VCL-SafeComm 16 T1 Links (48 T1 Ports) (1+1 Automatic Protection Switch) Product Brochure & Data Sheet U.S.A.

Similar documents
ALIANT OMMUNICATIONS. VCL-SafeComm 16 E1 Links (48 E1 Ports) (1+1 Automatic Protection Switch) U.S.A.

V C. E1 Protection (Fail-Over) Switch Product Brochure & Data Sheet ALIANT OMMUNICATIONS. Copyright: Valiant Communications Limited INDIA

V C ALIANT OMMUNICATIONS. E3 Fail-Over (E3 Protection) Switch. Product Brochure & Data Sheet U.K. INDIA U.S.A.

V C ALIANT OMMUNICATIONS. VCL-Ethernet over DS3 Switch (Ethernet to DS3 Switch) Product Brochure & Data Sheet

V C ALIANT OMMUNICATIONS. 4 x Ethernet over T1 (IP over TDM) Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C. Automatic Ethernet Fail-over Failover Switch ALIANT OMMUNICATIONS. 1. Product Overview

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

ORION TELECOM NETWORKS INC. VCL-XC

V C. Automatic Ethernet Fail-over Failover Switch ALIANT OMMUNICATIONS. - the alternate equipment solutions. 1.

VCL-TP, Teleprotection Equipment

ALIANT OMMUNICATIONS. VCL-MegaConnect-Jr. 16 Port E1/T1 Mixed Configuration DACS and Interface Converter

V C ALIANT OMMUNICATIONS. STM-1 Optical to STM-1 Electrical Converter. Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

VCL-TP, Teleprotection Equipment with Trip Counter Display

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

V C ALIANT OMMUNICATIONS. VCL-EC E1 Echo Canceller 1U, 19 inch Version with Telnet E1, 1U Echo Canceller Product Brochure & Data Sheet

V C. VCL-DS3oP (DS3/T3 over IP) DS3 over IP / Packet / Ethernet ALIANT OMMUNICATIONS.

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

RION ORION TELECOM NETWORKS INC. VCL-EC T1 Echo Canceller 1U, 19 inch Version with Telnet. T1, 1U Echo Canceller Product Brochure & Data Sheet

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc.,

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure

VCL-E1oP (2E1 Port FE Version)

VCL-EC Voice Quality Enhancement (VQE) & T1 Echo Canceller 8 x VQE & T1 Echo Canceller per Chassis Product Brochure & Data Sheet

ORION TELECOM NETWORKS INC.

V C. VCL-T1oP (8T1 Port GE Version) 8T1 over Packet / TDM over IP ALIANT OMMUNICATIONS.

ORION TELECOM NETWORKS INC.

VCL-Ethernet over E1 10/100 Base-T / E1/100Base-FX to E1 Interface Converter Product Brochure & Data Sheet

VCL-CB RION. Intelligent E1 Channel Bank ORION TELECOM NETWORKS INC. Product Brochure & Data Sheet TELECOM NETWORKS. Headquarters: Phoenix, Arizona

ORION TELECOM NETWORKS INC.

ORION TELECOM NETWORKS INC.

VCL-Ethernet over E1 10/100 Base-T / E1/100Base-FX to E1 Interface Converter Product Brochure & Data Sheet

ORION TELECOM NETWORKS INC.

ORION TELECOM NETWORKS INC. STM-1 (Optical / Electrical) Add-Drop Multiplexer (with upto 16 E1 & 4 Ethernet) SDH Equipment

PTP 810i ALL-INDOOR SOLUTIONS

Optimux-1032, Optimux-1025

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

Optimux-108, Optimux-106

Headquarters: Phoenix, Arizona Regional Office: Miami, Florida Orion Telecom Networks Inc. Orion Telecom Networks Inc.

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

ISO 9001:2000 Certified Company

Optimux-4T1 Four-Channel T1 Multiplexer

FL MC 2000E (SM40) LC

Optimux-34 Fiber Optic Multiplexer

Gmux Modular TDMoIP Gateway FEATURES

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

PTP 810 SOLUTIONS LICENSED MICROWAVE WITH NATIVE ETHERNET AND NATIVE TDM SUPPORT IN ONE PLATFORM. PTP 810 SPECIFICATION SHEET from Release 01-00

RION TELECOM NETWORKS. VCL-T1oP (16T1 Port GE Version) 16T1 over Packet / TDM over IP.

