Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Similar documents
Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

User's Manual. english

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operating instructions. Standstill monitor A / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Thread length (overall length) material

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Online data sheet. IN30-E0407K IN3000 Direct NON-CONTACT SAFETY SWITCHES

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions RFID evaluation unit DTE / / 2016

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

SM9000. Made in Germany

Installation instructions Ethernet switch EC / / 2011

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

System manual AS-i safety monitor AC041S /00 05/2013

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Datasheet - CSS 11-30S-D-M-ST

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2015

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Safety Switches CES-AR/CET-AR

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Operating instructions Memory plug E /02 11/2011

Operating Instructions

Technical Data. General specifications. Rated operating distance s n 3 mm

Inductive sensor with analog output BI15-M30-LI-EXI

Operating instructions Programming and display unit PP / / 2010

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Datasheet - MZM 100 B ST-1P2PW2REM-A

Operating Instructions

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Quick reference guide 3D sensor O3D3xx

Safety. Detection. Control. MAGNUS RFID ENG - REV

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Operating instructions AC010S Compact AS-i E-STOP safety module

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Operating instructions Electronic temperature sensor TN /00 04/2011

PSR DC/ESP4/2X1/1X2

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Technical Data. Dimensions

Operating instructions Safety sensor BNS About this document. Content

Coded Non-Contact Safety Sensor Eden OSSD

E2Q4 Square Proximity Sensor

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Operating instructions Optical distance sensor O1D / / 2008

Datasheet - RSS 36-D-R-ST

Operating instructions Optical distance sensor. O5D15x / / 2014

Datasheet - SRB 301LC/B-24V

Installation instructions Inclination sensor EC2019 EC / / 2013

Datasheet - SRB 402EM-24V

Operating instructions. Monitor FD / / 2013

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Diffuse reflection light scanner with background suppression. Dimensioned drawing

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

PSR UC/ESAM4/3X1/1X2/B

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Evaluation system for flow sensors VS / / 2013

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Operating instructions Optical distance sensor O1D / / 2012

Thread length (overall length)

Inductive sensor BI1.5-EG08-Y1-H1341

Safety coded magnetic sensor SR A series

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

to 12a Added Standard and Electrical requirements for UL table 1.1

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor BI1.5-EG08-Y1-H1341

Datasheet - AZM300Z-ST-1P2P-A

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Operating instructions Control monitor for temperature sensors TR /00 04/2011

ETD-BL-1T-OFF-CC- 10S

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Operating instructions IO-Link master CabinetLine AL19xx

Transcription:

Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23

Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding the application...4 3 Items supplied...5 4 Functions and features...5 5 Function...6 5. Enable zone...6 6 Installation...7 6. Protection against simple defeating...7 7 Electrical connection...8 7. Operation as 4-wire unit...8 7.2 Operation as 3-wire unit...8 8 Operation...9 8. Switching state of the outputs...9 8.. The safe state...9 8..2 The switched state...9 8..3 Output characteristics...9 8..4 Cross fault / short circuit...9 8.2 Response times... 8.3 LED display... 9 Technical data...2 Troubleshooting...4 Maintenance, repair and disposal...4 2 Approvals / standards...5 3 Terms and abbreviations...5 2

Preliminary note The instructions are part of the unit. They are intended for authorised persons according to the EMC and Low Voltage Directives and safety regulations. The instructions contain information about the correct handling of the product. Read the instructions before use to familiarise yourself with operating conditions, installation and operation. Follow the safety instructions.. Explanation of symbols Instructions Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. LED on LED off LED flashes (2 Hz) LED flashes quickly (5 Hz) 3

2 Safety instructions Follow the operating instructions. Improper use may result in malfunctions of the unit. This can lead to personal injury and/or damage to property during operation of the machine. For this reason note all remarks on installation and handling given in this document. Also adhere to the safety instructions for the operation of the whole installation. In case of non-observance of notes or standards, especially when tampering with and/or modifying the unit, any liability and warranty is excluded. If the sensor is damaged, the safety function cannot be guaranteed. Errors caused by damage cannot be detected by the sensor. The unit must be installed, connected and put into operation by a qualified electrician trained in safety technology. The applicable technical standards for the corresponding application must be complied with. For installation the requirements according to EN 624 must be observed. In case of malfunction of the unit please contact the manufacturer. Tampering with the unit is not allowed. Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. After installation, maintenance or repair of the system perform a complete function check. Use the unit only in specified environmental conditions ( 9 Technical data). In case of special operating conditions please contact the manufacturer. Use only as described below ( 4). 2. Safety-related requirements regarding the application It must be ensured that the safety requirements of the respective application correspond to the requirements stated in these instructions. Observe the following requirements: Take measures to avoid metallic objects being placed on the sensing face unintentionally. Adhere to EN 88 for interlocking devices associated with guards. 4

