Nexus Transient Recorder and Power Meter With Advanced Power Quality and Communication. Communication, I/O and User Interface

Similar documents
Nexus Next Generation Power Meter for Critical Energy Circuits. Advanced Metering and Communication

Nexus Next Generation Power Quality Meter for Critical Energy Circuits. Advanced Metering and Communication

EPM Multilin ADVANCED POWER QUALITY METER. High Performance Power Quality and Transient Recorder Meter KEY BENEFITS APPLICATIONS FEATURES

Current Fault Signatures and Analysis Auto-calibrating metrology means the meter maintains its accuracy over temperature and time

Electronic Submeter with Advanced WiFi Ethernet Capability

Nexus Cyber Secure Energy Panel Meter with Advanced Power Quality & Multiport Communication. Advanced Power Quality Analysis

SH RK 100S SH RK 200S

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

UPGRADABLE FULLY FEATURED POWER & ENERGY METER

UPGRADABLE FULLY FEATURED POWER & ENERGY METER

NEW MODERNSTE TECHNOLOGIE. Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit. Führende Technologie in der Industrie

EPM Multilin POWER QUALITY METER SERIES. High Performance Power Quality Analysis Device KEY BENEFITS APPLICATIONS FEATURES.

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance

Industry Leading Performance From Simple to Sophisticated Highly Accurate Metering Technology

Nexus1250 For Industry and Utilities

Multilin EPM 9650 & 9450

Nexus1252. Advanced Performance Power Meter and Data Acquisition Node. New Technology! Total Web Solutions

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

UW Purchase Specification Section

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Multilin EPM High Performance Power Quality Analysis Socket Meter. Monitoring & Metering. Advanced Communications. Key Benefits.

Nexus Advanced Performance Smart Power Meter. and Substation Data Acquisition Node. For Smart Grid and Substation Automation

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Designed For Reliability Manufactured To Last

Nexus 1262 /1272. Electro Industries/GaugeTech. Installation & Operation Manual Revision High Performance Socket Meter

Power Xpert Branch Circuit Monitor

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

The PowerLogic range. Gain energy insight and control

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

TFS 2100 Traveling Wave Fault Location System

Bus Bar Protection Relay B-PRO 4000

with Backlight Graphic LCD Screen

CoPilot EXT. Electro Industries/GaugeTech. Installation & Operation Manual Revision PDA Based Software

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

Power Series Transfer Switch

DIRIS N300/N600 Network analysers Network quality control and analysis system

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

SURGELOGIC TM. Surge Protective Device Transient Voltage Surge Suppressor (TVSS) XGA, XT, XF, XP Series. Class Schneider Electric Brands

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

FP-5000 Feeder Protection

PMC-630 Series Advanced Multifunction Meter

Multilin EPM 9900P. GE Grid Solutions. High Performance Power Quality and Transient Recorder Meter. Monitoring & Metering. Advanced Communications

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

SM100. On-Line Switchgear Condition Monitoring

Nexus 1262/1272. High Performance Utility Billing Meters with Communication and Advanced Power Quality. Highly Advanced Revenue Meter

Discover. BlackBox G4400. Outstanding Features. Designed for Your Needs. PQZIP Compression Technology. Elspec s Unique Technology

MIC-2 MKII, Multi-instrument DATA SHEET

PMC 530 Series Advanced Multifunction Meter

Power Series Transfer Switch

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

Nexus 1262 / Electro Industries/GaugeTech. Installation & Operation Manual Version High Performance Socket and Switchboard Meters

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

RT12-240V/2.4kW Rectifier Specification

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

Electro Industries GaugeTech

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

Nexus 1262/1272. High Performance Utility Billing Meters with Communication and Advanced Power Quality. Highly Advanced Revenue Meter

DRTS 33. The new generation of advanced three phase relay test set

Nexus1262/1272. High Performance Utility Billing Meters. With Communication & Advanced Power Quality. Accu-Measure Auto-Calibrating Metrology

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Power Series Transfer Switch

MODULAR CIRCUIT MONITORING SYSTEM

4000/6000/8000 Series

Tesseract. Technical Data sheet

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Transformer Protection Relay

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

PQM4000 and PQM4000 PQM4000RGW. Class A DIN 192x144 power quality analyzer for CTs. Class A certified in compliance with IEC/EN :2015 Ed.