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

RION TELECOM NETWORKS. VCL-E1oP (16E1 Port GE Version) 16E1 over Packet / TDM over IP.

Optimux-34, Optimux-25

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

16 x E1 G x Ethernet optical multiplexer

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

IFC-FDC-PRO PROFIBUS to Daisy Chain Fiber Converter. IFC-Serial-PRO PROFIBUS to Fiber Converter. Industrial Serial Fiber Converter

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

4 E1-4 x 10/100 Ethernet converter with VLAN

Prisma II Platform. Optoelectronics

Industrial Switches Industrial Switches

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

SE5908A Series SE5916A Series. 8 or 16-Port IEC Certified Industrial Rack-Mount Secure Serial Device Server FEATURE HIGHLIGHTS

Optimux-108, Optimux-106

Gazelle S1508i-2GF-4GE-PWR L2 Manageable Industrial POE Switch

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

VCL-MX Version 6 80 E1, 160Mbps Voice & Data Multiplexer. System Guide. VCL-MX Version 6 - E1 160Mbps Voice & Data Multiplexer

Port Device Server Integration Guide

Gazelle S1003i Series L2 Manageable Industrial Switch/Serial Device Server

Dialogic DSI Signaling Interface Unit Based on Dialogic DSI SS7G3x Signaling Servers

AT PAMSPAN5099B series 2-Wire/4-Wire SHDSL.bis NTU is a telecommunication

XPort Direct+ Integration Guide/Data Sheet

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

Hardened PoE Ethernet Switch

Apex Orion DATASHEET. DS-1026-E 1 of 5

Industrial Managed Ethernet Switch

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

10/100Base-TX Industrial Ethernet Extender

4TX + 1MMFX Unmanaged Ethernet Switch

Dialogic DSI Signaling Gateway Based on Dialogic DSI SS7G3x Signaling Servers

Loop-O9330 Fiber Optical Mux

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

Where to buy > Product page >

Vmux-400 GSM A-bis/A-ter Optimization Gateway

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

PT-7728/7828 Quick Installation Guide

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

Fiber optic converter audio and CAN TA OPERATION MANUAL

ASMi-54 SHDSL.bis Modem

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Transcription:

V C ALIANT OMMUNICATIONS VCL-SafeComm T Links ( T Ports) (+ Automatic Protection Switch) Product Brochure & Data Sheet U.K. Valiant Communications (UK) Ltd Central House Rear Office High Street, Hampton Hill Middlesex, TW NS, U.K. U.S.A. Valcomm Technologies Inc. 000 Ponce de Leon, Suite 0 Coral Gables, FL U.S.A. INDIA Valiant Communications Limited /, Shivaji Marg, New Delhi - 0, India

Product Description: The VCL-SafeComm, T Links ( T Ports), + Automatic Protection Switching Equipment may be used to protect upto T Links ( T Ports), and provide an alternate communication route to each T Link between any two T points. In the event of the failure of the primary (Main) T communication route, the VCL-SafeComm, T links (+ Automatic Protection Switching Equipment) automatically switches the T traffic to a secondary (standby) T route. The VCL-SafeComm, T, + Automatic Protection Switching equipment is available in a U high chassis, which may be mounted in any DIN standard,-inch rack. This product allows the user to design + (protected) redundant T routes on similar (fiber-fiber), or complementing (fiber-radio) transmission mediums. The criterion for switching between the primary (main) and the secondary (protected / standby) routes is user programmable. Criterion for switching between the primary (main) and the secondary (protected / standby) routes may be Loss-Of-Signal on T links, or AIS (All-Ones AIS alarm) condition. The criterion for switching time and recovery time between the primary (main) and the secondary (protected / standby) routes is user programmable. Data transported on the T Links is transparent and protocol independent. Applications: Providing + alternate paths between any two T Transmission mediums (active+standby). E.g.: Fiber/Fiber Radio/Fiber Radio/HDSL Fiber/HDSL etc. Example: The user may deploy the VCL-SafeComm, T, + Automatic Protection Switching Equipment to provide an alternate communication route between an optical fiber link and a radio link between any two points. In the event of the failure of the primary (optical fiber) link the T is automatically switched to the alternate route over the T radio, thus ensuring maximum uptime on all such + protected T Links. Once the primary (optical fiber) T Link on the optical fiber is restored, the VCL-SafeComm, T, + Automatic Protection Switching Equipment automatically restores the communication to the primary (optical fiber) T Link. The switching time and restoration criterion is user programmable.