Adhere to the specified operating conditions ( 9 Technical data). Use of the sensor in the vicinity of chemical and biological media as well as ionising radiation is not permitted. Adhere to the principle of normally closed operation for all external safety circuits connected to the system. In case of faults within the fail-safe sensor which result in the defined safe state: take measures to maintain the safe state when the complete control system continues to be operated. Replace damaged units. 3 Items supplied fail-safe sensor GF7S with 2 M2 fixing nuts, original instructions GF7S, ident no. 8528. If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. 4 Functions and features The fail-safe inductive sensor GF7S detects metal without contact. Safety function SF: the safe state (output stage switched off; logic "") is achieved when undamping greater than or equal to the safe switch-off distance s ar ( 9 Technical data). Also observe the notes on installation of the sensor ( 6 Installation). The fail-safe sensor conforms to Performance Level d according to EN ISO 3849 as well as to the requirements SIL 2 to IEC 658 and meets SILcl 2 to IEC 626. The unit corresponds to the classification I2A2SP2 to IEC 6947 5 2 for nonflush installation ( 6 Installation). The fail-safe inductive sensor has been certified by TÜVNord. 5

5 Function LEDs "" "" : fail-safe sensor 2: close zone 3: enable zone 4: safe switch-off distance s ar 5: target Yellow signal LED: switching status Green power LED: operating voltage 5. Enable zone The outputs (OSSD) are only enabled when a damping target is present in the enable zone. Outside this enable zone the outputs remain switched off. The safe switch-off distance s ar is > 6 mm. The enable zone is different if damping elements which deviate from the standard target plate in terms of material, form and size are used. Enable zone for selected materials*: Material FE36 (= mild steel) Stainless steel AIMg3G22 CuZn37 Copper Enable zone.5...4 mm...3. mm...8 mm...2. mm...2 mm * Typical values for damping with a reference target of 2 x 2 x mm and non-flush installation to EN 6947-5-2 at an ambient temperature of 2 C. Depending on the characteristics of the damping element there may be no close zone. 6

6 Installation The unit is non-flush mountable according to IEC 6947-5-2, type I2A2SP2. Ensure the unit cannot work loose (tightening torque 7 Nm). Adhere to the installation conditions in accordance with the figures to 3: 2 3 2 2 8 2 48 24 Tighten the socket according to the manufacturer's indications. Observe the tightening torque for the ifm socket (e.g. EVxxxx:.6...5 Nm). Flush installation of the fail-safe sensor is not permitted since this can result in an increase of the sensing range up to enabling of the outputs (OSSDs). 6. Protection against simple defeating The fail-safe sensor reacts to metal objects, e.g. the frame of a safety door. Other metal objects that are not intended to enable the sensor must not be allowed to enable the fail-safe sensor unintentionally. Take measures to prevent metal objects, except the designated target, from being placed on the sensing face or in the enable zone unintentionally. 7

7 Electrical connection Disconnect power. Also disconnect any independently supplied relay load circuits. Supply voltage: connect L+ to pin and L- to pin 3 of the connector. The nominal voltage is 24 V DC. This voltage may vary between 9.2 V and 3 V incl. 5 % residual ripple to EN 63-2. In case of a single fault the supply voltage must not exceed a maximum of 4 V DC. (This requires the safe separation between power supply and transformer.) 7. Operation as 4-wire unit L+ +24 V 2 3 A L IN GND 4 A2 IN2 : safety-related logic unit * 7.2 Operation as 3-wire unit L+ +24 V 2 3 A L IN GND 4 A2 IN2 : safety-related logic unit * * When there is no current flow on the output stage, back feeding > 3.5 V will lead to malfunction. 8 In case of operation as 3-wire unit only A2 must be used as output (OSSD). Otherwise the safety function of the sensor will be impaired or prevented. Connect output A to supply voltage.

Make absolutely sure to exclude cross faults and short circuits between the supply voltage and output A2 by means of appropriate installation. The indicated values regarding the safety function ( 9 Technical data) remain unchanged. 8 Operation 8. Switching state of the outputs 8.. The safe state The safe state is when at least one of the outputs A or A2 (OSSDs) is switched off (zero-current state: logic ""). If one of the outputs A or A2 is switched off, the subsequent safety-related logic unit must bring the complete system into the state defined as safe. 8..2 The switched state If the damping element is in the enable zone and if there is no sensor error, both outputs A and A2 (OSSDs) are enabled (logic ""). 8..3 Output characteristics The output characteristics are compatible with the input characteristics to EN 63-2 type or 2: Logic "" 5 V 2...5 ma V 5...3 ma Logic "" 5 V leakage current.2 ma 8..4 Cross fault / short circuit A cross fault between both outputs (A and A2) is detected by the fail-safe sensor and results in the outputs (OSSD) being switched off at the next safety request. The outputs A and A2 remain switched off until the error has been removed or a voltage reset has been carried out. A cross fault (short circuit) between output A2 and the supply voltage results in the other output A being switched off in case of a safety request. A short circuit of A and L+ leads to operation as 3-wire unit ( 7.2). When there is no current flow on the output stage, back feeding > 3.5 V will lead to malfunction. The device carries out self-tests for the switch-off capability on A2. 9