PQube. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Universal Process Controller

Three-Phase Power Quality Analyzer PowerPad Model 3945

WI-I/O 9 Multi I/O Units

Power System Monitoring Recorder

Scout-S Station Controller

Power System Monitoring Recorder TESLA 3000

RT7-48V/6kW Specification

PQ ANALYZER PROCUREMENT SAMPLE SPECIFICATION

PGC 4000v2 POWER GENERATION CONTROLLER

Power Sensing Products

SEL-710 Motor Protection Relay

MI 2792A PowerQ4 Plus

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

General Specifications

Nexus 1250 /1252 High Performance SCADA Monitor

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Transcription:

exus 1500 Transient Recorder and Power Meter With dvanced Power Quality and ommunication ccumeasure utoalibrating Metrology 0.06% Energy ccuracy Perfect hoice for ritical pplications olor Touch Screen Display UltraHigh Performance E61000430 lass www.electroind.com ommunication, I/O and User Interface Standard 10/100aseT Ethernet Port Expandable Serial Ports (Dual RS485 Ports) Modbus SII, Modbus TP, DP 3.0 Level 2 8 Simultaneous onnections via Ethernet Optional Second Ethernet Port Vivid 256 olor Display Optional 100aseT Fiber Optic Port Data Download Speed 20 Times Faster Than Existing Technology ew Generation Transient Recording Power Quality nalysis 10MHz Transient Recorder (over 166,000 Samples per ycle) 8 hannel Waveform Recorder Voltage Surge, Sag and Transient Recording urrent Fault Signatures and nalysis EW Up to 16 Relay Outputs Up to 40 Digital Status Inputs 1 Gigabyte Memory Highly Extensive Recording apability E61000430 lass ertified Electro Industries/GaugeTech The Leader in Power Monitoring and Smart Grid Solutions

utoalibrating Energy Measurement Metrology Introduction From today s utility giants or Fortune 100 companies, to local electrical municipals, an effective energy management and power monitoring program is critical to success. The exus 1500 meter is the most advanced monitoring product on the market today, providing you with the total picture of energy usage and power quality from any metered point in a power distribution network, allowing you to make power related decisions quickly and effectively. Technology specifically designed for Utilities and Industry Real Time power quality monitoring and analysis identifies PQ and reliability events quickly Manage peak demand electrical power usage Report data quickly and reliably using Ethernet or serial communications dvanced transient analysis for critical power systems lso the perfect solution for ircuit reaker or Transformer monitoring The Perfect Monitoring hoice for ritical pplications Utility transmission line substations Power generation Highly critical industrials Hospitals / medical High Performance Revenue Metering Features Extensive Load Profiling: log virtually unlimited historical trending. System Events (nti Tampering): the unit provides extensive usage information for detection of unauthorized access. The unit records: Resets Programming changes Password access changes Time changes Power up/down hange of firmware Transformer Loss and Line Loss ompensation: for both iron and copper and total substation losses. Load ggregation/universal Metering: pulse inputs can be used to aggregate or accumulate different loads; utility products such as gas and water can also be accumulated. Time of Use apability: bidirectional consumption and demand; 20 year calendar. Max/Min Integration and Recording: timestamped max and min values for all measured readings. oincidental Readings: identify number of capacitors needed, peak inefficiencies, etc. Password Protection Prevents Unauthorized Tampering: User programmable passwords. Predicted Demand: The meter uses rate of change to predict the peak demand of the next demand interval. Perfect for proactive load shedding. ccumeasure utoalibrating Measurement Technology EIG s patented ccumeasure utocalibration technology allows a fieldmounted metering device to achieve precision accuracy and maintain the accuracy over temperature and time. This technique is unique to EIG and consists of precise measurement technology and high precision internal reference standards. ccumeasure Technology Features: 8 Independent highspeed 16it /D converters Internal reference for periodic autocalibration Internal temperature sensor to sense deviations in instrument temperature Designed to allow for repeatable and consistent energy measurement results enefits of utoalibrating Technology: Improves accuracy over temperature Improves repeatability, reducing meter settling time Improves longterm stability Relies on precision internal D references to maintain accuracy PRMETER Voltage (L) Voltage (LL) urrent Frequency kw @ Unity PF kw @ 0.5 PF kv kvr (0.50.9 PF) PF Harmonic Magnitudes kwhours kvhours kvrhours 100 msec* 0.03 Hz / / / / VSwitch Technology The exus 1500 meter is equipped with EIG s exclusive VSwitch technology, which enables meter upgrades in the field without removing the meter from service. exus 1500 VSwitch keys include: V1: Standard exus 1500 meter with 128 Megabytes memory + 512 samples per cycle V2: V1 + 1 Gigabyte total memory + 1024 samples per cycle V3: V2 + 10MHz Transient recording 1 SEOD* 0.05% 0.05% 0.025% 0.01 Hz 0.06% 0.2% 0.06% DISPLY RESOLUTIO 3 Digit 3 Digit 16 Digit 16 Digit 16 Digit * ote: Readings are in percent of reading where applicable (more accurate standard), not in percent of full scale (less accurate standard). illing Data and System Reliability Monitoring 2