Application Diagram: Figure (application) # Microwave System Microwave System T T SafeComm T Links ( T Ports) Stby Main Stby Main SafeComm T Links ( T Ports) Upto Ts Upto Ts T Fiber Converter Fiber Fiber Converter T Point-to-Point Application: May be used in a point-to-point configuration to provide + Protected /Alternate Routing Path between any two points, using diverse (or similar) T transmission mediums. Figure (application) # TYPICAL STAR CONFIGURATION #A #B #C BTS MW LINK + Redundant Link BTS + Redundant Link MW LINK + Redundant Link MW LINK BTS BSC Point-to-Multipoint Application: To provide + Redundant T Link(s) between a single (BSC) location and multiple (BTS) locations using diverse (or similar) T transmission mediums.

Figure (application) # Site A Ts Ts Ts Radio Link Ts Radio Link BSC Central Site Ts Ts T APS Ts Radio Link Optic Multiplexer T Radio Link Optic Fiber Link Optic Multiplexer Ring Protection Ts Optic Multiplexer T Radio Link Ts Optic Fiber Link Radio Link Optic Multiplexer Site B Ts T APS Ts Ts Ts Ts Ts Site C Application to provide resilient (protected) T rings over PDH networks: The VCL-SafeComm may also be used in + redundant (protected) T rings on PDH networks using diverse (or similar) T transmission mediums. How It Works - VCL-SafeComm (With Path Protection Switching) During normal operation, VCL-SafeComm sends duplicate traffic across both the working and dedicated protection T facilities while continuously maintaining the performance of both links to determine which link shall be utilized. Figure (application) # T Link Working Link T Link VCL-SafeComm VCL-SafeComm Mobile Switching Office Protection Link (Duplicate) Remote Cell Site

Features & Highlights: High density protection switching equipment (upto T Links; i.e. T Ports) To provide an independent point-to-point, protected T Link between two T USER PORTS on similar (example fiber-fiber), or dissimilar (fiber-radio) mediums To provide + T redundancy Remote system configuration and management interface through "CLI" text based commands using Telnet and GUI (Graphical User Interface) Provide + Protection Routing / Path between BSC and BTS These ensure that mission critical voice, data, control and management traffic are properly supported and maintained even during T backhaul facility outages. When the primary (working) link fails, the T traffic is automatically switched to the standby (secondary) link to ensure maximum uptime Through the comprehensive remote configuration and alarm management capabilities of the VCL-SafeComm, T, + Automatic Protection Switching Equipment the product may be used to improve network reliability and control Traffic Protection Alternate Facility Advantages Service Differentiation Agreements Increased Network Reliability Resilience Media and Path Diversity Remote Management Alarm logging and monitoring. Benefits: Competitive Service Level Back-haul Network Technology Migration User Programmable + Protection Parameters: Loss Of Signal (LOS) Alarm Indication Signal (AIS) External open/close dry contact signal. User programmable criterion for switching between Active and Standby T Links at the customers premises: Loss of T Signal (LOS) Alarm Indication Signal (AIS) External Dry Contacts Signal The Loss of Signal condition in a T may occur due to: The failure of the T Port of the customer premises equipment. Or due to loss of power to the customer premises equipment. Or due to the disconnection of the T Cable between the protection Switch and the T Port of the customer premises equipment. This Alarm indicates that a T link error has occured. This indicates the External Dry Contacts open/close state.

