RF switch network. RFB 2000, RFC 2010 or 2020

Similar documents
RF SWITCH NETWORK RFB 6000

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

Coupling / decoupling network (CDN)

Compact Redundancy Switch 2:1 RSCC-2

Compact Redundancy Switch 2:1 RSCC-2

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Each amplifier can be remote controlled via the standard IEEE-488 GPIB.

MANUAL & AUTOMATED STEP TRANSFORMER INA 6501 / INA 6502 USER MANUAL C

1:1 C-Band LNA Redundancy System

RF0250 RF1100 RF1200 RF1300 RF1600

Redundancy Switch Controller 1:1 RSCM1

TC-5921A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

below. AOTF Module / Optics R O B U ST. R E L I A B L E. A C C U R A T E AOTF Video Adapter (Series VA310) KEY FEATURES POTENTIAL APPLICATIONS

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

S-Band Redundant LNA Systems

DISTRIBUTION AMPLIFIER SYSTEMS

Features. Reliable High RF Shielding. Pneumatic control of lid open-close and optional test fixture motions

Multi-Channel Attenuator

TSML-W Radio Network Analyzer

TC-5972DP Pneumatic Shield Box

Taoglas Ultima Antenna Heavy Duty Screw Mount Antenna 2 x MIMO Dual-Band 2.4/5.0GHz

DCM Dynamic Contact Measuring

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

EMSwitch RF Switch Plug-In Card

R&S MSD Modular System Device Flexible antenna switching and rotator control

PLATINUM SERIES R PART NUMBER SELECTION. High performance SPDT up to 40 GHz. Our Most Important Connection is with You. SMA - SMA 2.

L-band Multiplexers. MUXL1P-4100 to 4111 RESILIENCE RELIABILITY RF PERFORMANCE CUSTOM BUILD

Features. SC Switch Control Platforn. SC2000, SCX2000, SCP2000 SCM Series Modules

SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

TC-5915A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Programmable Power Supplies 188 W 384 W HMP Series

Zone Control Unit. Features and Functions. Monitoring of up to 6 speaker circuits (basic version)

Ku-Band Solid-State Power Amplifier

464kA. 256x256 SOLID STATE SWITCH SYSTEMS. 464kA SALIENT FEATURES SYSTEM OPERATION. 464kA DESCRIPTION

Data Sheet. ProLock. 3G test set for service. Boosting wireless efficiency

COMPLIANCE 5 SOFTWARE SUITE

Modular Test System. ZTM Series

Antenna Specification Matrix Security Service

Data Sheet. ProLock. 3G test set for service. Boosting wireless efficiency

DAS Series. DIGITAL FIBER DAS SYSTEM MHz. Product Features. Applications

SPECIFICATION : MA750.A.ABICG.003. : Pantheon Antenna 5in1 MA.750 Screw-Mount (Permanent Mount) 2G/3G/4G MIMO/ GPS/GLONASS/ 2.

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

Antenna Specification Matrix Security Service

TC-5972D Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filter on all Data and DC lines. Customizable Data connections

Product Overview. 50Ω DC to 18 GHz. Rack-Mounted USB & Ethernet Control

Spectrum Analyzer GSP-730 QUICK START GUIDE GW INSTEK PART NO. 82SP-73000M01 ISO-9001 CERTIFIED MANUFACTURER

Modular Block Converter Systems

Features. Intel 45nm Atom Processor N270: 1.6 GHz

C-Band Solid-State Power Amplifiers

Technical Specifications May 2003

Specification. Pantheon MA750.W.A.ABICG.003. Part No. MA750.W.A.ABICG.003

RoentDek. RM-6 Ratemeter and Counter. Handels GmbH Supersonic Gas Jets Detection Techniques Data Acquisition Systems Multifragment Imaging Systems

R&S ZN-Z15x Calibration Units User Manual

DL-S41-H2 Quick Install Guide

Professional Monitoring Receiver for

Connector: 1 IEC plug(iec-320 C14) Current consumption:

S3101 Cable & Antenna Tester Datasheet

OR-862 / OR-862S Series optical receiver. Operation Manual

IFR 6000 Transponder/DME Ramp Test Set

40-785B Microwave Multiplexer Module

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Cisco Compact EGC Segmentable Node A90200

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-03S 70 MHz - 3 GHz Inline Power Monitor with SMA Connectors 1

Prisma II Platform. Optoelectronics

Agilent E5072A ENA Series Network Analyzer

VIPEDIA-12. Cameo specification sheet. Product Description

Technical Document. Antenna Specification Matrix. For internal and detachable antennas provided with ZyXEL access points

4-Port HDMI KVM Switch - USB p

DVIMUX IMUX DVIMUX DVIMUX DVIMUX DVIMUX DVIMUX DVIMUX D UX DVIMUX DVIMUX DVIMUX DVIMUX DVIMUX DVIMUX DVIM. KVM Switches

Corning Optical Network Evolution (ONE ) Solutions Mid-Power Remote Expansion Unit (MxU)

Control Panel CP600 CP651, CP651-WEB

3+1 U CPCI Serial System

MIMO Junior Evo MMJ342LV

DFI Redefines Flexibility Through a Series of Modularized Embedded Systems for... Industrial Automation

ap 2-w cybox ap 2-w Industrial and Mobile IEEE ac Dual Radio Wireless Access Point

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

SPECIFICATION. IS MHz Hercules ISM Band Antenna. Product Name : 915 MHz Hercules ISM Band Antenna Screw-mount (Permanent mount)

LAUREL ELECTRONICS, INC.