High Resolution Transient Sensing Power Quality Recorder E61000430 lass Power Quality and Waveform Recording EIG s exus 1500 meter is one of the industry s premier fault and voltage disturbance recorders. This instrument captures a comprehensive picture history of voltage reliability and power quality events within mass memory for detailed and extensive forensic engineering analysis. 16 it Waveform and Fault Recorder: Record up to 1024 samples per cycle consisting of transient captures at over 166,000 samples per cycle Voltage and current recording with pre and postevent analysis Fault recording offers 8 times full scale capture capability 16 bit /D converter provides precise waveform resolution oth hardware and software triggers available HighSpeed Status Input Triggers: Waveforms are recorded at time of status change Input change and waveform recording are time stamped to a 1 msec resolution E61000415 Flicker Meter: Flicker compliant with E61000415 standard Operates on both 220 Volt/50 Hz and 120Volt/60Hz voltages throughout standard test points E61000430 Reporting: Full reporting of power quality conditions using the E61000430 lass methodology E6100047 Harmonics and Interharmonics nalysis: View harmonic magnitudes to 512th order for each voltage and current channel Real time harmonic magnitudes are resolved to the 128th order Percent THD and KFactor onduct power quality analysis at the high end of the harmonic magnitude spectrum Subcycle 10MHz Transient Recorder (V3 Option): Transients often cause intermittent, expensive periods of downtime. The subcycle transient recorder allows you to: Record subcycle transients at 10MHz resolution Monitor switching noise from capacitors, static transfer switches, SRs, and other devices that negatively impact power quality This feature is essential for critical applications such as hospitals, waferfabs plants, data centers and other highly power quality sensitive applications Independent ITI/EM Log Plotting: Quickly view total surges, sags, and average duration in the independent ITI/EM log Phasor nalysis: The monitor reads a phase angle analysis between the voltage and current channels, allowing you to analyze efficiency and system integrity utomatic generation of E50160 reports Multichannel Waveform Recorder Phasor nalysis Subcycle Transients with 10 MHz Pickup Frequency E61000415 Flicker ompliance 3