Security and Password Features System Access, Control and Management Options: Telnet SSH CLI Control Interface (HyperTerminal or VT0) SNMP V Traps (MIB File provided) Windows based GUI (Graphical User Interface) for easy configuration, management and access. Ability to monitor multiple units from a single NMS. OAM: Operation and Management Ports RS Serial Port USB COM Port /0BaseT Ethernet for remote access. Security and Protection Secured Access via SSH V Password Protection: Password Protection in compliance with the mandatory clauses of the GR--CORE- specifications for secured access control. Logging: Maintains a log of all successful and un-successful attempts. Logged information includes the ID and the IP address of the accessing entities. Alerts the administrator if the un-successful logging attempts exceed three. Security Audit: All access logs for up to 0 days are maintained for security audit purposes. Security log entry of any request or activity including that user-id (including IP address, if applicable), to establish user accountability Report Generation / Audit Trail Security Administration.

Mode of Operation: There are three modes in which the VCL-SafeComm T, + Automatic Protection Switch can be configured to operate in:. AUTOMATIC SWITCHING MODE. EXTERNAL TRIGGER SWITCHING MODE. MANUAL SWITCHING MODE. AUTOMATIC SWITCHING MODE: The VCL-SafeComm can be configured to operate in an AUTOMATIC SWITCHING MODE. In the automatic mode, the switch shall automatically switch and re-route the T circuits from the MAIN route to the STANDBY route if there is anais or a LOS (LOSS OF SIGNAL) alarm, on the MAIN T link route. Similarly, in the automatic mode the switch shall automatically switch back and re-route the T circuits from the STANDBY route to the MAIN route, upon the restoration of the service on the MAIN T link route. All switching parameters and link restoration parameters are user programmable. EXTERNAL TRIGGER SWITCHING MODE: Sometimes the user wants to switch the T circuits between the MAIN route and the STANDBY route when some external event occurs. In the EXTERNAL TRIGGER MODE, the user can switch between the MAIN T route and the STANDBY T route when an external trigger (such as an closed/opened physical contact) is applied to the switch. This unique feature is used by certain radios equipment suppliers, where they apply an external trigger to switch and re-route the T circuits between their main T radios and standby T radios. MANUAL SWITCHING MODE: In Manual Switching Mode, the user shall use manual Telnet commands to switch the T circuits between the MAIN route and the STANDBY route, manually, using Telnet commands. In this mode the AUTOMATIC MODE and the EXTERNAL TRIGGER MODE are both disabled and the manual commands over ride all other modes.

Front View AC Version VCL-SafeComm T Links ( T Ports) Automatic Protection Switching (APS) EQUIPMENT TELCO MAIN LINE TELCO STANDBY LINE L L L ETH OAM L OAM RESET COM PORT L USB L PORT L L PWR PWR.V DC PWR PWR.V DC DC Version VCL-SafeComm T Links ( T Ports) Automatic Protection Switching (APS) EQUIPMENT TELCO MAIN LINE TELCO STANDBY LINE L L L ETH OAM L OAM RESET COM PORT L USB L PORT L L + + - VDC INPUT PWR - VDC INPUT PWR

Technical Specifications T Interface: Number of Interfaces Total T interfaces for Main T Links for Primary T Links for Secondary T Links Line Rate T -. Mbps Line Code BZS, AMI (user programmable) Frame Structure Transparent between the two points of the T Links Bit Rate Kbps ± 0 ppm Jitter Tolerance As per ITU-T G. Output Jitter < 0.0 UI (in the frequency range of 0 Hz to 0 KHz) Pulse Mask As per ITU (CCITT) Rec. G.0 Conformity (electrical) G.0 Nominal Impedance 0 Ohms, balanced AC Power Supply Specifications Output voltage of AC Adapter 0-0 Volt AC Range of input AC voltage 0 V to 0 V AC, 0Hz / 0Hz. System Input voltage. V DC to.0 V DC, DC input polarity protection. Maximum full load output current. A at. V DC /.0 V DC Input voltage reversal protection Provided in the Card Efficiency at full load > % DC Power Supply Specifications Input DC voltage - Dual Input -V DC (nominal) Range of input voltage -V to -V DC System voltage.v Input voltage reversal protection Provided in the Card Short circuit protection Provided Power Consumption < W Operations and Maintenance (OAM) Interfaces RS serial interface for local terminal access USB serial interfaces for local terminal access /0BaseT Ethernet Interface for remote access over an IP network. Command Language Command Line Interface (English text commands)

