Product and Applications Description

Similar documents
Product and Application Description

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016.

Use of the application program

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Application program usage. Functional description. instabus EIB Application Program Description. December IP-Router

Application program usage. Functional description. instabus EIB Application Program Description. March IP-Router

Product and functional description

Product and functional description

Product and functional description

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

584 5WG AB_1 DELTA

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

instabus KNX / EIB product documentation

Push Button Interface UP 220D31

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and functional description

Push button UP 287, 4 - fold

Product and functional description

DELTA i-system wall switch single UP 221/2 5WG AB_2

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product and functional description

Connections, displays and operating elements C D

Contents 1. Summary

Operating and mounting instructions

252F 5WG FB_1 DELTA

Power Supply System KNX PS640-IP

Weather station GPS AP 257/61 Weather station AP 257/51

Weather station AP 257/51

Product and Application Description

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

Product and Function Description

Operation and installation manual KNX IP Router. Application. Coupler function (KNXnet/IP Routing)

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Line Coupler, MDRC LK/S 3.1, GH Q R0001

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification:

KNX USB INTERFACE UIMtp

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

Power Supply System KNX PS640+IP

KNX IP router Order No

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions

Technical Manual MDT IP Router

Technical Manual MDT IP Router

Operation and installation manual KNX IP BAOS 774. KNX IP BAOS 774 as application specific Gateway BAOS SDK. Application. Installation and Connection

Operation and installation manual KNX IP BAOS 773. KNX IP BAOS 773 as application specific Gateway BAOS SDK. Application. Installation and Connection

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli)

Application description for the KNXnet/IP Interface Web

ABB i-bus KNX AC/S Application Controller

USER MANUAL CU-DIN IPRT KNX EC MA

Product and function description

IP gateway, MDRC IG/S 1.1, GH Q R0001

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Power supply module, bus connection module

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Operating Instructions. DALI-Gateway

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating instructions Evaluation system for flow sensors VS / / 2013

Electrical devices may only be mounted and connected by electrically skilled persons.

T-TeleSec LineCrypt DSL User's Guide

Line Coupler, MDRC LK/S 2.1, GH Q R0001

Content 1 OVERVIEW HARDWARE DESCRIPTION HARDWARE INSTALLATION PC CONFIGURATION GUIDE... 5 WEB-BASED MANAGEMENT GUIDE...

Island bus expansion module

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Extension module for BACnet over Ethernet / IP and graphic Web functions

Operating Instructions VEGAMET 381

DOCUMENTATION MECrf TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 24 November 2017

Web interface BACnet/IP

SK CU4-EIP-C Part number:

USB RF INTERFACE UIMrf


Room automation station

Operating instructions. Switching amplifier DN0210 DN / / 2015

HEC. General Operating, Maintenance and Installation Manual

IP Router KNX Product manual

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

User Manual. Printer P-52RUE

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

JUMO mtron T Measuring, Control, and Automation System

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

TXM1.8RB. TX-I/O Blinds module

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating instructions. Standstill monitor A / / 2011

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Operating instructions. Speed monitor D / / 2014

CU-DIN USB KNX EC

R70 Ethernet to CAN interface Manual (1.4 EN)

Electrical Actuators

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Quick Installation Guide

Electrical Actuators

Transcription:

IP N146/02 Product and Applications Description The IP N146/02 is a DIN rail mounted device. The device implements the KNXnet/IP standard and connects KNX/EIB lines via data networks using the Internet Protocol (IP). Also this device offers concurrent access to the bus line from any PC or other data processing equipment. The physical connection to the KNX/EIB is established via a bus connector terminal block. For connection to the data network (IP via 10BaseT) the device contains an RJ45 socket. By using a LAN modem an KNX/EIB installation can be remotely accessed even if there is no direct data network connection between a PC and an IP. LAN modems are available on the market for standard telephone, ISDN or DSL connections. The IP requires additional operating power for its operation. The IP N146/02 can source this operating power via the network connection from Power over Ethernet according to IEEE 802.3af. Alternatively, the operating power can be provided via a second terminal block (white-yellow terminals) by a safety extra low voltage (SELV) power supply AC/DC 24 V or by a bus power supply (unchoked power, DC 29V). When a SELV power supply is connected the operating power is sourced from it. The IP has these characteristics: Simple connection to hierarchically superimposed systems via Internet Protocol (IP) Direct access to the KNX/EIB installation from any access point to the IP network (KNXnet/IP Tunneling) Fast communication between KNX/EIB lines, areas and systems (KNXnet/IP Routing) Communication between buildings and facilities Filtering and routing of telegrams depending on - individual address - group address LED display of - operation - KNX/EIB communication - IP communication Simple configuration with standard ETS Easy connection to SCADA and Facility Management systems (see: Supported Software) IP as line / area coupler (KNXnet/IP Routing) Using the existing data network for communication between bus lines in non-residential buildings is a logical step. The advantages are: fast communication between KNX/EIB lines, extension of an KNX/EIB system beyond one building by using LAN and WAN connections, direct transmission of KNX/EIB data to any network user, KNX/EIB remote configuration from any network access point. The IP logically connects KNX/EIB bus lines by transmitting KNX/EIB telegrams between them via a data network but separates them galvanically. This allows to run each bus line independently from other bus lines. The IP can be used as line coupler or area coupler in existing EIB networks as well as in new KNX/EIB networks. The IP holds a filter table determining, which bus telegrams are transmitted or blocked from or to the bus line thus reducing the bus load. The filter table is automatically generated by the ETS (EIB Tool Software) during configuration and start-up of the system. The physical address of the IP assigned by ETS automatically determines the IP function as a line coupler or area coupler. The definition follows these assignments: function Area coupler Main line 1-15 coupler 1-15 Siemens AG N 146/02, 8 pages Technical Manual Control Products and Systems Siemens AG 2018 Update: http://www.siemens.com/gamma-td 2.11.1.13/1

IP N146/02 IP Network IP Network Note When assigning the physical address take care that IP and line couplers receive the topologically correct physical address (Fig. 1, IP as area coupler and line coupler). 1.1.0 1.0.0 2.0.0 Main 1 Main 2 1.2.0 1.3.0 2.1.0 2.2.0 Adhere to these rules: Rule 1: In general an IP is used as a line coupler or an area coupler. The physical address has the format x.y.0, with x=1 15, y=1 15. Rule 2: If an IP is applied as an area coupler with the physical address x.0.0 then no other IP with the line coupler address x.y.0 (y=1 15) shall be placed topologically below this IP (Fig. 2, IP N 146 as area coupler). Rule 3: If an IP is applied as a line coupler (e.g. with physical address 1.2.0) then no other IP shall be used with a superior area coupler address (e.g. 1.0.0) in this installation (Fig. 3, IP N 146 as line coupler). 1.1.1 1.1.2 1.2.1 1.2.2 1.3.1 1.3.2 Figure 2. IP as area coupler 1.1.0 1.1.1 1.1.2 1.2.0 2.1.1 2.1.2 1.2.1 1.2.2 1.3.0 IP Network 1.3.1 1.3.2 2.1.0 6/3/1 6/3/1 2.1.1 6/3/1 2.1.2 2.2.0 2.2.1 2.2.2 2.2.1 IP KNX 2.2.2 Figure 3. IP as line coupler 6/3/1 IP Network Note 1.1.0 1.1.1 1.1.2 2.0.0 2.1.0 2.1.1 Main 2 2.2.0 2.2.1 EIBnetIP 3.3.0 3.3.1 3.3.2 IP KNX Smooth operation of the IP as line coupler or back-bone coupler using KNXnet/IP Routing requires LAN network components that support IP multicasting. In particular, network / LAN routers must be configurable respectively configured to forward IP multicast datagrams. The IP multicast address 224.0.23.12 was specifically reserved for KNXnet/IP internationally for this purpose. 2.1.2 2.2.2 Figure 1. IP as area and line coupler IP as interface to the bus (KNXnet/IP Tunneling) A direct connection between a networked PC and the bus can be established via a data network and the IP. This allows for accessing the bus from any access point in the data network. The IP N146/02 provides up to four KNXnet/IP Tunneling connections, allowing for e.g. simultaneous configuration with ETS and operation of a visualization. Technical Manual N 146/02, 8 pages Siemens AG Update: http://www.siemens.com/gamma-td Siemens AG 2018 Control Products and Systems 2.11.1.13/2