1 Gigabyte Extensive Onboard Mass Memory Securely Records ll Data Multiple Programmable Memory Logs Virtually Unlimited Historical Trending Logs: The exus 1500 meter includes vast amounts of memory. user partitions this memory for log storage by setting up both the number of logs and the number of parameters per log. 8 independent historical logs with up to 64 parameters per log are available. With such extensive memory, the meter will log for years. Extensive Memory Reads Data Indefinitely Extensive Historical Trending Out Of Limit Log: The unit offers an independent out of limit log. This allows a user to download out of limit information to obtain a sequence of events for any occurrence. Utilizing the 1msec clock resolution, the logs can be combined with different metered points throughout a distribution system to provide an accurate systemwide depiction of a power disturbance. EventTriggered Waveform Recording Log: The exus 1500 meter records waveforms with a resolution of up to 1024 samples per cycle. The amount of waveform recording is based on the amount of memory installed. The unit records the waveform when a value goes out of limit and when the value returns to normal. ll information is timestamped to the nearest 1msec. 8 onboard HighSpeed Inputs can be tied to the waveform recording. ompare relay trip and breaker timing graphically Provides fault and breaker integrity analysis The unit can be programmed to take more than one recording every time an event occurs. Thousands of cycles can be recorded per event. ITI/EM Log: The exus 1500 meter stores a separate EM log that records magnitude and duration of voltage and current surges and sags for every power quality event. This allows the user to conduct real time EM analysis without downloading all stored waveforms. The separate EM log also allows the unit to provide a more comprehensive picture of power quality over time. Out of Limit Log ITI / EM Trending System Events Log: The exus 1500 meter logs extensive usage information for detection of unauthorized access. The unit records: Resets Programming changes Password access changes Time changes Power up / power down hange of firmware Input Status Log: This log allows the user to record when the internal inputs change status. Uploadable Flash Memory: The exus 1500 meter utilizes uploadable flash memory technology on all processors and DSPs located in the unit. This insures that the unit can be upgraded without removing it from service. Set Limit ontrol: The exus 1500 power monitor provides programmable setpoints for user settings. This feature allows a user to configure the meter to be used as a control device for many applications such as: apacitor control Load shedding utomatic transfer schemes Transformer monitoring & control Redundant protection (not designed for primary overcurrent protection) Many other control functions Waveform / Transient Logs: The 1500 can log waveform, utilizing its programmable memory for all surges, sags and transients within the scope of what it sees. Thousands of events can be logged with resolution up to 1024 samples per cycle and transients at 10MHz resolution. ustom llocatable Memory Structure: user can custom define log sizes within the meter. Thus the full memory can be allocated specifically to the desired function. onfigurable Memory llocation Table 4

