SCC-RLY01 Relay Module

Similar documents
SCC-AO10 Isolated Analog Output Module

SCXI -1313A Terminal Block

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

TBX-1316 High-Voltage Attenuator Terminal Block

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

Electrical. SPECIFICATIONS SH Cable

NI 6521 Specifications

NI PXI-2567 Specifications

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

NI PXI-1042 Series Power Supply Shuttle

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

SH Cable Specifications

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

Where to Start with NI ELVIS

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

NI Serial Hardware Specifications Guide

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

TBX-96 TERMINAL BLOCK

Where to Start with NI ELVIS

NI SMB-2145/2146/2147/2148

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

NI SD Card Memory Module

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

RTM Contents. Definitions. Conditions SPECIFICATIONS. High-Speed Serial Rear Transition Module for ATCA

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

You need the following to set up and use your terminal block:

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

These specifications apply to the 1 m and 3 m TriaxM-TriaxM. it in a manner not described in this document.

1- or 2-Port, High-Speed/FD, USB CAN Interface Device

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

NI 6581/6581B Specifications

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI PXIe-7971R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

NI PXIe-7976R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

NI crio-9101/9102/9103/9104

NI 9472 DATASHEET. 8 DO, 6 V to 30 V, Sourcing, 100 μs

Getting Started with the NI PCIe-8253

ATCA Contents. Definitions SPECIFICATIONS. FPGA Module for ATCA

illustrate the performance of a representative module.

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module. DSUB are referred to inclusively as the NI 9476.

1 Gbps, 20 Channel, LVDS Digital I/O Adapter Module

NI 9402 DATASHEET. 4 DIO, LVTTL, Bidirectional, 55 ns. BNC connectivity CompactDAQ counter compatibility Individually configurable channel directions

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Getting Started with the NI PCIe-1433

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

Getting Started with the NI 8234

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

Electromagnetic Compatibility Guidelines

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Note Using the PXIe-7915 in a manner not described in this document might impair the protection the PXIe-7915 provides.

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Stepper Drive. ni.com/manuals

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

C SERIES DIGITAL INPUT/OUTPUT MODULE COMPARISON

USER GUIDE Universal Motion Interface (UMI)-7764

Electromagnetic Compatibility Guidelines

Compact Vision System with USB3 Vision and Reconfigurable I/O

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

NI 9201 DATASHEET. 8 AI, ±10 V, 12 Bit, 500 ks/s Aggregate

FP-AIO-600 and cfp-aio-600

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

USB-ERB24. USB-based 24-Channel Electromechanical Relay Interface Device. User's Guide. May Rev 8A Measurement Computing Corporation.

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

Low-Cost Multifunction DAQ for USB

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

Transcription:

USER GUIDE SCC-RLY01 Relay Module Conventions The SCC-RLY01 contains one single-pole double-throw (SPDT) nonlatching relay capable of switching 5 A at 30 VDC when using an SC-2345 or SC-2350, or 250 VAC when using an SCC-68. Any single E/M Series DAQ device digital input/output (P0) line 0 to 7 can control the SCC-RLY01. The SCC-RLY01 uses positive logic. A digital high sets the relay, and a digital low resets it. In the set state, the common (COM) contact is connected to the normally open (NO) contact. In the reset state, the common (COM) contact is connected to the normally closed (NC) contact. The following conventions are used in this guide: <> Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name for example, P0 <3..0>.» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on the product, refer to the Read Me First: Safety and Radio-Frequency Interference document, shipped with the product, for precautions to take. When symbol is marked on a product, it denotes a warning advising you to take precautions to avoid electrical shock. When symbol is marked on a product, it denotes a component that may be hot. Touching this component may result in bodily injury.

bold italic monospace SC-2345 SCC Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. SC-2345 refers to both the SC-2345 connector block and SC-2345 with configurable connectors. SCC refers to any SCC Series signal-conditioning module. What You Need to Get Started To set up and use the SCC-RLY01, you need the following items: Hardware SCC-68 or SC-2345 with one of the following: SCC-PWR01 SCC-PWR02 and the PS01 power supply SCC-PWR03 (requires a 7 to 42 VDC power supply, not included) One or more SCC-RLY01 modules 68-pin E/M Series DAQ device 68-pin cable Quick Reference Label Software The latest version of NI-DAQmx Documentation SCC-RLY01 Relay Module User Guide SC-2345/2350 User Manual or SCC-68 User Guide SCC Quick Start Guide Read Me First: Safety and Radio-Frequency Interference SCC-RLY01 Relay Module User Guide 2 ni.com