IP N146/02 Note For stable communication via KNXnet/IP Tunneling the IP must use a separate individual address for each KNXnet/IP Tunneling connection. These additional individual addresses must be different from the individual address of the device and must not be used by any other bus device. In ETS (before ETS5) these individual addresses should be reserved by proxy devices. ObjectServer interface to the bus A direct connection between a networked PC and the bus can also be established via a data network and the IP N146/02 using ObjectServer. ObjectServer compared with KNXnet/IP Tunneling provides the advantage that the communication can be maintained even over network connections with a transmission time for the datagrams of over one second (e.g. satellite connections). Assignment of additional individual addresses Additional individual addresses are either assigned with ETS (refer to APB for detailed description) or alternatively without a tool automatically by the device itself. The automatic address assignment for KNXnet/IP Tunneling and ObjectServer is started when the learning button is pressed during normal operation for more than 5 seconds but less than 10 seconds. The programming LED flashes during the address assignment process. The device checks which individual addresses are already used by other bus devices connected to the bus line. These addresses are not used for the address assignment. By adding additional bus devices at a later time one or more of the additional individual addresses could be assigned twice. When during normal operation the learning button is pressed for more than 10 seconds all additional individual addresses in the IP N146/02 are reset to the default value (15.15.255) and the programming LED is turned off. IP address assignment The IP address of the IP N146/02 is assigned manually using ETS, automatically by a DHCP server in the IP network, or by the device itself (AutoIP). Assignment of the IP address by a DHCP server allows for changes of the device IP address without using ETS. Configuration of the DHCP server may require the MAC address, which is printed on the device. If a DHCP server is not available the device assigns itself an IP address (AutoIP). Please consult your network administrator regarding configuration of the parameters device IP address, subnet mask, and DHCP. Default factory settings By default the KNXnet/IP Routing function is active. When two KNXnet/IP routers are connected with each other via a cross-over cable or via a network hub, bus telegrams are routed by the KNXnet/IP without any configuration. The IP ships with these default factory settings: Physical address of the IP : 15.15.0 (= FF00 hex) Filter group telegrams All bus telegrams are repeated in case of transmission errors The IP acknowledges routed telegrams only Support for devices with mis-matching physical address Route broadcast telegrams Monitor the bus line IP address assignment via DHCP Behavior on bus voltage loss / recovery on the bus line When the IP detects a loss of bus voltage on the bus line, this error is saved and annunciated via KNXnet/IP. When the IP detects recovery of bus voltage on the bus line, the error flag is deleted and the resumption of bus voltage is annunciated via KNXnet/IP. Application programs The IP N146/02 can be configured with the application program "IP- 001002" (from ETS2V12 on upwards) or with the application program IP- 001031 from ETS5 on upwards. When the device is configured with ETS5 and the application program IP- 001031 then the respective functions of ETS5 for configuration of the IP addresses and the dvice name are utilized. Siemens AG N 146/02, 8 pages Technical Manual Control Products and Systems Siemens AG 2018 Update: http://www.siemens.com/gamma-td 2.11.1.13/3

IP N146/02 Example of Operation Installation Instructions Ethernet TCP / IP Hub The device may be used for permanent interior installations in dry locations within distribution boards or small casings with DIN rail EN 60715-TH35-7,5. IP N 146/02 Υ WARNING Linie 1 Linie 2 Linie 3 AC/DC 24 V Linie 4 The device must be mounted and commissioned by an authorised electrician. Free DIN rail areas with sticked-in data rails must be covered with covers, order no. 5WG1 192-8AA01. The prevailing safety rules must be heeded. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Bus Technical Specifications Spannungsversorgung N 125 / 21 L N Example of Operation 1 with external auxiliary power supply IP N 146/02 Linie 1 Linie 4 Ethernet TCP / IP Hub Network communication Ethernet: 10BaseT (10 Mbit/s) Supported Internet Protocols: ARP, ICMP, IGMP, UDP/IP, DHCP, AutoIP KNXnet/IP according to KNX System Specification: Core, Routing, Tunneling, Management Rated voltage Bus: DC 24V (DC 21...30V) Auxiliary power supply: from Power over Ethernet DC 48V (acc. to IEEE 802.3af) max. 0,8W alternatively from external power supply AC/DC 24V (AC 12 24V, DC 12...30V) max. 1,7W (57mA @ DC 24V) Linie 2 Linie 3 Bus DV 29 V Spannungsversorgung N 125 / 21 L N Example of Operation 2 with auxiliary power supply from unchoked bus power supply Technical Manual N 146/02, 8 pages Siemens AG Update: http://www.siemens.com/gamma-td Siemens AG 2018 Control Products and Systems 2.11.1.13/4