Superfast Robust Download ommunication Speed 20X and Faster Output Means Features Easier To Use Onoard ommunication for Every pplication Standard ommunications: 10/100aseT Ethernet RJ45 port SI optical port and US 2.0 port 8 uiltin Digital HighSpeed Status Inputs: Inputs automatically sense whether the circuit is externally wetted If externally wetted, input up to 150VD is accepted If internally wetted, the meter supplies the necessary voltage for the control application Sync. heckux. Volt Input Highspeed ux input can be used for: eutral to ground or aux voltage readings Synchronizing schemes Obtain the freq, magnitude, and phase angle on both sides of a switch, or between generator and bus voltage for synch schemes Optional RS485 and Second Ethernet Port: Two identical builtin serial ports up to 115k baud Standard protocols include Modbus RTU/SII and DP 3.0 Level 2 lso available, second Ethernet port, either RJ45 or Fiber Optic Separate M address and configuration for each Ethernet port Industry Leading DP 3.0 Level 2 Plus complies with DP Level 1 and Level 2 certification requirements, plus: Up to 136 measurements (64 inary Inputs, 8 inary ounters, 64 nalog Inputs) can be mapped to DP static points in the customizable DP Point map Up to 16 relays and 8 resets can be controlled though DP Reportbyexception processing (DP Events) deadbands can be set on a perpoint basis 250 available events, of combinations of four events (inary Input hange, Frozen ounter, ounter hange, nalog hange) vailable Freeze commands: Freeze, Freeze/ock, Freeze with Time, Freeze with Time/ock Freeze with Time command enables the meter to have internal time driven Frozen ounter and Frozen ounter event data Programmable secondary scale allows users to maximize 16 bit analog input resolution precisely around the desired parameters providing enhanced resolution to SD EW Rapid Response Ethernet Download data over 20 times faster than existing exus technology: Rapid Response 10/100aseT Ethernet allows for 8 simultaneous connections of Ethernet Modbus TP protocol. Two sockets for DP 3.0 protocol are also available. Rapid Response technology insures that the exus meter is optimized to download data as quickly as possible. Utilizing a novel Modbus TP approach, the meter will download up to 20 times faster than existing exus 125X Series meters. o long wait time to retrieve data. 8 HighSpeed Status Inputs 2 RS485 Ports (Optional) SI Optical Port IRIG Input 2nd Ethernet Port (Optional) Onboard Ethernet TP/ IP onnection Internal I/O Relay Outputs: 6RO1: 6 Relay Outputs ard 5 mps/250 V 30 VD rated Form (Latching) Pulse Outputs: 485P: Dual RS485/Pulse Output ard 4 KYZ pulses Pulse width: 5 msec Relay type: Solid State Dual RS485 ports Digital Input Status: 16DI1: 16 Status Inputs ard Used for alarm detect or pulse accumulation Up 150 Volts D wetted or nonwetted (24 Volt D nominal provided) ote: The exus 1500 meter provides one I/O slot for the 485P (Slot 1), and two I/O slots for the 6RO1 and 16DI1 (Slots 3 and 4). External I/O nalog Outputs: 1mO4/1mO8: 4 or 8 nalog Outputs, 01m, selfpowered, scalable, bidirectional 20mO4/20mO8: 4 or 8 nalog Outputs, 420m, selfpowered, scalable Wiring: ommon Mode ccuracy: of Full Scale alibration: Selfcalibrating Scaling: Programmable Ordering: Up to 4 nalog Output modules for each exus 1500 meter Digital Dry ontact Relay Outputs: 4RO1: 4 Relay Outputs, 5 mps, 125 /D, Form Latching Relays Ordering: 1 module in addition to internal modules Digital Solid State Pulse Outputs: 4PO1: 4 Solid State Pulse Outputs, Form or KYZ pulses Maximum Pulse Speed: 20 pulses per second Ordering: Up to 4 modules per meter olor LD Revenue Lock 4 Voltage Inputs 4 urrent Inputs Output Module ccessories (Required): PSIO: Required for using an Output module and must be ordered with the module. The exus 1500 does not have internal power for Output modules. High Speed US Port 2 LED ccuracy Test Pulses MIO: Mounting bracket for Output modules. Must be ordered with Output module. 5