Documentation for your hardware Documentation for your software Tools 1/8 in. flathead screwdriver Numbers 1 and 2 Phillips screwdrivers Wire insulation stripper You can download NI documents from ni.com/manuals. To download the latest version of NI-DAQ, click Download Software at ni.com. Note Configuring the SCC system using Measurement & Automation Explorer (MAX) is not supported on the Macintosh operating system. Device Specific Information Note For general SCC module installation and signal connection information, and information about the SCC-68 or SC-2345 carrier, refer to the SCC Quick Start Guide, available for download at ni.com/manuals. Installing the Module Caution Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting/disconnecting any signal wires. Connecting the Input Signals Plug the SCC-RLY01 into any DIO socket J(X+9), where X is 0 to 7, on the SC-2345, or into any of the four slots that correspond to P0.0 to P0.3 on the SCC-68. Note The signal names have changed. Refer to ni.com/info and enter rdtntg to confirm the signal names. Each screw terminal is labeled by pin number <1..3>. Pin 1 is the NC terminal, pin 2 is the COM terminal, and pin 3 is the NO terminal. The SCC-RLY01 contains one SPDT relay controlled by the digital line of an E/M Series DAQ device P0. line X. The value of X is determined by the number of the DIO socket, J(X+9) on the SC-2345 or SCC Mod (X + 1) on the SCC-68, where you plug in the SCC-RLY01. Figure 1 shows a circuit diagram of the SCC-RLY01. National Instruments Corporation 3 SCC-RLY01 Relay Module User Guide

E/M Series SCC-RLY01 P0.(X ) 390 Ω, 1/4 W +5 V NO 3 D GND COM 2 NC 1 Figure 1. SCC-RLY01 Circuit Diagram Caution When connecting signals >60 VDC to the SCC-RLY01 module in the SCC-68, you must use the high-voltage backshell. Figure 2 shows the high-voltage backshell. Specifications Figure 2. High-Voltage Backshell For information about how to configure the SCC-RLY01 module with NI-DAQmx, refer to the SCC Quick Start Guide. These ratings are typical at 25 C unless otherwise stated. Electrical Contact type...spdt (Form C), nonlatching Nominal switching capacity SCC-68...5 A at 250 VAC 5 A at 30 VDC SC-2345...5 A at 30 VAC 5 A at 30 VDC SCC-RLY01 Relay Module User Guide 4 ni.com

Caution The SCC-RLY01 module is derated to 30 V maximum switching voltage in the SC-2345 carrier regardless of any other voltage markings found on the SCC-RLY01 module case. Power Requirement Physical Signal bandwidth... DC to 400 Hz Contact resistance... 30 mω max Switching time Operate time (NC to NO)... 5 ms (10 ms max) Release time (NO to NC)... 4 ms (5 ms max) 1 Maximum operating speed... 30 cps at rated load Contact lifetime... 5 10 7 operations at 180 cpm (minimum) Digital power... 300 mw max +5 V... 60 ma max 1.87 cm (0.74 in.) 7.93 cm (3.12 in.) 3.55 cm (1.4 in.) Figure 3. SCC-RLY01 Dimensions Weight... 37 g (1.3 oz) 1 Excluding contact bounce time National Instruments Corporation 5 SCC-RLY01 Relay Module User Guide

Maximum Working Voltage I/O connectors...one 20-pin right-angle male connector One 3-pin screw-terminal block Field-wiring diameter...28 to 16 AWG Maximum working voltage refers to the signal voltage plus the common-mode voltage. When used with an SCC-2345 Channel-to-earth (inputs)...±60 VDC, Measurement Category I Caution Do not use for connection to signals in Measurement Category II, III, or IV. Do not connect to MAINS. When used with an SCC-68 Channel-to-earth (inputs)...±300 VDC, Measurement Category II 1 Caution Do not use for connection to signals in Measurement Category III, or IV. Isolation Voltage Environmental Channel-to-channel, channel-to-earth isolation Continuous...60 VDC, Measurement Category I Withstand...2300 V rms verified by a 5 s dielectric withstand type test Operating temperature...0 to 50 C Storage temperature... 20 to 65 C Humidity...10 to 90% RH, noncondensing Maximum altitude...2,000 m Pollution Degree (indoor use only)...2 1 For voltages >60 VDC, you must use the high-voltage backshell. SCC-RLY01 Relay Module User Guide 6 ni.com

Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note Note For EMC compliance, operate this product according to the documentation. For EMC compliance, operate this device with shielded cables. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. National Instruments Corporation 7 SCC-RLY01 Relay Module User Guide

Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) SCC-RLY01 Module Pin Assignments Figure 4 shows the I/O connector pins on the bottom of the module. 4 1 2 5 3 1 Pin 1 2 Pin 2 3 PWB Key 4 Pin 19 5 Pin 20 Figure 4. SCC Module Bottom View SCC-RLY01 Relay Module User Guide 8 ni.com

Table 1 lists the signal connection corresponding to each pin. GND is the reference for the +5 V supply. Pin Number Table 1. SCC-RLY01 Pin Signal Connections Signal 1 2 3 4 5 6 7 P0.(X) 8 9 +5 V 10 GND 11 12 13 14 15 16 17 18 19 20 National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2001 2008 National Instruments Corporation. All rights reserved. 371079D-01 Aug08