IP N146/02 Power supply Bus voltage: via KNX/EIB bus line KNX bus current: 6 ma Operating voltage: from Power over Ethernet according to IEEE 802.3af, nominal voltage DC 48V alternatively, from external SELV power supply AC/DC 24V nominal, permissible input voltage range: AC 12...24V, DC 12... 30 V Recommended power supplies: DC 29V (before choke) from KNX/EIB power supply N125/21 Power supply unit 4AC2 402 Primary voltage AC 85-265V / DC 85-300V, Secondary voltage DC 24V, 2MU width safety transformers 4AC3 724-0 Primary voltage 230V AC Secondary voltage AC 12V, 3MU width safety transformers 4AC3 740-1 Primary voltage 230V AC Secondary voltage AC 12V 24V, 5MU width Υ CAUTION It is recommended to use the external safety extra low voltage power supply for the IP N146/02 only. Power usage From the bus line: max. 10mA @ DC 29V From the auxiliary power supply: max. 1,7 W (57mA @ DC 24V) Control elements 1 learning button: for switching between normal operating mode and addressing mode Display elements 1 green LED: device ready (ON) 1 yellow LED: Communication on bus line 1 green LED: Ethernet Link Signal available (Lk) 1 yellow LED: Receiving data from Ethernet (Rx) 1 red LED: Transmitting data to Ethernet (Tx) 1 red LED: for monitoring bus voltage and displaying mode, selected with the learning button Connections bus line: screwless bus connection block (red-black) 0,6...0,8 mm Ø single core remove approx. 5mm of isolation Ethernet / IP network: RJ45 socket auxiliary power: screwless extra low voltage terminal (yellow-white) 0,6... 0,8 mm Ø single core remove approx. 5mm of isolation Physical specifications housing: plastic N-system DIN-rail mounted device, width: 2 SUs (1SU = 18mm) Installation: Snap-on mounting on DIN rail EN 60715-TH35-7.50 weight: approx. 105g Fire load: approx. 2840 kj 10 % Electrical safety degree of pollution (according to IEC 60664-1): 2 protection (according to EN 60529): IP 20 protection class (according to IEC 61140): III overvoltage class (according to IEC 60664-1): III bus: safety extra low voltage SELV DC 24 V the device complies with EN 50 090-2-2 Electromagnetic compatibility complies with EN 61000-6-2 and EN 61000-6-3 and EN 50090-2-2 Environmental specifications climatic conditions: EN 50090-2-2 ambient temperature operating: - 5... + 45 C storage temperature: - 25... + 70 C relative humidity (non-condensing): 5 % to 93 % Markings KNX, EIB, CE CE mark complies with the EMC regulations (residential and functional buildings), and low voltage regulations Siemens AG N 146/02, 8 pages Technical Manual Control Products and Systems Siemens AG 2018 Update: http://www.siemens.com/gamma-td 2.11.1.13/5