8.2 Response times Response time on safety request (removal from the enable zone) Response time when approaching the enable zone (enable time) Risk time / response time for safety-related faults Simultaneity of switching on and off of the outputs in case of a safety request Duration of switch-off test pulses on output A2 () Sequence of the switch-off test pulses on A2 (2) typ. max. min. ms ms 2 ms ms ms 8 ms 3 ms ms t : switch-off test pulse 2: sequence of the switch-off test pulses

8.3 LED display LED Operating status Outputs A (OSSD) Signal Power A2 (OSSD) No voltage supply Both outputs switched off Signal Power Undervoltage Overvoltage Both outputs switched off Signal Power Sensor fault ( Troubleshooting) One output or both outputs switched off Signal Power Damping element in the enable zone Damping element in the close zone Both outputs enabled Output A2 is switched off

9 Technical data Inductive sensors Made in Germany Product characteristics Fail-safe inductive sensor Metal thread M2 x M2 connector Enable zone.5...4 mm; [nf] non-flush mountable Complies with the requirements: EN ISO 3849-: 28 category 2 PL d IEC 658: SIL 2 IEC 626: SILcl 2 Application Type of operation continuous operation (maintenance-free) Electrical data Electrical design DC PNP Operating voltage Rated insulation voltage Current consumption Protection class [V] [V] [ma] 24 DC (9.2...3 DC) 3 < 2 III Reverse polarity protection yes Power-on delay time [s] Outputs Output function 2 x OSSD (A and A2) Output voltage at 24 V compatible with EN 63-2 inputs type, 2 Voltage drop Current rating [V] [ma] < 2.5; (3 ma) Short-circuit protection Range Enable zone [mm].5...4 Safe switching off distance s(ar) [mm] 6 Reaction times Response time to safety request [ms] Response time when approaching [ms] the enable zone (enable time) Risk time (response time for safety [ms] -related faults) 2 ifm electronic gmbh Friedrichstraße 4528 Essen GB GF7S-2 9..23 yes 2

Environment Applications Ambient temperature [ C] Rate of temperature change [K/min].5 Max. relative air humidity [%] Air pressure [kpa] 8...6 Height above sea level [m] 2 Ionising radiation Salt spray [h] [/h] Class C to EN 6654- weatherproof application -25...7, for service life 876 h...4, for service life 752 h 5...95, briefly 5...7, permanently not permissible Protection IP 65 / IP 67 Tests / approvals EMC IEC 6947-5-2 Shock resistance IEC 6947-5-2 Vibration resistance IEC 6947-5-2 Safety classification Mission time TM Safety-related reliability PFHd MTTFd [Years] 2 Weight [kg].6 no 752, (2 years).e-7 DC/CCF/Cat. 87 % / 7 % / 2 Mechanical data Mounting Housing materials Displays / operating elements non-flush mountable stainless steel 36L /.444; PBT Display LED yellow (signal), LED green (power) Electrical connection Connection Wiring M2 connector; Gold-plated contacts : Safety-related logic unit Accessories Accessories (included) Remarks Remarks 2 lock nuts Unless stated otherwise, all data refer to the 2x2x mm reference target plate to IEC 6947-5-2 (FE36 = mild steel) over the whole temperature range. Pack quantity [piece] ifm electronic gmbh Friedrichstraße 4528 Essen GB GF7S-2 9..23 3

Troubleshooting LED display 8.3 Problem Possible cause Troubleshooting No LED display No voltage supply Apply voltage Power LED flashes and sensor does not switch Sensor does not switch, not even after undamping and redamping No close zone Undervoltage Overvoltage Sensor was brought into the safe state (logic ""). Cause: cross fault between both outputs A and A2 cross fault between output A2 and the supply voltage error in the sensor detected 3-wire operation: A and A2 reversed Due to its characteristics (material, form, size), the damping element displaces the enable zone until directly in front of the sensing face Correct the voltage ( 9 Technical data) Remove the cross fault Replace the unit Remove L+ from A2 and connect to A If possible, change the material, form or size of the damping element ( 5. Enable zone) Maintenance, repair and disposal If used correctly, no maintenance and repair measures are necessary. Only the manufacturer is allowed to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 4

2 Approvals / standards The following standards and directives have been applied: 26/42/EC European Machinery Directive 24/8/EC EMC Directive EN ISO 3849- PL d (26) Safety of machinery - Safety-related parts of control systems IEC 6947-5-2 (28) Low-voltage switchgear and controlgear: Control circuit devices and switching elements - Proximity switches IEC 658 (2) IEC 626 (25) UL 58 3 Terms and abbreviations CCF Common Cause Failure DC Diagnostic Coverage MTTF D OSSD Mean Time To Dangerous Failure Output Signal Switch Device PFH (PFH D ) Probability of (dangerous) Failure per Hour PL Performance Level PL to EN ISO 3849- SIL Safety Integrity Level SIL -4 to IEC 658. The higher the SIL, the lower the probability that a safety function will fail. SIL cl Safety Integrity Level claim limit According to IEC 626 T M Mission time Lifetime (= max. service life) 5