Compliance / Regulatory EMC FCC Part Class Safety - UL Issue Operation ETS 00 0 Class. Storage ETS 00 0 Class. Transportation ETS 00 0 Class. Management and Monitoring RS serial, USB serial interfaces for local terminal access. /0BaseT Ethernet Interface for remote access over an IP network. Encrypted Password Protection. Telnet Remote access over IP links. SSH Secured remote access using Secure Shell Protocol over IP links. SNMP Traps and NMS for real time remote monitoring and management over an IP network. Automatic Link Test feature link testing at user programmable periodical intervals. Visual I/O status LED Display. NMS (with Telnet) XPort Specification Network interface Compatibility Protocols supported LEDs Management EMI Compliance RJ- Ethernet BaseT or 0BaseT-TX (auto sensing) Ethernet Version.0 IEEE0. ARP, UDP/IP, TCP/IP, Telnet, ICMP, SNMP, SSH Base-T and 0Base-TX Activity, Full/half duplex SNMP, Serial login, Telnet login, SSH - Radiated and conducted emissions complies with Class B limits of EN0: - Direct and Indirect ESD complies with EN0: - RF Electromagnetic Field Immunity complies with EN0: - Electrical Fast Transient/Burst Immunity complies with EN0: - Power Frequency Magnetic Field Immunity complies with EN0: - RF Common Mode Conducted Susceptibility complies with EN0: Mechanical Specifications Rack mounting Height Depth Width Weight Standard -Inch. DIN Rack.00 mm. 0.00 mm..00 mm.. Kg. Temperature Operating Humidity 0 0 0 C to 0 C % to % Non-Condensing

Ordering Information S. No. Part No. Product Description. VCL--APS-/T-DLX- AC0 VCL-SafeComm T Links (T Ports) + Automatic Protection Switching (APS) Equipment " Shelf U High Rack-Mount Version Supports: - Upto x T Port [0Ω RJ (F)] [ for Main T, for Primary T, for Secondary T] - x 0-0V AC Power Supply Input [Adapter Option] - x System Core Cables, Installation accessories, Documentation, System User Manual Disk etc (Set) - OAM : /0BaseT Ethernet RJ (SNMP, Telnet) and Serial Port (USB and DB- COM Port). VCL--APS-/T-DLX- AC0 VCL-SafeComm T Links (T Ports) + Automatic Protection Switching (APS) Equipment " Shelf U High Rack-Mount Version Supports: - Upto x T Port [0Ω RJ (F)] [ for Main T, for Primary T, for Secondary T] - x 0-0V AC Power Supply Input [Adapter Option] - x System Core Cables, Installation accessories, Documentation, System User Manual Disk etc (Set) - OAM : /0BaseT Ethernet RJ (SNMP, Telnet) and Serial Port (USB and DB- COM Port). VCL--APS-/T-DLX- DC0 VCL-SafeComm T Links (T Ports) + Automatic Protection Switching (APS) Equipment " Shelf U High Rack-Mount Version Supports: - Upto x T Port [0Ω RJ (F)] [ for Main T, for Primary T, for Secondary T] - x -V DC Power Supply Input - x System Core Cables, Installation accessories, Documentation, System User Manual Disk etc (Set) - OAM : /0BaseT Ethernet RJ (SNMP, Telnet) and Serial Port (USB and DB- COM Port). VCL--APS-/T-DLX- DC0 VCL-SafeComm T Links (T Ports) + Automatic Protection Switching (APS) Equipment " Shelf U High Rack-Mount Version Supports: - Upto x T Port [0Ω RJ (F)] [ for Main T, for Primary T, for Secondary T] - x -V DC Power Supply Input - x System Core Cables, Installation accessories, Documentation, System User Manual Disk etc (Set) - OAM : /0BaseT Ethernet RJ (SNMP, Telnet) and Serial Port (USB and DB- COM Port)

Notes : Technical specifications are subject to changes without notice. Windows is the registered Trademark of Microsoft Corporation, USA. Revision - September, 0 U.K. Valiant Communications (UK) Ltd Central House Rear Office High Street, Hampton Hill Middlesex, TW NS, U.K. U.S.A. Valcomm Technologies Inc. 000 Ponce de Leon, Suite 0 Coral Gables, FL U.S.A. INDIA Valiant Communications Limited /, Shivaji Marg, New Delhi - 0, India