiation measurement which is dangerous for human health. Special care should be taken during measurement, eyes and skin protections should be used to reduce ultraviolet radiation dose. During using NDTM-10 meter to non-destructive testing it is essential to follow the recommendations contained in section 5 of EN ISO 9934-1 standard. 5 RECOMENDATIONS FOR ISTRUMENT USE It is not recommended to expose instrument on falls, shakes neither on any other factors that might cause mechanical damages. Protect instrument from excessive moisture and aggressive chemical agents that may damage the meter. The measuring probe cover should be removed only at the time of the measurement. In the case of dirty measuring probe dome, unscrew the stepped ring, as shown on the picture below, and clean it with a soft cloth dampened with clean alcohol Fig.3. Access to the measurement probe dome. In the case of overload of any channel, remove measuring head from the measuring field or cover the probe. Prolonged exposure with strong radiation can damage detectors. The instrument should be stored and transported in factory case. In the case of longer storage, remove batteries from the instrument. 6 MAINTENANCE AND REPAIRS Radiometer-photometer NDTM-10 requires no special maintenance treatments. Any repairs have to be performed by the manufacturer of the instrument. 9

7 CE MARKING AND CONFORMANCE TO EU COUNCIL DIRECTIVES The product described in this instruction conforms to following EU Council Directives: 2004/108/EC Electromagnetic compatibility. The conformance to above-mentioned requirements is confirmed by CE mark. This product cannot be thrown away with household waste. Deposit the product in an authorized electrical and electronic waste collection area for recycling. Contact local Municipal Bureau or nearest waste disposal company to get more detailed information. 10