HP4 headphone amplifier. user manual

Control Panel CP600-eCo CP604, CP604-B

SPECIFICATION. IS MHz Hercules ISM Band Antenna. Product Name : 868MHz Hercules ISM Band Antenna Screw-mount (Permanent mount)

INT-HD52 Quick Install Guide

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model VC-SHIELD Shield Box

464kC SOLID STATE SWITCH SYSTEMS. 464kc SALIENT FEATURES SYSTEM OPERATION. 464kC DESCRIPTION

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Specification. Part No. : MA9908.A.001. Product Name : GuardianX 1M 8in1 1*Active GNSS 4*LTE MIMO. Features : Low-profile Housing with Wall Mount

Control Panel CP600 CP635, CP635-B, CP635-WEB

DVI KVM Switches DVIMUX-DL 7.2

D.C.M Dynamic Contact Measurement User Manual page 1(22) INDEX GENERAL APPLICATION AREA OVERVIEW SAFETY...

NetCom Plus 413 (NetCom 413, NetCom 413 PRO)

Keysight Technologies M9309A PXIe Vector Network Analyzer Synthesizer

Antenna Distributor ORDERCODE D1444

Isolated Process Current Input with Loop Power 7B35

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Transcription:

RFB 000, RFC 010 or 00 The can be configured to switch RF signals in a wide range of automatic test systems. Various switch configurations are available, connecting one input to either two or six outputs. The 3HU rack consists of a power supply and remote interface and can accept any combination of plug-in modules up to the maximum dimension of the rack. Each switch can be individually controlled through RS 3 or USB interface to ensure maximum flexibility in the test system. RF Switch network, view to the front panel, example with x to 1 switch N type All RF switches are high quality with an operating lifetime of at least one million operations. While able to pass high power levels, they are designed to switch only during absence of RF power. Applicable for various RF systems Modular system, extendable Quasi unlimited switch numbers RS 3 or USB remote interface High quality switches Front panel Example of x to 1 switch N type Mains switch and LED Switch type for the front panel Connectors Action Max. possible switches of this type at front View to the back panel, example with RS3 interface, x to 1 switch N type and 1x 6 to 1 switch SMA type NFS 100A N type 1 to 10 SFS 100A SMA type 1 to 10 SFS 1600A SMA type 1 to 6 5

RFB 000, RFC 010 or 00 Back panel supply input 100-0 V AC, fuse Remote control via USB (option RFC 010) or RS3 (option RFC 010) System control, connection to a second switch or mainframe Switch type for the back panel Connectors Action Max. possible switches of this type at back NRS 100A N type 1 to 8 SRS 100A SMA type 1 to 8 SRS 1600A SMA type 1 to 6 Technical specification supply: 100-0 V AC / 7-63Hz Remote control: USB (option RFC 010) or RS3 (option RFC 010) RF Impedance of the switches: 50 Ω RF Isolation between the ports: 55 db Switch life time: 1M switch cycles (absence of RF power during switching required) Operating temperature: 5-50 C Humidity: < 80% (not condensation) Dimensions (W/H/D in mm): 83 x 150 x 3 Weight: approx. 10 kg

7 8 9 5 6 1 3 0. MHz dbµv khz dbm Hz V Enter USB USB RFB 000, RFC 010 or 00 Example of a setup with power amplifier, 3 directional couplers, 1 power meter and antennas RF switch network Signal generator Software 1 to 6 Switch (option SRS 1600A of the ) meter Meter C 1 3 6 5 C 1 3 6 5 1 C 1 C amplifier 1 to 1 to 6 Switch (option SRS 1600A of the ) 1 to Switch (option SRS 100A or NRS 100A of the ) EUT EUT Note: Teseq recommends a short distance between directional coupler and power meter for all applications above 1 GHz. The best solution is a direct mounted power meter on the directional coupler port.

RFB 000, RFC 010 or 00 Max. average power N type, SMA type Max. average power in Watts 1000 100 10 0.1 1 10 18 Insertion loss N type, SMA type 0.7 0. Insertion loss in db 0.3 0. 0.1 0 0 5 10 15 18

RFB 000, RFC 010 or 00 VSWR N type, SMA type 1.8 1.6 1. 1. 1.0 0.8 VSWR 1: 0. 0. 0 0 5 10 15 18 Model range and options Part number Description 800 RFB 000 RF-Switch: Main unit for 19" rack without switches 803 RFC 010 RF-Switch: USB interface (required RFB 000) 8033 RFC 00 RF-Switch: RS3 interface (required RFB 000) 80 SFS 100A Plug-in module for front panel with switch 1 to, SMA 803 NFS 100A Plug-in module for front panel with switch 1 to, N 805 SFS 1600A Plug-in module for front panel with switch 1 to 6, SMA 806 SRS 100A Plug-in module for rear panel with switch 1 to, SMA 807 NRS 100A Plug-in module for rear panel with switch 1 to, N 809 SRS 1600A Plug-in module for rear panel with switch 1 to 6, SMA Teseq GmbH Landsberger Str. 55 163 Berlin Germany T + 9 30 56 59 88 35 F + 9 30 56 59 88 3 desales@teseq.com www.teseq.com 8-800 E01 Jul. 01 Teseq is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of ISO 9001. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies. Specifications subject to change without notice.