Dimensional Drawings 10.74 /27.28cm 6.86 /17.42cm 7.49 /19.02cm 1.76 /4.47cm 5.10 /12.95cm 4.44 /11.28cm 5.94 /15.09cm 6.74 /117.12cm Wiring Diagrams Ts ux /U ux /U PTs 4Wire Wye, 2.5 Element, 3 Ts and 2 PTs 3Wire, 2 Element Delta Direct with 2 Ts Ts ux /U Ts ux /U PTs 4Wire Wye, 3 Element with 4 Ts and 3 PTs 4Wire Wye, 3 Element with 4 Ts and no PTs 6

Vibrant olor LD Touch Screen Display right and Easy To Read The exus 1500 meter features an LD color display with touch screen capability. The display uses bright TFT glass with a high temperature and long life LED backlight. LED is superior to FL solutions due to better temperature and halflife specifications. Screen displays include: Realtime viewing (voltage, current, power, demand) ccumulated energy and time of use readings Flicker readings larms Phasor analysis Harmonic spectrum analysis and waveforms Real time trending Vivid olor Display Log status onfiguration settings Specifications Input Voltage Range: (5347)V, Line to eutral (10600)V, Line to Line Voltage Input Withstand apability: Voltage Inputs isolated to 2500V Meets SI 37.90.1 (Surge Withstand apability) Input urrent Range: 5 mp Inputs 4x continuous programmable to any T range Fault current recording to 80 mps peak secondary based on 5 mp full scale urrent Input Withstand apability (at 23 ): 100 mps for 10 seconds 300 mps for 3 seconds 500 mps for 1 second urden: Voltage Inputs: 0.072W/Phase Max at 600 Volts, 0.003W/phase max at 120 Volts urrent Inputs: 0.008V per phase max at 20 mps Isolation: ll inputs to outputs are isolated to 2500 V. Temperature Rating: Operating temperature: (20 to +70) Humidity: Up to 95% RH noncondensing Storage temperature: (30 to +80) Sensing Method: Up to 1024 samples per cycle (programmable) Voltage Transient: 10MHz ±1.8kV ±10% 16 it /D resolution multiple converters Utilizes patented ccumeasure technology True RMS ccuracy Rating: This unit complies with and exceeds SI 12.20 and IE6205322 accuracy requirements Update Time: 1 Second Revenue accurate readings 100 msec High speed readings ontrol Power Requirements: (Suffix D2): (90 265)V, (100370)VD urden: 25V Max Frequency Range: 45Hz 69.9Hz ommunication Format: Programmable parity and stop bits ommunication protocols: Modbus TP/IP, SII/RTU, DP 3.0 SI optical port US 1.1/2.0 Virtual OM port RJ45 Ethernet port 10/100aseT 2 RS485 ports (optional) Shipping: Total shipping weight: approx. 5 lbs (2.3 kgs) Shipping container dimensions: 16" x 13" x 11" (40.64cm x 33.02cm x 27.94cm) ompliance: SI 12.20 lass 0.2 and IE 6205322 (ccuracy) SI 62.41 (urst) SI/IEEE 37.90.1 Surge Withstand IE 6100042 ESD IE 6100043 Radiated Immunity IE 6100044 Fast Transient IE 6100045 Surge Immunity IE 61000415 Flicker Meter IE 6100047 Harmonics IE 61000430 lass E Marked UL and cul Listed External Output Modules 1mO4: 1mO8: 20mO4: 20mO8: 4RO1: 4PO1: PSIO: MIO: 4 nalog Outputs, 0 1m 8 nalog Outputs, 0 1m 4 nalog Outputs, 4 20m 8 nalog Outputs, 4 20m 4 Relay Outputs 4 Solid State Pulse Outputs Power Supply for additional Output modules (must be ordered with external module) Output mounting bracket (must be ordered with external module) 7

Ordering Information To order a exus 1500 meter: 1. Fill out the options you want in the order chart shown below. List accessories separately. 2. Specify ommunicator EXT 3.0. 3. EIG can also provide current and potential transformers. 4. Email or fax order information and quantity to the fax number or email listed at the bott om of this page. Ordering Specifications exus ase Meter ontrol Power Frequency Range urrent lass Virtual Switch ommunication Expansion / Slot 1 I / O Slot 2 I / O Slot 3 I / O Slot 4 Option umbers: Example: exus 1500 D2 60 Hz 20 V2 485P TRJ 6RO1 6RO1 exus 1500 Meter 115 (100240)V 60 Hz 20 20 mp V1 Standard exus 1500 meter 128 M memory / 512 s/c X o Option X o Option X o Option X o Option D2 50 Hz Universal (90265)V @50/60Hz or (100370)VD 2 2 mp V2 V1 + 1 G memory / 1024 s/c 485P 2 RS485 and 4 Pulse Outputs TRJ Second RJ45 etwork ard 6RO1 6 Relay Outputs 6RO1 6 Relay Outputs V3 V2 + 10 MHz Transient Recording TFO Second Fiber etwork ard (ST Terminated) 16DI1 16 Status Inputs 16DI1 16 Status Inputs ccessory Options SOFTWRE OMEXT3.1 ommunicator EXT 3.0 for Windows Singleomputer License (One Site) OMEXT3.M ommunicator EXT 3.0 for Windows Multipleomputer License (One Site) OUTPUT MODULES 1mO4 4 nalog Outputs, 0 1m 1mO8 8 nalog Outputs, 0 1m 20mO4 4 nalog Outputs, 4 20m 20mO8 4RO1 4PO1 PSIO MIO 8 nalog Outputs, 4 20m 4 Relay Outputs 4 Solid State Pulse Outputs Power Supply for External Output modules (must be ordered with an external module) Output Mounting racket (must be ordered with an external module) bout Electro Industries: Electro Industries/GaugeTech is one of the oldest and largest manufacturers of microprocessorbased digital power meters in the United States. EIG's success is attributable to our willingness to support our users with onstaff technical expertise. ontact us and we will assist you in solving your complex metering applications. Electro Industries/GaugeTech The Leader in Power Monitoring and Smart Grid Solutions 1800 Shames Drive, Westbury, Y 11590 1 877 EIMETER (1 877 346 3837) Tel: 516334 0870 Fax: 5163384741 Email: sales@electroind.com www.electroind.com E154705 062112 G