IP N146/02 Location and Function of the Display and Operator Elements A1 A2 A3 A4 A8 Figure 4: Location of the display and operator elements A10 A5 A6 A7 A9 Mounting and Wiring General description The N-system DIN-rail device can be installed in N-system distribution boards, surface or flush mounted, or on any DIN rail complying with EN 60715-TH35-7,5. The connection to the bus line is established via the bus connector terminal (red-black) on the top side. The RJ45 socket on the device front side provides the connection to the Ethernet-IP data network. Mounting DIN-rail devices (Figure 5) - Slide the device (B1) onto the DIN-rail (B2) and - swivel back the device until the slide clicks into place audibly. Dismounting DIN-rail devices (Figure 5) - Remove all connected wires, - press down the slide (C3) with a screw-driver and - swivel the device (C1) from the DIN-rail (C2). A1 LED red: indicating normal operating mode (LED off) and addressing mode (LED on) A2 learning button for switching between normal operating mode and addressing mode for receiving the physical address A3 LED green: Operation A4 LED yellow: data transmission on bus line () A5 LED green: Ethernet Link signal (Lk) A6 LED yellow: Ethernet Receive signal (Rx) A7 LED red: Ethernet Transmit signal (Tx) Note When the learning button (A2) is pressed, this LED signals for 10 seconds how the IP address was assigned to the device: 1x flashing: fixed IP address 2x flashing: DHCP 3x flashing: AutoIP A8 extra low-voltage bus terminals (red-black) A9 extra low-voltage terminals (yellow-white) A10 RJ45 socket for data network cable B1 B2 C1 C2 C3 Figure 5: Mounting and dismounting a DIN-rail device Slipping off bus connection blocks (Figure 6) - The bus connection block (D2) is situated on the top of the device (D1). - The bus connection block (D2) consists of two components (D2.1 and D2.2) with four terminal contacts each. Take care not to damage the two test sockets (D2.3) by accidentally connecting them to the bus cable or with the screw-driver (e.g. when attempting to unplug the bus connection block). - Carefully put the screw-driver to the wire-inserting slit of the bus connection block's grey component and pull the bus connection block (D2) from the device (D1). Slipping on bus connection blocks (Figure 6) - Slip the bus connection block onto the guide slot and - press the bus connection block (D2) down to the stop. Technical Manual N 146/02, 8 pages Siemens AG Update: http://www.siemens.com/gamma-td Siemens AG 2018 Control Products and Systems 2.11.1.13/6

IP N146/02 Connecting bus cables (Figure 6) - The bus connection block (D2) can be used with single core conductors Ø 0,6... 0,8 mm. - Remove approx. 5 mm of insulation from the conductor (D2.4) and plug it into the bus connection block (D2) (red = +, black = -). Disconnecting bus cables (Figure 6) - Unplug the bus connection block (E1) and remove the bus cable conductor (E1.4) while simultaneously wiggling it. Dimension Diagram Dimensions in mm 90 45 D2 D2.3 D2.1 D2.2 D2 D2.4 5 mm b b = 2 SU 1 Standard unit (SU) = 18 mm 44 55 D2 D1D D2 D2.4 Figure 6: Connecting and disconnecting bus wires Slipping off / on auxiliary power connection block - Follow the instructions for the bus connection block when slipping off/on the auxiliary power connection block. Siemens AG N 146/02, 8 pages Technical Manual Control Products and Systems Siemens AG 2018 Update: http://www.siemens.com/gamma-td 2.11.1.13/7

IP N146/02 Notes on secured data transmission This KNXnet/IP device is designed for operation in a network, which is only accessible by authorized users. This device shall not be connected directly and unsecured with the Internet. If Internet access to a KNX installation is needed, then a VPN connection to the Internet shall be implemented. General Notes The operating instructions must be handed over to the client. Any faulty device is to be sent together with a return delivery note of the local Siemens office. For any technical questions, please consult: & +49 (911) 895-7222 6 +49 (911) 895-7223 ) support.automation@siemens.com www.siemens.com/automation/support-request A Virtual Private Network (VPN) establishes an encrypted and authorized connection (VPN tunnel) from a remote point into a network via the Internet. This VPN connection allows secured and eaves-dropping protected communication between a remote device and the KNX installation. Administration of access rights to this KNXnet/IP device in an IP network shall be coordinated with the responsible IP network administrator. Possible additional security measures are among others: - Switches and routers are set in such a way that only known MAC addresses are able to access the communication medium. - A separate IP network with own hardware is setup for KNX communication. - Access to the (KNX) IP network is limited to authorized persons via appropriate user names and strong passwords. - If WLAN is being used, the default SSID of the wireless access point is changed. The WLAN is encrypted with a secure (currently e.g. WPA2) method. - Ports for incoming connections of routers, especially UDP port 3671 reserved for KNXnet/IP, are closed. The network settings shall be documented and handed over to the building owner / operator or the LAN administrator. For further information on KNX security refer to the KNX Secure Checklist (https://www.knx.org/media/docs/downloads/marketing/ Flyers/KNX-Secure-Checklist/KNX-Secure- Checklist_en.pdf) and the KNX Secure Position Paper (https://www.knx.org/media/docs/downloads/marketing/ Flyers/KNX-Secure-Position-Paper/KNX-Secure-Position- Paper_en.pdf). Technical Manual N 146/02, 8 pages Siemens AG Update: http://www.siemens.com/gamma-td Siemens AG 2018 Control Products and Systems 2.11.1.13/8